Southcrn C lifornia Edison Monthly Report Pags 1 of 17 L

Facility :

songs Unit 3 Exact Sample Point :

Intake and Order No :

94 50 Discharge Conduits Report Freq :

Monthly Collected By :

Songs Envir Grp Report For :

April 1996 Analyzed By :

S gs E vir Grp, Report Due:

May 30,1996 Signed :

b f

i Waste Stream waterintake and Title :. Environm lillfridineer Combined Discharge PARAMETER: Temperature Difference (degrees Fahrenheit) = Temperature at Combined Discharge Minus Temperature at Water intake Combined Date Discharge Water intake Daily I

Avg Avg

' Max Avg Diff

.4 1-96 80 60 61 20 I

4-2-96 80 60 61 20 3-96 81 61 61 20 4-4-96 81 61 61 20 4-5-96 80 61 62 20 4-6-96 80 61 61 19 l

4 7-96 81 60 61 22 4 8-96 90 59 61 31 4-9-96 78 59 60 19 4 10 78 59 61 19

)

4-11-96 80 61 62 19 j

4 12-96 81 62 63 19 i

4-13-96 81 63 63 19 4-14-96 81 62 63 19

)

4 15-96 80 62 62 19 1

41696 80 61 62 19 4-17 96 80 62 63 19 4-18 96 81 62 63 19 4 G-id 78 59 61 19 4-20-96 79 60 61 19 4-21-96 79 60 62 19 4-22 79 60 61 19 4 23-96 78 59 61 19 4-24-96 77 58 59 19 4-25 96 79 60 6 ',

19 4-26-96 81 62 43 19 4-27-96 82 63 64 19 4-28-96 83 64 60 19 4-29-96 83 64 65 '

19 4-30-96 81 63 64 19 Avg.l

'80 61.

62 20 Regt ~

20 Heat Treatment occured : Apr 7, 1996 and Apr 8, 1996 9607110079 960613

~

PDR ADOCK 05000361 S

PDR I

I South;rn California Edison Monthly Roport Paga 2 of17 Intake and i,-

Facility :

Songs Unit 3 Exact Sample Point : Screenwell Order No :

94-50 Report Freq :

Monthly Collected By :

instrumentation i

Report For :

April 1996 Analyzed By :

Son s Envir Grp r

t Report Due :

May 30,1996 Signed ; -

f Report Topic :

Intake conduit and Title : Environmental Engineer Screenwell Heat Treatment l

Intake and Screenwell Heat Treatment Occured This Month.

I PARAMETER UNITS REQUIREMENT RESULT Date/ Time 4/8/96 01:04 am Treatment Began Date/ Time 4/8/96 08:04 am Treatment Ended I

Total Time 7.00 hours0 days <br />0 hours <br />0 weeks <br />0 months <br /> l

of Treatment Maximum Screenwell Temperature Attained degr q00 96 4

(Screenwell Target F

Temperature)

Screenwell Target 7

Temp Duration 1

l Following Section only Completed if Screenwell Target Temperature was Exceeded.

l Maximum Screenwell degr j

Temperature Attained p

N/A

~~

Degrees Above Screenwell degr Target Temperature p

10 N/A i

Maximum Screenwell Temp Duration min 15 N/A i

  • Value Varies (From the Mussel Mortality Graph) j i

i l

l

Southarn California Edison Monthly Report Pcge 3 of 17 Intake and

- Facility :

Songs Unit 3 Exact Sample Point : Screenwell Order No ;

94-50 Report Freq :

Monthly Collected By :

Instrumentation

)

Report For :

April 1996 Analyzed By :

i n

Envir Grp Report Due :

May 30,1996 Signed :

Report Topic :

Intake conduit and Title :EnvironmentalEngineer Screenwell Heat Treatment intake and Screenwell Heat Treatment Occured This Month.

j PARAMETER UNITS REQUIREMENT RESULT Maximum intake Conduit l

Temperature Attained degr 125 116 j

(Intake Conduit Target F

Temperature) 4 Screenwell Target a

ho m 7

l Temp Duration 2.1 s

1 i

Followina Section only Completed if Intake Taraet Temperature was exceeded.

Maximum Intake Conduit degr N/A Temperature Attained F

l Degrees Above intake Conduit.

degr 10 N/A Target Temperature F

Maximum Intake Conduit.

min 15 N/A Temp Duration (Minutes)

  • Value Varies (From the Mussel Mortality Curve) i a

South:;rn California Edison Monthly Report Pago 4 of17 Facility :

Songs Unit 3 Exact Sample Point : Discharge Conduit Order No :

94 50 Report Freq :

Monthly Collected By : Instrumentation Report For :

April 1996 Analyzed By : Song Envir G j

Report Due :

May 30,1996 Signed :

Report Topic :

D scharge Conduit Discharge Conduit and Screenwell Heat Treatment did *NOT* occur this month PARAMETER UNITS REQUIREMENT RESULT i

Date/ Time N/A Treatment Began Date/ Time N/A Treatment Ended Total Time N/A hours.

of Treatment Maximum Discharge Conduit Temperature Attained degr 105 N/A F

l (Discharge Conduit Target

{

Temperature)

i 4

i Following Section only Completed if Screenwell Target Temperature was Exceeded.

j 5

Maximum Screenwell degr Temperature Attained p

N/A

~~

Degrees Above Screenwell degr

- Target Temperature p

10 N/A Maximum Screenwell Temp Duration min 15 N/A

  • Value Varies (From the Mussel Mortality Graph)

I i

  • No HEAT TREAT PERFORMED

i South rn California Edison Monthly Roport Pcgs 5 of 17 Paints cf Facility :

Songs Unit 3 Exact Sample Point :

Discharge Order No :

94 50 Report Freq :

Monthly Collected By : Songs Envir Grp Report For :

April 1996 Analysed By : Songs Envir Grp h

j Report Due :

May so,1996

\\

Waste Stream : Combined Discharge Signed :

Q L

Low Volume Waste Title : Environmental Engineer i

- Parameter : Flow Rate Units : Million Gallons per Day (MGD)

Combined Total Low Total Sewage Date Discharge Volume Waste Treatment 1

1218.656 0.070 0

2 1218.874 0.288 0

3 1218.714 0.128 0

4 1218.824 0.238 0

5 1197.467 0.287 0

6 942.000 0.130 0

'7 1024.408 0.208 0

8 1218.853 0.267 0

9 1218.715 0.129 0

10 1218.842 0.256 0

11 1218.794 0.208 0

12 1218.716 0.130 0

13 1218.840 0.254 0

14 1218.656 0.070 0

15 -

1218.794 0.208 0

16 1218.853 0.267 0

i 17 1218.794 0.208 0

18 1218.712 0.126 0

19 1218.776 0.190 0

l 20 1218.838 0.252 0

21 1218.826 0.240 0

22 1218.714 0.128 0

- 23 1218.656 0.070 0

24 1218.846 0.260 0

25 1218.787 0.201 0

26 1218.712 0.126 0

27 1218.792 0.206 0

28 1218.794 0.208 0

29 1218.793 0.207 0

30 1218.714 0.128 0

Avg 1202.359 0.189 0

Reqt l 1286.900 11.610 0.145 SEWAGE TREATMENT DISCHARGED TO UNIT 1 OUTFALL I

i

E Southnrn Cclifornia Edison Monthly Report Pcg3 6 of 17 Facility :

songs Unit 3

~ Exact Sample Point :

Intake and -

Order No :.

94-50 Discharge conduits Report Freq :

Monthly Collected By :

Songs Envir Grp Report For :

April 1996 Analyzed By :

so os Envi Gip Report Due :

May 30,1996 Signed : '

2

- Waste Stream : cooling water intake Title :

nvironmenta1 Engineer Date &

Sample Req't Reg't Result Time Parameter Units.

Type Type Value Value

. Collected i

GRAB 8.3 4/1/96 11:35 am pH 5.7 4/1/96 11:35 am -

Turbidity.

NTU

. GRAB i

I a

l i

5 4

i I

. Irn Cclifornia Edison Monthly Report Pega 7 cf 17 South:

Facility ::

Songs Unit 3 Exact Sample Point :

. Point of -

Discharge Order No :

94 50 Report Freq :

Monthly.

Collected By :

Songs Envir Grp Report For.:.

April 1996 Analyzed By :

Sony Envir Report Due :.

. May 30,1996 Signed :

O Waste Stream :. Combined Discharge Title nvironmenta ngineer..

Date'&

Sample Req't Reg't Result

.n,

Parameter

. Units.

Type Type Value Value Collected Turbidity NTU GRAB-9.1 4/1/96 01:35 pm 6-9 8.2 4/1/96 01:35 pm pH GRAB ug/l Inst 340

< 4.0 4/16/9610:30 am

Hydrazine Ibs/ day GRAB Max 3954

<40.662 h,8f 2.5 0.13 4/10/96 08:30 am TUm GRAB j

Acute Toxich Weekly 2.0 0.13' 4/10/96 08:30 am Tua GRAB Avg.

"', Y 1.5 0.13 4/10/96 08:30 am TUa' GRAB y

i DaHy 10.0 1.00 4/10/96 08:30 am Chronic TUc GRAB M**

Toxicity i

1 1

l l

i i

.I

\\

l

)

)

~

~

S:uth rn Cclifornia Edison Monthly R3 port Pcgo 8 of 17 Facility :

Songs unit 3 Exact Sample Point :

Point of Order No :

84-s0 Discharge

. Report Freq :

' Monthly.

Collected By :

Songs Envir Grp Report For :

April 1996 Analyzed By :

Songs virG j

Report Due :

May 30,1996

/

Signed :

Waste Stream :. Thermophilic Digester Title :

Environmental Engineer (Low Volume Waste)

Date &

Sample.

Req't Req't Result Time Parameter Units Type Type Value Value Collected j

mg/l Monthly 30 lbs/ day GRAB Avg 2.5 Total m g/l Daily 100 Suspended

. Ibs/ day GRAB Max 8.3 Solids mg/

Inst 100 GRAB Max 8.3 lbs/ day mg/l Monthly 15 lbs/ day GRAB Avg 1.3 Grease.

and mg/l Daily 2

GRAB Oil Ibs/ day Avg 1,7 a

=

mg/l Inst 20 GRAB lbs/ day Max 1,7

=

a 4

1

)

h

  • NO FLOW - SYSTEM NOT INSTALLED

South rn Cclifornia Edicon Monthly Roport Pfg3 9 of 17 Facility :

Songs Unit 3 Exact Sample Point :

Point of Order No :

94 50 Discharge Report Freq :

Monthly Collected By :

Songs Envir Grp

- Report For :

April 1996 Analyzed By :

ongr E vir GP 7

' Report Due :

May 30,1996 Signed :

b%

Waste Stream :

Condenser Hotwell Title :

Environmental Engineer Overboard (Low Volume Waste)

Date &

Sample Req't Req't Result Time Parameter Units Type Type Value Value Collected mg/l Monthly 30 Ibs/ day GRAB.

Avg 1800 Total mg/l Daily 100

. Suspended Ibs/ day GRAB Max 6000 Solids mg/

inst 100 GRAB Ibs/ day Max 6000 mg/l Monthly 15 lbs/ day GRAB Avg 900 Grease and mg/l DaHy M

GRAB l

oil lbs/ day Avg 1200 i

mg/l Inst 20 GRAB Ibs/ day Max 1200 i

l 1

  • No FLOW IN APRIL 1996

1

. South 3rn Cclifornia Edinon Monthly Report Pcga 10 of 17,

Facility :

Songs Unit 3 Exact Sample Point :

Point of Order No :-

94-50 Discharge Report Freq :-

Monthly Collected By :

Songs Envir Grp

' Report For :

April 1996 ;

Analyzed By :

onfis nvir Report Due :

May 30,1996

/

Signed :~

- Waste Stream :

Steam Generator Title

- Environmental Engineer overboard (Low Volume Waste)

Date &

Sample Req't Req't Result Time Parameter-Units Type Type Value Value Collected o

mg/l Monthly 30 lbs/ day.

GRAB Avg 180-i Total mg/l Daily 100-

- Suspended Ibs/ day GRAB Max 600 Solids Inst 100 mg/ --

GRAB lbs/ day Max 600

=

m g/l Monthly 15 lbs/ day.

GRAB.

Ayg go Grease DaHy '

N and

_ m g/l GRAB Oil lbs/ day Avg 120 mg/l inst 20 GN lbs/ day Max 120 i

k h

i t

I-b 4

  • No FLOW IN APRIL 1994, I

l South rn CSlifornia Edison Monthly Report.

Pag 311 of 17

. Facility :

Songs Unit 3 Exact Sample Point :

Point of Order No :

94-50

. Discharge Report Freq :

Monthly Collected By :

Songs Envir Grp Report For :

April 1996 Analyzed By :

Songs,

' ir Report Due :

May 30,1996 Signed :

Title -

Environmental Engineer -

Waste Stream :

Blowdown Proce ssing System Regeneration (Low Volurce Wr4ste) '

Date &

Sample Req't Req't Result Time Parameter Units

' Type Type Value Value Collected mg/l Monthly 30 Ibs/ day GRAB Avg 21 i

Total mg/l Daily 100 Suspended Ibs/ day '

GRAB Max 71

=

Solids i

mg/

Inst 100 GRAB lbs/ day Max 71 a

mg/l Monthly 15 lbs/ day GRAB Avg g

Grease and mg/l DaHy N

GRAB oil lbs/ day Avg 14

=

mg/l GRAB lbs/ day Max 14 d

  • No FLOW IN APRIL 1996 '

1

-South 3rn Cclifornin Edi::on Monthly Report Pcg3120f17 Facility :

Songs Unit 3 Exact Sample Point :

Point of Order No :

94-50 Discharge t

l Report Freq :

Monthly

. Collected By :

Songs Envir Grp

' Report For : ~

April 1996 -

' Analyzed By :

onos Envi, G g

Report Due :-

May 30,1996

^

Signed :

4

Waste Stream

Full Flow Cond.

Title :

Environme i Engmeer

' Polish Domineralizer (Low Volume Waste)

Date &

l Sample Req't Req't.

Result Time Parameter Units Type Type Value Value Collected i

i mg/l Monthly 30 5.4 412/96 l

Ibs/ day GRAB e-Avg

-350 3.74

' 02:55 am Total

,,fi paily 100 5.4 4/2/96 GRAB Suspended Ibs/ day Max 1200 6.26 02:55 am Solids mg/

Inst 100 5.4 4/2/96 GRAB l

Ibs/ day Max 1200 6.26 02:55 am t

m g/l Monthly 15 2.0 4/2/96.

4 lbs/ day GRAB' Avg 180

< 1.38 01:34 am Grease '

and mg/l Daily 20' 2.0 4/2/96 GRAB Oil:

lbstday Av9 230

< 2.32 01:34 am I"

mg/l Inst 20 2.0 N2/M GRAB ibs/ day Max 230

< 2.32 01:34 am 6

l l

1 4

i t

' i i

2 3

South rn Cclifornia Edison Monthly Report Psg313 of 17 Facility :

Songs Unit 3 Exact Sample Point :

Point of Discharge Order No :

94 50 Report Freq :

MontMy Collected By :

Songs Envir Grp April 1996 Report For:

Analyzed By :

pongs vir 9

- Report Due :'

Mey 30,1996 Signed :

Title :

Environmenkal Engineer Waste Stream :

Radwaste System (Low Volume Waste)

Date &

Sample Req't Req't Result Time Parameter Units Type Type Value Value Collected mg/l Monthly 30 2.5 511/96 lbs/ day GRAB Avg 110

< 0.04 08:15 pm Total mg/l Daily 100 2.5 4/1/96 GRAB Max 360

< 1.06 08:15 pm Suspended Ibs/ day Solids mg/

Inst 100 2.5 4/1/96 GRAB Max 360

< 1.06 08:15 pm Ibs/ day mg/l Monthly 15 2.0 4/1/96 lbs/ day GRAB Avg 54

< 0.03 08:15 pm DaHy M

2.0 M

nd mg/l GRAB Oil lbs/ day Avg 72

< 0.85 08:15 pm mg/l inst 20 e

2.0 4/1/96 GRAB Max 72

< 0.85 08:15 pm Ibs/ day r

4 E

L

(

a

South:rn Cclifornia Edison Monthly Rcport Paga 14 of 17 Facility : -

Songs Unit 3

Exact Sample Point :

Point of

' Order No :

_94 50 Discharge Report Freq :

Monthly Collected By :

Songs Envir Grp Report For :

April 1996 Analyzed By :

Song Epvir rp 4

Report Due :.

May 30,1996 Signed :.

)

Waste Stream :

Intake Sump Title :

Environmental 'ngineer (Low Volume Waste)

Date &

Sample Req't Req't Result Time Parameter Units Type Type Value.

Value Collected mg/l Monthly 30 10.9 4/5/96 lbs/ day GRAB Avg 72 6.36 08:20 am Total mg/l Daily 100 10.9 4/5/96

' Suspended Ibs/ day.

GRAB Max 240 6.36 08:20 am Solids mg/

Inst 100 10.9 4/5/96 GRAB Max 240 6.36 08:20 am Ibs/ day i

mg/l Monthly 15 5.6 4/5/96 lbs/ day GRAB Avg 36 3.27 08:20 am Groase and mg/l DaHy 3

56 4/5/96 I

GRAB Oli Ibs/ day.

Avg 48 3.27 08:20 am mg/l Inst 20 5.6 4/5/96 GRAB Max 48 3.27 08:20 am lbs/ day 4

i I

s

-South rn Cdifornia Edison Monthly Roport Pcg315 of 17 Facility :

Songs Unit 3 Exact Sample Point :

Point of Order No :

94 50-Discharge Report Freq : -

Monthly Collected By :

Songs Envir Grp Report For :.

April 1996 Analyzed By :

jongs 3

i vir k

l Signed :

My

)

Report Due :

May 30,1996 Title :

Environmenbl Engineer

]

Waste Stream :

Building Sumps (Low Volume Waste) j Date &

I

. Sample Req't Reg't Result Time Parameter Units Type Type Value Value Collected i

mg/l Monthly 30 l

4 lbs/ day GRAB i

Avg 200 Total mg/l Daily 100 GRAB Suspended Ibs/ day Max 670 Solids.

3 mg/

Inst 100 GRAB lbs/ day Max 670 i

mg/l Monthly

-15 lbs/ day GRAB Avg 100 Grease and-mg/l DaHy M

GRAB Oil -

Ibs/ day Avg 130 mg/l inst 20 NB lbs/ day Max 130 4

n

' ' DISCHARGED To UNIT 2, j

i South rn Ccliforn16 Edicon Monthly Report Page.16 of 17 Facility :

Songs Unit 3 Exact Sample Point :

Point of 1

Order No :

94-50 Discharge Report Freq :

Monthly Collected By :

Songs Envir Grp l

Report For:

April 1996 Analyzed By :

ongs Ervir G

{

j Signed :

O Report Due :

May 30,1996 Waste Stream :

Makeup Demineralizer Environment Ibgineer

- Title -'

(Low Volume Waste)

Date &.

l SamPe Req't Req't Result Time Parameter Units.

Type Type Value -

.Jalue Collected -

3 3

mg/l Monthly 30 3.5 4/20/96 i

GRAB lbs/ day Avg 170 1.02-

. 01:14 pm 1

i

. Total

~ 100 6.4 4/20/96 l

,,fi o isy Suspended Ibs/ day GRAB Max 560 3.31 01:14 pm j.

. Solids mg/

Inst 100 6.4 4/20/96 GRAB Max 560 3.31 01:14 pm i

I lbs/ day mg/l -

Monthly 15 2.0 4/3/96 1

lbs/ day GRAB Avg 84

< 0.58 05:15 pm J

Daily 20 20 4/3/96 and mg/l GRAB Oil Ibsiday Avg 110

< 1.03 05:15 pm i-mg/l inst 20 2.0 N3/96 '

GRAB lbs/ day Max 110

< 1.03 05:15 p n 4

h i

a

.[

I t

f E

ISouthern California-Edison' Monthly Roport Pagn 17 of 17

' Facility :

Songs Unit 3-Exact Sample Point :

Point of -

Order No :

94-50 Discharge

. Report Freq~ :

Monthly Collected By :

Songs Envir Grp Report For :

April 1996 Analyzed By :

Son s c try Report Due :

May 30,1996

- Signed :

5 o

(

4 Waste Stream : Sewage Treatment Title :

Environmental $ngineer Daily Max Monthly Ava Sample ~ Date/ Time Sample Req't Sample

~ Req

- Units

. Type of Sample Value Value Value Value -

i i

Sewane -- Unit I i

593.0 i

inf mg/l

'09:25 593.0 j

- T.S.S -

Ibs/ day GRAB. 4/11/96 217.6 118.7 EFF mg/l 10:00 6.3 75 6.3 25:

GRAB GEO lbs/ day 4/9/96 2.3 63 1.3 21 EFF mg/

09:15 11.7 213.0 10.2 180.8 l

GRAB l

T.S.S lbs/ day 4/18/96 4.3 129.7 2.0 81.4 i

4 f-ml/l GRAB 0.2 3.0 0.1 1.0 5 96 h'

pH '-

Units GRAB 4/24/96 6.8 6.0 - 9.0 7.2 6.0 - 9. 0 i

i Turbidity NTU GRAB 4/9/96 17.2 225 17.2 75 h

Sewane -- Mesa Inf mg/l -

l T.S.S lbs/ day GRAB

EFF mg/l 75 25 G&O lbs/ day GRAB l

63 21 EFF mg/l 0.0 0.0 T.S.S lbs/ day GRAB 0.0 0.0

. sett, Solids ml/l GRAB 3.0 1.0 PH Units GRAB 6.0 - 9.0 6.0 - 9.0 i

Turbidity NTU

' GRAB 225 75 e MESA SEWAGE TREATED'AT.THE UNIT'1 SEWAGE TREATMENT PLANT

~ DISCHARGED.TO UNIT-1 OUTFALL

-