Transmits Sample Plan for Snubber Functional Testing During Quad Cities Station (Qcs) Unit 2 Refuel Outage Q2R14 & Qcs Unit 1 Refuel Outage Q1R15,respectively
ML20117H509
Person / Time
Site: Quad Cities  
Issue date: 05/20/1996
From: Kraft E
COMMONWEALTH EDISON CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
ESK-96-077, ESK-96-77, NUDOCS 9605280234
Download: ML20117H509 (4)


Text

1 Commonwealth bitwn Compan, o

Quad Citics Generating Station

, 22710 2WHh Asenue North Cordova. !!. o1212 9' 10 Tel.W H M 2241 ESK-96-077 I

May 2J,1996 U. S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, DC 20555

Subject:

Quad Cities Station Unit I and Unit 2 i

Snubber Functional Test Sample Plans - Q1RIS & Q2R14 1

NRC Docket No. 50-254 and 50-265

Reference:

J. L. Schrage to J. B. Martin, letter dated April 12,1994.

In the referenced letter, in accordance with Technical Specification 4.1.5, Commomvealth Edison (Comed) submitted the snubber testing sample plan for 18-month Snubber Functional Tests for Quad Cities Unit 1, i

Refuel Outage 13 (QlR13) and Quad Cities Unit 2, Refuel Outage 13 (Q2R13). This letter transmits the sample plan for snubber Functional Testing during Q2R14 and QlRIS (Attachments 1 & 2 respectively).

l If there are any further questions regarding this issue, please contact Nicholas Chrissotir.ios, Quad Cities Regulatory Assurance Supervisor, at (309) 654-2241, extension 3100.

Sincerely,

.p E. S. Kraft, Site Vice President Quad Cities Station Attachments:

(1) Q2R14 Snubber Plan (2) QlRIS Snubber Plan cc:

H. J. Miller, Regional Administrator, Region 111 C. G. Miller, Senior Resident inspector - Quad Cities Station R. M. Pulsifer, Project Manager - NRR Office of Nuclear Facility Safety - IDNS D. B. Tubbs, MidAmerican Energy Company R. J. Singer, MidAmerican Energy Company p9

,I U

i 9605280234 960520 I

PDR ADOCK 05000254 P

PDR A iinicom Company

O'2R14 SNUBBER TENING SCOPE April 26,1996 ATTACHMENT 1 l

QUAD CITIES STATION UNIT - 2 REFUEL OUTAGE Q2R14 TECHNICAL SPECIFICATION SNUBBER FUNCTIONAL TESTING SCOPE l

QUAD CITIES UNIT 2 TECH SPEC (SAFETY RELATED) SNUBBER POPULATION IS 129 SNUBBERS A. FUNCTIONAL TESTING SCOPE 1.

TECH SPEC 10% SAMPLE:

a.

Testing Wil be performed with the following Station procedures:

QCAP 0410-05

. OCTS 0750-05 b.

Total of 13 Snubbers will be tested during the outage.

Breakdown of the Sample IS:

5 Snubbers in the Drywell 4 Snubbers in the Reactor Building 1 Snubberin the MSIV Room 3 Snubbers in the Turbine Building c.

System breakdown of the 10% Sample:

Tech Spec Snubbers:

TECH SYSTEM WORK SERIAL SNUBBER ISI NUMBER LOCATION DRAWING SPEC #'

REQUEST #

TYPE AND NUMBER Sr2E 2-1

  • 1400 960018010-01 6768 PSA-10 1403-W-103 A&B ORYWELL 3RD LEVEL M-1016D-251 2-23
  • 0202 96001800H1 1065 PSA-35 0200-M-112 DRYWELL 1ST LEVEL M-1022D-277 2-41 3000 960018015-01 16158 PSA-3 Non-Code MSIV ROOM M-1020D-503 2-43 3000 960018012-01 7900 PSA-35 Non-Code STEAM TUNNEL M-1020D-03 2-45 3000 960018100-01 7934 PSA-35 Non-Code STEAM TUNNEL M-1020D-04 2-47 3000 960018171-01 7930 PSA-35 Non-Code STEAM TUNNEL M-10200-02 2-54
  • 3000 960018175-01 61300/61 LISEGA-5 3001 A-M-101.1 DRYWELL 2ND LEVEL M-328E SHT.1 2-62
  • 3000 960018179-01 61300/66 LISEGA-5 30018-M-103.1 DRYWELL iST LEVEL M-328F SHT. 4 1

2-89

  • 3000 960018193-01 61310/33 LISEGA-6 30018-M-101.2 DRYWELL 2ND LEVEL M-328F SHT. '

2-96 1000 960018195-01 1720 F SA-100 Non-Code REACTOR BLDG M-1802-23 BASEMENT 2 115*

2300 960018200-01 12729 PSA-10 2306-M-205 2 2"B" CORE SPRAY ROOM M-1813-05 2-134 1300 960018202-01 12697 PSA-10 Non-Code 2"B" CORE SPRAY ROOM M-1814-08 2-138

  • 1000 960018206-01 15161 PSA-1 10438-M-301.1 2"B" RHR ROOM M-1026D-126
  • ASME Code (Section XI) Snubbers Michael A. Pompeo Snubber Coordinator Station Support Engineering Group x2165 Pager# 354 PAGE 1 OF 1 t

dlR15 SNUBBER TESTING SCOPE May 7,1996 ATTACHMENT 2 QUAD CITIES STATION UNIT 1 REFUEL OUTAGE Q1R15 TECHNICAL SPECIFICATION SNUBBER FUNCTICNAL TESTING SCOPE QUAD CITIES UNIT 1 TECH SPEC (SAFETY RELATED) SNUBBER POPULATION IS 118 SNUBBERS A. FUNCTIONAL TESTING SCOPE 1.

TECH SPEC 10% SAMPLE i

i a.

Testing will be performed with the following procedures:

QCAP 0410-05 QCTS 0750-05 b.

Breakdown of the Sample is:

6 Snubbers in the Drywell 4 snubbers in the Reactor Building 2 snubbers in the MSIV ROOM C.

System breakdown of the 10% Sample:

Tech Spec Snubbers:

TECH SYSTEM NWR#-

StERIAL SNUBBER ISI NUMBER LOCATION -

DRAWING -

SPEC TYPE AND NUMBER-SIZE 11*

1400 960046385-01 3205 PSA-10 1403-W-103 A&B DRYWELL 3RD LEVEL M-983D-254 1-18' 0202 960042915 01 1066 PSA-35 0200-M-110 DRYWELL iST LEVEL M-990D-273 1 33 0300 960042911-01 2678 PSA 1 NON-CODE DRYWELL 1ST LEVEL M-1053-EM-SHT.1,2,3 1-39 1600 960042909-01 8713 PSA-1/2 NON-CODE REACTOR BLDG BASEMENT M-833-SHT. 35 1-46*

0202 960042793-01 25170 PSA-3 0200-M-174 DRYWELL 1ST LEVEL M-990D-4 1-55 3000 960042908-01 6858 PSA-35 NON-CODE MSIV ROOM M-9880-7 1-56 3000 960042841-01 6865 PSA-35 NON-CODE MSIV ROOM M-988D-6 1-59 3000 960042840-01 61293/99 LISEGA-4 NON-CODE DRYWELL 1ST LEVEL M-328A SHT.10 1-64*

3000 960042837-01 61278/94 LISEGA-5 3001 B-M-101.2 DRYWELL 2ND LEVEL M-3288 SHT. 7 1-81 1000 960042835-01 778 PSA-100 NON-CODE REACTOR BLDG BASEMENT M-1602-03 1-110*

1000 960042807-01 12726 PSA-10 10128-M-203.1 REACTOR BLDG TOP OF M-1611-15 TORUS 1-128' 0300 960042790-01 24663 PSA-3 0328-M-201 REACTOR BLOG 1ST FLOOR M-985D-1022 2.

SERVICE LIFE MONITORING AND FAILURE TRENDING SAMPLE:

a.

Breakdown of the sample is:

2 snubbers in the Drywell c.

System breakdown:

PAGE 1 OF 2

GIRI5 SNUBBER TESTING SCOPE TECH SYSTEM NWR#

SERIAL SNUBBER ISI NUMBER LOCATION DRAWING SPEC TYPE AND NUMBER SIZE 1

1-61 3000 960046387-01 61293/98 LISEGA-4 NON-CODE DRYWELL 1ST LEVEL M-328A SHT.13 1-124*

1000 960042789-01 30695 PSA-3 1025-M-102 A&B DRYWELL iST LEVEL M-9940-23 I

  • ASME CODE SECTION XI SNUBBERS Michael A. Pompeo Snubber Coordinator Station Support Engineering Group x2165 Pager# 354 PAGE 2 OF 2