_ _ _ _ _ _ - _ _ _ _ _ _ _ _ _ - _ _ _ _ _ _ _ _ _ - _ _ _ _ _ _ _ _ _.

VINGINIA ELucTnIc Axn POWER COMPANY RIci!xoNu,VINGINIA 20261 May 16, 1996 United States Nuclear Regulatory Commission Serial No.96-154 Attention: Document Control Desk NURPC Washington, D.C. 20555 Docket No. 50-338 License No. NPF-4 Gentlemen:

VIRGINIA ELECTRIC AND POWER COMPANY NORTH ANNA POWER STATION UNIT 1 INSERVICE INSPECTION

SUMMARY

REPORT FOR THE 1996 REFUELING OUTAGE As set forth in the provisions of ASME Section XI, paragraph IWA-6230, enclosed is the Inservice Inspection Report for North Anna Power Station Unit 1 for the 1996 refueling outage. This report is a summary of examinations performed during the outage to satisfy requirements for the third period of the second ten-year inservice inspection intental.

In accordance with IWA-6220 of ASME Section XI, a Form NIS-1 Owner's Report for Inservice inspections, an examination summary, and abstracts of examinations performed are provided with this report in Attachment 1. The NIS-2 Forms, Owner's Reports for Repairs or Replacements, are provided in Attachment 2. Attachment 3 provides the Owner's Report of Evaluation Analyses.

Should you require more detailed information, the entire report will be maintained on file at the station and at the corporate office.

Very truly yours, M. L. Bowling, Manager Nuclear Licensing and Operations Support

~ '-

Attachments g 52$00 h 050bo338 O

PDR cc:

U. S. Nuclear Regulatory Commission Region 11 101 Marietta Street, N. W.

Suite 2900 Atlanta, Georgia 30323 220012 Mr. R. D. McWhorter NRC Senior Resident inspector Og North Anna Power Station l {

t