ML20116J750

From kanterella
Jump to navigation Jump to search
Forwards Rev 3 to LaSalle County Station IST Program for Pumps & Valves
ML20116J750
Person / Time
Site: LaSalle  
Issue date: 11/09/1992
From: Shields J
COMMONWEALTH EDISON CO.
To: Murley T
Office of Nuclear Reactor Regulation
Shared Package
ML20116J755 List:
References
NUDOCS 9211160341
Download: ML20116J750 (3)


Text

e;

.p

. ;, s

/

Y 'Commonw:alth Edis n'

> t ~i :

i

/ 1400 Opus Placs

(

. Cowners Grove, Illinois 60515 e.-

Noven:ber 9,1992 i

4

= Dr. T.E. Murley, Director Office of Nucle r Reactor Regulation U.S. Naclear Regulatory Commission i

Washington, D.C. 20555 Station Units 1 and 2

Subject:

. LaSalle County (IST) Program Inservice Test a

NRC DQ.Che1&s,50-373and 50-37_4 e

Reference:

-(a) W.E. Morgan letter to Dr. kJrley, dated October 2,1989, Transmitting Revision 2 to the LaSalle IST Program

Dear Dr. Murley,

l Reference (a) transmitted Revision 2 to LaSalle County Station's IST Program.

Since that time, reviews of the program and plant modifications have been performed which necessitate revision of the Program. Attached is Revision 3 of the LaSalle Units 1 and 2 IST Program, and a Summary of Changes lieting, Please contact this office with any questions.

i Sincarely, JoAnn Shields Nuclear Licensing Administrator

Attachment cc
- A.B. Davis, Regional Administrator - Rlli R. Stransky, Project Manager - NRR D.L Hills, Senior Resident inspector - LSCS Office of Facility Safety - lDNS.

1, l

130043 i

JS/lk :

g i

-j

ZNLD/2285 -

9211160341-921109

',i)iW PDR ADOCK'0500o373 4

p PDR i

2 1

m Ihrervice Testing Frogram Suttmory of Changes for Revision 3 OSR/ 92-036

References:

1) NRC Inspection Report 373(374)/92015 June 15,'1992 through July 9, 1992
2) AIR 373-251-92-00098 "IST Program OM-6 Pump Requirements"
3) AIR-373-100-92-01503 " Track Re/ision to Relief Request RV-26"
4) AIR 373-251-90-00034 " Extrapolation & Trending Requirements for Appendix J Containment Isolation Valves" The LaSalle Incorvice Testing Program is being revised based on a NRC audit performed during June and July of 1992 (Reference 1).

This revision also includes other changes which stem.from other program reviews and non-IST changes.

The following is a short summary of the program changes.

1) Relief Request RP-11 has been addod to Section 5.

Relief Request RP-11 now goveras pump different.al pressure and *zowrate acceptance criteria.

j

2) Note 16 has been deleted from Section 3.2.

The contents and actions of this Note.have been addressed-by Relief Request RP-11.

All references to Not 16 have been deleted from Section 4.

(Note:

This revision does have a Note 16, however in the previous a

revision this "as Note l'.

Since the previous Note 16 was. deleted Note 17 became Note _16.)

3) Relief Requast RV-19 has been revised. per requirements of-Generic Letter 89-04.

Leak-rate results for Containment Isolation Valves will not be trended and extrapolated.

The revised Relief Request has been included in Section 7.

4)F lief Request RV-26 has been revised per requirements of IST Prog 1am SER and NRC Audit (Reference 1).

Individual stroke times for Scram Discharge Volume Vent and Drain Valve-will be recorded and trended..The revised Relief Request has been included in Section'7.'

The stroke time test has been added to the Test

.fic.ld of Section 6 and'to the Valve / Surveillance Cross Reference Matrix.

5) Fail safe test for 1(2)B33-F019 was not included as a required test'in the previous revisions, this was a typographical u

omission.-

LaSalle Station has been performing a f ail safe test on these valves however, it was not documented as a requirement in the IST Program.

The fail safe test requirement has been added to the

- Test fields of Section 6 and to the Valve / Surveillance Cross Reference and is included in this revision.

J

q

.6) Leak rate' test has been added to-the Test field'of Section-6 and the Valve / Surveillance Cross Reference Matrix for the following valves:-

.1 (2 ) E2 2 -F014 1(2)E21-F018

.1(2)E21-F031 1 ( 2 ) E12 -F005 1(2) E12-F025A/B/ C 1 ( 2 ) E12-F030 1(2)E12-F055A/B 1(2)E12-F088A/B/C 1(2)E12-F311A/B 1 (2 ) E12-F03 6 A / B 1 ( 2 ) E51-F022 1(2)E51-F059 7)Three Unit 2 HPCS valves are being removed from the-IST.

program.

The valves, 2E22-F001, 2E22-F010, and 2E22-F011, are located on the piping which connects the Condensate Storage Tank to -

the HPCS System.

This' piping has been capped and LaSallelis no longer taking credit for this piping.

Specifications have not 'been revised. The UFSAR and Technical to reflect this change',

however, AIR 373-160-90-00041 is tracking' this update.

The s

corresponding valves in Unit 1

are scheduled for the same modification during L1R05.

These valves will be deleted from the-IST Program in'a subsequent revision.

\\

l

.J I

)

1

~

l

.