_f tOctober712,o1992 7

s i

,gyg v

e.t.

U. S.

Nuclear Regulatory Commission

-Attention: Document Control Desk

)

iWashington,-D.

C.

20555 e

a

Subject:

McGuire Nuclear Station, Unit 1 Docket-Number: 50-369-J Inservice Inspection PlanL(ISI)

Second Interval Plans'for unit'1 Relief _ Request _92-03

Dear Sir; The Commercial Service Dato for McGuire Nuclear Station, LUnit iris December 1, 1983.

As specified by Section XI of-

'thelASME Boilor and Pressure Vessel Code,.the first interval-

. for = Unit 1 'was, from DecerrSer '1, 1981 ' to December = 1, 1991.

' Pursuant to;IWA-2400(c) tr'e first interval waE ~ ertended an

additional year..: As:such,-the first: interval for Unit 1 1

1will-end: December 1, 1992..

r x

7'

.In accordance with'10CFR.i0.55a(g)(4)(11),-the: ISIcprogram-

^

for Unit-1 shallibe revised to complyEwith the requirements-

~

ofitheD-latest edition and' addenda of:the code ~ incorporated c

P.

bygreference in210CFR50.55a(b).(2) twelve-months. prior'to-the

" art.ofi second 11nnpection-interval'.

The-latest edition of a1 Code-thatLwas referen'ad by paragraph (b) of 10CFR50.55a b

' u-t.: that time was the11986: edition rf the' Code.

'lQ

~

l Pursuant ~to.the-requirements of 10CFRSO.55(a),.attuched

+5-please" find _a_ copy ofLthe ISI plan.for McGuire Nuclear-

'. Station-Un'it511(Volumes 1,2, and 3) to be used during the secondiinterval'.

.In accordance with the requirements.of.

_10CFR50.55a(g), theJISIfplan for Unit'.l'of McGuiro Nuclear-

-Station will be performed <in'.accordance with the 1986-f 1 edition of-LtheLASME Section1X1~

Code..

' /) -

^

~

F 4 r,c.m

. g \\-

- 9210190136 921012

/

I \\

~

PDR' ADDOK 05000369

(

z g_

PDP Sa mu n.;

ihq $.h, _

Q.:.v.

n4,

,,,m w,..

y y,

"s%M s

n=

s

.~+c

-.y

U.

S.

Nuclear Regulatory Commission October 12,- 1992 page 2 To' support-your review of the ISI plan, marked up system piping layout drawings and system isometrics are being prepared.

These drawings will be submitted to you at a later date.

Further, the Calibration Block Listing and Calibration Block drawings (Volume 1 Section 10) are in preparation.

This Section will be submitted in it's entirety ut a later date.

In addition, some of tne class B items do not have Calibration Blocks listed (Volume 2 Appendix A) because the blocks themselves are in the course of preparation.

This information will, also, be provided at a later date.

Included within the ISI plan provided by this letter is a request for relief from certain inspection ctquirements that have been_ determined to be impractical.

Specifically, Volume 1 Section 9 of the ISI plan provides the relief request for NRC review.

Pursuant to 10CFR50.55a(g)(6), NRC approval of the enclosed relief is hereby requested.

An additional request for relief regarding IWP-5000 is currently in preparation and will be submitted at a later date.

In Addition, please note that Volume 1 Section 1.2 of the

-attached ISI plan identifies the Code cases that will be used during the second inspection interval 'or Unit 1.

All

~

of the Code Cases identifiec, except for (:

are listed in revision 9 of NRC Regulatory Guide 1.147, " Inservice Inspection Code Case Acceptability - ASME Section XI Division 1."

The one Code Case that is not listed within i

revision 9 of Regulatory Guide 1.147 is Code Case N-491,

" Alternative Rules for Examination of Class 1,2,3 and MC Component Supports of Light - Water Cooled Power PlantsSection XI, Division 1".

A submittal pursuant to 10CFR50.55a(a)(3) requesting NRC authorization to use this code case is in preparation and will be submitted at a later d~te.

-Please contact Paul Guill at (704) 875-4002 if there are any question regarding this submittal.

Very truly yours,

/

frGKm !

Ted C. McMeekin li I

- U.

S.-Nuclear Regulatory Commission:

October 12, 1992-page-3 xc:

Mr.

S._D.

Ebnetor.

Regional-Administrator, Region II U.

S. Nuclear Regulatory Commission

~

101 Marietta Street, NW, Suite 2900 Atlanta Georgia 30323 Mr.

P..K.

Van Doorn Senior NRC Resident-Inspector, McGuire McGuire Nuclear Station-

-Mr.

T. A.

Reed, Project Manager Office of Nuclear Reactor Regulation U.

S. Nuclear Regulatory Commission One White Flint North, Mail Stop 9H3 Washington, D.C.

20555

-l l

I

{-.-

O

-3 l

I

-1 i

l u

..