Maximum Doses Resulting from Aquatic Effluents Period of Release 940101-941231 Calculated 960819 Adult Receptor
ML20117C660
Person / Time
Site: Braidwood  
Issue date: 08/19/1996
From:
COMMONWEALTH EDISON CO.
To:
Shared Package
ML20117C657 List:
References
NUDOCS 9608270467
Download: ML20117C660 (4)


Text

'

l REVISED TABLE 3.2 1 BRAIDWOOD STATION UNIT ONE I

r ACTUAL 1994 MAXIMUM DOSES (MREM) RESULTING FROM AQUATIC EFFLUENTS PERIOD OF RELEASE - 01/01/94 TO 12/31/94 CALCULATED 08/19/96 ADULT RECEPTOR i

IST 2ND 3RD 4TH DOSE TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL i

JAN-MAR APR-JUN JUL-SEP OCT-DEC i

t L

TOTAL 1.64E-02 6.32E-03 1.37E-02 5.11E-03 4.16E-02

' BODY -

l INTERNAL-1.95E-02 1.20E-02 1.52E-02 1.31E-02 5.02E-02

. ORGAN j

LIVER-GI_LLI LIVER GI_LLI GI_LLI i

THIS IS A REPORT FOR THE CALENDAR YEAR.1994 i

COMPLIANCE STATUS - 10 CFR 50 APP. I j

...........- % OF APP I. ------------

]

QTRLY 1ST OTR 2ND OTR 3RD QTR 4TH QTR YRLY

% OF OBJ JAN-MAR APR-JUN JUL-SEP OCT-DEC OBJ APP. I JTOTAL BODY (MREM) 1.5 1.10 0.42 0.91 0.34 3.0 1.39

)

CRIT. ORGAN (MREM) 5.0 0.39 0.24 0.30 0.26 10.0 0.50 LIVER GI_LLI LIVER GI_LLI GI_LLI RESULTS BASED UPON:

ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995 I

j i

i l

9608270467 960820 PDR ADOCK 05000456 R

PDR

REVISED TABLE 3.2-1 (Continued)

BRAIDWOOD STATION UNIT TWO ACTUAL 1994 MAXIMUM DOSES (MREM) RESULTING FROM AQUATIC EFFLUENTS PERIOD OF RELEASE - 01/01/94 TO 12/31/94 CALCULATED 08/19/96 ADULT RECEPTOR l

1ST 2ND 3RD 4TH DOSE TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC TOTAL 1.64E-02 6.32E-03 1.37E-02 5.11E-03 4.16E-02 BODY INTERNAL 1.95E-02 1.20E-02 1.52E-02 1.31E-02 5.02E-02 ORGAN LIVER GI_LLI LIVER GI_LLI GI_LLI THIS IS A REPORT FOR THE CALENDAR YEAR 1994 COMPLIANCE STATUS - 10 CFR 50 APP. I

____ ------- % OF APP I. ------------

QTRLY 1ST OTR 2ND OTR 3RD OTR 4TH OTR YRLY

% OF OBJ JAN-MAR APR-JUN JUL-SEP OCT-DEC OBJ APP. I TOTAL BODY (MREM) 1.5 1.10 0.42 0.91 0.34 3.0 1.39 CRIT. ORGAN (MREM) 5.0 0.39 0.24 0.30 0.26 10.0 0.50 LIVER GI_LLI LIVER GI_LLI GI_LLI RESULTS BASED UPON:

ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995 l

REVISED TABLE 3.3 1 BRAIDWOOD STATION UNIT ONE

~

l 10 CFR 20 COMPLIANCE ASSESSMENT 1

PERIOD OF ASSESSMENT 01/01/94 TO 12/31/94 CALCULATED 08/19/96 1.

10 CFR 20.1301 (a)(1) Compliance Total Effective Dose Eqivalent, mrem /yr 3.61E-02 10 CFR 20.1301 (a)(1) limit mrem /yr 100.0

% of limit 0.04 Compliance Summary - 10CFR20 1st 2nd 3rd 4th

% of Otr Otr Qtr Otr Limit TEDE 1.28E-02 6.97E-03 1.10E-02 5.34E-03 0.04 RESULTS BASED UPON:

ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995 1

i l

l'.

REVISED TABLE 3.3-1(Continued)

BRAIDWOOD STATION UNIT TWO l

10 CFR 20 COMPLIANCE ASSESSMENT PERIOD OF ASSESSMENT 01/01/94 TO 12/31/94 CALCULATED 08/19/96 1.

10 CFR 20.1301 (a)(1) Compliance Total Effective Dose Eqivalent, mrem /yr 6.32E-02 10 CFR 20.1301 (a)(1) limit mrem /yr 100.0

% of limit 0.06 Compliance Summary - 10CFR20 1st 2nd 3rd 4th

% of Otr Otr Otr Otr Limit TEDE 1.74E-02 1.27E-02 2.67E-02 6.39E-03 0.06 RESULTS BASED UPON:

ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995 i

l