3/d i

THE CLEVELAND ELECTRIC ILLUMIN ATlHG COMPANY l

P.O.

BOX 97 m PERRY. OHIO 44081 e

TELEPHONE (216) 259-3737 m

ADDRESS-10 CENTER ROAD Serving The Best Location in the Nation PERRY NUCLEAR POWER PLANT May 7, 1985 PY-CEI/OIE-00042LQ Mr. James G. Keppler Regional Administrator, Region III Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, Illinois 60137 RE:

Perry Nuclear Power Plant Docket Nos.

50-440; 50-441 Potential Leakage Path in Electronics Housing Threads of Transmitters Supplied by Rosemount [ RDC 115(84) ]

Dear Mr. Keppler:

This letter serves to update the status of our corrective actions associated with Rosemount Model 1153 Series B Pressure Transmitters as discussed in our Final Report dated January 24, 1985.

These transmitters had potential for a leakage path in the seal of the threads between the sensor module and the n.lectronics housing.

All subject Rosemount transmitters have been repaired by the ven-dor and returned to the site.

The corrective actions necessary for resolution of the reported deficiency have now been completed.

The reinstallation of Unit 1 transmitters will be completed consistent with the Preoperational Test schedule.

qincerely,

/hwt

[

5' %

Murray R.

Edelman Vice President Nuclear Group MRE:sab cc:

Mr. J. A. Grobe Records Center, SEE-IN USNRC Site Office (SBB50)

Institute of Nuclear Power Operations Mr. D. E. Keating 1100 Circle 75 Parkway, Suite 1500 USNRC Site Office (SBB50)

Atlanta, Georgia 30339 Director Office of Inspection and Enforcement 8505170512 850507 U.S. Nuclear Regulatory Commission PDR ADOCK 05000440 Washington, D.C.

20555 S

PDR U.S. Nuclear Regulatory Commission

[hgr Document Control Desk Washington, D.C.

20555 O

MAY 9 1985

  1. j