ML20125B959

From kanterella
Jump to navigation Jump to search
Notification of 780314 Meeting W/Util & GE in Bethesda,Md to Resolve Structural Issues Re Review of GE High Density Fuel Storage Sys at Plant
ML20125B959
Person / Time
Site: Monticello 
Issue date: 03/09/1978
From: Bevan R
Office of Nuclear Reactor Regulation
To: Lear G
Office of Nuclear Reactor Regulation
References
NUDOCS 9212100229
Download: ML20125B959 (3)


Text

.3, Uoc.ffc3

l P M.3

.x.

[

. + ^

I Harch 9, 1978

%i e

t-EMDRANDLM FOR: George Lear, Chief, Opprating Reacten_ Branch #3, DDR '

FR(M:

Roby Bevan, Project Manager, Operettag Reactors Branch #3, D0R

SUBJECT:

FORTHCOMING MEETING TO DISCUSS STRUCTURAL ASPECTS OF MONTICELLO SPENT FUEL POOL MODIFICATION-Date & Time:

Tuesday, March 14, 1978 8:30 A.M. - 12:00 Noon Location:

Roorn P-501, Phillips Building Bethesda, Maryland-

Purpose:

To resolve structural issues related to

' the review of the General Electric High-Density Fuel Storage System at the Monticello Nuclear Generating Plant

Participants:

NRC G. Johnson, G. Bagchi.- A.. Gluckraan, R. Snaider, R. Bevan, R. Clark NORTHERN STATES POWER COMPANY M. Voth GENEPAL ELECTRIC COMPANY C. Herringtone W. Weiden, E. Grise, P. Sun, J. Reed Original timd bV Roby Bevan, Project Manager Operating Reactors Branch 13 Division of Operating Reactors I

.)

... 0 b

..'M**

. ~ ~

+~.

O RB avan:rnjf 3/j/78

.g NRC FORM 318 (9 76) NRCM 0240 1'r us s. movannu ent enmvene orrica novo - ese-es4 9212100229 780309:

PDR ADOCK 05000263 P

PDR

.. ~. -

N'

~

N As aar

'o UNITED STATES NUCLEAR REGULATORY COMMIS$10N t

'i wAssincTow, o. c. rosos

/

March 9, 1978-i MEMORANDUM FOR:

George Lear, Chief, Operating Reactors Branch 13 DDR-FROM:

Roby Bevan, Project' Manager, Operating Reactors Branch #3, D0R

SUBJECT:

FORTHCOMING MEETING TO DISCUSS STRUCTURAL ASPECTS OF-

.MONTICELLO SPENT FUEL POOL MODIFICATION Date '& Time:

Tuesday, March 14. 1978 8:30 A.M. - 12:00 Noon Location:

Room P-S01', Phillips Building Bethesda,. Maryland

Purpose:

To resolve structural issues related to-the review of the General Electric High Density Fuel -Storage System at the Monticello Nuclear Generating-Plant -

Participants:

NRC G. Johnson, G. Bagchi, A. Gluckman, R. Snaider, R. Bevan, R. Clark NORTHERN STATES POWER COMPANY M. Voth.

GENERAL ELECTRIC' COMPANY C. Herrington, W.-Weiden, E. Grimm, P. Sun, J. Reed.

.Roby evan Project Manager Operating Reactors Branch #3-

. Division of: Operating Reactors

,_- e-9.

C

~

i MEETING NOTICE DISTRIEUTION HRC PDR I

I4 cal PDR Docket Files ORBf3 Rdg BCRusche I'CCase VStello KRGoller TJCarter GLear Project Manager CParrish OELD OI6E (3)

ACRS (16)

NRC Participants OSD (3)

Receptionist EFaulkenberry DEisenhut LShao Ecrimes RBaer ASchwencer DZicnann RReid W. Mcdonald D. Thoepson J. Reece W. Butler

.p a

s' e

1

't N

O