ML20116L894

From kanterella
Jump to navigation Jump to search
Monthly Operating Repts for Oct 1992 for Byron Nuclear Power Station,Units 1 & 2
ML20116L894
Person / Time
Site: Byron  
Issue date: 10/31/1992
From: Ehle D, Pleniewicz R
COMMONWEALTH EDISON CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
BYRON-92-0718, BYRON-92-718, NUDOCS 9211190212
Download: ML20116L894 (14)


Text

n

'c T i -' j P

f

w W

/'

N

) Commonwrith Edison

/

Byron Nuckar Stttico (s O "7 4450 North Gerrnan Church Ro:d -

4 y'/ Byron,ilEnois 61010 l

1 November 13, 1992 L

1.

LTH:

BYRON 92-0718 TILE:

2.7.200 i

l Director, Office of Management Information and Program Control United Stak.es Nuclear Regulatory Commission Washington, D.C.

20555 ATIN:

Document Control Desk l-Gentlemen 1

Enclosed for your information is the Monthly Performance Report I

covering Byron Nuclear Power Station for the period October 1 through October 31, 1992.

Sincerely, i

l

-j

[

/

?.4 Q:~(h- : AMm,,__, -7,$

o R.

Plenlewicz

/'

Station Manager i.

Byron Nuclear Power Sthlion l

RP/DE/ph l

l-cc:

A.B. Davis, NRC, Region III l

NRC Resident Inspector Byron Ill. Dept. of Nuclear Safety M. J. Wallace/E, D. Eenigenburg Nuclear Licensing Manager (i

Nuclear Fuel Services, PWR Plant Support D. R.

Eggott, Stat, ion Nuclear'Engineerino INPO Records Center-J. R. Hickman - USNRC F. Yost - Utility Data Instituto, Inc.

p E

.t90-8

-im

  1. g (h o m a,vS>

yyuggam8jk m

n. ;i.

- 1

..t u,

.?

!! ' f; 4-

~

4-IF -

1

p-

.,4.i

    • y;

- i e

I w

IlYRCH NUCLEAR POWER STATION.

~ > >

UNIT.1 AND UNIT 2 s

MCNTHLY PERFORMANCE REPORT I

r-CObNCINEALTH EDISON COMPANY..

P

' \\;.i e

NRC DOCKET NO. 050-454 4

NRC DOCKET NO.' 050-455

~

LICENSE NO. HPF d i.-

LICENSE N -e:

t._

i +

.M I

4

's s

5 4

1 1-1 1

1 8

6 h

a

-r Lf T

7

?'

Q q,

i 1

0

.(3767M/VS/1):

.x

*'I

.' Is.

3 j,

s

[:

, m ;,

.i.

s u

....., ~.

p.

f A,,,

~

,4-;te

...4.-..g t-

,g- - ' -. - r g,

.3.

MdnLhly ftegortfor ByIgn.,1MIT 111or the manth of October 1992~

2.E <

.i Ai_Sgamary oL000ratinglgpgrlence_fRI_llait 1 ~.

.The Unit began: tl.is reporting period 'in' Hode 1 (Power' Operations)- lThe

~

. power' level varied due-to load following requirements.

4 4

P R

d

. h

' -i r

c f

y.

u e

.. s

. ~~ \\.

i e

as a

3 P

r

. )

+

4 y

0 4

l' f t>

s 5

h t

l..

Ii l\\

a-g i

i r -

.l( 3767M/vs/ 2 )

S

. } d '.

r

..p l F:.

~

  • i r

e

\\

s. 'f.l 1

L nu_QEEBAURE_DAIAJEEQRI DOCKET NO.

050-454 UNITt Byron One DATT:

11/13/92 COMFILED BY:

D.

Ehle TELEPHONE:

(815)234~5441' x2263 OPERATING STATUS 1.

Reporting Periods October, 1992.

Gross Hourst, 746 2.

Cu.~tently Authorized Power Level 3411 (MWt)

Design Electrical Rating: 1175 (HWo-gross)

Design Electricol Rating: 1120 (MWe.. net)

Har Depeadable Capacity: 1105 (MWo-not)

'f 3.

Power Level '.o Which Restricted (If Any): lione 4.

14easons '.or Restriction (If Anf): N/A THIS MONTH YR TO DATE CUMULATIVE *-

5.

Report Period Mrs.

745 7320 62,473 6.

Rx Critical Hours 745 7267.4 52,194.3 7.

Rx Reserve Shutdown Hours 0

0 38 w

8.

Hours Generator on Line-745 7259.1 51,563 9.

Unit Reserve Shutdo.<n Fours 0

0 0

  • 10. Gross Thermal Energy (HWH) 2,420,043 22,987,336 155,790,916
11. Gross Elec. Energy (HWH) 820,089 7,760,903 52,534,152
12. Het Elec. Energy 'MWH) 796,035 7,466.315 49,685,812
13. Reactor Service Factor 100 99.28

'83.55

14. Reactor Availability Factor 100 99.28 83.61
15. Unit Servite Factor 100 99.17 82.54
16. Unit Avallability Factcr 100 99.17 82.54 17 Unit Capacity Factor (MDC neti 96.70 92.31 71.97
18. Unit Capacity Factor (DER net) 95.40 91.07 71.01'
19. Unit Forced Outage hrs.

0 60.9

1,403.4
20. Unit Forced Outage Rata 0

.33 2.65

21. Chutdowns Scheduled Over Next 6 Months: Refueling Ort.sge BIR05 2/5/93.
22. If Shutdown at End cf Report Period, Estimated Date of Startup:

4/10/93

23. Units in Test Status (Prior to Commarcial Operation): None
  • Note - The curaulative numbers do not reflect power generated prior to comercial se:vice.

I

( 37 07M/VS /'3 )

)

lW ? [ '~

^

7:

,L qt Wy$ '.

?': "

C1._.hBhhGE D%.1LLITRlL. POWER LEVEL

' DOCKET NO. - 050-454;

,i UNIT:. Byron ~One-l DATER _J11/13/92l j

- CCHPILED BYt D.'fhle

~

_78LEPHCHE: -(01!)?34-5441 l

I x22f3-

- MONTH: October, 1992 i

(j

\\

DAY AVERAGE DAILY POWER LEVEL

~

(MWo. Net) 16.

_ _,.jf3 0._BW 1.

1Q99 MW i

2.

1031 MW

17. __ ___.._ _.ll3J MW

]

3.

_ 12AL.HW 14.

10lRJJ!i.

.1

-q

- 4.

._100LHW -

19. _

.._110LHtt 5.

1011.1DL __

20. -

110 SJfd.__ _._. ____

j 6.

_. 19?.JLMN 21, 10S$li..-

7.

lou.Ew

22. __ _ _

1054 HW l

8.

1074 MW 23.

_107 8 H)L -

9.

__1092 MW 24, 10.58 MW l

10.-

101Llat.,_

25.

'980 MW l

l 11.

1018 Ed _

26. _

103.) fMW

12. _

101,2 MW 27, 1103.MW 13.

- 1979 MW 26 <

.,_1993 MW:

j. :'
14.-

1065 MW 2 9.-

1 Rag _)(N.

I 15.

1071 F 30.

1102_MW'-

31. _,. _ _.

1079 MW

.- x INSTRUCTIONS

- On this form. list the' average. daily unit power level in MWe 4et'for each dayJ in the reparting month. Compute to the nearest whole meomiett. _.These' figures.

i-will be used te plot a graph tor,each reporting month. Netti that..when muximum -

- dependable capacity -is used _ for the net' electrical' rating. of the unit there may be-occasions when the' daily averago power level exceeds the 100V 11re=

(or-the_ restricted power Invel line.). In such cases the ' average' daily -tmiti power output aheet should be footnoted to explain the apparent anomaly,

[)

(3767H/VS/4)-

I-e k

) i.'

y yp_ a m

f

'm:

9

                                        • a***2, Report-Period October,-1992 UNIT SHUTDOWNS /REDUt~IIOFS BYRCN (UNIT 1)

._E0u Pfv e Iypt. Hourn Reason Metheri _LER Number System Camp _onent Caugg & Corrective Action to Prevent Regerrengg...

No Shutdown or Major Reductions in October

    • e******ce****:

Smratary.

.*eswt***A***A*e TIPE Reasnn liethod System & Cocmoment

'l M-anual Exhibit F & H F-Forced

'A-Equip Failure' F-Admiu

$~Sched B-Maint or Test: G-Oper Error

. 2-Manual Scram Instructions for

.C-Refueling.

- H-Other 3-Auto Scram Preparation of D-Regulatory Restriction 4-Continued Data Entry Sheet E-Operator Training 5-Reduced Load Licensee Event Report

& License Examination 9-7ther (LER) Fils (NUCEG-01f:1)

' t

'T e

1f3767M/vs/5)'

' i T

4

'-d m

- -.. e

+

. l 8,

.a ;

^

^ ^'

d<.

31_

UNIOUE _ REPORTINLREQUIREMENTS iUHIT 11-for the month of' OCTOBEIL]JLQ2 :

E.

1.

Safety / Relief valvti operations for-: Unit One.

V ALVES -

NO & TYPE PLANT-

DESCRIPTION DATE ACW ATED ACW AllDH C.ONDITION

-QF EVENT None 1,

L z-2.

Licensee generated changes to ODCM.

NONE 3.

Indications of failed fuel.-

fuel Reliability Indicatort Yes TRIT 1.3K-3'pci/cc 4.

10CFR50.46 Reporting Requirements:

Peak Clad temperature (PCT). changes resulting irom change-or-errors to_the ECCS evaluation model.!

o Current licensing basis. PCT plus raargin' allocation (?F)

=

Larse_ bit.at LOCA.

.Sanll_BI.e.nL 10CA 2 0 51.~ 3 -

'1510.1 Explaln :dif ferences f rom. previous _ report:

[

done 4

r p

V ':

l '.

l.-

i; ho I

f l-4

/

[

.-(3767M/vs/6) vs

7 v.

!F.

LICEl{5II_EY.Elft._REEORTS (UN T 'li

' -Thetfollowingfis a tabular summary.~of all Licensee Event Reports for.

l

~

1 Byron Nuclear Power Stationi Unit' One, submitted-during the: reporting period, October I through October.31, 1992. This information is-provided pursuant to -

'the. reportable occurrence reporting requirements as set.forth in 10CFR 50.73.,.

3 Occurrence L.1.cens2.0. Event _. RAP 2Lt Number RgLtg 11];11MAsurIARCA.

454: 92-008 10 01-92 Incomplete - Auxiliary submitted Feedwater Surveillance 10-26-92 Testing Discovered During

.l Review of Surveillance Program i

k 4

?

k i

r g

+

t

,a W

k i

f1 (3767M/VS/7).

/

1

~.,..

re r

g

4y

. p.,

.+

e c

s~

+

II. Eqnthly Report _1gyJy.EOlLifEIT 2 for toe m2 rah _QLQG'Ohb11992 Stancy. of O EIAting_EXPEIlance_[pr Unit 2 A.

P The_ Unit. began this reporting. period-in Mode 1 (Power Operations).

i

. The power level varied due to' 1 cad following requirernents.

l j

i t1 I

-l

-1 s:

.a i

i I

.- j l

q 1

' 1 1

(3767M/VS/8) d

.a ;. ;

+

4 4*~

a

- flu.QP.EEAIJEG DATA BIf0RI -

DOCKET FO.

050-455-UNIT t : Byron Two' DATE-11/13/92 COMPILED BY:

-D. Ehle TELEPHONE:

(815)234-5441 x2263' OPERATING STATUS l

1.

Reporting Periods October, 1992.

Gross Houtst 745 2.

Currently Authorized Power Leve11 3411 (MWt)

Design Electrical Rating: 1175 (MWe-gross)

Design Electrical Rating: 1120 (MWe-net)

Max Dependable Capacity: 1105 (MWe-net)

^

3.

Power Level to 5'hich Restricted (If Any):

/A 4.

Reasono for Restriction (If Any):

l' l:

L THIS MONTH YR TO DATE-CUMULATIVE

  • L 5.

Report Period Hrs.

745 7320 45,577 6.

Rx Critical Hours 745

-5637.5 38,871.6 7.

Rx Reserve Shutdown Houra 0

0 0

[

S.

Hours Generator on Line 745 5566.2 38,341.3=

9.

Unit Reserve Shutdown Hours 0

0-0

10. Gross Thermal Energy (MWH) 2,420,657 16,582,032 100,100,752 I'
11. Gross Elec. Energy (MWH) 834,998 5,6671177-36,623,946

'i

12. Net Elec.. Energy (MWH) 410,721 5,439,361-34,616,369:
13. Reactor Service Factor 100 77.02 85'.29
14. Reactor Availability Factor

'100 77.02 85.29-t.

L 15 = Unit Service Factor' 100

'76.04 84.12-L

16. Unit Availability Factor 100-

.76.04:

84.12

17. Unit Capacity Factor (MDC not) 98.48' 167.25 68.73
18. Unit Cepacity Factor (DER net) 97.16-66.35 67.81
19. Unit Forced Outage Hrs.

'O 88.1

-1244 0

. 20. Unit Forced Outage Rate 0

1.56 3.14 o

- 21. Shutdowns Scheduled Over Next-6 Months: NONE

22. If Shutdown at End of Report-Period, Estimated Date of Startup: NONE i
23. Units in Test Status (Prior to Commercial Operation): None
  • Note - The cumulative n mbers do not reflect power

' generated prior to commercial. service.

(3767M/VS/9)

=

y:

+

,e r

~

l w

.j 1

-y.

. CmAYERAGE RAILI. UNIT PONEJLLLVEL DOCKET NO.1-050.455 UNIT::=. Byron Two-DATE:'~./13/92' I

COMPILED BY1 D. Ehle-TELEPHONE:

(815)234-5441t x2263 o

NONTH: October, 1992 DAY AVERAGE DAILY POWER LEVEL (MWe-Net) 1.

111'1 MW _

16, 1122 MW 2.

1067 MW 17.

Ino MW 3.

1083 MW 18.

1091 MW 4

9.48 MW 19.

10]1 MW 5.

LQ18_)M_

20.

IL2.8 MN 6.

. LO53.Jf4 21.

1125 MW 7.

  • 057 MW 22, 1114 MW 1

8.

1117 MW 23, 1103 MW' E

9, lill MN

-24.

1080 MW 10.

1088 MW 25.

'977 MN-11, 922 MW 26.-

1096 MW 12.

'1081,MW 27.:

1129 MW 13.

110A MW 28.

1129 MW 14 1132 MW 2 9..

1130 MW 15.

H32 MW

30. _

_ __-1121 MW 31.

1208 M_W

. INSTRUCTIONS-

- '7n this form list the average daily unit power' level'in MWe-Net for each day

- -In the reporting month.. Compute to the nearest whole megawatt. These figures l

will be used to plot e *,raph for each reporting twnth.. Note that when maximum l.

dependable-capacity-is used'for the net electrical rating'0E the unit'there l

may'be occasions wh'an the. daily average power level exceeds the 100% line

[

. (or the restricted power 2evel line.)

In such cases the. average daily unit power output sheet should be footnoted'to explain the apparent anomaly.

(3767M/VS/10)

r

=

c t

4 Raport Period October,-1992 UNIT SEUTDOWNS/ REDUCTIONS BYRON (UNIT 2)

IY2n Bours Eraso$ Method LER Number System CQE22ngnt Cause L. Corrective Action to Prevent Recurrence-No..

Date No Shutdown or Major Reductions in October ee******+=*****

e Summary

~

eeee***2s******

TYPE Egagon Method System & Component

'F-Forded

.A-Equip'Fallare F-Admin 1-Manual Exhibit F & H S-Sched B-Maint or Test G-Oper Error 2-Manual Scram Instructions for C-Refueling ~

H-Othe r 3-Auto' Scram Preparation of D-Regulatory Restriction 4-Continued Data Entry Sheet E-Operator Training 5-Reduced Load Licensee Event Report

& License Eramination 9-Other (LER) File (NUREG-0161)

' { 37 67M/VS/11) '.

~

a

.e 9

E.~ UNIOUE REPORTING ' RECIMED(QiTS.. (UNIT 2 ) for the month _sf October 1992 j

1.-

Safety / Relief valve operations ~for Unit Two..

~

1 VALVES

'NO & TYPE

'JLANT :

1 DESCRIPTION.

o DAII ACTUAIED-

'AC2VATION CONDITIOt{.

OF EVENI.

j Mone 2.

Licensee generated changes to ODCM.

HONE 3.

Indications of failed fuel.

l No.

Fuel Reliability Indicator: TRI = 7.2E-5 pC1/CC

4. --10CFR50.46 Reporting Requirements: Peak Clad temperature (PCT) changes-resulting from changes or errors'to the ECCS evaluations model'.

Current licensing basis PCT plus major allocations ('F).

Large 3.reak LOCA SmalLJinaltLOCA 2064.1 1510.1' I

Explain differences from previous report:

None h

+

w r

4

-(3767M/VS/12) 9 m..

1

-a --

J

s

E.c c.,

~

dLICEtiSIE EVENT REPDRTS_ fUNIT 21

' The following is a tabular summary of a11' Licensee Event-Reports for s

Byron Nuclear Power Station, Unit Two, submitted during the' reporting period,y

- October 1, 1992.through October 31, 1992. This information is provided pursuant:

- to the - reportable occurrence reporting iequ) rements - as set forth -in '10CFR _50 '73.

LICERGle Event Report N.unther OccunentGtg Tlt1e of'Occurrangg' None C

S.

w b

i.

. s 1

l' l

' (3767M/VS/13).

i

.n_',

s m-e e+

e eI