Revised Selected Licensee Commitments Manual
ML20116B325
Person / Time
Site: Catawba  
Issue date: 10/21/1992
From: Nicholson K
DUKE POWER CO.
To:
References
PROC-921021, NUDOCS 9211020145
Download: ML20116B325 (8)


Text

_

ll l

lo.kr 1%, < r (Yawan?

! w t > a11.wp e

l'at.w !n k-l< ur blatucn D hIl o turl X1 O

vt 3 r ct; 1

h DUt(EPOWEH October 21, 1992 RE:

Catawba Nuclear Station Selected Licensee Commitments Effectivo 10/21/92 Attached are revisions to the Catawba Nuclear Station Selected Licensco Commitments.

Please revise your copy as follows:

Remove Insert LOEP Page 1 (10/92)

Page 1 (10/21/92)

O Page 2

( '10 / 92 )

Page 2 (10/21/92)

Pago 3 (10/92)

Pago 3 (10/21/92)

Page 4 (10/92)

Page 4 (10/21/92) i l

Chapter 16.7 i

Page 1 (10/21/92)

Page 2 (10/21/92) i Page 3 (10/21/92)

Any questions should be directed to the undersigned at l

803-831-3237.

i

,[

/

f &3 /c M a l +,}

A <.7A

f..

l Kay Nicholson Regulatory Compliance Attachments l

4SLC.LTR (h

C70091 l

9211020145 921021 PDR Av0CK 05000413 P

PDR

'h

)

p

4 DUFE POWER COMPANY SELECTED LICEN't? COMMITM!"i?S MANUAL i

List of Effective Pages Page

_ Revision _ _Da te '

i LOEP 1 10/21/92 i

LOEP 2 10/21/92 LOEP 3 10/21/92 LOEP 4 10/21/92 i

i LoEP 5 10/92 i

i i

Tab 16.0 j

4 l

16.0-1 12/90 i

i f

Ta b,,,16.1 i

16.1-1 1

j Tab 16.2 16.2-1 11/91 i-16.2-2 11/91 16.2-3 11/91 l

l Tab 16.3 1

i 16.3-1 11/91 16.3-2 11,91

)

l Table-16.3-1 11/91 l

Tab'16.4 I-Page 1 10/21/92

__-._.-____.._z..,._.m

. ~..... -. - - - - - - _ - -. -

i 4

4 DLTKE POWER COMPANY SELECTED LICENSEE COMMITMENTS MANUAL I

List of Effective Pages Page Rovision Date i

j Tab 16.5 16.5-1 11/91

-i 16.5-2 11/91 j

16.5-3 11/91 i

i j(

Tab IG.6 l

J Tab 16_.7_

d Page 1 10/21/92 l

Page 2 10/21/92 8

I Page 3 10/21/92 LO Tab 16.8 4

i j

Tab 16.9 Pace 1 07/92 Page 2 07/92

[

Pago 3 07/92 i

Page 4 07/92 a

i Pace 5 07/92 Page'6 07/92 1

Page 7

-07/92 5

Page 8 07/92 Page 9-07/92-e Page 10 07/92 Page:2 10/21/92-d 1

N

-.,,,~-,-.-...-..,,-,,.,.-,.,,,,,--,..,-.--~..-,,,,....,+-,,,,,,n.,

,.,m....,

p..._...__.

f j

l

^

?

i f

DUKE POWER COMPANY SELECTED LICENSEE COMMITMENTS MANUAL l

List of Effective Pages Page Revision Date j

Page 11 07/92 J

Page 12 07/92 a

1' Page 13 07/92 j

Pago 14 07/92 4

j Page 15

,7/92 i

)

Pago 16 07/92 t

Page 17 07/92 i

Pago 48 07/92 i

Page 19 07/92 1

j Pago 20 07/92 l

Page 21 10/92 1

Pago P2 10/92

.l Page 23 07/92 i

i Pago 24 07/92 i

l Page 25 07/92-Pago 26 10/92 I

Page 27 07/92 Page 28 10/92 4

i J

Tab 16.10 i

16.10-1 02/91 16.10-2 02/91 j

Page 3 10/21/92 i

--aw'*

--m-

"'--e' nw

-.-e

,-s.

..,r*w-----ew

<+=*-v=-=

- - e ww e --

v-v, era-r------

r

..._.___...m_.

. _ _ _ _ _ _ _.. _ _ _.. _ _ _ _ _ _.. _.. _ _ _. ~ _ _ _ _.. ~ _ _ _ _

l

}

d I-t i

i J

DUKE POWER COMPANY SELECTED LICENSEE COMMITMENTS MAINAL i

3 List of Effective Pages a

1 Page povision Date Tab 16.11

i 1

Tab 16.12

'l j

Tab 16.13 16.13-0 12/90

)

16.13-1 12/90 4

Tab 16.14_

Tab 16.15 i

a i

1 a

1 4,

I 4

4

]

Page 4 10/21/92 i.

1 1

CATAWHA NUCLEAR STATION FINAL SAFETY ANALYSIS REPORT SELECTED LICENSEE COMMITMENTS CHAPTER 16.7 INSTRUMENTATION Table of Contents 16.7-1 ATWS Mitigation System Actuation Circuitry (AMSAC)

O c

O CHAPTER 16.7 Page 1 10/21/92

J t

16.7_

INSTRUMENTATION 16.7 ATWS MITIGATION SYSTEM ACTUATION CIRUITRY (AMSAC) i COMMITMENT:

.j The AMSAC System shall be OPERABLE.

4 APPLICABILITY:

)

MODE 1, above 40% of RATED THERMAL POWER (based on Turbino impulso j

Prousure).

i REMEDIAL ACTION:

j With the AMSAC System inoperablo, restore it to OPERABLE status within 7 days or submit a special Report to the Nuc1 car Regulatory i

i Commission within the following 30 days. This report shall outlino j

the cause of the malfunction and the plans for restoring the system j

to OPERABLE status.

TESTING REQUIREMENTS:

Perform a CllANNEL CALIBRATION on the AMSAC System instruments at least once por 10 months.

1

REFERENCES:

1 1) 10 CFR 50.62, Requirements for Roduction of Risk From l

Anticipated Transients Without Scram ( ATWS) Events for Light-j Water Cooled Nuclear Power Plants.

2)

Generic Letter 85-06, " Quality Assuranco Guidanco foc ATWS Equipment That Is Not Safety-Rolated."

3)

Information Notice 92-06, "Ro11 ability of ATWS Mitigation System and Other NRC Required Equipment Not-Controlled by

- Plant Technical Specifications."

i CHAPTER 16.7 Page 2 10/21/92 I

-e-

-,-,e n.m--r--,e,--.s e-~~

e

,,--,4.

-.-,-,-.-anyw

,e,,-,,wn,.,.

.,w---ge,-

n. -,,,,

.,..w.

e-

,----m, m,a _ v,

I t

DASES:

Por 10 CFR 50.62, "Each pressurized water roactor must have equipment from sensor output to final actuation device, that is diverso from the reactor trip system, to automatically initiate the auxiliary foodwater system and initiate a turbino trip under conditions indicative of an ATWS.

This equipment must be designed i

to perform its function in a rollable manner and be independent i

f rom the existing reactor trip syst em."

When this rule was issued, i

the NRC did not require licensees to address the OPERABILITY of this equipment in the plant Technical Specifications nor require that this equipment be designated as safety-related.

1 On January 15, 1992, the NRC issued-Information Notico 92-06 which discussed the reliability of AMSAC and other equipment not controlled by plant Tecnnical Specifications.

This notice j

described two separato incidents where violations were cited becsuae the licenseos f ailed to adequately maintain the reliability d

of their AMSAC systems.

The NRC la concerned that licensees may not place an appropriato level of priority on resolving problems with the AMSAC system because it is not a safety-related system and because the plant's Technical Specifications do not govern its i

operability.

The NRC considers the failure of licensoos to adaquately ensure the rollable operation of AMSAC equipment to be a significant regulatory. concern.

4 This Selected Licenseo Commitment was developed to ensure that k

appropriate attention is given to maintaining the AMSAC System in i

a reliable condition and that prompt action will be taken to repair j

and restore any AMSAC equipment that is discovered in a condition where it is incapable of performing its intended function.

i 1

i.

1 i

I

.l -

4 a

CHAPTER 16.7 Page 3 10/21/92 a

-.....