ML20116H641

From kanterella
Jump to navigation Jump to search

Forwards Application for Amend to License NPF-3,revising TS 3/4.5.2,Emergency Core Cooling Sys - ECCS Subsystems - T,Ts 3/4.5.2 & 3/4.5.3,emergency Core Cooling Sys - ECCS Subsystems
ML20116H641
Person / Time
Site: Davis Besse Cleveland Electric icon.png
Issue date: 11/09/1992
From: Shelton D
CENTERIOR ENERGY
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20116H642 List:
References
2084, TAC-M84912, NUDOCS 9211130219
Download: ML20116H641 (2)


Text

e CENTERDOR ENERGY Donald C, Shelton 300 Madison Avenue Vee President Nxlear Toledo, OH 436524001 Dus Passe (419)2G2300 Docket Number 50-346 i

License Number NPF-3 Serial Number 2084 November 9, 1992 United States Nuclear Regulatory Commission Document Control Desk

'Jashing ton, D.C.

20555

Subject:

License Amendment Request to Revise Technical Specification (TS) 3/4.5.2, Emergency Core Cooling Systems - ECCS Subsystems - T 2 280' F, TS Bases 3/4.5.2 and 3/4.5.3, Emergency Core"D6oling Systems - ECCS Subsystems, and TS Bases 3/4.6.2.1, Containment Systems - Depressurization and Cooling Systems - Containment Spray System i

l Gentlemen:

Enclosed is an application for an amendment to the Davis-Besse Nuclear Povs. Station (DBNPS), Unit Number 1, Operating License Number NPF-3, Appendix A Technical Specificatione tTS). This application requests l

revision of TS 3/4.5.2, Emergency Core Cooling Systems -- ECCS l

Subsystems - T 2 280' F; TS Bases 3/4.5.2 and 3/4.5.3, Emergency l

CoreCoolingS$Efems-ECCS Subsystems; and TS Bases 3/4.6.2.1, Containment Systems - Depressurization and Cooling Systems -

Lontainment Spray System, to reflect the proposed de-energization of the Borated Water Storage Tank (BWST) outlet isolation valves DH-7A and DH-7B in their open position, during operational Modes 1, 2, 3, and 4.

This change vould allov the restructuring of the minimum shift crew composition for a Control Room fire since the required fire protection safe shutdown duties of one equipment operator would be substantially reduced. The remaining fire protection safe shutdawn responsibilities of that equipment operator could be assigned to aimther on-shif t h-t operator.

No change is necessary to the TS-required staffing of the BO minimum shift crew composition (TS 6.2.2a) or the. fire brigade (TS C.

6.2.2f).

(Note: The NRC has issued License Amendment Number 174 H"

(September 22, 1992) deleting TS 6.2.2f.

However, this deletion is not l

Ef9 projected to be implemented in the DBNPS TS until December 21, 1992, s

and. therefore, it is shown on the attached TS pages.)

9211130219 921109 PDR ADOCK 05000346 l

P pop n

Operating Comparues.

\\y O 5

CleWond Eleenic mununohng

'\\

Toledo Edison

Docket Number 50-346 License Number NPF-3 Serial Number 2084 Page 2 As a related change, Surveillance Requirement 4.5.2.d.2.b is proposed to be revised to reflect the testing of the valves' interlocks only during times of energization.

The above approach vas discussed in a meeting between Toledo Edison and the NRC Staff (Messrs. J. Hopkins and F. Orr) on May 14, 1992 at the NRC's Rockville, Maryland offices.

The proposed change Ior valves DH-7A and DH-7B is similar to a TS Bases change r viding valves DH-9A and DH-9B (the Containment Emergency Sump recircid valves) accepted by the Nuclear Regulatory Commission (NRC) in.

ter of October 21, 1992. The enclosed application also adds a sim!m. Bases change to TS Bases 3/4.6.2.1 (Containment Spray System) for ccc e t ncy purposec.

Toledo Edison requests that the NRC approve this application by June 1, 1993.

If you have any questions regarding this amendment application, please contact Mr. R. V. Schrauder, Manager - Nuclear Li insing, at (419) 249-2366.

Very truly yours, jf*)

0 l

MYp/

c attachment ec:

A. B. Davis, Regional Administrator, NRC Region III

~

J. B. Hopkins, DB-1 NRC/NRR Senior Project Managtr S. Stasek, NRC Region III, DB-1 Senior Resident Inspector J. R. Villiams, Chief of Staff, Ohio Emergency Management Agency, State of Ohio (NRC Liaison)

Utility Radiological Safety Bosrd

--- -----__ __ _ _ _ _ _ _ _ _ _ _, _ _ _ _ _ _ _, _ _ _ _ _ _ _ _ _ _ _ _ _ _ _, _, _ _, _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ___