g.

l11 1

l>ubt her Company

7 C hl. wists AlcCaire Nuctror Generation ikpartment '

bice 1*residera Ilfort Ikpers ferry RuaJ (m'GutAI (70HRT5 4WA1 llurumto(k. NClM154%5 (7099754%9 ht l

Y OllKCPOWER

. Xvgl I

November 16,1992 U. S. Nuclear Ro0ulatory Commission Document Contrcl Desk Washington, D. C. 20555

Subject:

McGuiro Nuclear Station, Unit 1 Docket No, 50-309

' Steam Generator inspection Report Pursuant to McGuire Technical Specification 4.4.5.Sa and 4.4 5.5c, this report is submitted for McGuiro.

Unit 1, EOC-7 Refuehng Outage. The following quantity of tubes were inspectoend plugged or repired from either side of the generator; IUhes.LospwtAt NualkefJpJ.Jubor!

.S10il!ILGQf109tM Baillongth ElgagWatflesi.W f

A 4472 172 B

4398 118 0

4393 108

~D 4399

'41 Inforfwation concerning tubo indications of imperfections, locations, and size are provided as attachments 1, 2, 3 anti 4.

Tubes removed from rervice by plugging and repaired by sleeving are identified in attachments 5,6,7 and 8.

-- Questions or problems should be directed to Kay Crane, Regulatory Complianco at (704) 875-4306, Very truly yours, WMA4 T. C. McMeekin, Vice President McGuiro Nuclear Station Attachments b u, f Q,,

9211300222 921116 k

PDR. ADOCK 05000369 i

G PDR n.n,,m m

.A.

_.m t

cc:

T. A. Reed,' Project Manager -

Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Washington, D. C. 20555 -

Mr. S. D. Ebneter, Regional Administrator U. S. Nuclear Regulatory Commission Region 11 101 Marietta Street, NW - Suite 2900 -

Atlanta, Georgia 30323 Mr. P. K. VanDoorn Senior Resident inspector McGuire Nucled. Site R. O. Sharpe l

.j j

l i

5

+..

.r

            • DULE-TUBAN(IM) (VER. 3.0)******

Monday. November 9, IV92 08:44 AM ****** BABCOCK L WILCox CO.~****** Page j]-

t 2

Plantt McGulRE UNil 1'

. Steam Generator A Dutages:

09/91 RF0 09/91 Stv. 09/91 TS 09/91 51

- QUt R Y ; AllACHMCNI 1 INDICATIONS OF IMPCRFECTIONS

-4..,

4..............

kOW COL OUTACC INDICAllDN VALUE VOL15 LOCA110N INCHES 2_

1 09/91 RIO ID (general)

$/N 5,46 His-P

+ 5.66 2 _35 09/91 is 10 (genetal)

S/N 0.20 MTS-S

+ 0.04

'2.54 09/91 ar1 00 (general) 10 % IW 0.81 7

+'0.20 09/91 51 00 (general)

S/N 1.80 8

+ 5.96 2 -51 09/91 IS 10 (generel)-

S/N 0.12 HTS S

  • 0.08 2 71 09/91 RF0 ID (general) 40 % tw 3.36 HTS S i

09/91 1S 10 (general)

S/N 0.20 HIS-S

- 0.04 09/91 TS 10 (general)

S/N 0.24 HIS*S

- 0.04 4

2 75 09/91 iS 10 (generat)

S/N 0.12 HIS-S

- 0.08 2 80 09/01 15 10 (general)

S/N 0,12 HIS+$

0.12 2 87 09/91 15 10 (general)

S/N 0.20 HTS S 0.08 09/91 15 10 (general)

S/N 0.16 HIS-S

- 0.08 2 08 09/91 15 lD (general)

S/N 0.16 HIS*S

+ 0.04 2 104 09/V1 IS ID (general)

S/N 0.16 HIS-S

+ 0.08 3 33 09/91 15 10 (general)

S/N 0.16 HIS S 0.55 3 50 09/91 TS 10 (General)

S/N 0.16 HTS-S 0.04 3 55 U9/91 RF0 10 (generat) 40 % iW 13.81 HIS-P

+ 1.57 3 86 09/91 1$

10 (general)

S/N 0.24 HTS-S

+ 0.12 3 89 09/91 IS 10 (general)

S/N 0.24 HIS S 0.04 4 46 09/91 IS IC (general)

S/N 0.20 HTS-S

+ 0.08 4 65 09/91 15 ID (general)

S/N 0.20 HIS S

- 0.04.

09/91 TS

'80 (general)

S/N 0.20 HTS S

- 0.08 -

4 72 09/91 is ID (general)

S/N 0.24 HIS S

+ 0.08 4 78 09/91 RF0 10 (general)

S/N 1.52 His P

+13.11 4 80 09/91 15 ID (general)

S/N 0.28 HTS-S

- 0.08

'4 93 09/91 RFO ID (general)

S/N 1,34 HIS P

+16.89 4 95 09/91 is ID (general)

S/N 0.20 HTS S

- 0.04 4 96 09/91 15 - ID (generat)

S/W 0.16 His S

  • o.08 4 101 09/91 15 ID (generat)

S/N 0.24 HTS S

+ 0.12 4 105 09/91 IS-ID (general)

$/N 0.16 HIS-S 5 8 09/91 RF0 00 (generat)

S/N -

0.80 1

+13.06 5 -36 09/91 RF0 DD (general)

S/N 0.49 5

+ 0.08 -

5 61 09/91 IS 10 (general)

S/N 0.24 HTS S

+ 0.08 5 75 09/91 IS ID (general)

S/N 0.12 M1 -S "5

78 09/91 IS 10 (general)

S/N 0.16 HTS-S

- L.04

5 98 09/91 IS ID (general)

S/N 0,16 HIS-S 5 100 09/91 RF0 ID (general)

S/N 2.42 HIS-P

+12.82 09/91 15 ID (general)

S/N 0.32 CTS S

- 1.78 09/91 IS ID (general)

-S/N 0.12 Cis S

- 1.90 09/91 15 10 (general)

S/W 0.08 C15-5

- 1.94 5 108 09/91 RF0 10 (general)

S/N 2.18 HIS P

+15.79 5 1? 09/91 if ID (general)

S/N 0.16 HTS S

+ 0.12 09/91 IS ID (ceneral)'

$/N 0,28 HIS+5 3.15 6 60 09/91 RF0 10 (general)

$/N 1,60 Hi$ P

+16,84 6 ' 84 09/91 RFO 00 (general)

S/N 0.48 2

+ 0.08

')

S/N 0.20 HTS-S--

- 0.08 6 El 09/91 TS

-ID (ge-6-105 09/91 RFO OD (generat)

S/N 0.46 4 7- $4 09/91 TS ID (general)

S/N 0.28 HTS S

+ 0.20 09/91 TS 10 (general).

S/N 0.24 HTS 5

+ 0.12 09/91-IS 10 (general)

S/N 0.12 HIS-S'

+ 0.D8 7 73 09/91 is ID (generat)

S/N 0.20. HTS-S

+ 0.04 7--87 09/91 IS 10 (general)

$/N 0.20 His-S

+ 0.04 09/91 15 ID (generot' S/N 0.29 His S

+ 0.04 7 94 09/s1 TS 1D (general)

S/N 0.16 HIS-S

+ 0.04

? 110 09/91 iL 10 (general)-

$/N 0.20 HTS S

+ 0.16 09/91 is 10 (general)

.S/N 0.20 HTS-S

+ 0.12-09/91 15 10 (general)'

-5/N 0.16 WYS+S'

+ 0.12

'8 -20 09/91 is ID (general)-

5/N 0.16 HIS*$

+ 0.17 09/91 TS 10 (general).

S/N 0.24 HTS S

- 0.19

-8 41 09/91 RF0 - 00 (general) -

S/N 0.90 tis S

+ 9.12

-09/91.51 00 (general)

S/N 1.17 Cis-S

+ 9.16 B.81 09/91-15 10 (general)

$/N 0.28 HTS-S

- 0.04 9 11 09/91 RF0 00 (general)

S/N 0.84 11

+ 2.95

9. 21 09/91 RF0 00 (general) 1 % TV 0.19 6 9 29 09/91 IS ID (general)

S/N:

0.20 HIS-S

+ 0.04 9 33 09/91 RF0 00 (general)

.1 % iW 0.-23 5 9 43 09/91 RF0 10 (general)

S/N -

2.70 HTS P

+16,78

--. -. ~ ~. - ~ -..,.....- -.

~.-

~.-,---

+g c(

"*"* Dud L TUBAN(TN) (vie 3.0)**"" Monday Nwenber 9,.1992 -

08:45 AM s""* BABCOCK & 'WILCow Co. "*"* Page.

'2 Plonti-McGulkE lsNIT l'

- Steam Generator: A'

Outages:

09/91 RFO.09/91 SLV 09/91 is.

09/91 St.

4

.1 DU(RY - ATI ACHMEkl 1 INDICA 110NS Of - IMPERf ECTIONS

.y....

ROW Col. DUTAGE INDtCATION

-VALUE VOLIS LOCAll0N INCHES

.9 86 09/91 15 10 (generat).

S/N 0.20 HTS S i 0.08-

$l

-09/91 t$

10 (general)

S/N 0.20 HIS S

+ 0.04

_l 9 88 09/91 IS ID (general)

S/N 0.16 HTS-S 0.02 09/91 TS ID (general)

- S/N 0.20 His-S 0.0?

9 92 09/91 RF0 10 (general)

-40 % TW 1,81 HIS S l

09/91 TS : 10 (general)

S/N 0.32 HiS S 0.06

_l

,9 97 09/91 TS ID (general)

S/N 0.16 HIS S

+ 0,08 i

9-101 09/91 TS 10 (general)

S/N 0.20 HTS-S 0.03 09/91 TS 10 (general)

S/W 0.16 HIS-S 0.07 10 18 09/91 RF0 00 (general)

S/N 0.26 3

- 0.05 10 21 09/91 RfD 00 (general)

S/N 0.82 1 09/91 SI~

00 (general)

S/N 0.10 1 10 37 09/91 Rf D 00 (generat)

S/N 0.24 3

+ 0.08 10 60 09/91 15 10 (generali

$/h 0.16 HIS S

+ 0.07 10 68 09/91 RF0 1D (generat) 40 % TW 3.04 HIS S.

'09/91 TS ID (generat)

$/N 0.24 HIS-S

+ 0.12 09/91 TS 10 (general)

S/W 0.20 HIS S

+ 0.12 1

09/91 IS ID (genera')

S/N 0.20 HTS-S

+ 0.12 i

09/91 15 10 (generat)-

S/N 0.20 HTS-S

+ 0.12 1

-09/91 iS ID (general)

S/N 0.20 HTS-S

+ 0.08 09/91 TS ID (general)

S/N 0.20 HIS-S

+ 0 08 i

09/91 13 ID (general)

S/N 0,16 HIS-S

-+ 0.08

-l 09/91 TS 10 (general)

.S/N 0.70 HIS S

+ 0.04 09/91 TS 1D (general)

S/N.

0.08 HIS S

- 0,03 10' 70 09/91 1$

ID (general)

S/N 0.20 His S

+ 0.11 10 "76 09/91 is ID (general)

S/N 0.28 HTS-S

+ 0.12

-i 10 83 09/91 TS 10 (general)

S/N 0.24 HIS-S 0.03 09/91 TS ID (general)

S/N 0.20 HIS-S 0.03

-l 10 104 09/91 TS ID (general)

S/N 0.20 HTS-S

+ 0.12 11-22 09/91 M O 00 (generat) 1 % TW 0.14 1 -

11 57 09/91 IS ID (general)

S/N 0.28 HTS-S

+ 0.16 i

09/91 15

.1D Igeneral)

S/N 0.16 His-S

+ 0.08 -

11-61 09/91 15 lb (general)

S/N 0.20 HTS-S

+ 0.01 09/91 TS 10 (general)

S/k 0.20 HIS S

+ 0.01 11 72 09/91 RF0 00 (general) s/N 0.37 9

+34.39 11 112 09/91 15~

ID (general)

S/N 0.20 HIS S

+ 0.12 12 33 09/91 RfC 00 (general) 1 % IW 0.28 5 12 59 09/91 15

-ID (general)

S/N.

0.16 HIS S

- 1,04 12 79 09/91 TS 10 (general)-

S/N 0.32 HTS S.

12 105 09/91 TS ID.(general)

S/N 0.16 HIS S

+ 0.08 13 25 09/91 TS ID (neneral)

S/N 0.28 HTS-S

- 1.11 09/91~TS 10 (general)

S/N 0.20 HTSts 1.11 09/98 TS ID (general)

S/N' O.24 HIS S

- 1.11 13 '64 09/91 15 10 (generat)

S/N 0.16 HTS-S.

+ 0.07 1

09/91-TS

-ID (generet)

- 5/N 0.16 HTSes

+ 0.07 09/91 TS ID (general)

S/N.

0.16 HTS-S

+ 0.03 13'108 09/91 IS 10 (general)

S/N _

0.16 HIS-S

+ 0.11 l.~

14 73 09/91 TS 10 (general)

S/W 0.16 HTS S

+ 0.0/

'14 45 09/91 TS ID (general)- - S/N 0.20 HTS S

- 2.56 14 '78 09/91 TS ID.(general)

S/h 0.20 HTS-S.

+ 0.08 i

l 14 97 09/91 is 10 (generat)

S/N 0.20 HTS S

- 0.03 l-

'14 105 09/91 15 ID (gene al)

S/N 0.28 His S:

+-0.11 09/91 is ID (general)

S/N 0,20 HTS-S

- 0.01 l --

14:-111 09/91 IS !!D (general)

$/N 0.16 HIS-S

+ 0.14 15: 52 09/91 IS - 10 (general)

S/N C.24 HIS-S

+ 0.12 l'

15 65 09/91 is-10 (gener t)

S/N

,0.20 HTS-S-

- 0.04 15.83 09/91 TS 10 (general)

S/N 0.20 HTS S'

+ 0.05 t

16 29 09/91 15 10 (general)

$/N O.08 HIS S

. + 0.28 16 66 09/91-1S ID (genent )

5/N 0.12 HT54

- 0.08 h

09/91 TS ID (general)

S/N 0.12 His S

- 0.08 16 :70 09/91 SLY OD weneral)-

S/N

- 0.93 HIS P -

+16.21

6.71 09/91 TS. -ID (general)

S/N 0.24 HIS-S

+ 0.12

'16.

76 09/91 15 10 (general) - $/N 0.16 H I S 4 -

+ 0.05 16 B1 09/91 TS lb (general)

S/N 0.16 HIS S

?+ 0.14

-09/9i TS in (general)

$/N 0.28 HIS-S

+ 0.04 l~

09/91 TS ID (general)

.S/N 0.12 HTS S

  • 0.04 16 -85 09/91 15--

10 (general) -

S/N-0.20 His-S

+ 0.16 -

l.

l

q DUKt _ _ f u'4N( TM) (vie. 3.0)** ** *

  • Monday November 9, 1992'-

D8:45 AM ******'3ABCOCK & WILCO

  • Co. ****** Page-13 Plant McGUIRE LNif 1 Steam Generef ors A Dutages:

09/91 RfD. 09/91 StV D9/91 TS 09/91 51

~ uufdVI A11ACbMfNi 1.lNDICAll0NS OF _.lMPERf fCTIONS -

CROW COL C4fA(A INDICAil0N VAluf VOL15 LOCAllON INCH [$

16 92 09/91 f5 ID (general) - 'S/N 0.16 HIS>S

- 0,08 16 95 09/91 RfD 10 (general)

S/N 1.53 HIS-P

+ 9.77 16 111 09/91 StV ID (general)

$/N 11.63 HIS P

+ 8.50 17 100 09/91 iS 10 (general)- 5/N 0.20 HIS S

- 0.03 D9/91 15--ID (gener6l)

S/N 0.20 HIS S

- 0.ul 1P 60 09/91 15 10 (general)

S/N 0.16 H15-5

- 0.05 09/91 15 10 (general)

S/N 0.20 HTS S

'O.01 0.07 18 61 D9/V1 f5 10 (general)

S/h 0.12 HIS S 09/91 15 ID (general)

$/N 0,04 HIS s

- 0,14 18 C2 09/91 IS iD (general)

S/N 0.12 HTS S

- 0.08

-18 86 09/91 RfD 10 (general) 58 % TW 9.99 HIS P-

+17,17 09/91 15 10 (general)

S/N

--0,39 His G

3. 73 09/91 1$- ID (gener4l)

$/N-0.20 HIS S

- 3.89 09/91 15 ID (general)

./N 0.20 HIS S 3.89 09/91 TS ID (general)

S/k 0,16 HIS S

- 3.93 3.93

.i 09/91 !$

ID (generat)

$/N 0.16 HIS S 19 58 09/91 is ID (general)

S/W 0.16 H T S S '

+ 0.06

19. 611 09/91 15 ID (general)-

S/N 0,16 dfS-S

  • 0.01 1'

B4 09/91 is ID (generat)

S/N 0.22 HTS-S

- 0.13 09/95 15 ID (Dencro')

S/W 0.13 His S

- 0.17 70 85 09/91 TS 10 (gent ral)

S/N 0.39 HIS S

- 3.28 20 89 09/91 iS 10 (Generst)

S/N 0.22 HIS S

  • 0,09 09/91 15 10 (general)

S/N 0.17 His-S

+ 0.09 09/91 IS 10 (general)

S/k 0,17 HYS s

  • 0.04 09/91 15 10 (generat)

S/N 0.17 HIS S

+ 0.04 21 47 09/91'Rf0 00 (generat)

$/k 0,:16

+10.27 09/91 51 00 (general)

$/N 0.?9 6

  • 11.10 21 64 09/91 Rio.ID (general)

S/N 1.79 HIS P

+16.95 09/91 RfD ID (general)

S/N

'2.60 HTS P

+ 17. 87 09/91 NFO 10 ()oneral) s/N 1.15 HIS P

+18.04

. 09/91 IS ID (generat)

S/N 0.12 HIS S 0.12 05/91 15 ID (general)

S/N 0.16 HTS S

- 1.?2 09/91 15 ID (general)

S/N D.16 MTS-S

- 2.17 09/91 is ID (general)

S/N 0,16 HTS S 2,21 09/91 is 10 (general)

S/N-0.51 HIS S 2.99 09/91 TS 10 (general).

S/W 0.20 HIS S 4

3.15 09/91 15 lD (general)

S/N 0.24 HTS S 3.15 21 72 09/91 IS 10 (gtesral)

S/N-0.20 HIS-S

  • 0.04 21.75 09/91 t$

10 (general;

$/N 0.16 HYS S 14.18 28 78 09/91 WFO ID (general)

S/N 1.61 HIS P

+

21 82'09/01 RF0 10 (generat)

S/N 2,50 HIS P

+13.02 09/91 IS 10 (generat)

S/W

.0.12 Hl$ S 0,32 13:30 21 i05 09/91 RF0 ID (general)

S/N 0.97 HIS + P

+

-72 54 09/91 IS ID (generat)

S/N 0.20 HIS-S 0.12

+

22 72 09/91.15- -10 (general) -

$/W 0.16 His S-

+-0.02-22 86 09/91 IS ID (general)

S/N 0.20 His-S 4.41 23 59 09/91 RF0 00 (general)

S/N'

.1.38 16

+ 6.55 23' 65 09/91 IS 10 (general)

S/N 0.20 H15-5 0.05 23 68 09/91 is 10 (uencrat)

S/N 0,24 HIS S

- 0,19-

?$ 70 09/91-is 10 (general)

S/N 0.20.HIS S

  • 0.04 24.56 09/91 IS ID (general)

S/N 0,16 Hr$-5

+ 0.08 0.16 57 09/91 15 tid (general)

S/N -

.0,24 HIS S

~~+

24 -61 09/91 RF0 ID (general) 40 % TW 2.73 His S 09/91 is-ID (general)

S/N 0,24 HTS S

  • 0.15 09/91 15 10 (general)

S/N J.20 MTS-S

+ 0.11

-74 76-09/91 RfD 00 (general) t % TW 0.30 1 24 78 09/01 RF0 00 (general) 19 % TW 0.14 5 09/91 SI. CD (general)

S/N 0.53 5 0.14 24 '100 09/91 15 ID (generat)-

S/N 0.16 NIS-S 0.01 24 105 0~/91 15 110 (general)

S/N 0.20 a15-5

+ 0.12 25 - 67 09/91 15 10 (generat)

~ S/N 0.16 HTS S

+ 0,15 2

09/91 75

-10 (general)

S/N

-0.24 HYS S 2d 46 09/91 ef 0 ID (general)

S/N 2.81 HIS P

. + 0.12

+10.51 c 16 fM1 09/91 15-10-(general)

'S/N 0.16 H!S-S.

  • 0,13

.09/91 is 10 (general)

-s/N

= 0.16 HIS-5

+ 0.06 g

26 67 09/91 EF0 OD WEAR 40 % TW 2.36 Avn3 26-79 09'91.is 19 (general) -

$/N 0.12 HTS S

- 0.12 a

,,,..,,, ~ _, _ _

-.. _ ~ _, -. -..

..n-.

- ~ -

--- - ~

u.-

~i t

i i

,,; : a -- {---

'Dutt' TUBAN(TM)-(VER. 9.0)****** M0"UdV "* ** *

Flan't
McGutet UNil 1

' Steam Generator A=

~

1Dutages 09/91 Rfo 09/91 SLv 09/91 is

-09/91 SI QUE RY l A11 ACHMENI i lhD!CAf!DNS Of IMP [Rf(CllDNS.

~

b PDV COL DulAGE I NDICAl l0N VALUE.

Votis LOCAll0N INCHES

+

4.......

.... +...........

26. o2 09/91 RfD ID (general)

S/W

$.24 HIS-P

+15.89 s 26 64 09/91 970 10 (general).

S/N.

f2.61 NfS P

+13.60

. D9/91 RfC 10 (general)

S/h 3.88 His P

+14.58

, 27 - 39 09/91 R 8 0 00 WEAR-14 % TW 0.49 AVB2 27 65 09/91 is ID (general)

S/W 0.16 HIS+5 09/91 15 ID (general)

S/N 0.16 NTS S 09/91 15 (D (general)

$/N 0.12 HIS S

- 0.D4 i

2/.68 09/91.15-ID (gener al)

S/W 0.20 MfS S

+ 0.12 09/91 IS-10 (general)

S/W 0.04 MfS $

4 0,sa l

D9/91 IS ID (general).

S/N 0.12 HIS-S

  • D.04 2 7 --Il 09/91 Rf D 10 (general)

S/N 1.26 C15 P

+15.55 09/91 SLv OD (general)

S/N 1.60 HIS-P

+ 1.83

- 27 /$ 09/91 TS 10 (general)

S/N 0,16 HIS S

+ 0.07 D9/91 15 10 (generat)

S/h 0,21 HTS-S

+ 0,07 27 76 D9/91 IS ID (general)

S/N 0.20 MTS S

  • 0.04 09/91 is ID (general)

S/N 0.08 HIS-S

+ 0,04 ID (general)

S/N 0.16 HIS S

+ 0.04 09/91 16.

09/91 15 lD (general)

S/N 0.16 HIS S

+ 0.04 09/91 IS ID (general)

S/N 0.08 HIS S

- 0.04 n:

_27 77 09/91 RfD nD WEAR 16 % TW -

0.57 AvH1

.09/91 15 ID (general)

S/k 0.24 HIS S 0.06 09/91 15 10 (general)

S/N 0.16 HIS-S

- 0.13 09/91 15 10 (general)

S/N 0.16 H15 5

- 0.13 09/91 it ID (general)

S/P 0.16 HTS 3

- 0.13 09/91 IS ID (generat) s/W 0,16 HTS-S 0.17 28 ' 43 09/91 Rf D DD WEAR 21 % iW 0.85 Av82

- 28 67 09/91 Rf0 0D WE AR 19 % TW 0.74 AV82 28 75 09/91 Rio DD WEAR 16 K TW 0.59 Avel 28 76 0V/91 iS 10 (generat)~

S/N 0.16 HIS 0

- 0.20

?B 51 09/91 RF0 00 WEAR 19 % TW 0.70 Aval 29 52 09/91 RF0 00 WEAR

$0 % is 0.70 AVB2

- 29 62 09/91 15 LD (general, S/N 0.16 HIS S 0.04 29 64 09/91' IS ID (general)

'/N 0.16 HIS S

'09/91 15 ID (general)

S/k 0.16 L15 S 09/91 IS ID (generat)

S/N^

0.12 HIS+5 0.04 09/91 15 ID (general)

S/N 0.12 vin 5

- 0.04 29 65 99/91 RFO ID (general)

S/W 1.45 !? *

  • 10.61 29 66 09/91 15 ID (general)

. S/N-0.20 HTS.b.

+ 0.08 09/91 15 to (general)

S/4 0.20 His S

  • 0.08
29. 68 09/91 TS 3D (genernt)

S/N 0.16 HTS S

  • 0,12

'29 ' 70 09/91 15 ID (general)

S/N 0.37 HIS S 29 71 09/91 TS tb (generat)

S/N.

0.08 HIS S

+ 0.08 24 77 09/91 is 10 (generol)

S/N 0.12 HIS S

- 0.20 29'78 09/91 IS ID (general)

S/N 0,12 HTS-S 0.12 129 80 09/91 RFU ID (gener.4)

S/N -

1.59 Mit P-

  • 13.04.

D9/91 S1 ID (concret)

S/N' 1.94 HIS P

+11.83 29 81 D9/91 IS-10 (generat)

S/N 0.12 HTS S 0.08 29 34 09/91 IS

-10 (general). S/N 0.28 HIS S-

+ 0. 04 -

D9/91 YS ID (general)

S/N 0.20 HTS S

- 0.04:

29 94 09/91 RF0 00'(generat) 16 % TW 0.79 9

  • 5.88 ~

79 104 09/91 TS ID (peneral)

.$/N 10.16 HIS S

+ 0.04'

- 30 41 09/91 RfC 00-utAR

.19 % TW 0,71 Av83 130- 61 09/91.I5. 10.(general)

S/N 0.28 HIS 3

+ 0.19' 09/91'IS ID (~ neral)

' S/N 0.16 His 5

+ 0.15 30 68 09/91 is_ 10 (genera')

S/N 0.28 ATS*S_

+ 0.16

-- 3 0 71 09/91 is-ID (generat)-

S/w 0.20.His-S

+ 0.04

30. 72 09/91 RfD DD WE AR 11 X TW 0.63 AVR3 3n 74 09/91.T5 10 (general)

S/W 0.12 HIS-S 0.16 30 78 09/91 RfC 10 (general). S/N 0;16 His S

- 0.20 50 7/ 09/91 iS iD (generat)

S/N

.1.45 h!S P

+12.87 09/91 15 ID (gerw?ral)

S/N 0.32 HIS $

2.26 09/91 is 10 (generat )

S/N.

. 0.28 HIS S

- 2.26 10 81 09/91 TS - ID (genernt)

S/N -

- 0,28 MfS S 09/91.75" ID'(general)

S/N 0.16 HTS S-

- 0.04

-.10' R3 09/91 is 10 (general)

S/N C.20 HIS S

  • 0.12 09/91 is ID (generat)

S/N

.0.12 His S

-+ 0.08 09/91 15. ID!(general)

S/N 0.12 M'$*S-

+ 0.08 4

+

t w

e wy

'n s'm-v

=

q w

-YM W

_.m m

m-

. 4-g-

Dut! - 10B AN ( T H ) (VE R. 3.0)* * * * *

  • Monday N ovember 9, 1992 J8:46 AM ****** BABCOCK & WILCOX Co. ****** Page.

5

~******

Plant: McGUIRE UNif 1 Steam Generator: A Datages:

09/91 RfD 09/91 SLV 09/91 is 09/91 Si

+

00ERY: AliACHMENT 1 INDICAflDLS OF IMPfRFECil0NS 4.........

ROW COL DU1 AGE INDICATION '

VALUE VOLIS LOCAllDN IkCHES Oh/91 hi 10 (generbk)

S)N 0.16 His S b$bb 09/91 15 10 (general)

S/W 0.12 HIS;S

+ 0.04 31 41 09/91 RfD 00 WEAR 20 % TV 0.75 AVB2 31-44 09/91 RfD 00 WE AR 22 % TW 0.91 AVB3 31 72 09/91 IS. ID (generot)

S/N 0.24 HTS S

+ 0.11 09/V1 15 10 (general)

S/N 0.16 HTS-S

+ 0.11

-31 79 09/91 15 la (gereral)

$/N 0.20 HTS S 0.04 31 89 09/91 is ID (general)

S/W 0.04 Hib-S

+ 0.34 31 98 09/91 'S 10 (general)

S/N 0.16 HIS S

  • 0.18 31 99 09/91 is ID (general)

S/N 0.24 MfS S

+ 0.21 39 09/91 Rr0 _ 00 -(general)

S/N 0.43 2

+ 0,20 32 s0 09/91 RF0 00 (general)

S/N 0.50 1

  • 0,05 09/91 SI 30 (general)

$/N 0.15 i 32 67 09/91 IS ID (generni)

S/N 0.32 HIS-S

+ 0.16 32 101 09/91 15 ID (general)

S/N 0.20 HIS S

+ 0.18 33 42 09/91 RfD 00 (general) 77 % TW 1.30 8

+ 1.44 33 50 09/91 If 10 (generat)

S/W 0.04 HIS S

- 0.08

-33 52 09/91 TS ID (general)

S/N 0.16 HTS S

+ 0.D4

- 33 $8 09/91 15 ID (general)

S/N 0.24 HTS S

+ 0.08 33 59 09/91 RfC 00 (generat)

S/N 0.55 3-

+ 0.08 33 94 09/91 'S 10 (gener al)

$/9 0.16 HIS-S

+ 0.08 09/91 15 10 (general)

S/N 0.12 HTS-S

+ 0.08 09/91 IS 10 (general)

S/h 0.12 His S

  • 0.04 34 46 09/91 RfD 00 (general)

S/W 0.34 1 09/91 St OD (general)

S/N -

0.40 1-34 47 09/91 Rfo 00 (general)

S/N 0.39 1 34 67 09/91 iS ID (general)

S/N 0.16 HTS S

+ 0.01 34 86 09/91 is ID (general)

Sin 0.12 HTS S

- 1.06 09/91 15 10 (general)

S/N 0.16 HTS-S

- 1,06 09/91 IS 10 (general)-

5/N 0.08 HIS S

- t.10 35 40 09/91 RF0 00 WEAR 12 % TW 0.40 Av83 35 44 09/91 RfC 00 (general)

S/N 0.52 8

+ 1.66 35 55 09/91 RfD OD WEAR 21 % IW 0.85 AVB1

35. 59 09/91 15 10 (generat)

$/N 0.16 MTS-S

  • 0.11 35 71 09/91 Rf0 00 (generat) 20 % TW 0.57 8 -

+ 1. 79 09/91 St 00 (generat)

S/4 0.30 8

+ 1.74 35 72 09/91 15 10 (general)

S/N 0.04 CIS S

+ 0.83 35 74 09/91 IS 10 (general)

S/N.

0.16 HTS +$

- 0.05 09/91 is ID (general)

S/N 0.16 His S

  • 0.Dr D9/91 is 10 (generat)

S/N 0.12 HTS S

- 0.07

=09/91 15 10 (general)

S/N 0.12 HTS-S 0.07

35. 81 09/91 Rio ID (generat)

S/N 1.63 CTS P

+ 2.95 35: Je 99/91 TS ID (general)

$/h

'O.16 HTS S-

+ 0.09 36 si 09/91 Rio 00 WEAR 12 % TW 0.40 Avel 36-.35 09/91 RFC 00 WEAR 17 % I" 0.65 AVB2 36.60 ro/91 RfD 00 (genera.)

S/N 0.53 16-

- 36' 77 09/91 TS ID (general)

S/N 0.32 HTS-S-

- 0.82 09/91 15-ID (generat)

S/N 0.3k' HTS-S 0.82 36; 81 09/91 is 10 (general)

$/N-0.12 His-S

+ 0.11

36. 85 09/91 IS ID (general)

S/N 0.28 HTS S

--0.49 09/91 15 - 1b (generat)-

5/N.

0.20 HTS-S.

- 0.52 09/91 IS 10 (general',

S/N 0.16 NTS*S

- 0.52 09/91 is ID (genera-)

S/N 0.24 HTS *S 0.56-09/91 TS It (generat)

S/N 0.12 HTS *S 0.56-09/91 TS 10 (generat)

S/k 0.16 HIS -

+ 0.60 -

09/91 15 10 (general)'

.37 16 09/91 RfD 00 WEAR ~

S/N 0.16 HTS S

+ 0.60 -

17 % iW 0.62 AVB1 09/91 RF0 OD WE AR 19 % TW '

O.72 Av82 09/91 RF0 00 WEAR 19 % fu 0.72 AVB3 37 29 09/91 RfD ID (general)

S/N 5.61 HTS P

+ 9.77 37, 69 09/91-15' ID (general)-

S/4 0.20 HTS S

+ 0.00 37 71 09/91 RF0 00 (general)

S/W 0.11 5

+ 0.11 3 7. ' 76 -09/91 R F0 00 (general)

S/N 0.18 16 37. 62 09/91 RIO DD (general) s/N 0.15 17

+ 0.02 18 47 09/91 RF0 '00 WEAR 16 % TW 0.56 AVB2

38. 78 09/91 Rfo' to (general)

_S/N 5.36 HTS S-0.77 L

09/91 is-10 (general)

S/N 0.04 HTS-S 0.91 h

y y

-w-+,

r w-.yw y

n

.,e v.-.

r a

~

  • ""* Dwt S 10BAE(TM) (vtR. 3.'0)* 5"** Monday Novernber :.9, 1992

'08:47 AM **"** BAsc0CK g. WlEC0x CO. '""' Page (6;

Plants McGUIRE UNIT 1 Steam Cencretors A' Outo9est-.09/91 RF0 09/91 $EV 09/91 TS

'09/91 $1 OutRYs'ATTACHMINT 1 thDICA 10NS OF IMPERFECliONS

! ROW EOL OUTAGE INDICAil0N VALUE VOLTS EDCATICN lNCHES 09/91 15 10 (general)

$/N 0.04 HTS s 0.95

- 09/91 15 10 (general)'

S/N 0.04 Hii S

- 0.95 38 95 09/91 IS - ID (general)

$/N 0.16 Hf5 5

+ 0.08 39 '58 09/91 *S 10 (general).

S/N 0.16 His-$

+ 0.14 40 % TW 2.42 HTS S

.39 72 09/91 RF0 10 (generat). $/N 0.35 His-S

+ 0.16 09/91 15 ' lD (general)

.40 51 09/91 RF0 00 WEAR 30 %.W 1.42 Av81 40 54 09/91 15 10 (general). $/N 0.16 HIS S

+ 0.12 40.72 09/91 RF0 00 (general)

$/N 0.51 6

40. 81 09/91 15 10 (general)

's/N 0.16 HIS s

+ 0.0' 09/91 TS ID (general)

S/N

'O.16 H1$ $

+ 0.02

'40 S6 09/91 RF0 00 WEAR 16 % TW 0.60 AVB1 09/91 RF0 00 WE AR 16 % TW 0.59 Avec 09/91 RF0 00 WEAR 21 % TW 0.85 AVB3 41 45 09/91 RFO 00 (general) 14 % 1W J.66 10

+13.06 41 54 09/91 RF0 00 WE AR 19 % TW 0.72 Avai 09/91 RF0 00 WEAR 26 % TW 1.10 A%

41. 59 09/91 RF0 00 WEAR 31 % TW-1,46 AVh 41 85 09/91 TS ID (general)

$/N 0.24 HIS S 0.87 42' 25 09/91 RF0 ID (general) 18%YW 1,40 13

+ 1.82 4? 55 V9/91 RF0 00 (generat) s/N 0.28 1

  • :?

09/91 51 ' (0 (general)

S/N 0.06 1

+ 0.03

.42 57 09/91 RF0 00 WEAR 19 % TV 0.72 Av81 42 80 09/91 TS 10 (general)

S/N 0.16 MTS S

--1.18 43 57 09/91 RF0 00 WEAR 26 % TW 1.12 AVB1 43 80 09/91 15 1D (9cheral) s/N 0.20 HTS $

+ 0.24-45 n6 09/91 RF0 00 WEAR 12 % TW 1.21'18 46 59 09/91 FF0 00 WEAR 8 % TW 0.77 16 46 :72 09/91 RfD 00 WEAR 16 % 1W 1.29 18 47 56 09/51 RFO. 00 WEAR 30 % TW 3.71 16 47 5A 09/91 RF0 00 WEAR 20 % tw 2.32 14

-47.-59 09/91.RF0 00 WEAR 13 '4 TW

-1.34 16 09/91 RF0 00 WE AR IB % 1W 1.88 14-

.47 60 09/91 RF0 00 WE AR 10 % TW z1.00 14.

09/91 RF0. 00 WE AR 17 % TW 1,77 16

- 4 7. 61 09/91 R F0 - 00 WE AR -

20 % TW 2.16 16 09/91 RF0 00 WEAR 15 % TW 5.55 14

47. 64 09/91 RF0 00 (gener at ) '

61 TW 0.39 2

+ 5.J ?

47 77 09/91 RF0 00 (general) 17 %'TW 0.79 16

- 0.1-

~48 38 09/91 RF0 00 WEAR.

13 % 1W

~1.24 16 48 41 09/91 RFC 00 WEAR 13 % iw 1.23-16 AS - 53 09/91 RF0 00 WE AR 14 % IW 1.27 17 48 54 09/91 RF0 00 WEAR 27 % 'W 2.96 16 48 55 09/91 RFo 00 WEAR 16 % TV 1.54 16 48 56 09/91 RF0 CO VEAR

.20 % IW 2.08 12

~

09/91 RF0 00 WEAR 25 % TW 2.76 14 09/91 RF0 00 WEAR 21 % TW 2.10 16-D9/91 RF0 00 WEAR 13 % IW 1.25 17 4862 09/91 RF0 00 WEAR 22 % TW

'3.12 16 49 37 04/91 RFO'- 00 VEAR 10 % YW 0.93 16 4

49. 38 09/91 R FO ' 00 WLAR 19 % TW 1.97 16 40 40 09/91 'RF0 00 WEAR-21 % TV 2.*6 16 09/91 RF0 00 WEAR 17 % TW 1.71 17

. 49 41 09/91 RF0 00 WEAR.

21 % TW 2.16 16 49 42 09/91 RFO 00 WEAP 24 % TW 2.59 16 43 09/91 RF0 -00 WEAR 21 % TW - 2.19 15' 09/91 RF0 CD WEAR

- 22 % TW 2.30 16 09/91 RF0 OD '4 AR 19 % TW 1.96 17 49 50 09/91 RF0 00 WEAR 22 % 1WE 2.29 16 49-53 09/91 RFC 00 WEAR 14 % TW 1,30 12 09/91 RF0 -Oc WEAR

.17 %~TW 1.61 14.

09/91 RF0 00 WE Ar -

28 % TW 3.24 16 09/91 RF0 -00 WEAR 23 % TW.

2.43 17 09/91 RF0 00 WE AR 23 % TW 2.43 19 i '

49 54 09/91 RFO 00 WEAR 21 % TW

'2.16 16 09/01 RF0 00 WEAR 18 % TW' 1.83 17 49. 5 7 09/91 R F 0. 00 WE AR -

.17 % TW 1.64 14~

r s

.r--e-yw,'

'rr f

u r-w q

+

._m_

~

m s

I. :

? :. -

'****** Dutt tunAN(TM) (vta. 3.0)****** Monday November 9, 1992 08:47 AM * * * * *

  • 8ADCCct & Wit C0/ Co. * * * **
  • Page -

7L

- - - Plant PtCulpt UNif 1

. 09/91 15 09/91 $1 0vtages:

09/91 RfD -09/91 CLV' Steam Generatort A 1

00lRY; AllACHMfNT 1 INDICAlloNS of IMP (RittilDNS

..n ADW COL OUVACE INDICAfl0N

-VALUI VOL15 LOCAilON INCH ($

09/91 RF0 00 WL AR.

23 % TW

?.37 16 09/91 RFO ~00 WEAR' 19 % IW~

1.87 17 49 66 09/91 IS ID (general) 5/W 0.28 CTS 5

+ 1.14 09/91 15 ID (geterat) s/N

.0.08-C15 S

+ 1.10

- 49 67 09/91 15 ID (gerreret )

S/N 0.12 Cit s

  • 0.95 49 68 09/91 15 10 (General)

$/N 0.12 C1. 5

' O.91 49 69 09/91 15 10 (general)

S/N.

0.12 CTses

.

  • 1.02 49 70 09/91 15 ID (general)

$/N 0.12 Cis S

  • 0.95 49 71 09/91 15 10 (general)

S/N 0.20 Cis S

+ 0.91 49 15 09/91 15 ID (general)

$/N 0,12 Cf5+b

+ 0.83 49 74 09/91 RfC 00 WE A8 26 % fw 2.98 16-49-76 09/91 RfD 00 (general)-

$/N 0.77 16 0,25 10lAL TUBES FOUND 269 10fAL INDICAflONS FOUND a

4)4 t

L i'

i l -

F I.

L s

v s

e

~w a,

a v

<n,-

4 r,-

_m7.__-_-.,

_m

. > ~. - - -...

. - ~. _ _

-e_

,r

.+:

4 DUKf TUGAN(IH) (VER. 3,0)* * * * *

  • dotday Novemt.cr ' 9,-1992 08:52 AM ****** PABCOCK & WILCox co. ****** Page 1

-- Plant i:McGUIRt UNil i

$ team Generator 8 C

ioutages

'109/91 *f0 09/91 stv 09/21 is 09/91 sl i-Guter s AllACHMf NT '1,1bulCAlltm5 or IMPERittilDNS -

........................ ~.. -

ROW C 1 00 fact INDicAitow VALL!r -

'vot15 LOCA11)N INCHfS.

2 4 09/91 RfD lo - ( gerer a t )

$/h 1.92 HIS-P

+ 5.63 2 26 09/91 is ID (gencrat)

S/N 0.24 HTS-S

+ 0.24 0.20 09/91 15 10 (gener al) 5/N 0.16 HIS S

+

2 39 09/91 Rf0 10 (general)

S/N 11.84 i:TS P

+ 5.19 09/91 f5.10 (generat)

$/9 0.04 His 5 0.08 2 ' 4 7 0?/91 R F D ID (genocal)

S/N 18.59 HIS P

  • ?.57
2. 56 09/91 15 ID (generat) 5/N 0.12 HTS S'

- 0.04 09/91 1$

ID (general)

S/W 0.12 HTS-S

- 0.04 2 61 09/91 TS 10 (generet)

S/N 0.16 His-S

+ c 04 2 94 09/91 RF0 lb (general) 65 % 1W-2.11 HTS P

+1).70 9.17 3

1 09/91 RfD ID (general) 65 % IW 6.51 H15 P

+

3 5 09/91 of0 10 (generat)

S/N 17.83 HIS-P

+10.53 3 24 09/91 RF0 00 (generat) 19 % TW 0.15 4 8.D1 3 47 09/91 RF0 ID (generat).

45 % TW 5.81 sis-P

+

6. 73 31 95 09/71 Rfo ID (genernt)

S/N 2.39 HfS-P

+

09/91 RTO ID (general) t/N 1.84 HTS P

+ 6.20

+

-3 97 0V/91 Rio 00 (general) 1 % TW l.34 7

+ 9.41 09/91 51 00 (general)

S/N 4.41 7

+ 8.40 3 98 09/91 Pfo DD (general) 4 % IV 0.30 4

+$1.48

    • 5

$/N 0.17 4

+11.60 09/91 St 00 (g 4

i 09/91 kr0 ID (ger.

%/h 10.31 HTS P.

+ 9.33 l

4 15 09/91 15 ID (gence al) 5/N 0.24 HIS S 0.50 4 78 09/91 15 10 (genero!)

S/W 0.24 dis s 0.91 4_102 09/91 15 ID (general)

$/N 0.16 Hf 5 E -

+ 0 CS F

5-6 09/91 15 10 (general)

S/N 0.16 HfS 5

  • 0.20 09/91 IS ID (general) s/N 0.12 HIL S.

+ 0.12

'5 7 ^9/91 TS ID (general) h/h 0.12 MfS S

  • 0.16 5 76 09/9# RfC 00 (generat)

$/N 3.64 4

+11.48 09/91 51 00 (general)

S/N 1.48 4

+11,56 6 34 09/91 RF0 10 (genera')

5/N 2.99 His P

+11.36 6 35 09/91 15 10 (generat) s/N 0.2d. HTS S

+ 0.20 6

'9 09/91 is ID ggene*al)

- s/N 0.16 his s

-6 42 09/91 *S ID (general).

S/N 0.12 Nf5-5 6 45 09/91 RF0 lD (general)

~ S/N 2.21 H)S P

+12.11 6 53 09/91 TS

.ID (generat)

$/N 0.20 HIS S.

+ 3.20 6 90 09/91 fr ID (general) 0/N 0.20 His s

-/ 2 09/91 RF0 ID (generat) 69 % TW 9.21 His-P

+ 9.14 7 9 09/91 is 10 (generat)-

-$/N d.12 WIS 5

+ 0,03 5/N 0.16 His 5

- 2.85 7 22 09/01 IS ID (generat)

-S/N O.12 HTS 5

+ 2.85

-09/91 is ID (generat) i-

-09/91 15 10 (generat) t/N 0.16 HI5 S

- 2.85 09/91'T5 10 (general) s/N-0.16 His S 2.85 09/91-IS 10 (general) 5/N 0.16 HTS S 2.85-09/91 is 10 (generat) 5/N 0.12 H15-5 2.09 7 23 09/91 R50 10 (generat) 48 % IV 6.55 HI5 P

+17,18 5

7 29.09/91 RfC 10 (general) 80 % IW 9.60 His P

  • 10.57 7 42 09/91 RF0 ID (general) 40 % IW 4.93 His P-

+17.22 7 78 09/91 RF0 lD (generalJ 40 % 1W 3.72 HTS $

09/91 is ID (gencial) s/N 0.20 HIS-S

  • 0.12 35 09/91 1$

10 (generat)

S/W

_ 0.16 HI5-S

  • 0.12

_B

+

8 41 09/91 15 10 (gerierat) s/N 0.16 HTS--S

  • 0.16 8 46 09/91 RF0 10 (general) 55 % TW ~

6.45 HIS'P

+16.18 8 56 09/91.RFO. ID (generat) 43 % TW 7.45 Nf 5 P

  • 14.18-i 8 %8 D9/91 970 ID (genernt) 40 % fW 4.69 HIS-P

+15.35.

8 - f>8 09/9. R F0 10 (general) 40 % TW 5.76 HIS 5 09/91 RF0 00 -(gerwrat)

S/N 0.48 2

+ 0.13 09/T'. f*

10 (general)

S/N 0.12 HIS-S

+ 0.16

-09/91,66

-1: :generats

. 5/N D.12 Hi$*$

+ 0.16 09/91_TS ID (generat) 5/w 0.32 Hf5-5

+ 0.12 09/91 IS. ID (general)

S/N 0.12 His S

+ 0.12 09/91_15 ID (neneral)

$/N '

O.16 HIS 5

+ 0.12 t

'09/91 'IS ID-(generat)

- $/N -

0.28 HTS S 0.08 4

t

'09/91 is. 10 (generat)

S/N 0.04 HIS 5

+ 0.08 09/91 IS ID (generat)

S/N 0.24 Hi$*$

..+ 0.04 09/91 TC 10 (general)

S/W 0.04 HTS S 0.16 09/91 01-00 (general) 5/N _

0. 64 2 i 69 09/91 RfC - 00 (generat )-

63 % TW 0.72 2 -

-+ 0.05 d

j'

+

r

-e m

  • 4+-W W
  • FYa e

e96 s r

q-p 7

W7 8em*t 7--r D

e...

.. - - -. ~ ~~.._.

-~ ~ -..,

-..-a r,.l' W:

-~*"") ( urti f ue AN(TM) (VE R. 3.0)***"a Monday Noventer 9, 1992.

08:52 AM * ** * *

  • BABCUCK & Wi t COX CO. '"*" Page

" 2 Plants'McGUIRE UNIT 1

' Steam Cenerator: 8 1

1 Outages:

09/91 Rfo. 09/91 SLV: D9/91 15--

09/91 $1 4

i QUiRV[ ATTACHMENT QL INDICATIDNS Of IMPERf ECTIONS FJW COL DUT AGf IkDICAllON VALUE VOL15 LOCAfl0N INCHES

- 09/91 $1 OD (general)

S/N 1.69 2 9 3 09/91 Rto ID (generat)

S/W 1.38 HIS P

+ 7.31 9 67 '49/91 15 10 (general)

S/N 0.22 HIS S

+ 0.18 10 37 09/91 IS 10 (generat)-

S/N 0.?0 CTS S

+ 0.16 -50 09/91 RF0 10 (generat)

S/N -

2.44 Hr$ P

+14.80

. l

- 10 64 09/91 TS ID (generat}

S/N 0.22 HIS S 4 0.04

~10 65 09/91 RF0 10 (general)

S/N 1.58 HTS-P

+ 4.70

.l 09/91 IS ID (generst)

$/N 0.14 Hi$a$

0.04 11 30 09/91 RF0 10 (general)'

$/N 4.56 HIS*P 5.87

+

11 $? 09/91 RfD 10 (ganfral)

S/N 2.93 HIS P

+10.94 i

11 61 09/91 is ID (generat)

S/N 0.1? HTS S 0.04 11 79 09/91 is

_ID (general)

S/N 0.16 HTS-S

- 2.10 09/91 IS ID (general)

S/N 0.71 HIS-S 2.22

=

09/91 IS 10 (general)

S/N 0.35 HIS-S

- 2m22 11 86 09/91 #fo 10 (general)

S/P 9.06 HIS P

+ 17.95 09/91 IS 10 (general)

S/N 0.35 MIS-S

- 3.01 09/41 15 10 (general)

S/d 0.32 HIS $

- 3.01 09/9' iS 1D (gercral)

S/N 0.32 Hrs S m 3.01 09/91 IS 10 (general) 1/N 0.20 MTS S

- 3.01 09/91 15 ID (general)

^ S/N 0.28 HTS S

- 3. 04 09/91 ',

ID (general)

S/N 0.20 MIS-S 3.04 11 89 09/91.

ID (general)

S/N 0.28 HTS S 2.33 11 99 09/91 '"

ID (general)

S/N 0.20 Mr$ S

- 0.2G 11 102 09/91 Th ID (general)

S/W 0.20 HTL-S

- 3.67 09/91 is ID (general)

S/N 0.20 MIS 5

- 3.67 12 18 09/91 Rio 10 (general)

S/N 4.75 HIS P

- *12.06 12 -29 09/91 RF0 ?O (general) 74 % TW 8.48 HIS-P

+ 3,07 12 74 09/91 TS ID.(general)

$/N 0.12 HTS S

- 0.04 12 TS 09/91 TS 10 (general)

S/N 0.12 HI4-S

- 0.04

+

I? 84 09/91 15 10 (general)

S/N 0.16 HIS-S

- 3.07

-13 ' 5 09/91 Rfo DD (wsnera:)

S/N 0.35 2

+ 0 15 13 41 09/91 SLv ID (generat)

Sin 6.20 HIS-P

+ 7. 75 13 47 09/91 RF0 ID (gene.at)

S/N 4.72 HTS P

+ 4.12 13 82 09/91 is ID (gerarat )

S/N 0.35 HIS-S

- 0.39 13 98 09/91 R70 10 (general)

- S/N 17.48 His p

+ 1,64 13 106 09/91 Flo 3D (genneel)

S/N 0.13 1 0.03 14 28 09/91 TS 10 (general)

S/N 0.28 HIS S 1.10 i

U9//1 f5 10 (general)

S/N 0.20 MfS S 1,14 09/91 15 10 (general)

S/N 0.20 HIS S

- 1.18 09/91 IS 10 (general)

S/W 0.20 HTS-S

- 1.18 09/91 15 10 (general) r iN -

0.16 HIS-S 1.18 09/91 TS: 10 (genernt)

S/N 0.16 HIS-S

- 1.18.

09/91 13 ' 10 (gercrat)

S/N 0.04 HTS-S

- 1.22 14-34 09/91 Rr0 00 (general)

S/u 0.35 2

-

  • 0.02 14 41 09/91 RFO ID (general)

S/N.

3.29 HIS-P

  • 13.90 14 42 09/91 RFO ID (general)

S/N 3.43 HIS P

  • 16.97 14 46 C?/91 TS 10 (general)

S/N 0.16 His-S

+ 0.08 09/91 TS 10 (general)

S/N-0.12 HIS-S 1.97

- 14 47 09/91 RF0 iD (Denernt)

S/N 7.68 HIS P

.+11648

  • 5.55 1

D9/91 RFO

.fD (genera!)

Ssd 5.24 HIS*P 09/91 RF0 'ID.(genetc()

S/N 9.37. HTS-P

+12.43 14 - 68 09/91 15 10-(ge>>ral)-

S/v 0.24 uts S

- 1.55 14 73 09/91 af0 DD- (general)

F/N 0.37 3 0.08

+

09/9 $1 00 (general)

.5/4 0.38 3 14 78 09/91 IS

-10 (gen? rat ).

S/N.

0.12 HTS S

- 2.33

'a' 09/91-RfD 00 (general)

S/N 0.60 1

- 0,07 15 15 09/91 RfD 10 (general)

- 56 % TW. 2.031HIS P

  • 15. 73 -

16 38 09/91 RfD ID-(generat)-

5/N 18.88 HIS P

+17.10 16 111 09/91 #FO. DD (generat).

0.84 5 3,08

>17 70 09/91 RFO. ID (crierat)

. S/N

. 11.49 HIS P

+

7.72

$/N

+

'.18 9 09/91 Rr0 00 t.

.eral)

S/N -

- 0.25 1

. 09/91 St.

DD (Vaneral)

S/N 0.05 1 c18--_10 09/91 is ID (general)

S/;8 0.20 MIS S 0.04

+

18 83 09/91 15

.0 (general).

S/N

-0.24 HIS S 2.05

19. 31 09/91 RF0 -ID (general)

S/N 1.38 HTS-P 14.90

-1

+

19 32 09/91 RF0 -th (general)

S/N 1.78 HIS P

  • 16.81 20

.6 09/91 15 tu (generat) s/N 0.24 Hlb $1

+ 0.24 1

mvNw -

-Ae

-m n

e r

x w-un-

~

f V

~.

~.

~ - -,

.~~~n.

. ~ ~

.n.

s

-A-

  • * * * *
  • DUK( iiUSAb(TM) (VE R. 3.0)* * * * *
  • Moncay Novader 9i 1992-08:53 AM ****** sAscoCK & WILC0x CO. ****** Page--

~ 3-Plan'* McGUIRE UNIT 1 Steam 9cnerator B

Dulesesi 09/91 RfD _09/91 SLV 09/9; 15 09/91 51 4

00fRT' AIT ACHMf Ni l..!NDiCATIWe Of IMPERf(Cilok$

......,.........,..............~,.....

ROW COL Ou1 AGE jkDiCATION VALUt VOL!$.tOCAilON I NCHI;$

C9/91 li ID (general)

S/N 0.16 Hlo S

  • 0.20
70. 11 09/91 RFO. ID (geveral)

S/N 14.38 HIS-P

+16.02 20 14 09/91 Rio 00 (generbt)

$/N 0.89 2

+ 0.02 09/91 $1

-OC (general)

  • /N 0,28 2-20 32 09/91 RfC ID (general)

S/W-4.38 HIS P

+ 6.35

+

20- 35 09/91 RfC 10 (general)

S/N 0.82 bis P

+18.85 09/91 15 ID (general)- - S/W 0.24 H15-S

- 2.15 20 39 09/91 #fD ID (general)

$/N 1.47 HI$ k

  • 15.04 09/91 15 ID (general)

S/N 0.20 HIS S

+ 0.08 20 102 09/91 TS. ID (general)

S/N 0.16 HIS-S 0.55 21 19 09/91 RF0 10 (general)

S/N 4.64 HIS P

+16.94 09/91 Rf0 00 (general) 17.% TW 0.36 10

+ 27. 75 21 25 09/91 RF0 10 (general)

S/N 2.61 HTS-P

+11.25 2'

27 09/91 SLV ID (general)

- S/h 6.58 HIS-P

+14.52

)i 31 09/91 RfC.10 (general)

' S/N 2."

HIS-P

+15.02 J1 38 09/91 RF0 CD (general) 16 % TW P 49 C15 5

+25.28 09/91 S1 DD (general)

S/N

. 65 Cis S

+24.62

?! 42 09/91 RfC ID (general)

S/N 1.78 HIS P

+17.79 s

09/91 t/ lb (general)

S/N 0.28 HTS-S 3.08 09/91 is ID (general)

S/N 0.24 HIS-S 3.1?

1 D9/91 is ID (general)

S/6 0.20 HTS S 3.12 09/91 IS 10 (general)

  • d 0.12 HIS S 3.12 09/91 15 ID (gee,eral)

Sid 0.16 HIS-S

- 3.16 09/91 is ID (general) 4/N 0.12 HTS S

- 3.20 21-56 09/91 Y$

ID (general)

S/N 0.20 H15-S

.0.98 0

09/91 is 10 (general)

S/N 0.12 His-S 0 98 09/91 IS 10 (general)

S/N 0.12 His s

- 0.98 22 10 09/91 RFO (D (general' S/N 1.66 HIS P

+ 9.48 22.12 09/91 15 1 0 ( 94 wer.1) s'r

-- 0.12 HIS*S

+ 0.08 22 la 09/91 Rfo ID (generas) 83 % 1J 1G.31 HIS P

+ 5 73 09/91 RFO' ID (genera-)

S/N 1.62 HIS P

+16.04 22 33 09/91 RF0.10 (generat )

r/N 4.32 HIS-P

+11.07 22 52 09/91 RF0 ID (gg.scral)

SsN 2.68 HIS P

+16.23 22 63 09/91 TS 10-(general.'

S/h 0.12 HTS-S 22 67 09/91 RFO la (general)

$/N 2.73 HTS P

+ 12. 79 22 72 99/91 IS ID (general).

S/N 0.24 HIS-S 0.59 09/91 15 lb (generat)

$/N 0.24 H15 5-0.63 09/9! i$ 10 (general) - 5/n 0.20 HIS S 0.67

.09/91 TS 10 (general)

. S/N 0.20 HIS-S

- 0.67 22 93 09/91 RF0 :10 (general) ' S/N 0.12 HIS-S-

- 0.71 09/91 15-10 (general)

$/N 11.59 HIS-P

+13.D3 09/91 15' 10 (general)

S/N 0.20 MIS S. =

- 2.93 S/N 1.77 HIS P

  • 14.98 23-20 09/91 RfD ID (general). S/N -

2.35 HIS P

+10.17 09/91 RfD 10 (generat) '

23 --23 09/91 AfD ID (general).

S/4 1.77 HIS-P

+ 4. 71 09/91 RF0 10 (general) h / N.-

13.32 HIS-P

+ 9.19

C 09/91 Rf0 ID (general)

S/N 3.11 HIS P

+10.35 09/91 RF0.10 (generat)

. S/h.

5.06 HIS P

  • 11.53 09/91 RF0 ID (general)

S/N 13,87 HIS-P

+12,59 D9/91 #f0 10 (general)

S/N 11.65 HIS P

+14.80 09/91 Rfo 10 (general)

S/N 4.47 his P

+15.98 09/91 RF0 10 (general).

S/h 7;32 HIS-P

+ 17.10 09/91 15-ID (general)

S/N -

0.12 HTS S_

+ 0.04-2% 26 09/91 RF0 10 (general)

S/N 2.47 HIS P

+13,75-L 23 37 09/91 RF0. ID (general)

S/N 1.50 nis-P

+12.03 09/91 15 - 10 (general)

S/N 0.16 HIS-S

. 23T 4109/91 RF0 ~ 10 (general)

S/N 2.68 HIS P

+15.24 21 =45 09/91 Rfo 1D (general)-

S/N 1.73 HIS-P

+10.58

23. 61 09/91 iS ID (general).

S/N 0.24 His S

+ 0.16 23 68 09/91 TS 10 (genera's S/N 0.32 HIS-G

.+ 0.08 09/91 15 ID (general S/N 0.16 HTS S 2.42-

~

L23 82 09/91 is ' 10 (general)'

S/W 0.20 HIS-S 0.79 07/91 is 10 (general)

S/N 0.32 KfS-S 0.79 09/91 is ID (general)

S/N 0.lo his S 0.79 L

09/91 TS _ID (general)

S/N 0.12 His S 1 0.83

- 24.18 09/91 IS 10 (eeneral3 S/N 0.24 His S

+ 0.24 24 23 09/91 Rfo. 00 (generat)

. 71 % 1 W

-0.84 1

+-0.08 j;

l l

1 I

-1l

~

~s-a

+,-

r

- + - -

-,.~. -

.m..

e-e.

+

-****I* Duke-h103Ak(IM) (vt R. 3.0)**** ** Monday Novemt;er ; 9[1992

' 08:53 AM i**** BAscocr & Witt"4 Co. """ Page --

Al

' Pl ant s Mc GUl Rt UN t i 1 Steam Generatort B

~ (>>t a995 ! '

09/91 RfD 09/91 civ- -09/91 15 09/91 St QUff.YtAITACHHini3LINDICAllONSOF...........

!MPERffCIIDNS 90W Col DUI AG(

INDICA!!ON-VM *K VOL T S L OC AT I ON INCHES l

a it_

14 ' 25 09/91 Rf0 -10 (general)

S/N 3.31-HIS P

+17. 75 J9/91 IS 10 (generat)

%/N 0.32 HIS S

- 3.13 09/91 SI 10 (general)

S/N 2,36 HIS-S.

3.29

'24.28 09/91 RFO 10 (general) 58 % TW,

8.59 HIS-P

+ 9.32 24 39 09/91 SLV ID (general)

S/W 3.62 "is-P

+ 9.66 24 43 09/91 TS ID (general)

S/W 0.04 H1S S 0.12 24 46 09/91 IS ID (general)

$/N 0.16 HTS S

  • 0.12 P7/91 IS ID (general)

$/4 0.16 HIS S=

+ 0.12

- t 09/91 is ID (general)

S/N.

0.12 HIS-S

+ 0.08

~

24 50 09/91 RIO ' 10 (genr ret )

$/N 1.56 HIS-P

+15.24 24 88 09/91 RfD 00 (generati

  • fe 0.37 1

+ 0.13 09 91 St.

DD (general)

S/4 a 19 1

/

25 38 l'9/91 is ID (general)

S/W 0.se niS-S

  • 0.12 2$ 92 09/91 Rf D - ID (general)

S/N 4.01 HIS P

+ 13. T2

-26 8 09/91 RfC OD WEAR 17 % TW 0.89 Av82 26 21 09/91 IS ID (general)

S/W 0.20 MfS S

+ 0.20 26 49 09d91 1S ID (generat)-

5/N 0.20 HTS-S.

+ 0.16 26-53 09/91 TS-ID (g(neral)

S/N 0.24 HIS S

+ 0.16 26 62 09/91 is 10 (general)

S/N 0.20 HIS S

- 1.92 26 80 D9/91 Y$

ID (generat)

S/N 0.24 HIS-S

- 2.92 26 87 09/91 RfC ID (gercrat )

S/W i.72 HIS P

+12.18 27 8 09/91 RF0 00 (genero'. )

21 % IW 0.56 6

+34.78 27 16 09/91 RIO ID (geraret )

S/N 16.21 HIS P

+11.15 27 2/ 09/91'SLV ID (general)

S/N 6.20 HTS-P

+ 6.03

-27 43 09/91 15-ID (general)

S/N 0.24 HTS S 1.27 27 14 09/91 15 IS (general)

$/4 0.16 HIS S

- 0.04 28 1$ 09/91 is - ID (general)

S/N 0.20 HIS*S 2.21

' 28 24 09/93 Rf0 00 (general) 5/N 0.36 1

+ 0,05 28 68 09/91 It 10 (gancrat)

S/N 0.16 HfS+S 0.08 28 71 09/91 kf0 lb (general)

$/N 3.48 HIS P

+17.51 09/91 15 10 (general)

.S / N 0.35 HIS S

+ 0.16 09/91 15

D (general)-

S/W 0.35 HIS S 2.97

.09/91 is-10 (general)

S/N 0.i4 HIS S 3.01 09/91 75 ID (general)

S/N 0.?5 HIS S 3,01 09/91 is ID (general) 5/N 0.24 HTS *S

- 3.05 2h 65 09/91 RfD ID (gerecal) 88 % TW '

7.56 HTS *P

+11,45 04/91 RfD ID (general)

S/N-2.52 HIS P

+14.47 09/91 RfD - ID (generti) 85 % TW 8.21 HIS-P

- +18.22 09/91 TS 10 (general)-

S/N 0.35 HIS S

- 2.82

- 09/91 TS 1D (general)

S/N 0,24 His-S

- 2,90 09/91 TS ID (general)

S/W

'O.20 HIS-$

--2.94 09/91 is-29 57 09/91 is ~ lo (general)

$/N 0.24 NfS S

- 2.94 t

10 (generat)

S/N 0.20 HIS S

+ 0.08 29 63 09/91 IS-10 (generat)-

5/N 0.24 HIS S 09/91 is 10 (generall S/N 0.16 HIS+$

- 0,04

. 09/91 IS ID (general)

S/N 0.16 HIS-S

- 0.04 29 74 09/91 IS - 10 (general)

S/N 0.24 HIS S 1 2.39 09/91 iS ID (general)

S/N O.16 HIS S

- 2.50-30 35 07/91 RfD 00 WEAR 22 % TW 0.77 AV82

!~

(10 57 09/91 is ID (generat)

S/N 0.16 HTS-S 30.$5 09/91 RfC 10.(Deneral)

S/N

-6.01 HfS P

+ 1.37 30--61 D9/91 is 10 (generet)

S/N 0.16 MTS-S 0.12 31 13 09/91 ts' ID (general)

S/N 0.16 HIS S

  • 0.16.

~

31 15 09/91 JS ID (general)

S/N 0.20 HIS S

- + 0.16-31 30 09/91 is to '(generat) 5/N 0.16 HTS-S

+ 0.16 31-54 V9/91 SLV' iD (general)

S/N

-3./3 HIS-P-

+11.21-21 - 56 09/91 Rf 0 - 10 (general) - S/N 2.40 HIS P 14.09 31 '59 09/91 RF0 -10 (general)

/N 4.34 HIS-P

+11.13 314 69 09/91 15 10 (general)

$/N 0,20 HIS-S

+ 0.16 31 79 09/91.i5 10 (general)

S/W.

0.24 HTS-8 2.09 32 09/91 950 00 (general)

S/N.

0.43 1

- + 0,05

- 09/91 61 00.(general)

S/N-0.24 1.

.132 53 09/91 TS-IL (general)

S/N 0.20 Hists

- e 0,D4 32 56 09/91 IS ID (general)

S/W 0.28 HIS S 3.32 12 63f4/91 iS 10 (general)

S/N 0.32 HIG S 0.20

+

09/91 TS 10 (generat)

$/N 0.20 Mf S S -

0.16

+

09/91 TS ID (general)

S/N 0,16 MfS-S-

+ 0,12 4

L r'% m@

v i

-'h T#

U $9-w 9 WW 4

  • rs

.w-W e

e e n el-e

- ' - -+ - - -

-e=

u-4

x a

n., -

~+..~. ~

--c-

-n~_.

..~.,,.

.._... ~ -.

~.. *.

']

L+*'*i 6U4 TUBAN(f M) (vl R. 3.0)****** Morcy hovenber

.9, 179?

08:54 AM "*"* BA8 COCK & Wil cox Co, **""- Page -

?5

~

plant McGUIRE UNIT 1 Steam Generator B coutages:

??/V1 RF0 ~ D9/91 Stv 09/91 TS 09/91 St 44RY1 ATT ACHMENT 1L,.INDICAllDNS Of IHPCRFEC110NS.

RDW COL DUTAGE INDICAil0N VALUE VOLTS LOCAlloN - INCHE$

...n

- 09/91 15-ID (general)

S/N 0.16 HIS S

+ 0.08 33 '19 09/91 RF0 10 (generat)

$/N -

5.02 HIS-P

+ 0.93 09/91 RF0 ID (general).

S/W 3.09 HTS P

+11.44

- 09/91.RF0 ID (general)

S/N -

1.61 HIS P y12.26 09/91 RF0 ID.(general)

S/W 2.20 HIS P

+13.21 09/91 RF0 ID (general)

$/N 3.12 HIS P

+17.13 09/91 RF0 10 (general) 44 % 1W 4.82 His P

  • 15.30 1

09/91 RF0 10 (general)

S/N 3.66 HTS-P

+16.24 t

09/91 RF0 ID (general) 72 % TW

.4.63 His P

+18.20 09/91 1$

ID (general)

S/N 0.20 HIS+$

09/91 1S ID (general)

S/N 0.24 HIS S 2.9) 09/91 TS ID (general)

$/N 0.16 HIS-S 2.91 09/91 IS - ID (general)

S/W 0.12 HIS S 2.91 09/01 15 ID (genera'.)

S/N O.12 HIS S

- 2.91 09/91 IS 10 (general)

S/W 0.04 HIS-S 2,95 09/91 15 ID (general)

S/N 0.16 HIS S

- 2.95

33. $1 09/91 RF0 OD (general)

S/N 0.64 6

.+17.68 09/91 Si 00 (general)

S/N 1,32 6

+18.20-31 ~ t6 09/91 RFC ID (general:

S/N 5.98 HIS P

+ 6.08 33 75 09/91 15 ID (general)

S/N 0.12 C15 5

+ 0.91 33 100 09/91 RF0 00 WEAR 18 % TW 0.95 Av82 33 102 D9/91 RF0 00 (ganeral) 1 % TW 1.22 2

+31.48 34 15 09/91 RF0 00 (general)

S/N 0.66 1

+ 0.07 34 24 09/91 RFC ID (general)

S/W 5.29 hiS P

+ 1.36 e

1,.30 09/91 RF0 00 WEAR 16 % TW 0.80 AVB2 34 55 09/91 RF0 ID (general)

S/W 2.27 HTS P

+13.26 09/91 15 ID (general)

S/N.

0.12 HIS S 34 57 09/91 RF0 10 (general)

S/N

5. 79 HI S P

+14.21

- 14 t,4 09/91 RF0 ID (general)

S/N

.1.87 HIS P

+11.D6 34 ' 77 09/91 RFC DD (general)

S/N-0.27 2

+ 0.03--

34 84 09/91 RF0 OD (general)

S/N 0.68 AVG 1

+20.17 35 39 09/91 Rf C. ID tgencr !)

S/N 2.40 HTS P

+ 13. 79 -

u 55 41 09/91 sty 10 (general)

S/N 2.82 HIS P

+12.03 35 47 09/91 is ID (general)

S/N 0.16 HIS S

+ 0.12 35 48 09/91 RF0 00 WEAR 17 % TW 3.53 Aval 35 50 09/91 Rio OD (general)

S/W 0.42 1

+ 0.03 35 53 09/91 RF0 00 WEAR.

24 % TW 1.38 Av82 35 54 09/91 15 ID (generat)

S/h 0.24 HTb 5

+ 0.12 35 75 09/91 RF0 CO WEAR 18 % TW 0.57 Av83 35 78 09/91 RIO 00 WE AR 26 % TW 1.65'AV83 35 99 09/91 RF0 ID (general) 80 % TW 16.92 HIS P

+ 5.37 36 39 09/91 RF0 00 WE AR 15 % TW 0.72 AVB1 36 65 09/910F0 DD WE AR 15 % TW 0.74 AVB3 109/91 RIO 00 WEAR 19 % TW -

0.99 AVB4 36 69 09/91 RF0 DD WEAR 21 % TW 1.17. AVB3 -

36 72 09/91 RFC DD WEAR 11 % Tu 0.31 Av82-37 ~ 49 L9/91 TS 10 (gen (ral)

S/h 0.16 HTS S

  • 0.12 33 30 09/91 RF0 10 (generals S/N 4.40. HTS-P

+ 6.27 38 44 09/91 15 10 (generat)

S/N 0,28 HTS-s-

+ 0.12 38 54 09/91 RF0 OD WEAR 20 % TW 0.69 Avat 09/91 RFU OD WE AR 15 % TW 0.46 AVB3 38 ~ 58 09/91 RF0 00 WEAR 37 % TW 3.'21 AVB3 09/91 RF0 DD WEAR-13 % TW 0.62 Aval 38 59 09/91 WF0 00 WEAR 21 1 TW 1.14 AVB2-09/91 Rr? 00 WEAR-14 % TW 0.69 Aval 09/91 RF0 00 WEAR 15 % TW 0.'6 Av83 98 D9/91 15. 10 (gencfal)

-S/N 0.28 His e

  • 2.99 09/91 IS ID (general) - S/N 0.28 HIS S 2.99 09/91 15 ID (general)

S/N 0.16 HIS-S 3.10 09/91115 ID'(general)

$/N 0.16 HIS-S

- 3.10

.09/91 is 10 (general)-

S/N 0,16 HIS S 3.10

?9 09/91 iS ID (general)

S/N 0.24 His.S.

  • 0.28 -

21 09/01 T5 ID (general)' -t/N 0.16 HIS S

+ 0.16 76 09/91 RF0 00 WEAR-501 TW 4.17 AVB2

-09/91 RFO' 00 WEAR 21 1 TW 0.73 AVB3 09/91 RF0 00 WEAR 11 % IW -

0,31 Av84 39 BG 09/91_RF0 -00 WEAR

'25 % TW'

'1.50 AVB2 i

, + l-y N

-,~

n---n

,- ~ >

~

~

4,

s;

+

  • *** *
  • DULE 1100AN(TM) (VER, 3.0)* + + +++ ponday Novenber 9, 1992~

08:55 AM * * * * *

  • BARCoct & WitEOx Co. * * * * *
  • Page '

'6 Plants McGulpf UNll' 1 Steam Generator 3 $

Ovtagest- -09/91 RF0 09/91 Stv 09/91 15 09/91 $1

,00ERf..:, Alf ACHMENI Q,1NDlCAT10h5 0F JMPERF(Cil0NS RDW (Dt Dui/CE-

- INDICA 110N '

-VALUE votis LDCAllDN INCHES

......+..........

09/91 RF0 DD WEAR 32 % TW

?.33 AVBt 40 31 09/91 is ID (General)

S/N 0.?8 HYS S

+ 0.24

- 40 34 09/91 RfD OD (gencial) 61 % TW 0.46 2

+ 0.15 40 38 09/91 RfC 00 WEAR 11 % TW 0.85 AV83

-40 62 09/91 RFC-DD VEAR 14 % TW-0.44 AVB1

~

40 10 09/91 RfC 00 WE AR 21 % TW 1.13 Av83 41 22 09/91 IS ID (gercrat)

S/W 0,24 HIS S

+ 0.20 41 25 09/91 f5 10 (generat)

S/N 0.24 HIS S

+ 0.20 41 27 09/91 15 10 (general)

S/W 0.20 His S

+.0.20 41 44 09/91 Rio 00 WE AR

.15 % TW 0.75 AVB4 09/91 RfD 00 WEAR 11%TW 0.53 AVB3 09/91 RF0 00 WEAR 22 % IW 1.28 AVB2 41 47 09/91 15 ID (general)-

5/N 0.28 PTS S

- 3.06 09/91 is 10 (generat)

S/W 0.2G His S

- 3.13 09/91 TS ID (generat)

S/N 0.20 HTS S

- 3.17 3.17

-09/91.15 ip (general) s/w 0.20 *TS S 3.17 09/+1 15 ID (generat)

S/N 0.16 HIS S 09/91 TS 10 (general) - 5/N 0.12 HTS-S

- 3.21 09/91 15 10 (general)

S/h 0.16 HIS S 3.21 il 48 09/91 Rf0 00 WEAR 20 %-1W 1.06 AVB2 41 57 09/91 RfD 00 WEAR 13 % TW 0.60 AVB1 41 58 09/91 RF0 0D WEAR 25 % TW 1.55 AVH1 41 6e 09/91 15. ID (general)

S/N 0.20 r,fS.S

+ 0.20 09/91 TS 10 (general)

S/N 0.16 HIS S

  • 0.20 09/91 15 ID (general)

S/N-0.16 HTS S

+ 0.16 41 64 09/91 RfD 00 WEAR

. 30 % TW 2.10 AVB1 09/91 RF0 00 WE AR 26 % TW 1.64 AVB2 09/91 RF0 00 WfAR 27 % TV 1.69 AVB3 41 65 09/01 RfC 00 WEAR

-13 % IW 0.65 AV91 09/91 RF0 00 WEAR 34 % IW 2.62 AVB2 09/91 RF0 00 WEAR 21 % TW 1.14 AVB3 66 09/91 RF0' 00 WEAR 19 % TW

-0.97~AV81

~41 41 68 09/91 RF0 00 WEAR 12 % TW' O.59 Aval 09/91 RfD 00 WEAR

. 7 % TW 0.21 AVB3

~ 41 70 09/91 RFO 00 WEAR 17 % TW 0.B6 AVB1

-*1 71 09/91 RF0 00 WEAR 14 % TW 0.42 AVB1

.i 12 % TW 0.58 AVB1 1

41 72 09/91 RF0 00 WE AR

. $/N 0.20 HIS-S

+ 0.16 j

41 B5 09/91 15-ID (general) 41 87 09/91 IS - ID (general)

S/N-0.16 His S

- 1.05 09/91 1$

'!D (generat)

S/N 0.16 HIS*S

  • 1.05
l.

09/91 TS-to (general)

S/N 0.16 HIS S

--1.05 41 91 09/G1 15-ID (general)

_S/W 0.28 HIS S 3.05 42 35 09/01 15 10-(general)

S/N G.?S HIS S

+ 0.16 09/ 1 15 10 (general)

$/N 0.16 HIS S

+ 0.12' (J

09 11 TG 10.(generat)

S/N 0.16 HIS S -- -+ 0.12.

09/91 15 ID (general).

S/N.

0.12 HIS S

+ 0.08

-42.,59 09/91 Rfo 00 WEAR-37 % fv 1.90 Ava) 09/91 RF0 DD WEAR 16 % TW 0.51 AVB2-09/91 RF0 00 WEAR 17 % tv 0.57 AVB3 42,~64 09/91 RF0 '00 WEAR-27 % TW 1.71 Av81 42 75 09/91 RF0 00 WE AR 19 7 TW 0.98 AV02 09/91-RF0 OD' WEAR

^ 45 % TW ' - 5.15 eid3 :

43 22 09/91 RFO OD WEAR

-20 %'fW 1.08 Aval 09/91 RfD OD WEAR ~

16 % TW 0.80 AVB2 43 l24 09/91 RFC OD (general).

14 % tw 0.79 6

+1?,55

~

43 34 09/91 is-10 (general).

S/N-0.20 HIS $-

+ 0.20

'j

43 35 09/91 TC

.!D (general)

S/N 0.28 HIS S

~ + 0.74

09/G1 TS 10 (general)

S/N 0.20 His S-4 0.16 43 36 09/91 IS. 13 (general)

S/N.

0.16 HIG S

+ 0.16 i (general)

. S/N 2.7d MIL P.

. +16.95 43 -89 09/91-RF0

_'44-28 09/91 TS ID.(generat, S/N 0.20-His S._

.. 0.161

+ 0.20 44'133 09/91 IS ID.-(gener al )

S/N-0.16 HTS S 09/91.TS ID-(general)

' $/N 0.16 MfS-S

+ 0,16 44, 60 09/01 is it (genernt) ~

5/N-

~ 0.32 H75 + 0.28 S/N 09/91 TS 10.(general) 0.20 HTS S

. + 0.20-09/91 iS 10 (general)

S/N 0 16 HIS S

+ 0.16 a

i 09/91 15 -.10 (generat)

S/N 0.12 MTS-S-

+ 0,.12

l o--

n

4 Ji te
            • 'Duxt.-10 BAN (IM), (VCR. 3.0)* ** * *
  • Monday Noventier ;. 9.'1992 05:55 AM ****** BABCOCK & WILCOX Co. ****** Page 7-

~

Plant's McGUIRL UNIT 1 09/91 15

.D9/91 SI Steam Generator 6 Dutagess.-

09/91 RfD 09/91 St'v 00ERV: AllACHMENT CL lNDICAllOkt Of IMP [RIECilDN!

RDW COL DUI AGE INDICAf!DN VALUE VOLTS LOCAllDN INCHES 44 62 09/91 RfD OD WE 'R 18 % TW 0.95 AV81-

- 44 63 09/91 RfD OD WEAR 15 % TW 0.04 AV81 44 65 09/91 IS 10 (general)

S/N 0.20 HTF S

+ 0.24

_ 09/91 IS ID (general);

$/N 0,20 HIS S

+ 0.24

- 09/91 TS ID (general)

$/N 0.20 HIS S

  • 0.20 09/91 is ID (general)

S/W 0.16 H15-S

+ 0.20 09/91 15-ID (general)

S/N 0.16 HIS-S

+ 0.20 09/91 IS 10 (general)

$/N 0.12 HIS-S

+ 0.16 09/91 is ID (gereral)

S/N 0.G4 His-S

+ 0.08 44 82 09/91 RfD-ID (general) 75 % TW 23.16 HIS+P

+ 3.54

~ 44 86 09/91 RfD 00 (gen (+al)

S/N 0.49 1-

+ 0.16 45.30 D9/91 Rf 0 - 00 (general)

S/N-0.31 3 45 61 09/91 IS 10 (general)

S/N-0.16 HIS S

+ 0.08 45 74 09/91 RTO 00 (general)

S/N 0.27 3.

  • 0.19 45 83 09/91 IS ID (teneral)

S/N 0.20 HIS-S

- 1.22

. 46 33 09/91 RF0 00 (general)

S/N 0.69 ;

0.05 09/91 51 DD (general)

$/N 0.33 1 46 3a 09/91 R!O OD (general) 5/N 0.51 3

  • 0.03 46 -36 09/91 PIO 00 (general)-

73 % TW 1.56 1

+ 0.05 09/91 s1 00 (general)

$/N 0.55 1 46 77 09/91 dFD 00 (general)

S/N 0.34 2

+ 0.19 41 84 09/91 is ID (general)

$/N 0,32 His S

- 2.02 09/91 IS 10 (general)

E/N 0.24 HIS S

- 2.06 09/91 is 10 (general)'

S/N-0.28 HIS-S

- 2.06

- 09/91 15 ID (general)

S/N -

0.24 HIS S

- 2.06 07/91 15 10 (general)

S/N 0.20 His s

- 2.10 09/91 TS 10 (generet)

$/N 0.24 HIS S

- 2.10

~

09/91 is 10 (general)

S/N 0.20 HTS J 2.14 49' 40 09/91 Rfo 00 WEAR 15 % TW 1.57 17 49 52 09/91 RFO- 00 WE AR 24 % TW 2.75.16 09/91 RF0 00 VEAR 11 % TW 1.05 17 09/9) RF0 OD' WEAR 21 % TV 2.30 19 49 57 09/91 DFO CD WE AR 14 % TW 1.82 17 09/91 RfC 00 WEAR 13 % TW 1.68 19

-49 78 09/V1 is 10 (general)

S/h 0.17 HIS-S 1.74 259 TOTAL TUGES TOUND

=

TOTAL INDICATIONS FOUND 2

437 l.

l..

l l-6 7

u t

1 i

.i.. -

~.. -... -. - -

--.---,.-_.-,_--n--__.

ji

\\=

'***(Dutt IUBAN(TM) (VER,-3.0)****** Nonday November 9, 1992 I 08:56'AM ****** sAsCoct & WitC0x Co ** * * *

  • Page ~

El

~

Plant: McGulRt UNii 1

.Stenm Gervrator C Outages; 09/91 000 09/91 StV 09/91 15-09/91 Si DUTRY: A11 ACHMLNI 3 INDICAil0NS Of' lMPERf f CilDNS

+

VALUE VOtiS l0 CATION INCHES POW COL DVI AGE '....INDICAllDN 2 67 09/9100H 00 (generat) 4 % TW-0.61 =

+ 3. 73 09/91 58 00 (general)

S/N 1.04 4

+ 4.19

?

'?.94 09,91 is ID (general)

J/N 0.16 ETS S

  • 0.12 09/91 is 10 (generat)

S,%

0.16 NIS S

+ 0.12

.l 09/91-15 ID (general)

S/N 0.1

'S

+ 0.12 2 95 09/91 l$

10 (general) 1/N 0.32.n*

+ 0.16 09/91 15 10 (general)

S/N 0.?O HTS S

+ 0.12 09/91 TS 1D (general)

S/N 9.16 HTS S

+ 0.12 09/91 15 3D (general)

S/N-0.16 HTS S

+ 0.12 2 105 09/91 15 ID (generet)

S/N

'O.12 HTS-S.

+ 0.08

'2 108 09/91 15 ID (general)-

S/N 0.12 HIS S

+ 0.12 2 109 09/91 TS ID (general)

S/N 0.16 His S

+ 0.12 09/91 is 10 (general' S/N-0.16 HIS S

+ 0.12 2 Ill 09/91 TS 10 (general), S/N 0.12 HTS *S

+ 0.12 09/91 iS 10 (general) - 5/N 0.12 HIS S

+ 0.12 3 64 09/91 IS.

10 (general).

S/W 0.20 HTS S

+ 0.04

'3 102 09/91 is 10 (general)

S/N 0.20 His S

+ 0,04 3.106 09/91 TS ID (general)

S/N 0.20 HIS S

+ 0.04 09/91 15 10 (general)

S/N 0.20 His S

+ 0.04 4 64 09/91 IS 10 (general) - S/N 0.10 HTS S 2.33 09/01 is 10 (general)^

S/N 0,13 MTS-S 2.33 09/91 IS ID (general)

S/N 0,10 HIS S

- ?.33 09/91 is 10 (general)

S/N 0.10 HIS S

- 2.36 OV/91 TS ID (geocrat)

S/N 0.07 HIS S

- 2.36 4 71 09/91 15 LD (general)

S/N 0.13 HIS*S

+ 0,03 1

09/91 IS-ID (general)

$/N 0.03 HIS S 0.07 4 77 09/91 15 10 (general)

S/N 0.10 HIS-S

+ 0.03 i

4 81 09/91 15' 10 (general)

S/N' O.16 HIS-S 0.03 4 93 09/91 15-10 (su m#ol)

S/W 0.13 HTS S

+ 0.07' 4

4 101 09/91 IS 10 (weneral)

S/N 0.13 HIS-S

  • 0.10 09/91 TS (D (general)

S/N b.10 MTS S

+ 0.07

-4 105 09/91 is 10 (gener6l)

S/N 0.20 HIS S

+ 0.10 09/91 15-L1 (general)

S/N '

O.27 HIS-S

+ 0.13 4

09/91 IS 1(, fqenerat)

S/N 10.13 HIS S

+ 0.03 09/91 is 10 (general)

S/N 0.10 HIS S

5. 63 09/91 B00 10 (general)

S/N 5.91 H?S P

  • 18.34 i.

09/91 808 10 (general) 40 % IW 9.75 HIS S 09/91.TS 10 (general)

S/N 0.31 HIS S-

+ 0.31 l-09/91 TS 10 (general)

S/N 0.23 HIS-S

.* 0;19 09/91 15 ID (general)

$/N 0.15 HIS S

+ 0.15 68 09/91 15 10 (general)

$/N 0.15 HTS S-

- 2,77 i

09/91 15 ID (general)

S/N 0.15 HIS-S.

2.81 09/91-15 10 (general)

S/N _

0.15 HIS S

- 2.81 i

09/91 IS ID (genci al)

S/N 0.11 HIS-S

--2.81 l.

75 09/91 15 10 (general).

S/N

- 0 19 HIS-S -

+ 0.19 i-09/91 TS' ID (general)

S/N 0.11 HTS-S

+ 0.15 5 78 09/91 15 10 (general)

S/N 0.19 His S

+ 0.23' i;

09/91 15 ID (general). S/N 0.17. HTS-S

+ 0.23 09/91 15 10 (general)

S/N 0.15 His-S

+ 0.08 5 80 09/91 15 10 (general)

S/N 0.19 HIS S

+ 0.08 5 81 09/91 000 OD (general)

S/N 0.76 5

+16.36 1

5 '95 09/91 15.lD.(general)

S/N 0.16 HIS S -

+ 0.07 4

5 101 09/91 is 10 (general)

S/N 0.16 NfS S

- 0.03 09/91.15= 10 (general)

S/N Oi13 HIS-S

- 0.07 5 101 09/91 TS ID (general)

S/N 0.16 HTS S 6 95 D9/91 IS '10 (generet)

S/N 0.15 His S r 0.04

' 09/91 15

-10 (gen

.()

.S/N 0.11 His-$

+ 0.04 6 98. 09/91 is~ (D (general)

S/N 0.04 HIS-S _

0.15 7 106 09/91 TS (D (general)

S/k 0.11 HfS S

+ 0.04 71:13 09/91.1S ID (general)

S/N 0.53 HTS S

+ 0.49 09/91 15 ID (generat)

S/N 0.15 HTS S

+ 0.08

0 72 09/91 is 10 (general)

S/N 0.10 HIS S 1

09/91 is

.10 (general)

S/N 0.13 HIS-S 8 98 09/91 'S 10 (9eneral)

S/N 0.13 HIS-S

. + 0.03 09/91 TS ID'(general)

S/N 0.10 HIS-S 8 539 09/91 15 10 (general)

S/N

- 0.10 HIS S

+ 0.06

._9 _ 71. 09/91 T S 10 (general)

S/k 0.16-HIS S d

r

_m_--_

ms

.~. - _ _ -.. -.

m.--

~

~ ~

.i bl#

[3x -

I.e

~

            • DUEE TUBAN(TM) t yt R [ 3.0)* * * *' ' Monday Novenber -

9, 1992 08i57 AM. ** * * *

  • B ARC 0CK & WI( COX CO.' * ** * *
  • Page :

- 2'-

Plants McGUIRE UNIT 1-Steam Generator C

.0ytages:

09/91 808 09/91 SLV 09/91 is 09/91 $1 IMPERffCTIONS outtYi ATTACHMCNY $..INDICAf tDNS Of ROW COL OUTAGE INDICAil0N VALUC VOLis LOCA110N ! INCHES 4..

10- 22 09/91 808' OD (general)

.S/N 0.58 to

+29.05 10 55 09/91 TS ID (general)

$/N 0.16 HTS S

<11 37 09/91 800. ID (general)

S/N

. 0.28 HTS S

+ 0.08 10 86 09/91 TS ID (general)

S/N 1.78 HIS P

+15.08 1 51 09/91 is ID (general)

S/W 0.20 His S

+ 0.08

.11 80 09/91 15 ID (generrst)

S/N O 16 MTS S

+ 0.04 11.82 09/91 Boa 00 (general)

S/N.

0.63 1

+ 0.13 09/91 SI. UD (general)

S/N 1,46 1 0.04

-11 98 09/91 IS 10 (general)

S/N 0.16 NTS-S-

+ 0.04 11'113 09/91 iS ID (generat)

S/N 0.12 HIS S 2.8/.

_-12. 31 09/91 BOS 00 (general)

-$/N 0,12 4 12 58 09/91 TS ID (general)

S/N 0.63 CTS-S

- 0.04 09/91 15 ID (general)

S/W 0.59 Cis-S

- 0.04 09/91 is ID (general)

S/N 0.28 Cis-S

- 0.04

- 09/91 is ID-(general)

$/N-0.20 CTS-S

- 0.04 09/91 15 ID (generat)

S/N 0.32 CTS S

- 0.08 09/91 iS ID (general)

S/N 0.20 'is S

- 0.35 09/91 iS ID (general)

S/N 0.2( CIS+S

- 0.35 09/91 TS ID (general)

S/N 0.47 CTS S 1.10 09/91 IS to (generat)

S/N 0.0* CTS-S

- 1.14

. 09/91 is iD (generali S/N 0.12 Cis-S

- 1.26 09/91 15 ID (general)

S/N 0.04 Cis S 1.30 09/91 1S 10 (general)

S/N 0.32 CTS S

- 1 34 09/91 TS ID (general)

S/W 0.24 CTS S 1.38

_09/91 15 ID (general)

S/W 0.12 CTS-S 1.42 1

. 09/91 15 10 (general)

S/N 0.04 CIS-S 1.58-12 68 09/91 TS

!D (general)

S/N 0.16 uts S

+ 0.04

- 09/91 15 10 (generat)

S/N 0.20 HIS S

+ 0.04 09/91 15 10 (general)

$/N 0.16 HIS S

+ 0.04 09/91 IS 10 (general)

S/W 0.12 MTS-S 12 78 09/91 15 ID (general)

S/N 0.12 His S

~ 13 10 09/91 BOB OD (general)

- S/N 0.43 4

+29.68 13 56 09/91 000 0D (generat)

S/W 0.28 3 3

13 65 09/91 BOB ID (general)

S/W 5.95 HTS-P

+18,51 13 78 09/91 iS ID (general)

S/N 0.16 HTS-S

+ 0.04 09/91 is

-IJ (general)

S/N 0.16 HTS S

  • 0 04

- 09/91 TS 10 (general)

S/N 0.12 HTS S 09/91 TS.

10 (general)

S/W 0.16 HiS S 13 111 09/91 TS ID (generat)-

5/N 0.12 HTS S

+ 0. 04 14 60 09/91 608 ID (general)

S/N 5.24 HIS P

+18.91 14 61 09/91 BOB 10 (general) 63 % TW 7.09 HTS '

+ 6.31 14 69 09/91 800 ID (general)_

55 % TW 6.63 HTS P

+ 7;38 09/91 SI 10 (generat)

S/N 0,79 HIS-P

+ 7.34 14 97 09/91 808 00 (general) 50 % TW 1.25 17

+13.75

- 09/91-51 JD-(general)

S/N 0.81-17

+13.92 14 498 09/91 808_ ID (general) 75 % TW 4.40 HIS P.

+14.14 15 ~28 09/91 Boa 00 (general).

3 % TW 0.67 6

+35.84 r:

09/91 51 00 (general)

S/N 0.80 6

+36.70

--15 102 09/91 TS ID (general)

S/N.

0.11' HTS S

+ 0.04

-15 105 09/91 808-- ID'(general) 64 % iW 6.22 HIS-P

+ 9.48

-15 112 09/91 808 10 (general) 99 % TW 17.70 CIS-P 1.77 e - 18 09/91 BOG - 00 (general)

S/N 0.31 11 09/91 808' OD (general)

S/N 0.69 11

+25.10

- 09/91 SOB 00 (general)-

S/N 0.45 11

+21.28

. 16 3h 09/91_IS ID (general)

S/N 0.28 HIS S, 2.88

- 09/91 - TS

-ID (general)

S/N 0.20 HTS-S

- 2.88-09/91 15 ID (general)

S/N 0.15 HIS S

- 2.88

'16 -44 09/91 is ID (genwrat)

S/N.

0.24 HTS S

+ 0.16

-16 50 09/91 TS

-ID (general). - S/N 0.16 HIS-S

-+ 0.08 09/9L IS - ID'(general)

S/N O 16 MTS-S

+ 0.08 l'

16 101 09/91= BOB 00 (general)

S/N 0.38 3.

-+ 0.05 16 102 09/91 BOB - DD (general) 16 % TW 0.55 4

+18.52

.17 4 09/9I BUG 00 (general)

S/N 0.39 1 -

+ 0.05 i

l.

17 54 09/91 15'.

10 (ganerat)--

S/N 0.24 MIS S 0.12

+

17 73 09/91_PJB 1 00 (general).

-S/W 0.33 6

_+ G.08 17 101 09/91 >00 00 igeneral)

S/N 0.32 3 0.13

+

18 58 09/91 c.oS (D (generat).

40 % TW =

3.73 HIS S

~

,__. _. ~...

-.. ~ ~

1+=

. 4;

~ Dutjn.TusAH(IM) (vte. 3.0)****** Monday November 9, 1992-08:57 Am ** **** BAscocg & Wit C0x Co. * * * * *

  • Page 3'

' Plant McGUIRE UNti 1 Steam Generatorr C

-.Out ages :

-09/91 BOB 09/91 SLV 09/91 IS D9/91 St

DutRY
AtlACHM(Nij) INDjCATIONS Of IMPfkfECTIONS' kOW CGl OU1 AGE INDICAilDN VALU[

VOLIS LOCAll0N INCHES

...4..

09/91 is ID (general)-

5/N 0.24 NIS S

+ 0.07

= ;

09/91 is ID (general)

S/N 0.73 HIS S

  • 0.08 18 69 09/91 908 10 (general)

S/N 5.78 Hi$-P

+ 8.?9 73 09/91 is ID (general)

$/N 0.14 His S 0.52

=18 75 09/91 is

-10 (generat)

S/N 0.15 kiS-S

- 0.2/

09/91 15

'lD (general)

S/N 0.04 HIS S

- 0.34

.18. 80 09/91 15 ID-(generat)

S/N 0.21 His S

+ 0.10 09/91 is 10 (general)

S/N 0.14 HIS S

+ 0.07 09/91 15 10 (generat)

S/W 0.14 HTS-S

- 0.24 18 51 09/91 TS ID (generat)

S/N 0.21 His S 0.07 18 68 09/91 75 ID (general)

S/N 0.04 HIS S 1.15 09/91 is ID (general)

S/N 0.11 HIS $

- 1.19 18

'? 09/91 IS ID (general)

S/W 0.15 His S

- 2,07 18 98 09/91 800 DD'(generat)

S/N 0.27 3.

+ 0.03 18 104 09/91 000 0D (generat)

S/N

.0.28 4 0.03 19 49 09/91 IS 10 (general)

S/N 0.16 HIS S

+ 0.20

'19 57 09/91 Boa 00 (general)

S/N 0.28 2

- 0.05

19 63 09/91 B00 00 (generot )

S/N 0.20 1

+ 0.02 19 67 09/91 800 00 (generat)

S/N

~9.16 3

- 0.03 19 68 09/91 IS 10 (general)

$/N 0.14 NIS S

- 0.42 19 74 09/91 808 00 (general)

.17 % TW 0.79 12

+20.27 19 78 09/91 000 10-(general) 44 % TW 6.52 HTS P

+ 4.47

~09/91 is ID (general)

S/N 0.14 HIS S V.10 19 90 09/91 IS 10 (general)

S/N 0.26 His-S

- 3.19 19H 91 09/91 BDB OD (general) 11 % iW=

0.81 11

- +40.84 20 50 09/91 Bou 00 (general) 18 % TW 0.66 3

+10.86 20 88 09/91 15 10 (generat)

S/N 0.24 HIS-S

+ 0.17

-20 89 09/91 TS

.J (generat)

S/N 0,11 HYS-s 20 94 09/91 15-10 (general)

S/N 0.15 HTS S

+ 0.11 21-55 09/91 TS 10 (general)

S/N 0.20 HTS S

+ 0.3?

l 21 64 09/91 is 10 (general)

S/W 0.10 HIS S

+ 0,03

.09/91 75 10 (general)

S/N 0.14 HIS-S

- 0.07 09/91 15

-ID (general)

.$/N 0,03 HIS S 0.14 09/91 15 10 (general)

S/N 0.03 HIS S

- 0.14 3

21-. 65 09/91 iS 30 (genernt)

S/N 0.14 HIS S

+ 0.07 21 6/ 09/91 1806 00 (general) 1 % Tv 0.73 3

-* 6.26 21 68 09/91 15-ID (generat)

S/W 0.27 His S

+ 0.20 09/91 IS S/N 0.24 HTS S

+ 0.14 21 '79 09/91 is ~ 10 (generat)- ' S/N 0.14 HTS S 0.17 10 (general)

-22 25 09/91 BOR OD (general)

S/N

0.23 6

'+30.11 22 6? 09/91 1$

ID (general) - S/N 0.17 His-S

+ 0.05

.22 69 09/C'.15 ID (general)

S/W 0.21 HTS S.

+ 0.10 22 105 09/91 000. 00 (general) 9 % TW 0.72 17

-+ 3.21 23 9 09/98 808 00 (general) 2 % IW.

0.82 HIS-S

+20.07

24. 38 09/91 806 00 (general)

S/N 0.63 1 09/91.$1 00 (general)

.5/N 0.26 1

+ 0.21 24-53 09/91 is: to (general)

S/N-0.20 HIS S

+ 0.19 -

24' 62 09/91 15 10 (generat)

$/N 0.12 HYS+s 09/91 IS

-10 (general)

S/N-0.16 HTS S.

?4_c 67 09/91 IS ID (general) - S/N O'15 HIS S

+ 0,15 24 -17.09/91 is ID (general)

.S/N 0.28 HIS-S:

+ 0.28 09/91 IS ID (gensrat)

- S/N 0.17 His-S'

  • 0.21-24 78 09/91 808 !D (general). S/N '

1.3.3 CTS-P

- + 8.46 24 89-09/91 800 0D (generDL)

S/N 0.30 17 24 '99 07/91-iS ID.(general)-

$/N

'O.17 nis S-

+ 0.24 25 7 09/91 BOB 10 (general)

S/N 1 1.45 his P

. +11.05 25 53 09/91 15

.!D (generat)

. S/N 0.32 his S.

+ 0,27

/S 68 09/91 15 10 (general)

S/N 0.24 HfS-S

' + 0.16

.09/91 is 1D (general).

S/N.

0.20 RTS S '

+ 0.16 09/91 15 10 (general).. S/N:

. 0.16 H15 5.

+ 0,12

??5 71 09/91 IS';ID (generat)

S/N 0.24 HIS S

+ 0.12.

= 25 77 09/91 008 00 (genernt)-

4 % iW-0.46 6 -

+ 9.57 27 -22 09/91 008 ID (general)

$/N 1.50 HTS P

+ 5.48'

.27 31 09/91 800 00 WEAR.

21.% TW 1.06 AVB3 27 -39 09/91 IS 10 (general).

S/N 0.20 HTS S

+ 0.16

-27. 42 09/91.15 10 (generat)

S/N 0.20 His S

.

  • 0.16 09/91 is ID (genernt) 5/N -

0.16 HTS S

+ 0.20

+

4 4

3

.-r

,e

,n, y

~

,-mi

.)

            • DUKE 1U0AN(fM) ( VE R. 3.0)* * * * " Monday Noveder 9, 1992 08:58 AM ++**** BABCoct & Wilton to. ****** P60e 4

Pidnt: McGUlpf UNil 1 Steam Generator: C Dutages:

09/91 808 09/91 Stu 09/91 is 09/91 51 INDICA 110NS Of IMPERflCil0NS OUCRf: AffACHM(Nij.

RDW COL CUT AGE INDICAllON VALUE VOL15 LOCATIDN thChfS 09/91 15 ID (generat)-

5/N 0.20 Nft S

+ 0.16 27 44 09/91 f5 10 (general) 5 /'.

0.20 HIS-S

+ 0.12 09/91 is ID (generat) 5/N

-0.16 HTS S

+ 0.12 09/91 IS ID (general)

S/N 0.16 HTS S

+ 0,12 0?/91 T$

ID (general) 5/N 0.16 HIS S

+ 0.12 09/91 IS ID (general)

$/N 0.16 415 5

+ 0,08 27 /4 09/91 800 10 (generat) 43 % TW 3.43.. _ a

  • 11.47 27 73 09/91 TS 10 (general)

S/N

0. 79 H f 5 5 0.16 27 81 09/91 B00 00 (general) 20 % TW 0.14 3
  • 0.05 27 104 09/91 808 ID (general) 40 % TW 3.49 H15 5 09/91 is ID (general) 5/N 0.36 His-5

+ 0.28 09/91 15 TD (genernt)

S/h 0.28 HTS-S

  • 0.28 09/91 is ID (general)

$/N 0.24 HTS S

+ 0.24 09/91 IS ID (gerwr al) s/N 0.28 HTS S

+ 0.?4 27 106 09/91 15 ID (general)

S/N 0.20 His S

  • 0.?0 09/91 is 10 (generat)

S/N 0.20 His-5

+ 0.20 09/91 IS ID (general) 5/N 0.12 HTS-5

+ 0.20 09/91 is ID (general)

S/N 0.20 HTS S

+ 0.12 28 30 09/91 B08 OD (general)

S/N 0.26 4 28 37 09/91 808 00 wt AR 13 % TW 0.57 AV34 28 42 09/91 808 00 (general) 5/N 0.22 2 28 43 09/91 B00 00 WEAR 10 % TW 0.42 AvB2 28 55 0?/91 B00 00 WEAR 14 % TW 0.63 AVB1 28 57 09/91 Bos 00 (general) 5/N 0.40 9

+23.41 28 61 09/V1 15 10 (generat) 5/N 0.24 H15-5

+ 0.12 28 79 09/91 lb ID (general)

$/N 0.24 HIS S

  • 0.16 29 50 09/91 808 00 WEAR 12 % TW 0.51 Av81 29 91 09/91 B0H (o (generat) 2 % IW 0.71 6

+18.97 29 105 09/91 Boo 00 WEAR 12 % TW 0.50 AV03 30 48 09/91 Boa DD (general)

S/N 1.04 8

+ 3.93 30 64 09/91 BOS OD (generat) s/N 0.16 4

+ 0.03 30 105 09/91 BOB 00 WEAR 19 % TW 0.94 AVB2 09/91 800 00 WEAR 21 % IW 1.07 Av83 31 48 09/91 15 ID (general)

S/N 0.20 HIS S

+ 0,07 09/91 15 lD (genernt)

S/N 0.16 HTS S 31 53 09/91 15 ID (gereral)

S/h 0.24 His S

+ 0.20 09/91 15 ID (general)

S/N 0.16 Hra S

+ 0.20 09/91 Y$

10 (general) s/N 0.16 HIS S

+ 0.16 31 76 09/91 TS 10 (general)

S/N 0.20 HTS-s

+ 0.12 31 79 09/91 l$

10 (general >

S/N 0.16 His S

  • 0.08 32 61 09/91 000 00 (general) 1 % TW 2.99 15

+ 2.37 09/91 51 00 (general)

S/W 0.45 15

+ 2.44 12 69 09/91 15 ID (general) 5/N 0.21 HIS $

+ 0.14 35 29 09/91 f5 10 (general)

$/N 0.20 His S 0.94 35 33 09/91 00s to WEAR 23 % TW 1.18 Aval 31 46 09/91 000 00 WEAR 20 % TW 0.99 AVB2 31 49 09/91 15 ID (general) 5/N 0.20 HIS S

+ 0.01 09/91 15 10 (generol)

$/N 1.10 His 5 0.03 33 89 09/91 Boa 00 (9enerat) 13 % tw 0.41 3

+19.33 09/91 B00 00 (general) 5/N 0.80 3

+24.28 33 94 09/91 600 00 (general) s/N 0.19 4

  • 0.08 33 102 09/91 RGB 00 WE AR 11 % IW 0.47 Av83 09/91 B00 00 WE AR 21 % TW 1.07 AVB2 34 /4 09/91 iS ID (general)

S/W 0.17 Ht$-s

+ 0.14 34 77 09/91 IS ID (generat) f./ N 0.15 His $

+ 0.15 ad 1.84 HTS P

+ 4.29 34 86 09/91 GOG 10 (gener al) c 34 101 09/91 B00 OD WC AR 12 % fw 0.50 Av82 09/91 000 00 WE AR 12 % TW 0.50 Av83 15 19 09/91 608 00 WEAR 21 % iW 1,02 Av82 35 46 09/91 008 00 WE AR 18 % IW 0.86 Av81 35 4S 09/91 808 00 WEAR 14 % tw 0.64 Av81 35 56 09/91 Son 00 WEAR 18 % IW 0.87 Avs1 35 100 09/91 Bos 00 WEAR 23 % TW 0.85 Avn3 36 4 7 09, v1 800 00 WEAR 15 % tw 0.66 Av01 36 70 09/91 BUG 10 (general) 50 % i.

2.37 His-P

+ 7.25 36 95 09/91 TS ID (general) 5/N 0,14 His-S

+ 0.17 36 100 09/91 Boa 00 WEAR 19 % TW 0.79 Av83 9

1

. ~ -

_. - ~ ~- -.~-

  • * * *
  • DOK E ? T UBAk(IM ) (VE R. 3,0)* * * * *
  • MWar N0"*

N#

.-Plant: McGUIRE ONii 1 Steam Generator: C Outngest D9/91 800 09/91 $LV 09/91 is 09/91 SI IMPE RIE Ci t tm 5

' QUERY AffACHMEN! 3..IhDICAfl0NS OF ROW E0t OUTAGE INDICAil0N VA1.UE V0ti$ LOCA1lON. INCHE$

37 47 09/91 BOB 00 WE AR 13 % TW 0.51 AVB1 c

37 92 09/91 DOH ID (general)

$/N 2,13 Hl$ P

  • 4.23 38 31 09/91 608 00 WEAR 28 % TW 1.59 AVB3 09/91 B($ - 00 WEAR 19 % TW 0.95 AVB4 18 39 09/91 000 DD WEAR

$1 % 1U

'.88 AV83 38.49 2 7.'a

  • anr, 00 WrAR 34 g Tw k,10 AyB2 09/91 800 00 WF AR 47 % TW 4.36 AVB3 36 52 09/91 R00 Gu WEAR 16 % TW 0.73 AVal 38 44 09/91 500 00 (general) 12 % TW 0.31 2

+12.03 39 29 09/9s B00 OD WEAR 28 % TW 1.60 AVB2 39 32 0V//1 BOG 00 WEAR

.16 % TW 0.72 AVB2 39 36 09/91 000 00 WE AR 34 % TV 2.29 AVB3 09/91 B06 00 WEAR 45 % TW 4.13 AVB2 09/91 n0B 00 WEAR 22 % fW 1.10 AVB1

_ 39 39 09/91 000 00 WEAR 15 % tw 0.67 A /03

. 39 44 09/91 BOB 00 WE AR 42 % IW 3.54 Av82 09/91 HOB 00 WEAR 32 % IW 2.01.AVB3 39 50 09/91 BOB 00 WE AR 21 % TW 1.04 AVB1

-39 52 09/91 000 00 WE AR 15 % TW 0.67 AVB1 39 58 09/91 hob 00 WEA4 15 % TW 0.68 AVB1 09/91 BOU 00 WEka

-13 % TW 0.56 AVB3 39 82 09/91 BOB 00 WEAR 25 % TW 1.39 AVB2 40 20 09/91 808 OD WEAR 111 TW 0.58 AVB2 40 26 09/91 B08 00 WEAR 15 % 'IW 0.65 AVB1 40 39 09/91 000 00 WE AR 15 % tu 0.65 AVB2 40 41 09/91 Boe 00 WEAR 31 1 IW 1.95 AVB2 40 42 09/91 B08 00 WEAR 21 % TW-1.03 AVB2 09/V' BO6 00 WEAR 14 % TW 0.62 AVB3

-40 43 09/9 008- 00 WE AR 10 % TW 0.40 AVB1 09/91 800 00 WEAR 21 % TW 1,02 AVB2 09/91 BGB 00 WEAR 22 % IW 1.15 AVB3 09/91 BOB 00 WEAR 15 % 10 0.70 AVB4 140 46 09/91 Boa OD WEAR 15 % iW 0.67 AVH1

~ 40 47 09/91 800 00 WEAR 24 % TW 1.29 AVB1 40 48 09/91 808 00 WE AR 16 % TW 0.73 AVB1 40 60 09/91 80s 00 WE AR 14 % TW 0.60 AVal

.40 61 09/91 00G 00 WEAR 21 % IW l.06 AVB2 40 64 09/91 Boa 00 WEAR 13 % IW 0.59 AVB1 40 65 09/91 boa. 00 WEAR 14 % TW 0.61 AVB1

'40 '71 09/91 B00 00 WEAR 13 % TW 0.59 AVB1 40 80 09/91 008 00 WEAR 13 % TW 0.55 AVB1 40 81 09/91 BOG 00 WEAR 12 % TW 0.54 AVB2 40 - 82 09/91 806 00 WEAR-11 % TW 0.47 AVB2 40--83 09/91 BGB OD WEAR 13 % tw 0.57 AVB2 09/91 800 00 WE AR 15 4 tw 0.65 AVB3 41 21 09/91 BOR 00 WEAR 8 X !W 0.34 AVB1 41 -24 09/91 008 00 WEAR 22 % TW

-1.09 AVB2 41J 39 09/91 80G OD WEAR 19 % iW 0.91 AVB2 55 09/91 Bon 00 WEAR 18 % TW 0.85 AVB2.

r 41.-92 39/91 f5 10 (generat) 5/N 0.14 HT$+S.

+ 0.07 42 30 09/91 B00 00 (general) 1 *. T W 0.59 19 -

+ 7.65 42.

'9 09/91 800 10 (generol).

48 % 1W 4.59.HistP

+11.62 42 87 09/91 808 (X) WEAR 13 % IW 0.53 AVal 09/91 Boa 00 WE AR 171 TW 0.80 Av83 43 33 09/91 800 00 WEAR 17 % 1W 0.79 AVB2-09/91 HOB 00 WEAR 20 % tw

.1.01 AVB3-43-47 09/91 000 00 WEAR 23 % TW 1.18 AVB1

- 43 48 09/91 808 00 WE AR 15 % TW 0.67 AVBt

43 f$3 09/91 808 OD WEAR-18 %'fW.

0.86 AVD1 43 50 09/91 000 - 00 WE AR 18 % TW 0.83 AVB1 43' 54 09/91.80s 00 WEAR-17 % TW 0.82 AVB1 43~ 55.09/91 BOB 00 WE AR -

17 % TW 0.80 AVB1 43 56 09/91-E06 00 WEAR 27 % TW 1.54 A'B1 V

41 61 09/91 BOB 00 WE AR -

15 % TW 0.70 AVB) 43 -74 09/91 808 00 (generat)

$/N 0.41 6-44 23 09/91 Bon- 00 (general) 12 % TW 0.45 2

+ 1.06

_09/91 51. 00 (general)

S/N

.0.37 2

+ 0.99 e

e v*

4 4

Pe m

1 y

y h

Frt

.~...

.. ~

eL l9 DUKEi-TUBAN(TM) (VER. 3.0)*""* Monday Novenber '. 9,.1992 08:59 AM.**"" BABCOCK f. W1(COX CO, """ Page 6

i Plant: McGUIRE UNil 1 Steam Generator: C Dutages:

D9/91 BOB '09/91'SLV 09/91 IS 09/91 SI

- QUE RY:: ATT ACHMENi g IkolCAfl0NS Of IMPERFECTIONS -

RDW COL 0UTAGE IkolCA110N I VALUE VOLIS LOCA110N -INCHES

~

44 B8 09/91 15 lb (general)

S/N 0.15 HIS-S.

+ 0.11 46; 64 09/91 15 10.(general)

S/N 0.48 HIS-S

- 1.94 46.85 09/91 is 10 (general)

S/N 0.16 His S

+ 0.12 46 87 09/91 IS 10 (generet)

$/N 0.16 HIS S

+ 0.16 48 81 09/91 is ID (general)

S/N 0.12 HIS S

+ 0.08

~4V 39 09/91 B00 00 (general) 12 % TW 0.68 16

+ 0.03 09/91 B00- 00 WEAR 11 % TW 1.04 17 09/91 SI 00 (general).

S/N 0.52 16

+ 0.07 09/91 SI 00 WEAR 15 % TW 0.17 17 49 41 09/91 800 00 (general)

S/N 0.47 14

- 0.05 09/91 BOB 00 WEAR 26 % TW 3.23 16 09/91 808 00 WEAR 16 % IW 1.85 17 09/91 SI 00 VEAR 17 % TW 0,26 14 09/91 SI 00 WE AR 23 % TW 0.39 16 09/91 St OD WEAR 15 % TW 0.23 17 49 64 09/91 is 10 (general)

S/N 0.08 CTS S

+ 0.77 49 70 09/91 BDB 00 (general) 7 % TW 0.54 12

+ 1.16

'49 71 09/91 B00. 00 WE AR 14 % TW 1.50 16 09/91 TS 10 (general)

$/N 0.16 CTS S

+ 1.13 49 73 09/91 B00 00 WEAR 10 % TW 0.94 16 49 74 09/91 808 00 WEAR 16 % TW 1,76 14 09/91 000 00 WE AR

?9 % TW 3.71 16 49 75 09/?1 808 00 WE AR 33 % TW 4.52 16 49 79 09/91 000 00 WE AR 19 % TW 2.15 16 23; TOTAL TUBES FouND 2

101AL INDICATIONS FOUND 5

359 e

y

v.

q-e*e*** DUtg 'IUSAN(TM) (VfR. 3.Q}e***** Monday November =

9, 1992 09:02 AM ****** BABCOCE&WILCOXC0f******Page.

1

~ ~

Flanti McGUIRE UNIT 1 Steam Generatort 0 Outages:

09/91 Boa 09/91 SLV 09/91_15 09/91 SI outav: AT T ACHMlNI dL t hDj CAT IONS Of IMPfRfftfl0NS.

ROJ Cot OUT AGE

-INDICAi!ON VALUE VOLTS LOCAll0N INCHE$

r,

,.....-.+....................

'.2 11 09/91 HOB lb (general)

S/N.

1.40 HIS P

  • 5.41 2.16 09/91 TS 10 (general)

S/N 0.59 CTS-S 0.35 09/91 IS 10 (general)

S/N 0.51 CTS S

- 0.43 09/91 T5 10 (general)

S/N 0.3? CTS-S

- 0.59 09/91 15 ID (general)

S/N 0.28 CTS S 0.63 2 29 09/91 BOB ID (general) 48 % IW 5.64 HIS P

+ 5.52 2 38 09/91 15 10 (general)

S/N 0.39 HIS S

- 3,15 09/91 is ID (general)

S/N 0.20 HIS S

- 3.23-2 39 09/91 BOB ID (general)

S/N 1.36 His ?

+10.75 i

2 52 09/91 TS ID (general)

$/N 0.20 HIS-S

- 1.38 2 61 09/V1 BOB 10 (generet)

S/N 3.16 "is-P

+ 7.41 2 74 09/91 SLV 10 (generat) 53 % TW 3.70 HIS P

+11.70 2 89 D9/91 808 JJ (general)

S/N 1.12 HIS-P

+1b.48 1

09/91 TS 10 (general)

$/N 0.35 His S 2.61 1

09/91 TS 1D (general)

S/N

.0.20 MTS-S

- 2.73 3 27 09/91 IS ID (general)

S/N 0.35 HIS S 3.44 3 32 09/91 ROB 10 (generel)

S/N 1,32 HIS P

+19.36 09/91 15 10 (general)

S/N 0.16 His-S 1,46 09/91 TS ID (genernt)

S/N 0.39 HTS-3

- 1.50 09/91 15 ID (generat)

S/N 0.32 HTS-S

- 1.50 09/91 iS 10 (general)

S/N 0.32 HTS-S

- 1.50 09/91 iS ID (general)

S/N 0.20 HIS S 1.54 09/91 IS 10 (general)

$/N 0.32 HIS-S

- 1.58 09/91 15 ID (general)

S/N 0.12 MfS-S

- 1.65 3 35 09/91 StV ID (general)

S/N 2.07 HIS-P

+ 8.14 3 4D 09/91 000- ID (general)

$/N 6.42 HTS-P

+16.24 3 46 09/91 BOB ID (general)

S/N 1.88 HIS P

+ 16. 73 3 75 09/91 is ID (general)

$/N 0.32 H15 5

- 3.64 09/91 is 10 (generat)

S/N 0.32 HIS-S

- 3.68 3 76 09/91 000 ID (general)

$/N 1.21 HIS-P

+18,43 09/91 15 ID (generat)

$/N 0.20 His S

' 2.44 3 80 09/91 808 ID (general)

S/N 1.50 HIS P

  • 17.50 09/91 IS 10 (general)

S/W -

0.28 His S 3,49 09/91 is ID (generat)

S/N 0.28 HIS S 3.68 09/91 iS ID (general)

S/N 0.28 HIS-S

- 3.68 09/91 IS ID (general)

S/N 0.12 HIS-S

- 3.80 3 100 09/91 800 DD (general)

S/N 0.79 1

- 0.05 l'

4 35 09/91 TS 10 (general)

S/N 0.16 HIS-S

+ 0.12 4 41 09/91 808 ID (general) 65 1 tw 15.42 MTS P

+ 1.77 4 55 09/91 TS 10 (general)

S/N 0.24 HTS S

- 3. 74 4 71 09/91 000 DD (generat)

S/W 65 6

+26.38 a

09/91 St 00 (general)

S/N

'6=

+25.80 4 79 09/91 TS ID (general)

S/N 0.16 HIS S 1.83 09/91 IS 10 (generat)

S/N 0.16 His S -

- 1.83 4 -84 09/91 Boa 10 (general)

S/N 2.27 HTS-P

+10.88 5 40 09/91 is 10 (general)

$/N 0.20 HIS S

+ 0.16~

09/91 TS 10 (general)

S/N 0.20 HTS-S

+ 0.12 5 42 09/91 15 10 (general)

S/N 0.20 H'S-S

+ 0.16 5 61.09/91 51 00 (general)

S/N 0.33 HIS-S

- 6.42 09/91 $1 OD (general)

S/N 0.24 HTS-$

- 6.47 5 67 09/91 808 ID-(generat)

$/N 1.51 HTS-P

+13.47 5 63 09/91 BOR ID (generat) 60 % TW 4.09 HIS P

+10.68

~6

-6 09/91 is ID (general)

S/N 0.12 MTS-S

+ 0.08 6 TO 09/91 SLV ID (general) 63 % TW 5.25 HIS-P

+ 9.72 6 35 09/91 BOB ID (generat)

S/N 2.70 HIS-P

+ 8.59

-09/91 is ID (general)

S/N 0.24 HTS S

- 2.45 6_

37 09/91 Siv 10 (generat) 70 % Tw 10.12 HTS-P

+ 0.89 6'

46'D9/91 St ID (general)

S/W 0.28 HTS-S

. + 0.09 6 67 09/91 TS ID (generat)

S/N 0.32 HTS S

- 2.56 09/91 IS. ID'(generat)

S/N 0.24 HIS-S

- 2.60 09/91 TS 10 (generat)'

S/N 0.24 HIS-S 2.64 09/91 is ID (generat)-

S/h 0.20 HIS S'

- 2.64 09/91 IS-ID (general)

$/N 0.12 HIS*$

- 2.68 -

09/91 is 10 (general)

S/N 0.16 HIS-S

- 2.68 09/91 15 ~ 10 (general)

S/W 0.24 HIS S

. 2.68 09/91 75 ID (general)

S/N 0.12 HTS S

- 2.72 1.

68 09/91 808 'l0 (general).

S/N 1.88 HIS P

+17.22 a

y-

.m e

y-w-

w v wN

            • Dat IuhAN(IM) ( Vl li. 3.0}****** Mudy wvader 9,1W2 09:0? AM * * * * *
  • B AB00C f & Wil COs (.0.
            • Iage 2

t-lent: Mc t.U l t( 0411 1 Sita* fe'*tetor: D Outoges:

(?"/V1 M*

09/91 StV 09/V1 lb 07/91 il eg n. g i g g,,q n; 4 I gg; ti g j og, of [ma su t ti ltm5 6 N t Ol mf AM ikDICAll0N y At ut Vot i s L OC A f l 0% I N C H15 07/91 15 ID (geret al)

$/N 0.32 Nf5 5 3.54 DV/91 f5 10 (generat)

%/N U.24 pfS 5 3.57 09/V1 15 ID (gere'at)

S/N 0.20 Mf5*5 3.57 6 6V UV/V1 15 ID (gener al) 5/N 0.12 Hitc 5

+ 0.1; f.

8/ OV/V1 000 ID (geret al) 5/W 3.62 H15 P

+14.37 0 91 ov/9. 15 lb (general)

$/N 0.20 His %

  • 0.08 6 191 Dv/V1 ft ID (gener al) 1./ N 0.04 Ht5 $

1.26

/

f.0 07/91 bob ID (generat) 5/N 1.60 His P

+ 9.70

' 61 07/91 15 ID (general) 5/W 0.16 Hib t 2.62 7 6? 07/91 ttV ID (general)

$/N

3. ' 3 H1$- P
  • 15.16 7 71 Od/91 15 ID (general)

$/N 0.16 His s

  • U.DB DV/VI 15 ID g gereril) 5/N C.1? HIS'$
  • 0.05 V//41 15 ID (gener al)

S/N 0.1?

.1 $ 5

  • 0.08 7 /f UV/V1 15

!D (gener al)

S/N 0.r. H15 5

+ 0.12

/ 91 0V/91 f5 ID (general) 5/N L.35 H1$ 5 3.70 Di/V) 15 ID (gere*,L)

$/N 0.74 Nf$ 5 3.82 B /5 07/i1 000 ID (gener at )

70 % IW 19.35 Nts P

  • ?.62 DV/91 H081 10 (gerwral)

$/N 2.08 HIS=P

+ 9.67 8 26 DV/91 005 10 (gerwr. t )

S/N

? 42 Hit P e 4. 75 OV/V1 15 ID (generat) 14 X IW 0.16 C15-5 1.80 07/91 15 10 (generat) 10 % T W 0.17 tts 5 1.80 07/91 15 ID (generat) 8 % IW 0.04 Cis 5 1.80 07/V1 f%

ID (general) 12 % TW 0.08 tis t 1.na OV/V1 15 ID (genernt) 31 IW 0.1? C15-5

?.95 09/91 1,.

!D (gerxtal) 6 % TW 0.?S C15 5

?.99 07/91 15 1D (generals 10 % Iw 0.35 (15-5

?.99 03/V1 ft ID (gener al) 1? % 1W 0.37 Cis 5 7.99 07/91 15 ID (gercral) 8 % 1W 0..**B CTS 5 2 59 07/V1 f t.

ID (gerwr nl) 4 % IW 0.20 C15-$

1.03 OV/V1 la ID (gener al) 3 % 1W 0.16 015 5 3.07 09/V1 15 1D (gererr.1) 3 % 1W 0.18, Cis s 3.11 h 61 07/91 15 ID (gercrat )

S/W 0,24 HIS 5 0,63 8 65 09/91 hull ID (general)

$/N 1,73 HI L-P

+10.57 09/V1 000 ID (geno al) 5/N

?.33 HIS P

+ 15. M S 66 N/V1 4 5 ID (genef at )

7 % IW 0.12 (15 5 3.72 8 /4 Ov/91 (19B (D (general) 65 % tw 7.04 hiS-P

+ 6.7V P 75 09/91 15 ID (general) 5/N 0.?0 N15 5 3.04 8 /6 Ov/V1 Ima 1D (ger.er al) b5 % TW 11.94 His-t

+10.56 N/V1 '$

ID (gener at )

S/h 3.?0 HTS-5

+ 0.08 g

8 78 OC/91 15 s cenc r a t )

L/N 0,16 H15 5

+ 0.04 09/91 15 lu (general)

L/N 0.1? HI5 $

0.08 01 09/91 Bau ID (9t vral)

$/N 1.7V HIS-P

+13.67 09/V1 15 10 (gereral) 5/N 0./D his-5 3.74 N/91 15 (D (general) 5/N 0.D His't 3.75 8 Vl) DJ/V1 B00 ID (general)

S/N 0.76 bis P

+20,36 09/91 15 10 (neret al) 5/N 0.?O h15 5

  • 0.12 8 102 07/91 B00 ID (general) 5/N

?.01 Htt P

+16.73 9

5 N/91 lt0B 10 (general)

$/N 1.95 H15*P

  • 14. 75 9 13 07/91 Sly ID (gener al) 68 % 1W 16.65 H15 F
  • V.67 9 15 07/91 bO8 ID (general) 78 % TW 3.57 C15 F
  • 15.60 9 71 09/91 15 ID (peneral) 5/N 0.?0 H15 5 3.i?

07/91 15 10 r )ener al)

S/N 0.16 hfS-S 3.A2 9 75 07/V1 StV ID (general) 5/N 2.94 HIS P

+ 14. N V 7/ 09/91 15 10 (generot)

S/N 0.?8 H15 5 3.13 OV/91 15 ID (general) 5/N 0.16 a15 5 3.13 V tw OV/91 SLV ID t a 'ner al )

5.h 6.95 HIS P

+ 9.15 9 R1 07/91 koB 19 (g e +91) 5th 2.77 H15'r

+ 7.0/

V ft DV/91 15 ID (gt-al) 5/N 0.?0 H15 5

+ 0.1?

10 12 09/91 15 1D (gei. cal)

$/N 0.?S HIS-S

+ 0.16 09/91 15 10 (general)

S/N 0.24 H15 5 3.98 10 45 07/91 15 10 (Weneral)

S/W 0.20 HIS's 2.02 10 t>0 07/91 13 ID (general) 5/N O.?8 His-$

0.75 10 /i 09/91 000 ID (general)

S/N 0.94 d15-P

+20.55 09/91 15 (D (general)

S/k 0.24 HTS 5 0.43 N/91 1$

0 (gercrat )

sin 0.1? HTS S 0.47 10 75 07/01 1S ID (general)

S/N 0.16 Mts s

  • 0.05 09 15 ID (general) 5/h 0.16 HTS '

+ 0,0 w

.m.-~

4 L;

            • DUAI 1060N(1N) (v!R. 3.0)****** Manday Novender 9, 1992 09:03 mM ****** BARCOCK & Wittox CO. ****** Page 3

Pibat! MrGUlk! UNil 1 Steam Generator Outages 09/91 608 09/91 ttV 09/91 1$

09/91 51

)

LMHets AffACHm!NTAb ikDICAtlONS Of lHottftC110N5 VOL1pLogA110N ikCHf5 AUW COL UCIALL INDICA 11(*

VALUI

./91 fS lb (general)

$/N 0.16 HI$ S

+ 0.04 10 84 09/91 15 ID (gener al) 5/N 0.24 His t

- 2.86 U9/91 is 10 (general) 5/N b,20 H1$ 5 2.56 09/91 ft 10 (generst)

$/H A.15 H15 1 i.90 D9/91 1$

ID (general)

S/d 0.20 HIS*$

- 2.90 10 85 OV/91 h0B ID (general) 63%1W 9.09 V P

  • 11.66 jl 10 67 09/91 000 ID (general)

S/W 1.$2 0 3 P

  • 14.40 10 102 09/91 Boa UD (general) 17 % TW 0.(3 17

+20,64 09/91 $1 00 (generat )

17 0.23 17

+21.41 10 103 09/91 Bos OD (general) 9 % tw 0.38 17

+21.09 11 2 09/91 Bis ID (general)

$/N 1.$2 HIS P

+12.83 11 13 09/91 808 10 (general)

$/N

$.32 CIS P

+17.07 09/91 15 ID (generat) 5/N 0.08 CTS S 3.83 99/91 15 1D (generat,

$/N 0.04 015 5

- 3.87 09/91 15 10 (genesal)

$/N 0.04 Cis $

3.87 09/91 1$

lD (general)

S/W 0.04 C15 5

- 3.87 09/91 I$

ID (general)

L/N 0.04 015 5 3.87 09/91 15 lu (general)

$/N 0.04 Cf5 5 3.87 09/91 15 ID (general)

$/N 0.04 C15 5

- 3.87 09/91 1$

ID (general)

S/N 0.04 CTS S

- 3.87 l

11 16 09/91 600 ID (general) 45 % TW 11.32 Hf ~ P

  • 3.76 l

09/91 DOB ID (general) 40 % TW 1.23 H.s L 09/91 15 10 sgenerat) 1/N 0.20 His S

+ b.12 09/91 15 10 (general) t/N 0.16 H15 5

  • 0. *>8 11 25 09/91 15 ID (general)

$/N 0.20 His $

1.05

' 11 34 09/91 ts ID (general) s/N 0.?0 NTS s

+ 0.24 91 61 09/91 5LV 00 (general) 5/N 1.65 HTS P 16.08 11 67 09/91 15 10 (general)

$/N 0.24 His $

2.49 11 72 09/91 000 ID (general)

$/N 2.24 HIS P

  • 14.01 11 75 09/91 15 10 (generat) s/W 0.20 Mf6 5

+ 0.08 09/91 IS ID (generat)

S/N 0.16 H15+5

+ 0.08

11. 77 07/96 IS 10 (generat)

S/N 0.12 Kis+$

+ 0.04 09/91 15 ID (general)

S/N 0.08 HIS 5 11 81 09/V1 15 ID (general) 5/N 0.12 H1$ S 11 82 Da/91 IS ID (general) 1/N 0.16 Hf$ $

+ 0.08 11 84 09/91 BOB ID (general)

S/N 2.51 H15 P

  • 11.14 09/91 000 ID (general) t/N 2.78 HIS-P

+13.93 11 85 09/91 B09 10 (generat) 88 % TW 9.26 HIS P

  • 9.72 11'94 09/91 000 1D (generat) 5/N 0.92 His P

+19.60 09/91 15 ID (general)

S/N 0.12 His S

+ 0.04 09/V1 15 10 (generos) 5/N 0.39 HIS S

- 1,42 11 96 D9/91 BOB 10 (general)

S/N 1.75 N15 P.

+17.44 09/91 15 ID (gtneral)

$/N 0.43 H18 5-

-3.$4 11 97 09/91 15 ID (general)

S/N 0.20 His+s 2.44 i2 4 09/91 000 OD (ge.ieral)

$/N 1.00 2

+17.00 12 20 09/91 15 ID (general)

$/N 0.20 Hl$ s

.+ 0 Da 12 25 09/91 is ID (general)

S/N 0.24 His S 1.02 12 27 09/91 1$ ID (general)

S/N 0.24 H15 5 1.03 12 30 09/91 is 10 (general)

S/N 0.20 HIS S

- 4.06 3

09/91 IS ID (general)

S/N 0.16 H t 5 $

- 4.10

'12 55 D9/91 15 10 (generat)

$/N 0.20 HIS s

+ 0.08 12 60 09/91 15 ID (general)

S/N O.32 H15 5 0.6/

09/91 15 ID (general)

S/N 0.28 HiS S 0.78 09/91 15 ID (general)

S/N 0.28 HIS S

- 0.78 09/91 l$

_ID (general)

$/N 0,67 His S

  • 1.35 09/91 15 10 (general) s/N -

0.20 His $

1,59

'09/91 is ID (general)

$rN 0.20 His S 3.$4 13 11 09/,1 908 1D (general) 43 % tw 9.08 H15-P 12.69 09/91 BGB-ID (general)-

S/N 1.65 HIS P

  • 13.78 13 25 09/91 Ys ID (generJL)

$/N 0.28 HIS S 0.99 09/91 15 ID (general)

S/N 0.20 Hit S

- 1.03 13 36 09/91 15 ID (generat) s/N 0.63 H15 5

- 2.09 13 45:09/91 is ID (generat) s/w 0,29 His S

+ 0.08 13 65 09/91 BGB 10 (general).

63 % 1W 7.51 His P

+ 8.59 13 66 09/91 800 ID (generat)

$/N 3.31 di$ P

+12.76 13 77 09/91 800 10 (general)

S/W 1.75 HIS P

  • 14.94 13 8109/91 B00 10 (generat)

$/N

. 2.12 His P

  • 10.90

_ _ _..__ _ _.. - - ___ _ m _

..~..__.---_______-~m.

(

"*** Durt suaANt1H) (vla. 3.0)* * ** *

  • Mander Novemter
9. 1992

- 09:03 AM * ** * *

  • s'acoca a witc0x co. * *** *
  • Page 4

Pt hnt i Mc Lulkt UNil 1 Steam Generator 0

- Outages:

09/V1 6DB 09/91 $LV 09/91 1$

09/91 SI OUf k f A11 ACHut W14. INDICAllONS OF iMPip f ( Cl l DNS ktW (>t DU!AGt INDICAf!ON VALUE VQlI$ LOC A11DN I NCHl $

13 90 09/91 15 10 (general)

$/N 0.3? HIS 5

- 1478 14 ?? OV/91 t$

(D (general)

$/N 0.?4 H15'5 1.07 09/91 15 lb (general)

$/N 0.24 Hi$-3 1.07 1'

09/91 f5 ID (generat) 5/N 0.?0 Hi5 5 1.11 09/91 15 10 (general) 5/N C.20 H1$ $

1.11 r

09/91 '%

ID (general)

S/N 0.16 His s 1.11 09'e a

10 (general) 5/N 0.16 Ni$ $

1.15 f

14 29 09/9s itV ID (gener al)

S/N 3.56 H1$aP

+13.37 14 32 09/91 1$

10 (ver.eral) 5/N 0.?O His S

- 1.69 14 38 09/91 Aug 10 (stacrat)

S/N 1.47 N!t P

+14.4%

j 14 48 09/91 BOD lD (general)

$/N 1.93 HIS 4

+ 6.56 I

14 80 D9/91800 ID (general) 59 % TW 6.77 t:5 P

+ 9.5%

15 27 09/91 16 1 (t gral)

$/N 0.?O M15 5

+ 0.16 09/91 15 to (general)

S/W 0.20 H1$*S

  • 0.1?

lb 37 09/V1 15 ID (generat)

S/W 0.16 His 5

+ 0.08 15 38 09/91 BDB ID (general) 1/N 6.14 H1$ P

  • 1$,61 15 $8 09/91 1$

3D (general)

$/N 0.32 H15 5

- 1.69 15 59 09/91 000 1D (general) 5/N 4.61 HIS P

+14.93 15 60 99/91 15 10 (general)

$/W 0.?8 H15 5 b.79 15 76 09/91 15 lb (generat)

$/N 0.'6 His s

+ 0.04 09/91 15 10 (general)

$/N 0.20 H16 5

+ 0.04 09/91 15 lb (gercrat) 5/N 0.'.2 HIS*$

1$ B0 09/91 is 10 (general) 5/N 0.12 His $

+ 0.04 16 11 09/91 000 ID (geretal)

S/N 9.32 H15 P

+14.96 16 13 09/91 h0B 10 (generat)

$/N 4.0'. HIS P

+12.74 16 16 09/91 004 lD (general) 45 % TW 8.76 C1$ P

+12.29 09/91 $LV 10 (general)

S/N 7.79 H15 P

+14.6S j

09/91 St ID (gene at) 5/N 0.30 Cis P

+1?.85

=

16 17 D9/91 BON ID (general) 5/N 3.$8 Hit P

+10.97 16 ?Q 09/91 00H 10 (general)

S/W 1.69 HIS P

+ 7.?B

. 1 09/91 Hon ID (general) 5/N 3.41 His P

  • 17.90 U9/V1 in ID (general)

$/N 0.*? HIS S

+ 0 '"

09/91 15 ID (generat)

S/H 0.?4 His S 3,.*

09/91 IS ID (generat)

$/N 0.24 His S

- 2.4$

09/91 is

'ID (general)

$/N 0 ?0 His $

3./5 16 21 09/91 DOB ID (general) 68 % TW 6.65 HI5 P 417.05 3.$3 09/91 15 ID (generat)

/N

'.43 HIS S 09/91 15 ID (general) 5/N 0.16 N15 5 3.73 09/91 15 ID (general) 5/N 0.16 HIS S

- 3.73 09/91 15 10 (generat)-

$/N 0.16 N15 5

- 3.73 16 57 09/91 908 ID (general) 5/N 7.01 HIS P

+14.10 i t, 61 09/91 is ID (gener al) s/N 0.24 H15 6 1.38 16 65 09/91 B0H 10 (pencrat) 5/N 8.39 His P

+12.18 09/91 15 10 (generat)

S/N 0.32 HIS 5

- 1.97 e

. 09/91 15 - ID (general) 5/N 0.20 HIS 5 2.01 17 $ 09/91 Stv 10 (general) 5/N 2.51 hts P 414.52 17 12 09/91 0(Mt ID (general)

S/N 1,39 His P

+17.7/-

09/91 15 10 (generat)

S/N 0.24 His s

- 3.38 09/9) IS 10 (general)

L/N 0.24 His S 3.38 09/9; is ID (generat)

$/N 0.16 HIS $

3.46 D9/91 15 10 (general) 5/N 0.12 H15 5 3.$0 17 15 D9/91 000- ID (general) 5/N 3.84 His P

+15,49

+

17 24 09/91 BD0 10 (general) 78 % tw 4.09 His P.

+13.44

17. 31 09/91 75-ID (general) s/N 0,20 His 5 4 0.0h 17 38 09/91 15 ID (general) 5/N 0.16 His-$

+ 0.12 09/91 IS ID (general)

$/N 0.16 HIS $.

+ 0.08

'17 43 09/91 15 ID (gener61)

S/N 0.16 His s

  • 0.12 17 81 09/91 IS' 10 (general) - S/N-0.20 His t 3.97

'18 4 09/91.000 10 (general)-

35;TW 6.57 HTS P

  • 10.98

' 18 14 09/91 $LV 10 (generet)

$/N 3.$5 Hf5 P

+13.45 1.1 '16 09/91 000 10 (ganeral)

S/N 2.64 His P

+15.67 to 73 09/91 is ID (general) 3/N 0.20 His 5

- 2.20

.18.34 09/91 HOB 10 (general) 5/N 2.09 HIS P

+13.*?

18 49 "9/91'15 ID (general)

$/N 0.16 HTS S

( 4

' t 18 57 09/41 15 1; (generat) s/N 0.16 H15 5

  • 0.12

- r 18 89 DV/91 B00 ID (general)

$/N

-2.?7 His P

  • 12.62 18 96 09/V1 000 10 (generat) s/N 2.74 Nfs P

. +

.'S F

g

-w j~n

~,

w +,, v ~ ' W w es &

v mw..v=-*&.---,e.e.

,-,m

%I e m

,, 'w, w

s w,

,.-_.g._,,

4

+,,,,

-~m-~~~~~------~~~-

-~ - " - - ;

b

' ' +

e Dust tuaAN(tm) (vrt. 3.0)*""* n-way Nove-twr 9, 199?

09:04 AH """ BABttgr & Witc0x Co. """ Page 5

Plant MrGt;8tt UNif 1 Steam 6enerator 0 Outages:

DV/91 Bob 09/91 Stv 09/91 15 09/91 51

-i All ACHMI N14. INDICA 11(ads (>8 INN nf 8L11(dis outet:

t MM COL OU1 A(,f IMICAll0N VALUf A. !$ OW N lHCHf S

...... ~..

19 13 07/91 BOS 10 (gertral)

S/N 6.r./ HIS P 10.87 09/91 IS 10 (general)

S/W 6.?O His S

  • 0.12 l

19 2? 09/91 BOB ID (geret a!)

S/N 1.j9 HIS P

  • 17,86 0?/91 is 10 (general)

S/N

0..'4 H I S S 3.53 09/91 15 10 (ger* rat}

S/N 0.28 Nis S

- 3.57 09/91 IS ID (generet)

S/N 0.16 His S 3.57 09/91 15 1D (generat)

S/N 0.?ri utg.S 331 09/91 1S ID (general)

S/W 0,

HIS S 3.61 J

09/91 1$

ID (gerwrot)

S/w

0.. HIS S 3.65 09/91 15 ID (gerwral)

S/N 0.08 HIS S

- 3.77 19 6?.0?/91 808 10 (general)

$/N 6.33 HiS P

+ 7.4?

09/91 808 ID (general) 55 % TW 14.98 His P

  • 13.51 1

19 to 09/91 15 ID (general)

S/W 0.16 His S 0.77 19 BT 09/91 BOB ID (gerwral)

S/W 1.$6 HIS-P

+1?.82 70 9 09/91 15 ID (general)

S/W 0.39 utS-S 3.00 2C 11 09/91 BOB ID (general)

S/N 1 71 H15 P

  • 11.64 70 70 09/91 15 10 (gerwral)

F/N 0.16 HIS S 1.00

    • 0 74 09/91 800 ID (general) 73 % TV

?.93 M15 P

+ 8.58 20 58 09/v1 BOB ID (general)

S/N 1,53 HIS P

+ 10. 75 20 55 DV/91 IKA. ID (gerwral) 40 % TW 3.15 HIS S 09/91 It ID (general)

!/N 0.2d MIS-S

+ 0 ?4 20 80 09/91 SLV 10 (gerwral) f/N 2.01 His P

+1?,97 20 90 09/91 0011 ID (general)

S/W 1.75 His P

+14,42

?0 9? 09/91 808 ID (generat)

S/N 2.12 His-P

  • 11.52 21 12 09/91 IS ID 'gerwrat )

$/N 0.35 His-S

- 1.39

?! 43 09/91 DOB ID (general)

S/N 12,43 HIS-P

+ 9,58

)

11 56 09/91 15 ID (gerwral)

S/N 0.05 CIS S

+ 0.67

21. 87 D9/91 B00 1D (generat )

5/N

?.31 HIS P

+11.57 22 10 09/91 BOB 10 (general)

S/N 7.82 His P

+16.67 09/91 IS ID (genera ()

S/N 0.08 His S 4.19

?? 30 09/91 BOB 10 (gereral)

S/N 1,74 His P

+ 5.13 22 15 09'91 800 ID -( gener al )

S/N 7.34 HIS P

+ 6.18 09/v1 IS 10 (general)

S/N 0.16 HIS S

+ 0.04

?? 38 09/91 1809 10 (general)

S/W 13.68 His P

+14.59

?? 44 O(.el IS 10 (general)

S/N 0.16 MfS S

  • 0.08

?? 45 09/91 15 1D (general)

S/W 0.1/- hts S

+ 0.1?

?! 78 09/91 Boa ID (general) 85 % TW 10.17 HIS P

+17,88 09/91 15 10 (general)

S/N 0.35 NTS4

- 2.82 09/91 IS 10 (general)

S/N 0.35 HTS S

?.82 09/91 IS ID (generat)

S/N

- 0,16 HI S-S

- 2.8?

09/91 15 ID (general)

S/N 0.39 MfS S

?.86 09/91 15 10 (general)

S/W 0.1? HIS S

?.86 09/91 is 10 (gerwral)

$/w 0.0L HIS S 2.86 09/91 IS 10 (general)

S/W 0.?8 His-S 2.90 09/91 IS ID (general)

S/N 0.?O HIS S 2.90 09/91 15 10 (gererat )

S/N 0.?8 HIS "

- 2.94 G7/91 1' ID (gereral)

$/N 0.20 HIS S

  • 2.98 09/91 TS 10 (general)

S/N 0.16 HIS S

  • 3.02 09/91 IS ID (general)

S/N 0.1? His S 3 #2 09/91 15 10 (general)

S/N

.0.16 HiS S 3.02 72 80 09/91 SLV ID (general) 48 % TW 6.04 NfS-r

+ 5.66

?? 87 09/91 IS 10 (genera ()

- $/N 0.3? MIS S 1.35 23 11 09/91 15

'ID (general)

S/N 0.?4 H15 5 -

3.97 09/91 15 10 (general)

S/W 0.24 Mf S S -

4.01 09/91 IS ID (general)

S/N 0.20 HTS S

- 4.05 09/91 15 10 (general)

$/N 0.20 MI$+5

  • 4.05

?3 19 09/91 is 10 (generat)

S/N 0.?8 His S 3.97 23 31 09/91 is 10 (general)

S/N 0.16 His S

+ 0.08-

?3 36 09/91 f5 ID (general)

S/N -

0.?4 His S

+ 0.1?

?! 46 09/91 is ID (general)

S/N~

0.?0 His S

+ 0.04 23 47 09/91 IS 10 (generat)

S/W 0.24 HIS S

- 0.?'

- 09/91 15 ID (general)

S/W 0.20 His S-

- 0.28 09/91 *S 10 (general)-

5/N 0.12 HIS S

- 0.32 09/91's ID igemeral)

S/N 0.16 HIS S

- 0.32 i

23 53 09/91 IS ID (

eral)

S/N 0.16 HIS+S

  • 0,19 09/91 1$

10 (.- erat)

- t/N 0,20 H15 5

+ 0.15 09/91 15 1D (t, aeral)

S/N 0.24 HIS+S 3.7G 9

.r-

.i--

O -.'

lw~,-

..--n--L-

?.n,~-.-n.d.--.,,,L.

-8

..n.Ln,.,

n

..w..-.,~.L-

o t

            • DUEL TUBAN(IM) (V[ R. 3.0)* * * * *' M>ndeh bovember 9, 1992 D9 ; D4 AM e..... BAEC(KK & 14tCOM CD. ****** Page 6

Plant Mc0Ulkt UN!? 1 Steam Gowrator: D i

butaget 09/91 0D0 09/91 StV 09/91 IS D9/91 Si j

DutNV2 A11ACHutNIth (NDlCAllCWS DI Ik/(b l( Cl l($ $

[

&OW Col OUIAGE I NDIC/.f l DN VAluf VDils LDC Atlfd ihCH($

73 56 09/91 B00 lb (general) 48 % tw 4.5? His P

+10.03

?3 66 09/91 IS ~ ID (general)

S/N 0.23 H15 5

+ 0.08

?$ 92 09/91 898 ID (generat) 48 % TW 7.0/ M15 P

+ 7.13 24 1' D9/91 800 1D (general) 70 % IW 3 38 CTS P

  • 16.93 24 1'

09/91 is ID (general)

$/N 0.43 Hit S 3.32-09/91 1$ ID (gereral)

$/N 0.?8 His S 3.36 74 23 09/91 kok 10 (general)

%/N 4.42 M15 P

+16.83 09/91 15 10 (general)

$/4 0.20 His S 4.01 09/9* 15 ID (weneral)

S/N 0.20 His S 4.05 09/91 is ID (general)

S/N 0.20 Hit S 4.05 09/91 is ID (general)

$/N 0.20 His S

- 4.05 i

09/91 15 ID (general)

S/W 0.16 Hi$ 5

- 4.09 09/91 f5 lb (gener al)

S/N 0.16 His S

- 4.09 09/91 15 ID (gener al)

S/N 0.16 His S

- 4.D9 09/91 is 10 (general)

$/N 0,16 HfS-S

- 4.09 09/91 15 10 (genarat) s/N 0.08 MfS S

- 4.1/

?S 29 09/91 800 ID (general)

S/W 1.61 His-P

  • 4.69 25 57 09/91 is 10 (gener al)

$/N 0.?O HIS S

+ 0.20 01/91 15 ID (general)

$/W 0.32 til S

  • 1.0?

25 54 05/91 BDH ID (general)

$6 i TW 10.76 HIS P

  • 11.36

?$ 79 09/91 808 10 (general)

S/N 6.43 HTS P

+13.16 25 81 0?/91 808 ID (general)

S/N 3.78 Hl$ P

+ 11.50 i

D9/91 15 ID (general)

$/N 0.24 H15 S 26 8 09/91 808 OD (general) 18 % 1W 0.46 :

+ 2 /.94 09/91 51 00 (generat )

$/N D.55 3

  • 27.94

?6 17 09/91 000 10 (generat) 4n % TW 12.12 HIS-P

+11.91 26 44 09/91 15 10 (general)

$/N 0.?4 Mit $

1.88

26. 47 09/91 15 ID (gcneral)-

5/N 0.24 HIS S 2.56 09/91 TS ID (general)

S/N 0.16 HIS S 2.86 09/91 15 ID (general)

$/N 0.16 HIS 1 2.90 09/91 is ID (gener al)

$/N 0.16 HTS $

- 2.90 09/91 is 3D (general)

S/N 0.16 PTS 5

- 2.90 07/91 15-10 (general)

$/N 0.12 Mfs S 2.90 2f 66 09/91 008 10 (general) 68 % IW 4.51 HTS P

  • 10.57 27 9 09/91 1S JD (general)

S/k 0.28 MfS S

+ 0.24 27 30 09/91 008 ID (general) 40 % IW 7.50 HT S-P

+10.27 27 55 09/91 1$

ID (general)

$/N 0.20 MTS S

+ 0.16 27 62 09/91 15 ID (general)

S/N 0.16 HIS S

  • 0.12 09/91 f5 10 (general)

S/N 0.12 His S

+ 0.08

.27 69 09/91 Hon 10 (genera.)

75 % TW 14.16 HIS P

  • 3,71 27 70 09/91 808 10 (general)

S/W 1.62 HTS P

  • 18.99 09/91 !$-

10 (gene.al)

$/N 0.28 H15 5 1.69 09/91 15 10 (genernt)

S/N 0.28 H15 5

.1.69 09,41 15 fn (generat)

S/W 0.24 HIS S 1.73 09/91 15 10 (general) h/N 0.24 His S

- 1. 73 09/91 TS ID (general)

S/W 0.28 HIS S

+ 1. 73 27 82 09/91 000 10 (general)

S/W 1.90 HIS P

    • 1.47 28 9 09/91 000 00 (general) 29 % IW 0.32 HIS S

+ 1,93 28 55 09/91 SLV ID (general) 48 % TW 5.69 His P

+13.12 28 70 09/91 Bou 10 (general)

S/N' 11.00 His P

+ 4.29

' 29 34 09/91 B00 ID (general)

S/N 1.78 HIS P

+16.28 2f,43 09/91 15 10 (gene?al)

S/N 0.16 H15 S

- 3.66 2V 44 09/91 808 10 (general) 55 % TW 6.97 HTS P

+ 1,63 29 46 09/91 Boa ID (genernt) 53 % TW _ 4.78 His P

+ 9.72 29 49 09/91 Bon ID (general)

S/N 2.50 HIS P

+16.66 29 66 09/91 000 10 (generat}

75 1 TV - 4.54 HIS P

+13.52 29 67 09/91 ROS to (generat) s/N

.5.38 HIS-P

+11.57

79. 70 09/91 kD8 ID (general)

S/N 2.53 HIS P.

+17,39 09/91 IS 10 (general)

$/N 0.59 nis S'

- 3.29 09/91 TS ID (general)

S/N 0.?4 H15 $

3.65 09/91 15 10 (general)

$/N 0.24 His-S

- 3.65 09/91 15 10 (general)

S/N-0.28 H15 S 3.65

- 09/ 1 IS ID (general)

S/W 0.35 Hif S.

- 3.69 9

09/91 IS ID (gereral)'

S/N 0.24 HTS S

- 3,69 09/91 is 10 (gerieral)

S/N 0.12 N15 5 3.76 D9/91 is ID (generat)

-S/N 0.20 HIS S~

- 3.76 24 83 09/91 BOB IP (c.=retat; S'W-3.00 MTS-P

+12.54 i

i

/

--. - ~.. _-.--

e-

'e i

    • " " puti tuBAN(IM) ( Vt a. 3.0 )' * '
  • Mar-day No verder 9, 1992 09:05 Aas.* *"" B ABLOU & Willox CO. '"*' Page 7

Plant; McLUlH UNif 1

$ t ciara Lerier a t or D Nt r$w t 09/91 80d OV/91 StV 09/91 1$

09/91 si 0,pn All AtprNt 4 lNDl0AflDalt Or IMPikFfC18CAS i

POW COL OU1Att 10blCAf10N VAlt)(

VUL t $ L OC A t lON INO(5 27 93 OV/V1 is ID (gerwrat) 1/N 0.63 Nf5'$

3.24 30 23 09/91 15 1D (gervrat)

$/N 0.24 His $

2.53 3D 44 D9/91 Bou f D (geretal) 61%TW 4.3' Mf$ P

  • 16.72 07/91 f ID (ge vrat)

$/N 0.28 His s 3.64 07/91 f5 10 (gercrat )

$/N 0.32 His $

- 3.68 09/91 is ID (gercrat)

$/N 0.32 Hit $

1.68 09/91 i%

ID (gerwrel)

$/N 0.28 Nf5 5 3.72 OV/91 1$

ID (general)

S/N 0.16 Mf$~$

3.72 09/91 l$

ID (general) t/N 0,16 HT$ $

3.72 09/91 15 10 (geret al) 5/N 0.20 HI5 5 3.76 09/91 11

'D (general) 5/N 0.16 Mf5 5

- 3.76 09/91 15 ID (general) 5/N 0.08 His L 3.84 30 51 09/91 15

!D (geretal)

$/N 0.16 Nfs s

  • 0.1 L' 30 52 09/91 ttv lb (general)

S/N 3.16 His P

  • 13.86 30 56 09/91 15 ID (general)

S/N 0.16 H15-5

  • 9.12 09/91 15 10 (gerer al)

$/W 0.16 MfS t

  • 0.08 lu 5B O~//91 15 ID (general)

$/N 0.12 Htt s

  • 0.12 30 61 09/91 600 lb (ger.crat )

48 % tw 4.04 HIE P

  • 5.81 09/91 DOD ID (gerwrat )

$/N 1.61 HIS P

  • 7.70 30 62 09/91

) 1D (gener al). $/N 1.34 His P

  • 16 J 5 09/91 1.

1D (general)

$/N 0.71 N'ps

- 3.07 09/91 15 10 (gererni s b/W 0.24 Hl$ 5 3.11 09/91 15 ID (general) 5/N 0.35 His s

- 3.42 L //vi '5 10 (generat)

S/N 0.20 His S 3.42 0V/91 15 10 (general)

S/N U.24 H15 5 3.46 09/91 is ID (gereral) 5/N 0,16 HIS s 3.46 09/91 15 ID (ger>crat) 5/N Q.12 HI5 S 3.54

)

30 68 07/91 BOG 10 (general)

S/N 2.82 HIS P

  • 13.00 30 69 09/91 bra ID (general)

S/N 1.74 His P

  • 7. 45 -

30 77 07/91 Bou ID (general) 45 % TW 12.01 H154

  • 13.22 31 14 09/91 600 10 (ueneral)

$/N 4.18 HIS P

  • 12.1i 31 29 D7/91 Btm iD (general)

$/N 3.21 HIS P

  • 18.18 09/91 16 ID (general)

$/h 0.32 HIS S 2.4D 09/91 15 10 (general)

$/N 0.24 H15-5 2.52 09/91 f5' ID (generni) 5/N 0.24 Mffb 5

- 2.56 n /91 15 - 10 (general)

$/N 0.16 Nf5 5 2.60 OWV1 15 h) (general)

E/N 0.20 His S 2.64 31 38 09/91 But 10 (gereral) 1/N B.84 His P-

  • 15.09 31 42 09/91 !$

ID (general)

$/N 0.28 His $

2.55 31 47 09/91 is ID (general) 5/W 0.32 Hf5 5 1.20 31 62 09/91 ft ID (gerieral)

$/N 0.16 N15-5 09/91 15 3D (generat)-

5/N 0.20 Hf$ $

09/91 TS 10 (general)

S/N 0.16 Hit s 31 - 70 09/91 BOB ID (general) 50 X TW.

10.58 His P

  • 4.31 32 3') 09/41 st v to (gerieral) 68 % IW 2.67 HIS P
  • 13.53 f,

1 32 43 DV/91 Ron 10 (gereral) 58 % IW 3.19 His-P

  • 6.01 32 5? 09/01 Iloe 00 (general) 80 % IW l.11 1
  • 0.03 32 6r. W/91 15 lD (general)

$/N 0.24 H15 i

  • 0.16 e

32 68 09/91 ItOR OD (gerwral) w/N 0.75 17

  • 2.13 33 20 09/9) 808 10 (general)

$/N 1.95 Hi4 P

  • 7.14 31 23 09/91 BOR 10 (gener AL )

$5 % IW 2.92 HIS*P

  • 11.22
33. 31 09/V1 b00 -lD (generat) 70 % TW 2.71 HIS P
  • 17.24 4

09/91 15 ID (general) 5/N 0.32 His S 3.56 09/91 is ID (general)

S/W 0.3? Hl$ S 3.64 (9/91 15 ID (general)

S/N 0.20 His S 3.68 09/91 15 ID (penerat) s/N 0.20 HIS 5 3.68 09/91 i$

ID (gerwrat )

S/N

'O.16 HTS S 3.68 09/91 IS ID (general) 5/N 0.3? His s 3.68 r

0V/91 15 ID (ger? rat)

$/N

. 0.16 His s -

3.72-i 09/91 IS 10 (ger+ rat )

5/N 0.04 HIS-$

3.80 33 39 09/91 Boa: ID (generat)

L/N

'1.13 HIS*P

  • 16.69 09/91 15 10 (generat).

$/h 0.20 HIS S 3.60

'09/01 IS lb (geret al) 5/N 0.20 HIPS.

  • 3.64 09/91 15 10 (generat)

- S/N 0.16 His t' 3.68 33 41.09/91 !$

10 (gewral)-

S/N 0.16 HTS S

  • 0.12 33 $$ 09/91 Boa CD vtAR 17 % IW 0.60 Av81 33 50 09/91 15 10 (1)eneral) 5/h 0.16 His s-l i-k k

e w-3w.+

.r,-,e

-.m.,-

,.,--,ser yt---w y,

te-e-.--

ee---,

<,w,s 4-,--,

m,,,%

.s, wm A

g y _,p e c es~,,,.s

-c-g

~

g w

eve,%

=ww

--._.,__m__m

.-._m.._

l r

    • *"
  • DWL ILS AN(ict) (vt e. 3.0)* * * * *
  • HoMa/ Weecr 9, 1992 09:09 AM * * * * *
  • SABCOct & Wilcom co. "* *" Page 8

Outages 09/91 BOB 09/91 Siv 09/91 1, 09/91 51

-Plantt McGUJti UNil 1 Steam Generator: D-

)

04RV1 ATTACHWN14 INDICA 1104S Of IHr(Rf(CilDNS

..m.

ROW COL OUT AC.f 1NDICAllON VAtut volts (OCAllON l bC Nt-S p

, 2........................

[

33 60 09/91 15 ID (general)

S/N 0.16 NTS S

+ 0.06 33 83 09/91 000 10 (general)

$5%1W 14.53 His-P

+ 9.67 i

33 97 09/91 15 ID (general)

S/N 0.20 HIS S

+ 0.12 34-37 09/91 BOB ID (general)

S/W 1.60 HIS P

+ 7.72 34 47 09/91 15 10 (general)

S/k D.16 NtS S

+ 0.04 34 60 09/918ina 10 (general)

$/N 4.04 H15 P

  • 18.23 34 61 09/91 f5 ID (general)

S/W 0.32 HIS S 3.57 09/91 15 10 (general)

S/N 0.?0 MTS S 3.65 09/91 15 10 (genarat)

$/N 0.16 HTS S 3.69 34 88 09/91 B00 ID (general)

S/N 1.80 HTS P

+ 3.79 a

35 18 09/91 800 m (general)

S/N 0.35 1

+

35 22 09/91 TS It' (general)

S/N 0.16 HTS-S

  • 0.12 35 47 09/91 is ID (general)

S/N 0.20 HTS S

- 0,89 l

.09/91 15 10 (generalj

$/W 0.12 HIS S

- 0.93 09/91 15 ID (general)

S/N 0.12 H15 5 0.93 09/91 15 10 (general)

$/N 0.12 HfS-S

- 0.93 09/91 15 ID (general)

S/N 0.04 H15 5

  • 01 09/91 is ID (gener at )

S/W 0.43 HIS-S 70 09/91 15 lb (General)

S/N 0.24 H15 5

- 2.86 09/91 is - ID (generst)

S/N 0.16 HTS S

- 3.86 09/91 1:

10 (general)

S/N 0.16 HIS*S

  • 3.90 l

09/91 15 10 (general)

$/N 0.16 HIS S

- 3.90 i

35 53 09/91 BOO 1D (gener al).

S/N 0.16 HIS S

- 3.90 09/91 15 10 (general) 40 % tw t.69 Mit S 0V/91 15 lb (general)

S/N 0.24 H15 5

+ 0.20 35 65 09/91 808 ID (general) 68 % 1W 5.37 HIS P

+14.30 35 72 09/91 BOU ID (general)

S/N 1.92 HIS P

  • 3.33 36 26 09/91 is ID (general)

S/N 0.16 H15 5

+ 0.12 36 30 09/91 15 ID (ger.eral)

$/N 0.16 H15 5

+ 0.16 36 31 0'/91 15 ID (general)

S/N 0.20 His S

- 0.79 09/91 15 10 (general)

S/N 0.12 M154S 0.83 36' 47 09/91 1S 10 (general)

$/N

'),16 HIS S

- 2.71 09/91 1S ID (general)

S/N 0,16 HTS S

2. 75

?

0.75 l

36 63 09/91 M 10 (general)

S/N 0.16 HIS S 4

'36 65 09/91 15 ID (generat)

S/N 0.12 HTS S 0.83 36 9'i 09/91 is 3D (general)

$/N 0.20 H15 5

- 0.35 09/9' 15 10 (general)

S/N-0.16 H15-5

- 0.35

,t 37 26 09/91 800 10 (general) 53 % TW 8.40 His P -

+11.31 37 50 09/91 TS ID (general) n/N 0.16 HTS S

+ 0.16 37 63 09/91 Bou ID (generat)

?O % T W --

7.35 HIS P

+12.77 3/

B+ 09/91 BOB 10 (general)-

53 % IW 4.94 HTS P

+12.69 37 97 09/91 800 00 (general)

S/N 0.44 1

+ 0.10 r

3B 17 09/91 is ID (g meral)

$/N 0.24 HfE-S

+ 0.20 33 '19 09/91-Bort ID (general)

S/N 5 86 HIS P

+16.31 38 24 09/91 BOB 10 (general) 58 % TW 5.35 HTS P

+16.39 38 4o 09/91 808 10 (generat)

BS % 1W 2.87 H1$ P

+1$,61 38 47 09/91 15 10 (general)

Ss N 0.20 His S 0.60 09/91 15.10 (general)

S/N 0.16 HIS S

+ 0.64 18 53 69/91 608 OD WI.AR 14 % iW -

0.50 AVS1 38 63 09/95 808 1D (general)

S/N 3.72 His P

+13.53 38 66 09/91 Boa 10 (general) 5N 1.95 HTS P -

+12.59 38 72 09/91 800 ID-(general)

$/N 1.93 HIS P

+11.88 38 75 09/91 15

-ID (general)

S/N 0.16 HIS S 2.48 38 77 09/91 Siv ID (generat) 50 % TW 4.54 HTS P

+13.65 1.77 38 80 09/91 is ID (general)-

5/N 0.20.His-S 14 % TW 0.48 Av83 39 30 09/91 Boe du VtAR.

S/N 1.21 HIS P

+16,21 09/91 B08 ID (general) 39 34 09/91 000 ID (General)

$/N.

5.48 HTS P

+ 8.46 09/91 808 10 (generat)

S/N 2.11 HIS P-

+17.81 09/91 15 ID (general)

S/N 0.32 His S

- 3.22 09/91 15-1D (general)

S/N 0.32 HTS-S

+ 3.26 09/91 15

.10 (general)

$'N-0.20 HIS S

- 3.26 09/91 iS 10-(general)- ' S/N

'O.35 His 8 3.30-09/91 15 10 (generat)

S/N 0.32 H15 5 3.30 09/91 15 ID-(general?

S/N 0,26 HTS S -

3.30

-09/91 IS ID (general)

S/N 0,32 HIS-S 3.22 3V 39 09/91 BOB ID (gene.al)

S/N 2.32 HIS P:

+ 9.83 l

Y

.,l

-#k,_--,,_,--.-_

m

            • Dutt 106 A h(1t-) ( v( a 3. 0 ) * * * * *
  • b da y' hove'iber 9, 1V'1?

09:09 A>4 ****** B AliCO" t a Wi t COx Co. * * * * *

  • P age 9

Ptont; 8+<Gulti UNif 1 Sicam Gerwr ato D Outagek:

09/91 br6 09/91 SLV 09/91 15 09/91 5!

kJfkv: AllAIhM kl 4 thDICAllDkt OF INN &f(Cilows kU.i (.0L 011 ALf INDICAllDN V A L UI VDt.15 LOCAllOh thCHf 5 3? 45 09/91 hou ID (generat) 65 % IW 4.38 HI$-P

+ 9.63 39 51 OV/91 hou OD wt t.R 1? % fw 0.38 Avn1 39 5? 09/91 hou 1D (Orner at )

5/N 7.19 N15 0

+13.60 39 66 09/91 BOH 00 WEAR 10 % T W 0.34 AVB1 3V 67 09/91 800 lb (general)

$/N 3.25 H15 0

+13.57 37 TO 09/91 15 ID (gener8L) 5/N 0.16 NTS-L 3.87 3V 75 09/91 106 lb (germral) 95 % TW 6.00 His P

+11.?9 39 64 09/91 BOB lb (generet>

68 % TW 3.6? H1$4 412.55 40 25 09/Y1 15 ID (gener at )

5/N 0.?4 Hit S

+ 0.74 40 30 09/91 It ID (gener nt )

t/N 0.?O H15 5

  • 0.08 09/91 15 10 (generat) t/N 0.16 H15-$

+ 0.04 07/V1 15 ID (general) 6/N 0.17 HTS S

  • 0.04 40 31 09/91 15 ID (general) 5/N 0.?S His L 0.63 09/%' 15 lb (gerwrat )

S/N 0.?O H15 5 9.7) 09/V1 15 ID (gercr at) 5/N 0.16 H15-5 0.71 09/V1 15 ID (general)

$/N 0.1? HTS 5

0. 75 40 3? 07/91 15 ID (gener al)

S/N 0.37 915 5 3.27 40 40 09/91 15 ID (gener al) 1/N 0.16 HI5 s

+ 0.24 09/91 15 ID (gener al )

5/N 0.16 HI$-5

+ 0.1?

40 61 09/91 Hou 10 (gener at )

65 % iw 6.86 N'5 P

+18.13 09/91 15 10 ( gene r al )

5/N

,,.39 Hl$-5 7.69 6?/91 15 1D (genert4 )

5/N 0.43 His 5

?.69 09/91 15 ID (g<;neral) 5/N 0.28 H15 5 2.73 07/V1 15 ID (general)

S/W 1.2d H1$ $

?. T3 Ov/V1 ts ID (general) 5/N 0.?D His L 2.77 09/91 15 ID (general) t/W 0.20 Nf5 $

?.77 07.'91 15 ID (generat) 5/W 0.?4 Nf5 5

?.77 09/91 TS 10 (general)

S/N 0.24 H15 $

?.77 09/91 It ID (general)

S/N 0.?4 His 5 2.77 40 $2 09/91 0L ID (general)

S/W 1,56 HIS P

+16.68 41 62 09/91 00H ID (gener al )

48 % 1W 5.05 H15 0

  • 17.44 4

4 40 66 DV/91 Roh OD WEAR 15 X TW 0.55 Av81 40 75 09/91 Holi ID (generat)

S t.4 3.40 015-0

  • 9.87 40 93 09/91 00H OD WLAR 13 % fW 0.47 Akhi 41 28 09/91 15 lb (general)

S/N 0.28 His 5 0.55 09/V1 1$

ID (q, nor al)

L/k 0.20 His S 0.55 09/91 15 10 (generat) 5/N 0.20 His s 0.55 41 5? 09/91 15 ID (general)

S/N 0.12 H15-5

+ 0.04 4

41 53 09/91 BOB ID (genernt)

S/W

?,56 H15 P

+15.29 41 70 09/91 0011 00 (genernt)

S/N 0.27 2 41 95 09/91 BOB 00 (gener at )

5/N 0.36 His-s

+ 0.68 42 25 09/91 B0li ID (general) 40 % 1W 5.99 His-P

+16.25 42 /0 09/91 15 ID (germr at s S/h 0.24 HIS-S

?.88 09/91 15 ID (general) 5/h 0.16 Hl$ $

?.9/

4? 76 09/91 koa Ou (genera.)

S/h 0.37 1

+ 0.08 43 46 09/91 000 00 W( AR 11 % 1W 0.37 Aval 43 60 09/91 B00 UD uf AR 12 % TV 0.42 AVbt 44 31 09/91 Bull ID (general) 5/N 4.46 Mts P

+18.13 09/V1 15 (D (general)

S/N 0.43.i* 5 3.12 09/v1 15 ID (geoeral) 5/N 0.43 HIS L 3.12

i. 4 37 09/91 006 ID (generat) s/h 7.54 Hit-P

+15.73

s. 4 49 09/91 DOB 00 W AR 14 % iW D.47 AVP1 53 09 91 006 00 WIAR 17 % TW 0.64 Av6' 4 l.

/

44 t6 09/91 808 OD WCAR 15 '4 T W 0.55 AVB1 44 71 09/9' 15 10 ( gener al )

5/N 0.?O His $

0.16 45 ?6 09/91 (106 ID (general) 65 V TW 1.51 HIE F

  • 11.26 45 30 09/91 15 ID (gener al) 5/h 0.16 MTS S
  • 0.16 45 34 09/V1 B00 00 W!A' 15 % TW 0.53 AvB1 45 43 09/91 800 00 VfAR 9 % TW 0.29 Av81 45 5? 09/91 G00 0D WEAR 15 % TW 0.53 Avn) 45 57 09/91 HOU 00 LT AR 75 % TW 1.08 AVB1 45 59 Ov/91 Lon 00 w' tR 30 % IW 1.42 Avat 4 '. 60 DW99 h0B OD WEAR 11 % TW 0.38 Aval 46 57 09/9n Bati 10 (generall 5/N 1.43 HIS S 0.57 09/91 1s 10 (generat)

S/N 0.?B HTS S 0.35 09/91 15 ID (general) 5/h 0.?O N15 5 0,35 OY/91 15 iD (generat) 5/N 0.?0 HIS s 0.39 l

i if

            • Dutt fuBAN(tm) (VIR. 3.0)****** Morday November

-9, 1992 09:10 AM * * * * *

  • BABCOCK & WI L Cox to. * * * * *
  • rage 10 Plant: 6cGulkt UNii 1 Steam Generatori D i

Gatoges:

09/91 898 09/91 SLv 09/91 t$

09/91 s1

' Can u Y : A11 ACH?ti4i JL INDICAflDNS Of IMP (R f f CIIDNS kDW COL DJ1 Att INDICAilDN VALUE VOllS LDCAllDN INCHES

. 09/91 15 10 (general)

$/N 0.?4 His S 0.39 46 78 09/91 BDB 0D WEAR 19 % 1W

?.10 AyB1 47 36 09/91 BDB 00 (general)

$/h 0.33 3

  • 0.02 4 7 4? 09/ 91 BDB ' 10 (general) 93 % IW 20.69 HTS P

+ 1.50 47 45 09/91 DDB ID (general)

S/N 3.55 HIS *

  • 13.54 09/91 800 1D (general)

$/N 3.44 HIS P

  • 10.62 47 46 09/91 BD0 00 (general)

S/N 1.70 20

+ 5.78 09/91 Si to (general) l '1 1.23 ?O

+ 5.08 47 $2 09/91 15 ID (general)

S/N 0.20 Hts-S 0.68 47. 78 09/91 BDB DD WEAR 15 % 1W 0.56 AVB1 09/91 B08 OD WCAR 1? % TW 0.41 AVB2 F

47 81 09/,1 GDB ID (genu 4)

S/N 1.17 HIS P

+ 4.41 48 30 09/91 is 10 (general)

$/N 0.16 HIS*$

+ 3.51 49 32 09/91 IS ID (general)

S/N J.20 His S

  • 0.08 49 33 09'91 15 _ ID (general)

$/N 0.24 his S

+ 0.17 49 38 09/91 BD0 OD WE AR -

?? % IW-1.21 16 49 6? 09/91 BDO 10 (general) 55 % IW 7.?4 His P

+14.28 49 68 09/91 BDB ID (general)

S/N 1.98 HIS P

+19.89 09/91 IS ID (general)

$/N 0.?4 NfS S 1,38 09/91 15 10 (general) b/N 0.20 HIS S 1.42 09/91 is ID (genecol)

$/N 0.12 HIS T 1.42 l

49 69 D9/91 000 0D (general)

$/N 0.46 17

+ 0.07 10fAl 100f5 fouND 350 625

'tofAL INDICAf!ONS FouND

=

t

?

11 i -

l 4

w.

m=--

m,,

            • Du[t 10 BAN (Ip) ( VI R. 3.0?* * * * *
  • Monday hovenber 9, 1992 09:14 AM ****** BAllCDCr & Wi t COM CC. * * * * *
  • Page i

l'tont s McGUlFt 0411 1 -

Ctc6.m Generator; A Out age s :

DV/ J1 RIO 09/91 Siv 09/91 15 09/91 5 OU(* f t AffACNMIbl (( TUEtt PLUGGID 08 RIPAlf(D RDW COL DUf AGt

-lGDICAll0N VALUt VollS LDCAllON lhCHt S

? 1 09/91 RfD StiL Vf D Design 3 HIS P

+11.00

? 35 09/91 af0 SLt[VfD Design 3 HIS P

+17.50

.2 54 09/91 klo PLUGGED MI. C H HIS P OV/i' RfD Pt VGCl O MLCH CTS-P 2 51 0V/91 RfD Stt tVf D Design 3 N15 P

  • 17.50 2 71 09/91 Rf D St t t VE D t-Ign 3 MtS P

+11.50 2 75 09/91 Rf D Si t i vt D Design 3 Hla P

+17.50 2 80 09/91 Rf D St t ivt D resign 3 HIS P

  • 17.50 2 87 09/01 RfD SittVLD Design 3 His P
  • 17.50 2 88 OV/91 RfD St t t Vt p Design 3 Mfs P

+17.50

? 104 09/91 RIO ati t Vf D Design 3 HIS P

+17.50 3 33 OV/91 RfD SittVf D Design 3 NTS P

+17.50 3 50 OV/91 RfC Sitivf D Design 3 His P

+17.50 3 86 09/91 Af D - SittVf D Design 3 -

H15 P

+17.50 3 89 09/91 klo Strivt0 Design 3 His P

+ 17.50 4 46 D9/91 Rf C Stt[VLD Dehlgn 3 HIS P

+11.$0 4 65 09/91 RfD Sti t VID Design 3 His P

+ 17. 50 4 7/ 09/91 RfD SitivtD Design 3 HIS P

+ 17. 50 4 Ph 09/91 RfD PluGGt D MECH HIS P 4 95 D9/91 RfD StilVf D Desi n 3

. CIS P 09/91 RfD PLUGCt 0 MICH D

- HIS*P

+17.50 4 96 04/91 RfD St t t Vt D Design 3 His P

+17.50 4 101 09/91 RfD StitVf D besign 3 HIS P

+17.50 4 105 09/91 kta St e r V! '

Design 3 H15-6

+ 17.50 5 -63 09/91 RfD Si t t VL D Design 3 Nfs P

+ 17. 50 5 75 09/91 Af D Sit tVf D Desi n 3 HIS P

+17.50 9

5 78 09/91 RfD PLUGGED MtCH His P 09/91 RfD PLUGGID MECH CIS P

$ 90 DY/91 RfD StitVLD -

Design 3 HIS P

+17.50 5 106 09/91 RfD FtVGCLD MI CH M1$ P

+

09/91 RIO PluGGtD MICH CIS P 5 112 09/91 RfD Sitt VfD -

Design 3 H1S P

+11.00 6 87 09/91 RfD Sittvt0 Design 3 HIS P

+ 17.50 7 54 09/91 Rf D SttivtD Design 3 HIS P

+17.50 7 78 09/91 Rf0 sit t Vf D Design 3 His P

+ 17 $D 7 BT 01/91 980 St t t Vt0 Design 3 His P

+ 17. 50 7 94 09/91 Rio-st((VCD Design 1 HIS P

+17.50 l

7 110 09/91 RfC SLIEVfD Design 3 HIS P

+17.50 8 20 09/91 RfD Sttt Vf D Design 3 HIS P

+17.50 8 83 09/91 RfD StitVED Design 3 His P

+17.50 9 29 09/91 RFO St t t VED Design 3 His P

+ 17. 50 9 B6 09/91 RfD StttVfD Design 3 HIS P

+17.50 9 88 09/91 RfD StitVt0

_ Design 3 HIS P

  • 17.50 9 92 09/91 Rf0 Sit t VED Design 3 His P

+17.50 9 97 09/91 Rf C Stt[VED Design 3 HIS P

+17.50 9 101 09/91 RfD-StitVCD Design 3 NfS P

+17.50 10 - 21 09/91 Rf C PluGGF D CCH NIS-P 09/91 RfD PLUGGED MECH CTS P

-- i 10 ~60 09/91 Rio SittVID

- Design 3 HIS P

+ 17. 50 10 - 68 09/91 Rf D St t t VED -

Design 3

- HIS P

- +17.50 10 70 09/91 RfD SittVt0 Design 3 HIS P

+17.50

'10 -76 09/91 RfC SitivtD Design 3-

- HIS4P

  • 17.50 10 83 09/91 Rfo StttVfD Design 3 hfS-P

+ 17.50 10 104 09/91 RfD StttVfD Design.*

HIS P

+ 17. 53 11 57 G7/' 1 RIO SLttVf D -

Design 3 NfS P

+17.50 11 61 09/91 RfD StttVfD Design 3 HIS P

  • 17.! ?

11'112 09/91 RfC SLEtVED Design 3 HfS-P

  • 11.00 12 59 09/91 RfD StttVfD DestDn 3 HIS P

+ 17,50

-.12-79 09/91-RfC. PLUGGED.

MECH N15 P 09/91 Rf0 (LUGGt1 Mf( n Cis-P 1? 105 09/91 RfD SttEVED Design'3 pts P

+17,50

-09/91 RfD PLUGGED MECH HIS-P 09/91 RfC PLUGGED MECH.

CIS P 13' ?5 09/91 Pf0 SittVCD Design 3

- HIS P

+17.50:

' 13.- 64 09/91 Rio St.EVED Design 3 His P

+ 1 ?.50 -

13 108 09/91 RfD stitVfD Design 3 HTS e.

+17.50 14 45 09/91-RfD StttVfD Design 3 His P

+17.50 E

9 j --

D g,,i..h -m.

w.--,-+,,,r-.,.._m_-r-'e w re-w-w-e-

-e-v-v----s-

-vc w

4-e--e-m=

re--e vw==e

- =

J'-

  • ' + -
            • Duit fUBAb(IM) (Vi t. 3.0)* * * * *
  • Manday W aventer 9, 199?

09:15 AM * * * * *

  • BahCDCE & WI L Con Co. * * * * *
  • Page 2

Plot's McGUIRE UWil 1 Steam Generatort A Dutoges:

D9/91 RfD 09/91 Siv 09/91 15 09/91 Si outRYt A11AtkMENT $ futatS PLUGGtD OR REPAIRtD

- ktW Cut DJ1 Act ikDICAflDN VAtut VOL15 iDCAffoN 14tkts

.. ~....

14 75 09/91 RIO Slf tvl0 Design 3 HIS P

+ 17.50 14 78 09/91 RfD St[tVf D Design 1 HIS P

+ 17. 50 14 97 09/91 #f0 St tiVED Design 3 HTS *P

+ 17. 50 14 105 09/91 Rf0 SittVtt Design 3 HTS P

  • 17.50 14 ill 09/91 Rf4 Sit'[Vt 0 Design 3 HIS P
  • 11.00 15 57 09/91 RfD Sitivt0 Design 3 HTS P
  • 17.50 15 6% 99/V1 RfC St t t VLD Design 3 HIS-P

+17.50 P e3 09/91 RfD StttbtD Design 3 H15 P

  • 17.50
6 ?? 09/91 RfD SitivtD Desiin 3 Mts-P

+17.s0 t

16 63 09/91 #10 PLL;6t0 MICH HIS P 09/91 RfD PluGGt D MECH C15 P 16 (4 09/91 Rf D SlitVf D Design 3 his-P

+17.50 16 70 09/91 RfD PLUGGt0 MECH HIL P 09/91 RfC PlVCGE D MECH CTS P 16 71 09/91 RfD Slt f Vt0 Design !

HIS P

  • 17.50 16 -76 09/91 RfD Sit t VE D Design 3 HIS-P

+17.50 16 63 09/91 RfD SLt t vib Design 3 HTS P

  • 17.% 0 16 85 DV/91 RfD St tt VE D Design 3 HIS P

+17.50 16 97 09/91 RfD Sit tVtD Design 3 NfS-P

+ 17.50 11 100 09/91 #fo SittVLD Design 3 HIS P

+17.50 16-60 09/91 RfD SLftVto DesiSa 3 uts P

  • 17.50 18 61 09/91 RfD SittVED Design 3 HIS P

+17,50 18 87 09/91 RIO Sit t Vf D Design 3 H15 o

+17.50

'9 58 09/91 RfD tit tVf D Design 3 HIS'e

+17.50 19 58 99/91 RfD Sti E VtD Design 3 Nts P

+17.50 59 84 09/91 RfD Sit [VED Design 3 HIS-P

+ 17.50

?0 89 09/91 Rio Sitt vf D Design 3 H15 P 17.50 21 64 09/91 RfD stitVED Design 3 HIS P

+ 17.50 71 72 09/91 RfC StttVtp Design 3

' HIS P

  • 17.50 21 75 09/91 RfD Stt[VED Design 3 HIS P

+17.50 21 8? 09/71 RIO Sttiv7D Design 3 HIS P

+17.50 22 54 09/91 RfC Sitt e;D Design 3 HIS P

+17.50 22 77 09/91 Nf0 StitVtD Design 3 HIS P-

+17.$0 73 65 09/91 RfD St((VLD Design 3 HIS P

+17.50 23 68 09/91 RfD Slits 2D Design 3 HIS P

+17.50 23 70 09/91 RIO SLLivlD C.' sign 3 MfS-P

+17.50 24 56 09/91 RfD P'.UGGI D MECH HTS P D9/91 RfC PluGGID MECH CTS P 24 57 09/V1 Rio SLttVt0

. Design 3.

HIS P

+17.50 24 61 09/91 RfD Si t E VE D -

Design 3 HIS P

+17.50 24 78 09/91 RfD PLUGGED MICH HIS P 09/91 RfD PLUGGfD MECH CIS P

?4 100 09/91 RfD ftttvtD Design 3 HTS P

+ 17.50 24 105 09/91 RfC Stt tVE D Design 3 H15-P -

+17.50 25 67 09/91 Rf D StttVLD Design 3 NTS P

+ 17.50 P6 60 09/91 RfD SLitVLD Desig.: 3

.Ht$ P

+17.50 26 -67 09/91 RfD PLUGGED MECH HIS*P 09/91 RfD PLUGGtD MECH Cis-P

?6 79 OV/91 RfC StitVED Design 3

-HIS P

  • 17.50 71 65 09/91 RfD SLitytD Design 3 H15+P

+ 17.50

??' 68 09/91 RfD SLttVtD Design 3 HIS P

+17.50 27 71 09/91 Rf C. PLUGGtD MICH N15 P-09/91 RIO PLUGGtD MLCH CIS P 77 75 09/91 RfD Sit t VtD Design 3 HIS-P

+17.50 27 - 76 09/91 RIO SLttVED Design 3 HIS P.

+ 17.50 il 77 09/91 RfD SLitVED Design 3 HIS P

+17.50 28 16 09f91 RfC St[t VtD Design 3 His P

+17.50 29 62 09/91 RfD StitVt0 Design 3 HIS P.

+17.50 29 04 09/91 RfD Slit VED.

Design 3 HIS P

+17.50

?V 66 09/91 RfD Stt[VLD Design 3 HIS P

  • 17.50.

29' 68 09/91 RIO Sit [VfD Design 3 HIS P.

+17.50 29 70 09/91 RfD Sit t Vf D

_Destis 3 HTS-P

+ 17.50 29 11 09/91 Ef0 Sit [VED Desif. 3 HIS+P e17.50

'?9 77 09/91 #fD SLitVtD Design 3 HTS P

+17.50-29_-78 09/91 Rf o-SLttVfD Design 3 HIS P

+17.50

?v 83 09/91 RIO StrtvtD Design 3 H15 P

+17,50 29 64 09/91 Rfo SittVED.

Design.3 HIS P

+17.50 f

-7

_ - ~ ~ -

..--o

~ -- - -

i

e 8

es***e Duit 1Uf;ARE1H) (via.. $.0)****** Manday Nnve44r 9, 199?

09:16 AM ****** BABCOCK & Wit Cox CO. * *** *

  • Page 3

Plantt McLutRt UNil 1 Steam Generator! A outagest.

09/91 RfD 09/91 SLV 09/91 15 09/91 SI puf.Rfi A11 AtHMt h15 f uels PlVGGlu 04 VIPAIR[p ROW CDt (U1 AGt INDICAtlDh VALUt V0tfS t(KA110N INC Hi s 79 104 09/91 Efo Si tivtD Design 3 H1=-P

  • 11.00 30 61 09/91 RfD Sittt t D Design 3 Nft P

+17 $U 4

30 68 09/91 RfC Stityt D Design 3 HiS-P

  • 17.50 30 71 09/91 Rf0 St t t VID Hemign 3 HIS>P

+17.50 30 T4 09/91 Rf D Stit ytD Design 3 HIS P

  • 17.50 30 17 09/91 hf0 Sitivl0 Design 3 Nfs P
  • 17.50

'30 78 09/99 RF0 PtVGGID MCCH NfS P 09/91 Rf D PL UGGE D MECH CIS-P 30 81 09/91 RfC StrfvtD Design 3 tit s P

+17.50 30 83 09/91 RfD StitvfD Design 3 HIS P

+17.50 31 72 09/91 Rio rtitVfD Design 3 HIS-P

  • 17.S3 31 79 09/91 RfC SitivtD Desigi 3 HIS P

+17.50 31 89 09/91 RfD StitVID Design 3 HfS P

+17.50 31 98 09,+91 Rf0 StitVID Design 3 HIS P

+17.50 31 99 09/91 RfD St !!vtD tesign 3 HTS +P

+17.50 3? 40 09/91 RfC PLUGGtD MICH HIS P 09/91 RfC PlVGLID MECH CIS P 3? 67 09/91 Rf D SitivtD Design 3 H15-P

+17.$0 3? 141 09/91 RfC St it yt D Design 3 HIS P

  • 11.00 33 42 09/91 RfD PL'JGGtD MCCH HIS P e

09/91 RfD PlOGGI D MICH CIS P 33 50 09/91 RfD Stit yt0 Design 3 HT3 P

  • 17.50
33. 52 09/91 Rio StitytD Design 3 NfS P e 17.50 31 50 09/91 i SittvtD Design 3 NfS4

+ 17.50 33 04 09/ 91 f St[t ytD Desige 3 NfS-P

+11.,00 34 46 09/91 Rr0 PldGGID Mf CH HIS P 09/91 RfD PLOGGED MtCH Cta P 34 67 09/91 RfD Sti f vtD Design 3 HIS P 417.50 34 B6 09/91 RfD St rivt 0 Design 3 HIS+P

+17.50 35 59 09/91 kf0 Stitvt0 Design 3 HIS+P

+ 17,! P 35 71 09/91 #fo PtVGGID MECH HIS P 09/91 #f0 PLUGGID MECH CIf*P 35 72 09/91 RfD PluGGID MICH HIS P 09/91 RfC PLUGGID MtCH C15 P 35 74 0?/91 RfD Sit t Vf D Design 3 HIS-P

+17.5J 35 D2 09/91 RfG' StttVID Design 3 HIS+P

+17.50 36 77 09/91 RfD Sitivt 0 Design 3 HTS P

+17.50 36.83 09/91 AfD SittVfD Dealgn 3 His P

+17.50 36 35 (29/91 RF0 Stt i vtb Design 3 HfS P

+17.50 37 - 69 09/91 Rf D StltutD Design 3-H15 P a17.50 33 78 09/91 RIO sitivtD Design 3 HIS P

+ 17.50 38 93 09/91 RfD SL C EVE D Destan 3 His P

+11,00 39 58 09/91 RIO Stit VID Design 3 HIS P

+ 17.5 0.

39.72 09/91 Rf' Stfivt0 Design 3 His P

+ 1/. 50 4C $4 09/91 RfC Sit tVf D Design 3 H1$+P

  • 17.50 40 81 09/91 Rf'O Si t [Vf D Design 3 HIS P

+17.53 41 85 09/91 RfD Strtvt0 Design 3 NtS+P

  • 17.50 4? 5$ 09/91 RfD PtuGGtD MECH

-ut$ P 42 80 09/91 RfD Stt tVID Design 3.

C15-P i

09/91 RfD PLUGCCD MICH HIS P

+17.50 43 80 09/91 RfD' Sittvt0

- Desien 3 His P

  • 17.50 -

45 44 09/S) RfD PtVGGtD MECH HTS P 09/91 RfD PluGGID MICH C15 P 49 66 09/91 RfC PLUGGt0 MECH HTS +P

'09/91 WF0 PLUGGED MECH CIS P 4V 67 09/90 RfC PLUGGtD MECH HIS P 09/91 RfD PLUGGED MECH CTS-P 49-68 09/91 R'3 PluGGtD Mf CH HIS P 09/91 RfD PLUGGt0 MtCH

-- C T S - P -

49 69 C9/91 RfD PtVGGtD MC CH '

HT$ P 09/91 RfD PLUGGED.

MICH CIS P

~49.70 09/91 RF0 PLUGGED Mt Ca HIS P 09/91 RfC PLUGGED MECH CIS P 49 71 09/91 RfD PtVGGED MECH Nff P 09/V1 RfD PLUGCCD

- MECH-CTS P

.i 49 73 05/91 RfD PLUGGtD PLCH HIS-P 09/91 RfD P!UGGED MECH CTS P 1014L 1UBCS f ouND

'5 372 201 10 fat INDirA110NS fouND

=

I

______...-m.

_____.-.__.___-m.

I e

n 4

  • *"" Dun [ IUg Aw(IM) (Vt R. 3.0)"**". Mwdsy Novecher -

9, i???

09:17 nt *** *" 8ABCOCK & WILCox Co. """ Page 4-

' Plant: McCaitt Utli 1

$ team Genera *or 8

[

- OAnges:

09/91 RfD (d/91 SlV 09/91 f$

09/91 tl r

O')t R V ! AII A(HMENI ( 106t $ PLUGGE D OR REPAlRE D f

RDW CD( (Ili AGr jkDICAllDN VALUf VOL i$ L OC A f l DN IWCHt$

.m.

? /6 09/91 RIO Sit tVtD Design 3 Hi$ P

  • 17.50 7'

37 D9/91 RfD SL t i VI.D Design 3 HIS P

+17.50

?. '.6 09/91 R f D $ttivtD Design 3 His P

  • 17.5 D r

? 63 09/91 RfD tttivt0 Design 3 Mts P

+ 17.50 3 97 09/91 a f o Pt WGt D MtCH Cis P 09/91 RfD PluGGt0 MECH HIS-f 4 15 09/91 RfD 5LitVfD Design 3 His P

+ 17. 50 l

~ 4 78 09/91 RfD $1((VfD Design 3 Mf5 P

+17.50 3

4 107 09/91 RfD $;t[Vl0 taasign 3 M15 P

+ 17. 50 fi 5 6 49/91 RfC &lttytD Design 3 His P

  • 17.50 5

7 09/91 RfD $litVLD Deutgn 3 HIS P

  • 17.50 6 35 09/91 hio 5tttVf D Design 3 HIS P
  • 17.50 6 37 09/91 RfD 5titVf D Design 3 His P

+17.50 6 4? C9/91 Rf D Sit tVf D Design 3 Hi$ P

+ 17.50 6 45 09/91 RfD SlitVLD Design 3 HI5 P

+17.50 6 53 D9/V1 RfD 5 Lit Vf D Desten 3 Hit P

  • 17.50 6 90 09/91 RfD tit [VED Design 3 His P
  • 17.50 7 9 01/71 RfD StitVtD Design 3 His P

+17.50

/ 78 09/91 RfD SL t[VL D Design 3 HIS P

  • 17.50 3

8 35 09/91 RfD 5 Lit Vt D Design 3 His P

+17.50 8 43 09/91 RfD. $titVt0 Denton 3 H10P

+ 17. 50

+

6 68 09/V1 Rio PLUGG!D MECH Ci$ P 09/91 RfD PLUGGtD MCCM HIS-P 8 69 OV/91 RfC PLUGGtD MECH Cis P 09/91 df0 PLUGGED WCH HI5 '

'.50 9 67 09/91 RfD StitVf D Design 1 Hf$-P 10 37 09/91 kf0 Pi U%CD MrCH Cis P 09/V1 RfD PLUGGID MICH MfS*P 10 64 09/91 RfD 5t E [V10 Design 3 HIS P

  • 17.50

'10 65 09/91 Rf D SitiVCD Design 3 HIS P

  • 17.50 11 61 09/91 RfD StitVfD Design 3 His P
  • 17.50 11 79 09/91 ~f0 si t t vt D Design 3 NfS P

+17.50

-11.BV 09/91 RfD Sttt Vf D Design 3 Mis P

  • 17.50 11 99 09/91 RfD SitiVf D Design 3 HIS P-

+17.50 12 74 09/91 RfD Sti tVID Design 3 Hf$ P

+17.50 12 78 09/91 RfD SLL5Vt0 Design 3 HIS P

  • 17.50 13 82 09/91 RfD SL E t Vf D Design 3 HIS P
  • 17.50 14 28 09/91 RfD Slt t VtD Desi.gn 3 M15 P

+17.50 14 16 09/91 Rio stitVID' Design 3 H1$ P

+17.50 14 _65 09/91 RTL Si t tVE D.

Design 3 Hi$-P.

+17.50 14 73 09/91 RfD PLUGGtD MECH Ci$ P 09/91 RfD PLUGG"O MICH HIS P m18 9 09/91 RfD PLUGGiD-MICH CIS P 09/91 Rfo PLUGGtD '

M; CH HIS P 18 10 D9/V1 RfD Slit V10 Design 3 Hit P

  • 17.50 18 83 09/91 RIO SitEVED Design 3 Kis P 417.50 20 6,09/91 RfD SLitVfD Design 3 HTS P
  • 11.00 20' 14 09/91 RfD PLUGGID MECH Cf 51 09/91 klo PLUGGED MfCH HIS P 20 35 09/91 Rio 5LitWo

-De$lgn 3 HIS P

+17.50 20 39 09/91 RfD stif Vtp Design 3 His P

+17.50

. ?D 10? 09/91 Rf D. StitVLD Desvon 1 HIS P

+ 17. 50 21 56 09/01 RfD SLitVE D Design 3 Hi$-P

+17.50

?? 1? 09/71 RfD 5 tit Vf D Design 3 HIS P

  • 17.50

?? 63 09/91 RfD St tt Vf D Design 3 HIS P

  • 17.50

?? 12 07/91 RfD SL t[Vf D Design 3 HIS P

+ 17.50

?) ?! 09/91 Rf0 PLUGGED dtCH

  • ,f U9/91 Rf0 PLUGGt0 MICH-HIS P

?3 37 04/91 RfQ Sitt Vt p

_ Design 3 His P

+ 17.50 23 61 09/91 RfD StttVfD

. Design 3 His P O

  • 53 25 68 09/91 RF0 mit tVfD Design 3 HIS P
  • .. 50

?$ L82 P/91 R!O EL12tvi n Design 3-His P

+17.51

?4 18 09/91 Cfo $tittsu Design 3 MI54P

+17.50

- 24 23 09/91 RIO PtVGGID

-MtCH C15 P 09/91 RfD UGGt D MLCH HIS P 24 43 09/91 Rf o ' siti VID Design 3 Hi$ P

  • 17.50

' ?4 f.6 09/91 Rfo StitVfD Design 3 n:'s P-417.50 2

l

= - + - '

a-

.s.

.,,.,_,__.._,a_._c_.-

..- - ~ - - - - - -. - -. ~ - - ~ ~ ~ _ - - - - -. - - -. ~ -

- ~. _

, 'e s * *

  • Dutt ' TUBAW(1M) (VE R. 3 ?)'* * * *
  • M(xday Noventer 9, 1792 D9:18 A4 ****** BABCDCE & VitCOE CO, ****** Page 2

Plant McGUlkt bkli 1 Steam Generator: B Outages:

D9/91 AfD 0//91 SLV 09/91 is 09/91 St OutRf: AllAtuMEW1 6. 10BES PLUGGED OR sfhAIRLD kDW COL OUf AGE thDICAtlDN VALUt VolI5 LDCAT.lDN INCHts 24--68 09/91 kf0 PLUGGt0 MECH Cis P D9/91 RfD PLUGGtD MECH -

H15-P l

?5 38 09/91 RfD StitVtD Desigo 3 HIS P

+17.50 t

26 21 09/91 RfD StttvtD Design 3 HIS-P 17.50 26 22 09/91 15 - DBSTRUC1tD 610 MILS His S 26 49 09/91 Rf 0 SLEEVf D Design 3 His P

+ 17. 50 26 53 09/91 RfD StttVCD Design 3 HIS P

+ 17.50 26' 62 09/91 Nfo stitvtD Design 3 His P

+17.$0 27 43 09/91 RfD SittVED Design 3 HIS P

+17.50 27 14 09/91 RfD PLUGGED MECr CTS P v

09/91 #fD PlVGGED MECH His P 28 15 07/91 RfD Sit t vt0 Design 3 HIS P

+17.50 28 68 09/91 RIO SLIEVID Design 3 HIS P

+ 17.50 18 -71 09/91 RIO StttVt0 Design 3 HTS-P

+17.$0 29 57 09/91 kr0 SLttVfD -

Design 3 HIS P

+17.50 29 63 09/91 RfD Sitt VCD Design 3 His P

+;7.$0 30 57 09/91 RfD Sit [V' D Design 3 HIS P

+17.50 30 61 09/91 RfD PLUGGIO MECH CTS P 09/91 RfD PtVGGtD MECH HIS P 31 13 09/91 RIO StttVED Design 1 His-P

+11.00 31' 15 OV/91 RfD Stt t VID Desi n 3 HIS P

'17.5C s

.31-In 09/91 RIO PLUGGID MECH CTS P 09/91 RIO Fil1GG10 MECH HIS P 11 69 09/91 RIO 5tttVED Design 3 His P

+17.50 31 79 09/91 RIO Stif Vf D Design 3 HIS-P

+17.50 32 21 09/91 RIO PLUGGt0 MICH CIS P 09/91 Rio PLUGGED MECH HIS P 32 53 09/91 Rf0 PtuGGtD MECH CTS P 09/91 RIO PLUGGCD MECH HIS+P 32 68 09/91 RfD SLEEvt0 9esign 3 His P

+17.50 35-10 09/V1 Pf0 SLitVf D Design 3 His P

+17.50 33 75 09/91 Pio PLUGGED dtCH CIS*P i

09/91 Rf D PLUGGtD.

MICH Nfs P 34 15 09/91 RIO - PLUGGED MECH CTS P 09/91 RfC PLUGGtD MECH 34 55 09/91 #fo sittVtG Design 3.

HIS P HIS-P

+17.50 35 4 7 07/91 RfD f t EtV+:0 Design 3 HIS P

+ 17. 50

'35 54 09/91 AfD Sti t tTD desita 3 His P

+17.50 37 49 09/91 Liv-stitVt0 Design 3 M15 P

+ 17.50 38 44 09/91 Af0 !s t t VID Design 3 HIS P

+ 17.50

33. 98 09/91 #f0 SLitVt0 Design 3 HIS-P

+11.00 39 19 09/91 R!O sitiVED Design 3 HTC P

+11,00 39- ?1 09/91 Rf C SLitVED Design 3 HIS P

+11.00 39 76.09/91 RfD PLUGGEC MICH CIS P 09/91 RfD PLULGtD MECH HIS P 40 31 D9/91 RfG Sit L~vt 0 Design 3 HIS P

+17.50

. 40 34 09/91 RfD PLUGGCD MCH CTS P 04/91 RfD PL UGGE D M.CH His P 41.-22 09/91 kf0 SLtivtr Design 3 His-P

+11.00 41 25 09/91 RfD SLEE VED Design 3

.:liS P

+ 17. 50 41 27 09/91 RfC SLEEVED Design 3 HIS P

+17.50 41 ' 4 7 09/91 R f D SLEtVfD Design 3 HIS P

+17.50 41 61 09/9. RfD $tttVED Ds.+ign 3 HIS-P

+17.50 41 85 09/91 Efo SLEEVt0 Design 3

-HIS P

+ 17.50 41 87 09/91 RF0 SLitVfD Design 3 HIS-P

+11.00 42 35 09/91 RIO SLEFvtD Design 1

- HIS P

+17.50 42 73 09/91 RfD Pt.UGGED MECH C15-P 09/91 R?b PtuGGtD MECH HIS-P 43 34 09/91 Rio StitVfD Design 3

- 43 35.09/91 #f0 FLttVLD Design 3

. HIS P

- + 17.!0 HIS P

+ 17.50 43 36 09/91 RfD StttVfD Design 3 viS r

+17.50 44 28 09/91 Rf 0 ' SLitVED Design 3 HIS P -

+1r.50 44 33 09/91 Rio SLttytD Design 3 HTS P

+17.50 i

L 44 60 09/91 Rio SLitVtD

- Design 3 -

HIS P

+17.50

' 44 65 09/91 RIO St tt VED Dasign 3 HIS P

+17.50 45 61 09/91 RfC Stt E VID -

Design 3

- HIS P

+17.50 4

45.53 07/91 RfD SLttVED Design 3 HiS P

+11.00 m

a y

w y-'

-wyy mp%-y-o'y -9g a

We, 1-r 9w.e 33-v%'

w yy,-p

,,79_,

7.-g.y..w.g,af p_g.

.w.,y.o,_

g qpf q_ gat a

--.._.._.~,...-..._m

..-~m.._-...__.-

__._---_m.m._.-.-

.~~.m.m._.__..__-.....

i t

BABCOCK & Wit tor Co. '"*" Page 3.

i e s e n e but t.

Tubak(IM) (VE R. 3.0)* * * * " N(wviay hoventw.c 9, 1992_

09:18 AM '****

Piant; McGUtPI UNil 1 Steam Gener ator 8 0;taget,t 07/91 pro 09'9i StV 07/91 1$

09/v1 51 r/Jt t f i At1 ACHMt h! 610 BIS PtDGGIO OR kiPAIRED f

WOW COL NTAGE.

IkDlCAfl0N VALUf VDLIS LOCAllON INCHf5

......... ~....,............+...

46 33 09/91 #FO PLUGCfJ MfCM CfS P t

09/91 PfD PLUGCED MICH Ht$-P Ao % 09/91 Rf D PLUGGt0 M( CN Cl $. e*

09/91 Rfo PluGCtD MfLH N15 P 47 B4 Oe/V1 RfD $4 f t Vf D Design 3 HIS P

  • 11.00 49 78 09/91 klo st t E vt 0 Design 3 HTS P

+11.00

-l 701 AL 1"ItES TCafkD s

118

'Of At ikJICA110NS f(RJND

=

140 1

i a

D l

5 t

-t

b i

~

^ ~ ~

3

};.

. 4 C..a 4

--,,e-,

.-..L-~.-.am.<.

,_...a.

.,_-..-,.._a--._,

,..-m.-,

. ~,..,.-,-J,%-

~ ~ ~ -.. - _ - _ -,

- -.- ~ -., -

. ~ - -. ~. ~ ~. ~ - - ~

- - ~. -~

-s.

e e+

s e b

i.

            • DU([ IUBAN(1H) (Vt R. ' 3.0)* * * * *
  • Monday hovemdser - _ 9, 19/2 09:19 AM ****** BABCDCK & Wilf01 CO. ****** Page 1.

Plant! McGylNL UNil 1

$1 nam Gene'atort C Outages 09/91 bD9 09/91 ilV D9/91 IS 09/91 $1 7Jtf f! All ACHMtN1 7 IU8t1 PtDGGtD (W REPAIRED kOW 001 001 AGE INDirAflDN VALUf Vol f 5 t(KA110N thCHF$

2 94 09/91 60u 5t t ivtD Design 3 His P

+17.50 2 95 09/91 800 $li[VCD Design 3 His P

+17.50 2 105 09/59 B00 StitVLD Design 3 HIS P

+'.50 2 108 09/91 800 StitVf D Design 3 Hit-P

+17.50 i

2 109 09/91 000 $t t t Vt D Desigo 5 HIS P

+ 17 50 2 111 09/91 000 Siti vt 0 Design 3 Hlf P

  • 17.50 i

3 64 09/91 DDP. $tti vt D Design 3 His P

  • 17.50 i

3 102 D9/91 000 illE VED Design 3 His-P

  • 17.$0

- i 3 106 (?9/91 608 5tf LVED Design 3 His P

+ 17. 50 4 /1 09/91 000 Sit tVf D Design 3 Nfs P

+17 $0 4 77 09/91 B00 StilitD De$lJn 3 His P

+ 17.50 4 81 09/91 800 St t t VJD Design 3 Hib P

+17.50 4 t) 09/01 000 Sti L VE D Design 3 His P

+17.50

?

6 101 09/91 000 5ttLVLD Design 3 His-P

+17.$0 4 105 09/91 Sr1 $Llt Vf D Design 3 HTS P

+ 17 $0

$ 63 09/91 800 Sit [VCD Design 3 NfS P

  • 17.50 5 68 09/91 Boe St[L Vt p Desten 3 His-P

+17.$0 5 75 09/91 000 $t t[Vf D Design 3 n!s P

  • 17.50 5 78 09/91 BDB St t[Vf D Design 3 HTS P
  • i7.50 5 80 09/91 80i $Li t Vf D vesign 5 HIS-P

+17.50 5 95 09/91 000 $t it Vf D Design 3 ufs P

+17.50 5 101 09/91 000 htt[Vf D Design 3 mig P

+17.50 5 101 09/91 Bon $tt[Vf D Design 3 n15 P

+17.50 6 95 09/91 pou tt t [ VI D Design 3 His P

  • 17.50 6 95 09/v1 B00 $t tt Vf D Desigo 3 H15 P

+ 17. s 0 i

/ 106 09/91 hou $t t t Vf D Design 3 His P

  • 17.50 7 113 09/91 008 st[tVED Design 3 His P

+ '.1. 00 8 72 D9/91 800 $t((VE D Design 3 Mit P

+17.50 8 98 09/91 B08 Stit Vf D Declan 3 His P

+ 17. 50 l

6 109 09/91 000 SLt[VED Design 3 His P

+17.50 9 71 09/91 000- StttVED Design 3 HIS P

  • 17.50 10 !$ 09/91 000 tit [Vf D Design 3 His r

+17.50 10 86 09/91 hoo sit t VtD

. Design 3 His P

+11.50 11 $1 09/91 008 St it Vf D.

Design 3 His P

+ 17. 50 11 80 09/91 608 StitVED Detion 3 His P

+17,50 11 B2 09/91 000 PLUGGtD MECH HiS+P 09/91 ' ' PLUuGt D MICH C1S P 11 98 09/7' Sl t t VED Design 3 H15+P.

+ 17.50 11 l'*

65f t Vtt Design 3 HIS P

+#1.00 t

12 e

.a J

/LUGGt0 HtCH Nf5 P i

i<

-T ' PLUGCCD HICH -

CTS P 1? /'

? t

$t tE VID DesiDn 3 HIS-P 917.$0 12: i-stit VE D Design 3 HI5-P

  • 1/. $f 11.78t<

Al StitVfD Design 3 His P

+ 17.50 13 111 04/91 800 sttivt0 Design 3 His P

  • 11.00 14 97 09/91 000 PLUGGED MECH N15 P 09/91 800 PLUGGFD MICH Cl$-P 15 102 09/91 BOS StitVED Design 3 Nfs-P

+17.50 16 35 09/91 808-5tttVED Design 1 His P

  • 17.50 16 44 09/91 808 StilVLD Design 2 His P
  • 17.50 16 50 09/v1 BOB -StitVED.

Design 3-H15eP

+17.50 1/ 54 39/91 BOB Stilvf D Design 3 His a

+17.50.

18 58 09/91 BDB 18 71 09/91 90A - Stt t Vt D Design 3 mis v -

+17.50 st t i vt D Design 3 HIS P

+ 17,50 18 75 09/91 800 Sit [Vf D Design 3

.Hi$-P

+17.50

-18 00 09/91 900 - PLUGGED MCCH HIS P m09/91 800 PLJGGt0 MICH CIS+P 18 81 09/91 800 $tttVtD

. Design 3_

=His P.

  • 17.$0 -

18 BS 09/91 000 St t t Vf D Design 3' MIS P

  • 17.50
i

, 18 89 09/91 000 Stt EVf D Design 3' HIS-P

+ 17. 50

19. 49 09/91 000 Slit VCJ Design 3 His-P

+ 17.50 19 68 09/91 B00' StitVCD Design 3 HIS-P

  • 17.50 19 78 09/91' BOB St((Vf D

'esign 3 HTS P

+17.50 1

19 90 09/91 000 SLt[VED i' sign 3-HIS+P

+ 17. 50 20 88 09/91 000 5LitVED

-algn 3 M15 P

+17.50 20- 89.09/91 Had SLt[VfD besign 3 HIS P

+ 17,50 20 94 09/91 oc$ st it ytD

-Design 3 His P

+17.50 e

w-

_,mmg**

Wmm s-mm--- * -w a

4-me-r'"avrew--

s**eN'ww-e*-9 m

L""*'-'*W "T#*#

I

-i.

' ; ll^b

~

s***** Dust !USAN(IM) (Vit. 3,0)* * * **

  • Nonday hoventer 9, 1V97 09:20 AM ****** 0^BC000 & WilC01 CD. ****** P80e 2

Plant McGUlpt UNII 1

$ team G?teeretor t C Dutagest U9/91 BOB 09/91 SLV 09/91 15 09/91 $1

~

Oul&V! A11 ACHMthf 7 TONIS PLUGGlD (A REPAltt0 ROJ LOL oufAGE i kplC A'i l 04 vat ut' VOLIS LOCAlltW 1hCHis 21 55 09/91 900 SLi t /ED Dess n 3 HI$ P

  • 17.50 e

21 64 09/91 RCs $ lit Vto D:$lgn 3 His P

  • 17.50 21 65 OV/91 BDD Siti vt D bestyn 4 HIS P
  • 17.50

?1 68 09/91 B00 $ tit VID Design 5 HIS P

  • 17.50 21 19 04/91 BDB $ltiVf D Design 3 Hit P
  • 17.50

?? 62 09/91 DOB St i tVf D Design 3 Hl$ P

  • 17.50 22 69 09/91 Bos $t t E VLD Design 3 His +
  • 17.50 24 30 09/91 808 PLUGGtD MICH HIS P 09/91 809 PLUGGt0 MLCH Cl$ P

?4 6? 09/91 608 Stit vtD Design 3 His P

  • 17.50 74 67 09/91 000 StitytD Design 3 H1$ P
  • 17.50 24 7/ 09/Vi BQ6 $ltE VtD Design 3 Nf5+P
  • 17.50 24 VV 09/91 ROG PLUGGt.0 MICH N15-P 09/91 006 PLUGGED MECH Cis P

?$ 53 09/91 BDa St tt W D Design 3 N11 P

  • 17.50

' ?$ 68 09/91 Boa $f.t L Vt D Design 3 H1$ P

  • 17.50

?$ 71 09/51 BOC Y ALWD Design 3 His P

  • 17.50 17 39 0'I/91 000 Si tr vtte Design 3 His P
  • 17.50

-27 42 D9/91 B00 SLf!Vt!

Design 3 HIS P

  • 17.50 27 44 D9/91 DDR SL E L Vtp Design 3 H15 P
  • 17.50 77 73 09/91 BOB SL t t VI D Design 3 HIS P
  • 17.50 27 104 09/91 BOB St EEVCD Cesign 3 HIS P
  • 11.00 27 106 09/91 B08 tLt E V!D Design 3 HIS-P
  • 11.00 28 61 uV/91 008 StttV D Design 3 HIS P
  • 17.50 28 79 09/91 EDO St t t Vl 0 De ;gn 3 HTS P
  • 1<.50 31 48 09/91 000 SL Et VL D De in 3 HIS P
  • 17.50 31 53 D9/91 non Stt t Vt D Dt

B 09/91 008 Sif f Vf D Desigo 3 Nis P

  • 17.$0 10f At 108ts f ouND 141 TOIAL lhDICAllDNS FOUND 160

=

?

l

}

l l

I I

s i

1

.f