ML20125B069

From kanterella
Jump to navigation Jump to search
Notice of Violation from Insp on 751110-19
ML20125B069
Person / Time
Site: Crane 
Issue date: 12/18/1975
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To:
Shared Package
ML20125B061 List:
References
50-289-75-25, NUDOCS 7910190524
Download: ML20125B069 (1)


Text

l m

H

^"

License No. DPR-50 APPENDIX A

_ ().

NOTICE OF VIOLATION Based on the results of the NRC inspection conducted on November 10-19, 1975, it appears that one of your activities was not conducted in full gompliance with conditions of your license as indicated below:

7

q A.

Contrary to Technical Specification 6.2.3 requirements for adherence

..O to procedures, the following examples of nonconpliance with procedures were identified.

l'.

Data recording requirebents of SP1303-4.1 were not met for tests performed on July 22, 1975 and September 24, 1975; in that High Flux bistable input voltage at the trip point was not recorded j

quired by the procedure. Actual system settings did not J

ed, Limiting Sa_ety System Settings in this case.

2.

The power, range amplifier resetting administrative 1y required by SP1302-1.1 to assure setpoint maintenance within the appro-priate range was not accomplished on August 7, 1975.

Actual system settings did not exceed Limiting Safety. System Settings in this case.

"m

(

')

This item is a Deficiency.

l

()- /

r i"

90012521 l

{

l I.

)

7910190 1

w

,