ML20117A768

From kanterella
Jump to navigation Jump to search
Requests Approval to Proceed W/Certain Maint Tasks Prior to Approval of Decommissioning Plan & Dismantling of Reactor Facility.Tasks Include:Removing Control Rod & Drive mechanism,in-core Instrumentation & Vacuum Sys
ML20117A768
Person / Time
Site: 05000187
Issue date: 04/29/1985
From: Benveniste J
NORTHROP CORP.
To: Bernard H
NRC
References
301-85-JB-062, 301-85-JB-62, NUDOCS 8505080329
Download: ML20117A768 (1)


Text

50- /97 301-85-JB-062 NORTHROP 29 April 1985 Nuclear Regulatory Commission Mr. Hal Bernard 7920 Norfolk Avenue Bethesda, MD 20814

Dear Mr. Bernard:

We have safely completed the transfer of three shipments of fuel to the Universities and now we have only to receive approval of our decommissioning plan to proceed with the dismantling of our reactor facility.

In the'meantime, in order to avoid incurring unnecessary costs associated with the inactivity of our contractor, we would like to proceed with certain tasks which formerly fell under the rubric of maintenance. Our understanding of the work which might be permitted under 10 CFR 50.59 includes:

1.

Remove:

Control rod and drive mechanism In-core instrumentation Vacuum system Support structures Bridge Rails Survey:

All items Store for donation to educational institutions Package as rad waste or release for salvage 2.

Remove and survey all sacrificial wood lining in exposure room.

Take sample of wood, package activated / contaminated wood as rad waste.

Balance will be released.

3.

Take samples of pool water for isotopic analysis.

Submit results to Los Angeles County Sanitation District for approval.

Discharge into sanitary sewer upon approval.

4.

Remove, survey, and decontaminate as needed, demineralizer tanks, filter, cylinders, and heat exchanger.

5.

Cut one-quarter inch thick aluminum window for isotopic analysis.

Upon receipt of analysis, window will be cut. Window will be packaged as rad waste or released as salvage.

We respectfully request your earliest permission to proceed with the above list of tasks.

Ver truly yours,-

h ADOC f

b

. Benveniste, P

j NRTC Chief Scientist

)p Narthrop Curporation. Northrop Research anel Technow;y Centar

{

One Hma ch Park. Patos Veufes Penmsuta, California 90274

  • Tekphone (213) 377-4311