Proposed Tech Specs Clarifying Surveillance Interval for Surge Tank Level Instrumentation
ML20115C418
Person / Time
Site: South Texas  
Issue date: 07/08/1996
From:
HOUSTON LIGHTING & POWER CO.
To:
Shared Package
ML20115C417 List:
References
NUDOCS 9607110329
Download: ML20115C418 (2)


Text

.

l i

i 4

1 4

ATTACHMENT 3 i

MARKUPS OF PROPOSED CHANGES i

l TO TECHNICAL SPECIFICATIONS t

i i

i 9607110329 960708 Ill PDR ADOCK 05000498 P

PDR J

l

ST-HL-AE-5402 l

File No.: G20.01, G21.01

^

Page 1 of1 l

- PLANT SYSTEMS 3/4.7.3 COMPONENT COOLI'NG WATER SYSTEM LIMITING CONDITION FOR OPERATION l

~ 3.7.3At least three independent component cooling. water loops shall be OPERABLE.

APPLICABII ITY: MODES 1,2,3, and 4.

j ACTION:

i With only two component cooling water loops OPERABLE, restore at least three loops to OPERABLE status within 7 days or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

SURVEILLANCE REOUIREMENTS 4.7.3 At least three component cooling water loops shall be demonstrated OPERABLE:

l 1

a. At least once per 31 days by verifying that each valve outside containment (manual, power-operated, or automatic) servicing safety-related equipment that is not locked, sealed, or otherwise securedin l

position is in its correct position; and

b. At least once per 18 months du-in;; du&=, by verifying that:

1)

Each automatic valve servicing safety-related equipment or isolating the non-nuclear. safety l

portion of the system actuates to its correct position on a Safety Injection, Loss of Offsite i

power, Containment Phase "B" Isolation, or Low-Surge Tank test signal, as applicable (oerformed during shutdown),

2)

Each Component Cooling Water System pump starts automatically on a Safety Injection or

)

Loss of Offsite Power test signal (nerformed during shutdown); and

3) The surge tank level instrumentation which provides automatic isolation of portions of the system is demonstrated OPERABLE by performance of a CHANNEL CALIBRATION test.

1

c. By verifying that each valve inside containment (manual, power-operated, or automatic) servicing l

safety-related equipment that is not locked, sealed, or otherwise secured in position is in its correct position prior to entering MODE 4 following each COLD SHUTDOWN of greater than 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> if not performed within the previous 31 days.

SOUTH TEXAS - UNITS 1 & 2 3/4 7-12 Unit 1 - Amendment No. -4,59 l

Unit 2 - Amendment No. 47 TsC-96'5402