Forwards Revs to Program Plan Which Addresses Issues Raised in Ltr Re RAI Re Byron Second 10-yr Inservice Insp Program.Responses & Questions Re 960613 Rai,Encl. Program Plan Should Be Reviewed on or Before 960822
ML20116L462
Person / Time
Site: Byron  
Issue date: 08/12/1996
From: Kofron K
COMMONWEALTH EDISON CO.
To:
NRC (Affiliation Not Assigned), NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20116L466 List:
References
BYRON-96-0222, BYRON-96-222, NUDOCS 9608190028
Download: ML20116L462 (7)


Text

Commonweahh ihn Company ll3 ron Generating Station 4 450 North German Church l<oad fly ron, 11.61010-9791 Tel Hl 5-23451 s l August 12, 1996 LTR:

BYRON-96-0222 FILE: 3.11.0321 Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, DC 20555 ATTENTION:

Document Control Desk

SUBJECT:

Second 10 Year Inservice Inspection Program Byron Nuclear Power Station, Ur' I and 2 Facility Operating Licenses NJ and NPF-66

,NRC Docket Nos. 50-454 and 50,.

REFERENCE:

(1)

Letter from George F. Dick, Jr. (NRC), to D.L.

Farrar (Comed) dated April 3, 1996, transmitting a Request For Additional Information (RAI) regarding the Byron Second 10 Year Inservice Inspection Program.

(2)

Letter from M. Lesniak (Comed) to Document Control Desk (NRC) dated February 23, 1996, transmitting the Byron Station Second 10 Year Inservice Inspection Program.

(3)

Letter from K.L. Kofron (Comed) to Document Control Desk (NRC) dated June 12, 1996, transmitting Byron Station Withdrawal of Relief Request I2R-11.

(4)

Letter from George F.

Dick, Jr. (NRC), to D.L. Farrar (Comed) dated June 13, 1996, transmitting a Request For Additional Information (RAI) regarding the Byron Second 10 Year Inservice Inspection Program.

(5)

Letter from R.A. Capra (NRC) to D.L. Farrar (Comed) dated March 14, 1995, transmitting SER approving Releif Request HR-1 and HR-2.

In Reference (1), NRC requested additional information regarding Relief Request I2R-11 submitted by Commonwealth Edison (Comed) Byron Station in Reference (2).

Comed withdrew this Relief Request in Reference (3).

Revision 1 of Relief Request 12R-11 is included in Attachment 2.

This revision addresses the issue raised in Reference (1).

In Reference (4), NRC requested additional information regarding various aspects of the Second 10 Year Inservice Inspection Program (Program Plan) submitted by Byron Station in Reference (2).

The answers to the specific questions raised in the RAI are contained in Attachment 1.

In conjunction with the responses to References (1) and (4), Comed has revised the Byron Station Units 1 & 2 Program Plan for the second 10 year interval. The attached Revision 1 pages are intended to replace the original, Revision 0 pages previously provided.

i

< }{]

{

r 9608190028 960812 PDR ADOCK 05000454 G

PDR A L'nicum Compan)-

p 1

i Byron Ltr: 96-0222 August 12, 1996 Page 2-I The revised pages of Sections 1.0 through 4.0 of the Program Plan are included in Attachment 2.

Revisions to Appendices C and F are included in Attachments 3 and 4, respectively. Changes to Appendices C and F have been made in response to Reference (4).

In addition, other editorial changes have been made to these Appendices for update purposes. All changes have been identified by a revision bar in the right-hand margin, as well as noting "Rev. 1" in the footer of the affected pages.

Comed requests that the Program Plan for Byron Unit 2 be reviewed on or after August 22, 1996. As of this date, the 1989 Edition of Section XI will be the " latest edition and adaenda of the Code incorporated by 7-reference in 10 CFR 50.55a one year prior to the start of the p

interval..."

This request is based on a commercial operation date for Byron Unit 2 of August 22, 1987. This issue was identified in Reference f

(2) Item 2.C.

s Although Comed currently has approval for use of code cases N-416-1 and N-498-1 until the Cases are incorporated into Regulatory Guide 1.147 (Reference 5), a relief request to employ these Cases for the Second Interval is included in this revision package, pursuant to Reference (2) Item 2.D.

In addition, relief requests to employ Code Cases N-509 and N-521 are included in Revision 1 of the Program Plan.

Please address any comments or questions regarding this matter to'Marcia Lesniak, Nuclear Licensing Administrator, 708-663-6484.

Sincerely, l

~

l K.L. Kofron Station Manager Byron Nuclear Power-Station KLK/GC/rp Atachments cc:

A.

B. Beach, NRC Regional Administrator, RIII G.

F. Dick, Jr.,

Byron Project nanager, NRR S.

Burgess, Senior Resident Inspector, Byron Office of Nuclear Safety, IDNS Michael T. Anderson, INEL (p:\\96byhn'960222.docW81296)

i ATTACHMENT 1 RAI QUESTIONS AND RESPONSES f

I A.

In Appendix C of the Program Plan, under notes, it is stated that credit for examination of Category B-T welds is being taken to accomplish the 25 percent i

snapling of Category B-J welds as allowed by section XI Interpretation XI 83-33, and that 21 Exnmination Category B-F welds are included in the i

Examination Category B-J population when calculating that 25 percent examination snapito.

The presence of dissimilar metal welds in both examination catejories can be confusing. However, the interpretation indicated is obsolete and not supported by the direction taken in later editions of the Code.

Starting in the 1989 Addenda, dissimilar metal welds associated with the reactor vessel, pressurizer, steam generators, and heat exchangers have been specified as Examination Category B-F welds. All other

\\

dissimilar metal welds are included in Examination Category B-J.

Using the inter codes as guidance, inclusion of B-F welds in the B-J snaple is not permissible.

Confirm that the progrna will be revised so that 25 percent of examination Category B-J welds are scheduled for examination without inclusion of B-F welds in the B'J snaple population.

RESPONSEr j

Based on the recommended NRC guidance on this issue, Comed has revised the

[

ISI Program Plan to ensure 25 percent of examination Category B-J welds are scheduled for examination without inclusion of B-F welds in the B-J sample population. The revised pages are included in Attachments 3 and 4.

The i

revisions are as follows:

1.

Appendix C, page C-3, Item M: Deleted Note 2.

2.

Appendix C, pages C-21 to C-23, C-58 to C-68, C-70 to C-75, C-78, and

)

C-80 to C-81:

Deleted Note 2.

3.

Appendix C, pages C-58, C-60, C-61, C-67, C-71, C-72, C-75, C-79, and C-81:

Added a total of 16 scheduled examinations to revise the sampling of Category B-J welds to 25%.

4.

Appendix F, page F-3, Item M Deleted Note 2.

5.

Appendix F, pages F-21 to F-23, F-58 to F-61, F-63 to F-67, F-71 to F-76, F-79 to F-81:

Deleted Note 2, 6.

Appendix F, pages F-58, F-60, F-65, F-67, F-71, F-72, F-75, F-79, and F-81:

Added a total of 17 scheduled examinations to revise the sampling of Category B-J welds to 25%.

i B.

Effective September 8, 1992, regulations were issued regarding the augmented examination of reactor vessels. As a result of these regulations, all licensees must augment their reactor vessel examinations by implementing once, as part of the inservice inspection interval in effect on September 8, 1992, the examination requirements for reactor vessel shell welds specified in Item B1.10 of Examination Category B-A.

In addition, all previously 1

1

[

granted relief for Item B1.10, Examination Category B-A, for the interval in effect on September 8, 1992, is revoked by the new regulation.

For licensees with fewer than 40 months remaining in the interval on the effective date,

)

deferral of the ' augmented examination is permissible with the conditions stated in the regulations.

l In the February 23, 1996 submittal, it is stated that the augmented reactor pressure vessel (RPV) examinations will be completed by the end of the first c

20-year interval.

Confirm that at least 90 percent of each RPV shell weld (Items B1.11 and B1.12) will be/has been exnmined during the first 10-year l

interval.

RESPONSE

All Category B-A, Item No. Bl.11 welds in Byron Unit I were examined during the recent ten year refueling outage. At least ninety percent (90%) coverage of each weld was achieved except for weld RPVC-WR29.

Relief Request I2R-01

]

includes a detailed discussion of the limitations associated with the volumetric examination of RPVC-29 (included in Attachment 2).

Similiar i

limitations are expected for the Byron Unit 2 examination of this weld, as discussed in I2R-01. The reactor vessels at Byron Station do not include i

Category B-A, Item No. Bl.12 welds.

C.

Inservice examination of components must comply with the requirements in the latest edition and addenda of the code incorporated by reference in 10 CFR 50.55a(b) on the date 12 months prior to the start of the 120 month interval.

In the February 23, 1996 submittal, it is stated that the Unit 2 Program Plan is being developed using the 1989 Edition of Section XI as a " baseline" in anticipation of a rule change in the regulations.

Considering the projected interval start date of August 22, 1997, for Unit 2, the Code-of-record can not be established and evaluation of the Unit 2 Program Plan is premature unless a specific exemption to the regulations to use the 1989 Edition is requested and justified.

In addition, based on the licensee's stated intent to use the 1989 Code as a ' baseline",

it is not clear how the Unit 2 Program Plan was prepared.

Provide clarification regarding the Code-of-record for Unit 2 during the second 10-year interval.

If the licensee's intent is to use the same code edition for both units, a specific request for authorization should be submitted in accordance with the regulations.

RESPONSEr Page 2 of the revised ISI Program Plan addresses this issue (Attachment 2).

As stated, the 1989 Edition of Section XI will be the " Code-of-record", based on a projected interval start date of August 22, 1997 and the current status of 10 CFR 50.55a rule making.

Comed requests that the Program Plan for Byron Unit 2 be reviewed on or after August 22, 1996.

As of this date, the 1989 Edition of Section XI will be the " latest edition and addenda of the Code incorporated by reference in 10 CFR 50.55a one year prior to the start of the interval..."

This request is based on a commercial operation date for Byron Unit 2 of August 22, 1987.

2

D.

Specific Code Cases may be used when approved for general use by incorporation into Regulatory Guide (RG) 1.247, Inservice Inspection Code Case Acceptability -- ABNE Section XI, Division 1, or if authorised by the NRC staff in accordance with 10 CFR 50.55a(s)(3).

The licensee's Program Plan references a number of Code Cases that have not yet been incorporated into the RG, but, as stated by the licensee, are expected to be contained in RG 1.147, Revision 12.

Use of these Code cases is not allowable without specific relief since conditions may be imposed by RG 1.147.

Therefore, to use these Code Cases during the second 10-year ZSZ interval, authorisation by the NRC staff is required.

Clarify the intent regarding the use of unapproved Code Cases and submit a request for authorisation for each applicable Code Case.

RESPONSEr At the time of submittal of the second interval Program Plan it was projected that code cases N-416-1, N-498-1, N-509 and N-521 would be incorporated into Regulatory Guide 1.147 prior to the implementation date. As noted on pages 4 and 5 of the revised ISI Program Plan (Attachment 2), Relief Requests I2R-15, I2R-16, I2R-17, and I2R-18 have now been included to request authorization to employ Code Cases N-416-1, N-498-1, N-509 and N-521, respectively, during the second 10-year ISI interval E.

In Appendix C.,

Table Description NDE method symbols used in the tables are o

defined.

Under visual examinations VT-1, VT-2, VT-3 and VZS are listed.

a "VIS" is defined as a visual augmented examination.

Nhat are the qualifications of the VZS inspection personnel? Provide a technical discussion describing the visual-inspection procedures used for augmented examinations and the qualifications of the inspectors.

If VZS inspectors are not certified or qualified to meet the requirements of VT-1, VT-2, or VT-3 examiners, provide justification for the relaxation in these requirements.

RESPONSE

Comed is revising appropriate Byron NDE procedures to employ a VT-3 certified examiner to perform the visual examinations of the Reactor Coolant Pump Flywheels. Accordingly, Comed has revised the following portions of the ISI Program Plan (Attachments 3 and 4) :

1. Appendix C, page C-3, Item J, NDE Method: Deleted VIS abbreviation.

2.

Appendix C, page C-410:

Revised VIS to VT-3 in the NDE Method column.

3. Appendix F, page F-3, Item J, NDE Method: Deleted VIS abbreviation.

4.

Appendix F, page F-396: Revised VIS to VT-3 in the NDE Method column.

F.

Request for Relief 12R-01 addresses limited coverage for several RPV welds.

However, in some cases, coverage estimates are not explicitly stated.

For the circumferential shell welds (RPVC-NR19), what is the estimated coverage from the shell course side? For the shell-to-flange welds (RPVC-NR7), can 100 percent coverage for transverse reflectors be achieved in two directions?

If not, provide an estimate of the coverage.

3 l

_ - ~ -. - -

RESPONSE

l Relief Request I2R-01 has been revised to provide detailed information regarding the limited examination of Reactor Vessel Welds RPVC-WR-16 and RPVC-WR29.

The Reactor Vessel shell-to-flange weld, RPVC-WR7, was examined completely (100% of Code required weld volume) during the recent ten year refueling outage. Accordingly, the limited examination relief for this weld was deleted from I2R-01.

Revised Relief Request I2R-01 is included in G.

Request for Relief Z2R-05 proposes a "best-effort" UT examination of one inlet and one outlet nozzle-to-vessel weld in the residual heat removal heat exchanger. Describe the proposed best-effort examination and provide an estimate of the Code-required coverage that can be obtained.

RESPONSE

Relief Request I2R-05 has been revised to address these questions (Attachment i

2).

This relief request is consistent with provisions of the NRC's Safety Evaluation Report dated February 29, 1996, which granted relief for Interval 1, per Relief Request NR-18.

i H.

Request for Relief Z2R-07 requests approval to examine thin-walled (<3/8")

Class 2 piping welds. Based on review of the examination tables contained in the Program Plan, volumetric examinations have been shif ted to piping <3/8" nominal thickness without a reduction in the overall volumetric snaple size of 7.5 percent. However, it appears that the surface examination snaple has been reduced significantly.

Verify that a surface exnmination snaple of at least 7.5 percent of the Class 2 weld population will be examined during the second 10-year interval.

RESPONSE

Comed acknowledges the discrepancy in the surface examination sampling proposed in this relief request and has revised I2R-07 to include a surface examination for welds with nominal thickness less than 3/8 inches (Attachment 2).

In addition, Appendices C and F have been revised to reflect the surface examination requirement for these welds (Attachments 3 and 4).

I.

Request for Relief Z2R-09 proposes to examine the saddle plate welds in lieu of examination of circumferential branch connection welds.

Provide the staff with a list of the subject branch connections and the unique identifiers for these valds.

RESPONSE

A list of the subject welds is included in Tables 1 and 2 of I2R-09 i

(Attachment 2).

j 4

~

i I

J.

Request for Relief 12R-14 seeks relief from the Code-required pressure testing for Diesel Generator subsystem components (i.e., Starting Air, Jacket Cooling Water, and Lube 011 subsystems).

The proposed alternative is to use the surveillance requirements of the Technical Specificationst however, the specifics of this alternative are not clear.

In addition, the burden associated with the Code requirements is not specified.

Provide a technical discussion describing the proposed alternative and how it will provide an acceptable level of quality and safety, and/or describe the burden associated r

with performing the Code-required pressure tests.

RESPONSE

Comed has reviewed Relief Request I2R-14 further and determined that it may be affected by pending procedure revisions and revisions to the Technical Specifications through the Improved Technical Specification (ITS) effort.

Based on this review, this relief request has been withdrawn from the program I

plan submittal, t

K.

Verify that there are no additional relief requests, other than those in the February 23, 1996 submittal.

If additions 1 relief requests are required, the licenses should submit them for staff review.

RESPONSE-i l

Additional relief requests have been provided for code cases N-416-1, N-498-1, N-509 and N-521 per response to RAI question D.

These relief j

requests are included in attachment 2).

No other relief requests are j

required at this writing.

1 l

I i

i J

l I

i 1

i 5

i