._ __ _

i l

i August 30, 1979 l

Docket No. 50-320 i

Mr. John C. Herbein, Vice President Nuclear Operation Metropolitan-Edison Company Trailar Number 120 Middletown, Pennsylvania 17057 Daar Mr. Herbein; i

In reviewing your responses to our questions regarding the loss of continuous natural circulatica and its effect on plant safety contained in your letter j

dated August 17, 1979, CQL 1074, we find that additional information is s

required. This additional information consists of the SW conservativa

)

analysis of thermal cycling of the OTSC which abows that it can withstand at least 10' cycles.

Couplation of our review is awaiting this information. Your prompt submittal will be appreciated.

Sincerely, 4

l John T. Collins, Deputy Director TMI-2 Support cc:

R. Vollmar M. Greenberg S. Newberry i

J. Verr.iel A.,Ignatonis l

S. Maingi B6W i

i TMI-2 TMI-2 AIgnatonis:si JCollins 8/ /79 8/ /79 7910190 C)h

-