m.g wm Nuckw%mtionsOpartment l'icelttsklent.
NIKhWof97Ution$.
Ibst Ofwelka.Kf/4 One]anksR:n7itca Ruhnomt SirginiaLW1 49 April 15, 1985 was,m, -,
Mr. Harold R. Denton, Director Serial No.85-163 Office of Nuclear Reactor Regulation N0/JHL:acm Attn:
Mr. James R. Miller, Chief Docket Nos. 50-338 Operating Reactors Branch No. 3 50-339 Division of Licensing License Nos. NPF-4 U. S. Nuclear Regulatory Commission NPF-7 Washington, D. C. 20555 Gentlemen:
VIRGINIA POWER NORTH ANNA POWER STATION UNIT NOS. 1 AND 2 PROPOSED TECHNICAL SPECIFICATION CHANGES Pursuant to 10 CFR 50.90, Virginia Power requests an amendment in the form of changes to the Technical Specifications for Operating License Nos.
NPF-4 and NPF-7, for North Anna Unit Nos.1 and 2.
The proposed Technical Specification changes are to revise the minimum decay _ time prior to fuel movement.
Technical Specification 3/4 9.3 requires that there must be a minimum decay time of 100 hours0.00116 days <br />0.0278 hours <br />1.653439e-4 weeks <br />3.805e-5 months <br /> prior to any fuel movement. UFSAR Section 9.1.3.1 assumes a minimum decay time of 150 hours0.00174 days <br />0.0417 hours <br />2.480159e-4 weeks <br />5.7075e-5 months <br />. The proposed change is to revise Technical Specification 3/4 9.3 to have a minimum decay time of 150 hours0.00174 days <br />0.0417 hours <br />2.480159e-4 weeks <br />5.7075e-5 months <br /> prior to fuel movement. This would keep the Technical Specifications within the boundaries of the UFSAR design basis.
The proposed Technical Specification changes for North Anna Unit No.1 are provided in Attachment 1.
The proposed Technical Specification changes for North Anna Unit No. 2 are provided in Attachment 2.
A discussion of the proposed Technical Specification changes is provided in Attachment 3.
This request has been reviewed and approved by the Station Nuclear Safety and Operating Committee and the Safety Evaluation and Control Staff. It has been determined that this request does not involve an unreviewed safety question as defined in 10 CFR 50.59.
It has been determined that these proposed changes does not pose a significant hazards consideration as defined in the Federal Register dated April 6,
1983. The basis for this determination is provided in example (11) which states, "A
change that constitutes an additional limitation, restriction or control not presently included in the technical specifications:
for example a more stringent surveillance requirement". The proposed changes do create an additional limitation by extending the decay time from 100 hours0.00116 days <br />0.0278 hours <br />1.653439e-4 weeks <br />3.805e-5 months <br /> to 150 hours0.00174 days <br />0.0417 hours <br />2.480159e-4 weeks <br />5.7075e-5 months <br /> prior to fuel movement.
0 0504230200 050415 PDR ADOCK 05000330
) g P
PDR 4 $ /M
-V O
We have reviewed this request in accordance with the criteria in 10 CFR 170.12.
A voucher check in' the amount of $150 is enclosed as an application fee.
Very truly your,
p4 F
W. L. Stewart Attachments 1.
Proposed Technical Specification Changes - Unit 1 2.
Proposed Technical Specification Changes - Unit 2 3.
Discussion of Proposed Technical Specification Changes 4.
Voucher Check for $150 cc: Dr. J. Nelson Grace Regional Administrator.
Region II Mr. M. W. Branch NRC Resident Inspector North Anna Power Station Mr. Charles Price Department of Health' 109 Governor Street Richmond, Virginia 23219 i
f a
COMMONWEALTH OF VIRGINIA )
)
CITY OF RICHMOND
)
The foregoing document was acknowledged before me, in and for the City and Commonwealth aforesaid, today by W.
R.
Cartwright who is Manager-Nuclear Operations Support, of Virginia Power.
He is duly authorized to execute and file the foregoing document in behalf of that Company, and the statements in the document are true to the best of his knowledge and belief.
Acknowledged before me this W day of flonk
, 19 i G My Commission expires:
- 9chwun,
\\0 1996 s
g t N a\\%
Notary Public am nn (SEAL) s/001
.- -