Forwards Suppl 2 to BAW-2127, Fatigue Stress Analysis of Surge Line Elbows, in Response to Open Item in NRC SER on BAW-2127 Dtd 910724.Rept Serves to Closeout Last Open Item in SER Re Issues of GL 88-11
ML20115B449
Person / Time
Site: Crane 
Issue date: 10/12/1992
From: Broughton T
GENERAL PUBLIC UTILITIES CORP.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
C311-92-2120, GL-88-11, NUDOCS 9210160077
Download: ML20115B449 (1)


Text

. _ _ _ _..

GPU Nuclest Corporation

.. *ti. Nuclear

~i o"- ~

Route 441 South

%ddletown, Penr'sylvania 17057 0191 717 944 7621 TELEX 84 2386 Weiter's Direct Dial Number:

(717) 948-8005 October 12, 1992 C311-92-2170 U. S Nuclear Regulatory Commission Attn:

Document Control Desk Washingten, D.C.

20555

Dear Sir:

Subject:

Three Mile Island Nuclear Station, Unit 1 (lMI-1)

Operating License No. DPR 50, Docket No. 50-289 Submittal of BAW 2127, Supplement 2 Fatigue Stress Analysis of the Surge Line Elbows Reference B&W Owner's Group Letter dated June 11, 1992 (Letter No. 0G-1048) submittal in response to the SER for Topical Report BAW-2127 and Generic Letter 88-11 The referenced B&W Owners Group letter transmitted to Mr. Joe Shea, USNRC Lead Project Manager (MPA X 811) - Project Directorate 1-2, the subject Supplement 2 to B&W's Topical Report BAW-2127.

The Supplement responds to the open itea concerning surge line elbows as contained in the NRC Safety Analysis Report (SER) on BAW-2127, dated July 24, 1991.

GPUN has reviewed the subject document and finds that B&W report, Supplement 2, is applicable to TMI-1.

Hence it is transmitted herewith for the purpose of docketing ano serves to close out the last open item in the SER pertaining to the issues of GL 88-11.

Sincerely, k

?,G. Bro'dhton Vice President and Director, TMI-l GMG

Enclosure:

1) B&W Owners Group _BAW-2127, Supplement 2, dated May 1992 cc: TMI-l Senior Project Manager Region I Aditinistrator TMI Senior Resident Inspector

$0%$$N b 9

b I

P GPU Nuclear Corporation is a subsidiary of General Pubbc U% tie Corporation

  • c ? OWNERS GROUP o

kasnsas Power i Light Canpany ANO.I Oske P6*er Car'pany Oconeet.2,3

'r Sacrarnento Municipa? Utility Destrict Rancho Seco Flor,da Power Cwporstoon Crystat Mer 3 fm W.a.

Tennessee b' alley Authority Bettelonte 1. 3 TulMo (dison Cattany a

Cano Besse CPU Nuclear Corgantion TLet.t B& W Nucles* Technologoes Working Together to Economically Provide Reliable and Safe Electncal Power Swte 525 e 1700 RocAville P:Ae e Rockville, MD 20852 e (301) 230 2100 1

June 11, 1992 OG-1048 gA JUN 1 6 1992 U.S. Nuclear Regulat.ory Commission 1 White Flint North 11555 Rockville Pike Rockville, MD 20852 Attention:

Mr. Joe Shea Lead Project Manager, MPA X-811 Project Directorate I-2 Division of Reactor Projects - I/II

Subject:

Safety Analysis Report (SER) for BAW-2127.

References:

1.

B&W Owners Group Report, " Final Submittal Pressurizer Surge Lino Thermal Stratification", BAW-2127, Deccmber, 1990.

2.

NRC Letter Dated July 24, 1991, From:

J.

Shea, To:

J.

Taylor,

Subject:

Pressurizer l

Surge Line Thermal Stratification (SER to BAW-2127) 3.

NRC / B&WOG Meeting held in Lynchburg, VA on January 15, 1992.

Daar Mr. Shea:

In response to the open item in the reference 2 SER, please find enclosed five (5) copies of the B&W Owners Group Summary report for the Fatigue Stress Analysis of the Surge Line Elbows.

is supplement 2 to the reference 1 topical report.

This report Also please find attached a copy of Appendices A-1, A-2, A-5, A-7, and A-8 of B&W Nuclear Technologies (bnNT) Document 32-1206920-00.

These appendices provide the detailed information requested at the reference 3 meeting.

Please note that these Appendices are stamped BWNT Proprietary and should be handled as such.

An affidavit supporting the proprietary classification is attached t.o this letter.

The reference 1 report and the appropriate supplements

...[

= l ~ ~ ~~

~

.~

_ = _ _ -. _ - -. _ _. _ _ - _ _.

.a o

Mr. J.Shea, NRC OG-1048 June 11,1992 2

provide the non-proprietary information contained in the proprietary appendices.

Therefore, no we do not plan to submit any addit.ional non proprietary information.

Should you require any further information, please contact me at 4

(813) 866-4414, The B&W owners Group Project Manager, A.

W.

Robinson at (804) 385-3290, or the B&W Owners Group, Thermal Stratification Working Group Chairman, G. L. Lehmann, at (201) 316-7052.

i Very T u

urs, D.

N. Miskiewicz, Chairman B&WOG Materials Committeo DNM/AWR Attachment l

cc:

T.

L.

Chan

- USNRC (w/2 copies)

H.

K.

Shaw

- USNRC (w/2 copies)

R.

B.

Borsum

- BWNS 4

MAY 1992

-,ny,,,.,7_.g m,,,.7g,g7ga1ym,amm-,om-=m,r

. nn,em gygn w. m u m a = m 2.u m a c u a m _

m am_m.m.as 9

F G

1

,my,mmmm,y m,n, mmmmmeny--nr,,,nn,v

,,ww',:,

J G alatiaL % M ^hkMAL L lag 444Suda A N.x!A:24sO M b ilyduAith;Je untwiis au,M L W.A;4d h ush d sdihasa,a BAW-212 7 SUPPLEMENT 2 PRESSURIZER SURGE LINE THERMAL STRATIFICATION FOR THE B&W 177-FA NUCLEAR PLANTS

SUMMARY

REPORT FATIGUE STRESS ANALYSIS OF THE SURGE LINE ELiSOWS

\\

3;c r

~

,, ; c:x v l

Vg

,g lv!'?B&W NUCLEAR a LMESERVICE COMPANY ty L t-

.,.e s

3 j

. 7.

4 1

l

BAW-2127 SUPPLEMENT 2 MAY 1992 j

l l

J l

I i

l PRESSURIZER SVRGE LINE l

l THERMAL STRATIFICATION j

FOR THE B&W 177-FA NUCLEAP PLANTS l

SUMMARY

REPORT l

FATIGUE STRESS ANALYSIS OF THE SVRGE LINE ELB0WS i

4 i

Prepared for Arkansas Power and Light Company Duke Power Company l

Florida Power Corporation General Public Utilities Nuclear Toledo Edisen Company i

i B&W Nuclear Service Company P.O. Box 10935 Lynchburg, Virginia 24506-0935 I

e

--,.,.ge--

n-y,mg,,upgaar e

,n.

,m,-,-.,--

-m.,,--.--r_,.

y

,e,--y,,--

-e,---,. -

,__s.--

,w,,

,r..--,m..

EXECUTIVE

SUMMARY

Purpose:

The purpose of this supplement is to report on the re-evaluation of the pressurizer surge line elbow; fatigee usage in order to close out the Nuclear Regulatory Commission Safety Evaluation Repor+ (SER) open item on BAW-2127 (Reference 13).

Backaround:

On December 20, 1988, the Nuclear Regulatory Commission issued NRC Bulletin 88-11.

The bulletin addressed technical concerns associated with thermal stratification in the pressurizer surge line and required utilities to establish and implement a program to ensure the structural integrity of the sarge line.

The B&W Owners Group has developed a comprehensive program to addren the requirements of the bulletin. This program and its results were summarized in BAW 2127, Final Submittal for Nuclear Reaulatory Commission Bulletin 8. Ell

" Pressurizer Surae line Thermal Stratifict1100"., for the B&W-designed lowered loop plants, in September 1991, Supplement 1, Elant-Soecific Analysis in Response to Nuclear Reaulatory Commission Bulletin 88-11 " Pressurizer Surae line Thermal Straufication" Davis-Besse Nuclear Power Station Unit 1, presented the results for the B&W-designed raised loop plant.

The Nuclear Regulatory Commission Safety Evaluation Report (Refer 9..ce 13) on BAW-2127 found the methodology used to analyze and evalu-+e the. tress and fatigue effects due to thermal stratification and thermal striping acceptable with one exception.

The NRC staff and its consul', ant disagreed with the B&W interpretation of the secondary stress index (C ) for elbows, thus, leaving the 2

fatigue usage of the elbows as an open-item to be resolved.

-ii-i

= _ -

i j

4 i

Summary:

1 A re evaluation of the surge line elbows was performed using the Code table l

stress indices for elbows. The surge line was reevaluated to include shakedown, 2

as described in NB 3228.4 of the ASME Code, and strain based fatigue of the surge line elbows.

4 Detailed finite element analyses were performed on the lin.iting portions- (the elbows) of the surge line piping, as well as on the entire surge line to demonstrate shaked(,wn. Shakedown was demonstrated to occur within 3 to 4 cycles and resulted in a maximum accumulated local straia-of 1.07% compared to the 5.0%

of ASME Code Cases N-47-28 and N-196 1.

The fatigue usage for all surge line elbows was demonstrated to be less than 0.6 over the 40 year design life of the B&W 177 fuel assembly plants. Thus, at all surge line locations the 40 year cumulative fatigue usage factor remains less

{

than the Code allowable-fatigue usage factor of 1.0

==

Conclusion:==

i Having previously demonstrated the fatigue usage-of the nozzles and piping to be acceptable, excluding the elbows, and having demonstrated the~a;ceptability of the elbows in this supplement, the B&WOG response to NRC Bulletin 8811 is complete.

l I

i v

-iii.

0

TABLE OF CONTENTS EXECUTIVE

SUMMARY

.......................... g 1.

INTRODUCTION 11 1.1 Background........................

1-2 1.2 Conclusion........................

1-4 2.

SHAKEDOWN ANALYSIS 2-1 2.1 Generalities.......................

2-1 2.2 Shakedown Options 2-1 2.3 Verification of Shakedown by Elastic Plastic Analysis 22 2.4 Verification of Shakedown by Use of the Bree Diagram (l owered-loop pl ant s)...................

2-9 2.5 Verification of Snakedown for Davis-Besse Unit 1 Surge Line........................

2-9 3.

FATIGUE ANALYSIS 3-1 3.1 Generalities.......................

3-1 3.2 Factors Contributing to Fatigue 3-1 3.3 Shakedown Fatigue 3-2 3.4 Post-Shakedown Fat'gue..................

3-3 3.5 Input Stress-Strain Curve for Post-Shakedown Fatigue...

3-3 3.6 Strain Correlations for Post-Shakedown Fatigue......

3-4 3.7 Elbow Fatigue Analysis Results..............

35 4.

SUMMARY

OF RESULTS 4-1

5. REFERENCES 5-1
6. DOCUMENT SIGNATURES.......................

6-1 ATTACHMENT A:

Section 111, Division 1, NB 3228.4 Code Inquiry and Response (pages A-1 through A-4)

-iv-

LIST OF TABLES Tabie Epsg 1-1 Overview of the Highest Total Cumulative Usage Factors in the Surge Line of the Seven B&W 177-FA Nuciser Plants..... 1-6 31 Total Cumulative Usage Factors for the Surge Line Elbows 3-6 t

41 Total Cumulative Usage Factors for the Surge Line Elbows 4-2 LIST OF FIGURES Fiqure P_itqe 21 PV# 4 X Displacement..................... 2-5 2-2 PV# 4 Y-Displacement..................... 2-6 2-3 PV# 4 Z-Di s pl acement..................... 2-7 3-1 Surge Line Mathematical Model................. 3-7 3-2 Surge Line Mathematical Model................. 38 i

-v-

1.

INTRODUCTION This document is a supplement to B&WOG Topical Report BAW 2127, Final Submittal for Ntelear Reaulatory Commission Bulletin 88-11 " Pressurizer Surce line Thermal Stratification" (Reference 1). The analyses described in this supolement confirm that all surge line elbows satisfy applicable ASME Code stress allowables for the operating B&W lowered and raised loop plants, considering the effects of thermal stratificatiori and thermal striping.

This introduction briefly reiterates the background for the thermal stratification, striping and cycling issues, and provides a summary of the pressurizer surge line fatigue analysis results and conclusions contained within Reference I which address the technical issues described in NRO dulletin 88-11 (Reference 2).

The remaining sections of this supplement are as follows:

6 Section 2 discusses the shakedown analysis performed, and provides a brief justification for the use of the ARAQUS finite element code, 6

Section 3 discusses the fatigue analysis performed, 6

Section 4 provides summary results of the shakedown and fatigue evaluation of the surge line elbows, as well as the conclusion regarding the integrity of the entire pressurizer surge line, and e

Section 5 lists all references.

1-1

1.1 Backaround The surge line in B&W 177 fuel assembly (177-FA) plants is approximately 50 feet of piping which connects the pressurizer lower head and the reactor coolant hot leg piping.

During plant operation, the reactor coolant system (RCS) is pressurized with a steam bubble in the pressurizer.

Thus, the pressurizer contains saturated fluid while the remainder of the RCS is subcooled with temperatures cooler than the pressurizer fluid. During normal plant operation, this temperature difference is less than 50'F. However, during plant heatup and cooldown conditions, the temperature differeate can be much higher.

The surge line is the fluid flow path through which the pressurizer accommodates changes in RCS liquid volume, When the reactor coolant pumps are operating, there is normally a small outflow from the pressurizer due to continuous pressurizer spray flow through the spray bypass line. During plant heatup and cooldown conditions the surge line accommodates a significant number of fluid exchanges between the pressurizer and RCS.

Due to differences in density, the fluid temperature can vary in the horizontal surge line piping sections from top to bottom with the warmer fluid located above the more dense (cooler) fluid. This phenomenon, known as thermal stratification, is most pronounced during outsurges from the pressurizer. During an insurge or outsurge under stratified conditions, thermal striping may occur at the fluid layer interface. Thermal striping is a rapid oscillation of the thermal boundary interface caused by interfacial waves and turbulence effects. The original plant design fatigue analyses did not acccunt for thermal :.tratification cycles in the pressurizer surge line, which causes additional bending moments in the piping, nor did the analyses account for thermal striping which affects the fatigue usage at the inner surface of the pipe.

[

To assure pressurizer surge line integrity for the 40 year design life of oressurized water reactors (PWRs), the 4 -lear Regulatory Commission issued NRC Bulletin Number 88-11, Pressurizer Surae Line Thermal Stratification (December 20,1988). This bulletin requira certain actions of licensees of all operating pressurized water reactors.

The applicable actions are paraphrased below:

1-2

_.hh

la.

At the first available cold shutdown after receipt of the bulletin, and which exceeds seven days, conduct a visual inspection of the pressurizer surge line.

b.

Within four months of receipt of the bulletin, licensees of plants in operation over ten years are requested to demonstrate that the pressurizer surge line meets the applicable design codes and other FSAR and regulatory s

commitmerts for the licensed life of the plant, considering thermal stratification and thermal striping in the fatigue and stress evaluations; or provide the staff with a justification.for continued operation while a detailed analysis of the surge line is performed that implements items Ic and Id below.

Ic.

If necessary, obtain plant specific surge line. thermal and displacement data.

Data can be obtained through collective efforts if sufficient similarities in geometry and operation can be demonstrated.

Id.

Update the fatigue and stress analyses to ensure compliance with the applicable Code and Regulatory requirements within two years of receipt of the Builetin or submit a justification for continued operation and a oescrip'. ion of the proposed corrective actions for effecting it.ig-term resolution.

l4 portion of the B&W Owners Group program was presented to the Nuclear Regulatory Commission Staff on September 29, 1988 and April 7,1989. An interim evaluation, BAW-2085, dated May 1989, provided the staff with a justification for near term operation for all of the operating B&W 177-FA plants (Reference 3).

The NRC concluded that sufficient informhtion had been provided to justify near term operation for B&W plants until the final report could be completed (References 4 and 15).

The final report for the lowered loop plants was completed and submitted to the NRC in Dece^er 1990 (Reference 1). Supplement I to this report, describing the plant-specific analysis and providing a basis for a Justification for Continued 1-3 i

Orcration (JCO) for the raised loop Davis-Besse Unit 1 plant, was submitted to the NRC in September 1991 (Reference 7). This report used the same methodology applied in Reference 1.

Questions from the NRC, regarding these methods and the applied analysis, were answered by Reference 11.

The NRC SER, based on the lowered loop plant final report (Reference 1),

contained an open item regarding the analytical technique used to demonstrate acceptable integrity of the surge line elbows. A similar oper item was included in the NRC acceptance of the JC0 for Davis-Besse Unit 1 (Reference 12).

As a result, the B&WOG performed a shakedown analysis of the surge line and a strain based fatigue analysis of all surge line elbows.

The preliminary results were presented to the NRC at a meeting with the B&W Owners Group Thermal Stratification Working Group on January 15, 1992. This second supplement to BAW-2127 summarizes the results from these analyses to demonstrate the integrity of the surge line elbows in order to resolve the NRC open item.

Only those B&W Owners Group program aspects directly contributing to the surge line shakedown and elbow fatigue are considered herein.

All other program aspects and general methodologies, including the thermal loading conditions (thermal stratification peaks and vall eys, thermal striping, fluid flow conditions), remain unchanged from the original BAW-2127 and BAW-P.127 Supplement 1 (References 1 and 7).

The Reference 11 response (Responses to Nuclear Reoulatory Commission Ouest Ms), regarding earthquake combinations, remains unchanged as a result of this supplement.

1.2 Conclusion l

The limits on thermal stress ratchet (NB-3222.5), progressive distortion (NB-1 3227.3), local membrane stress (NB-3221.2), prinary plus secondary stress intensity (NB 3222.3) and expansion stress intensity (NB-3222.3)' need not be satisfied at a specific location if a shakedown analysis satisfying the requirements of NB 32?8.4 is performed.

Such an analysis has shown that shakedown of the surge line is achieved within a few cycles and the maximum accumulated local strain is well below ASME Code Case allowables (References 9 and 10). The response to an ASME-Code Inquiry (Attachment A and Reference 14) 1-4

l has confirmed that the thermal expansion stress criterion of NB 3222.3 does not need to be satisfied since shakeduwn has been demonstrated in accordance with NB-3228.4(b).

i All operating lowered loop plants have been shown to have acceptable cumulative 1

fatigue usage for the full 40 year licensed plant life.

Similarly, the elbow i

fatigue usage factors for Davis-Besse Unit 1, the only operating raised loop plant, are within the allowable limit of 1.0 for the licensed 40 year plant lifetime based on the design transients defined in BAW-2127, Supplement 1 (Reference 7).

In all cases, the structural analysis of the surge line has accounted for the thermal conditions (thermal stratification, thermal striping, and thermal cycling) which are expected to occur during the 40 year life of the plant.

Table 1 1 gives an overview of the highest Total Cumulative Usage Factors in the Surge Line tf the seven B&W 177-FA nuclear plants. These factors are based on 240

{

heatup and cooldown cycles ovet the 40 year design life for all the plants except i

for the three Oconee Units which are based on 360 heatup/cooldown cycles over the l

40 year design life.

The Nuclear Regulatory Cominission has approved operation of Davis-Besse Unit 1 through the 9th operating cycle based upon a Justification for Continued Operation submitted in September, 1991 (Reference 12).

An updated cumulative fatigue usage factor for Davis-Besse Unit 1, considering the modifications to be completed prior to restart from the 9th refueling outage, will be provided at a l

later date.

f J

,L

'f 1-5 l

-..,n

- + -

v

l TABLE l-1.

Overview of the Hiahest Total Cumulative Usaae f actors in the Surag Line of the Seven B5W 177-FA Nuclear Plants.

< - - - - - - - - - - As P rev i ou sl y Repo rt ed -- -- - - ---- - - - >< --- Rev i sed -- >

Nuclear Pressurizer Surge Line to Surge Line Surge Line Plants.

Surge Nozzle Hot leg Nozzle Non Elbow Elbows L^ cations Oconee 0.40 0.59 0.48 0.49 Unit 1 Oconee 0.41 0.59

0. ',8 0.50 Unit 2 THI 0.33 0.62 0.38 0.40 i

Unit 1 C.R.

0.32 0.62 0.37 0.40 Unit 3 AND 0.32 0.62 0.38 0.40 Unit 1 Oconee 0.41 0.59 0.47 0.48 Unit 3 Davis-0.93 0.76 0.61 0.59 Besse Unit 1 (Note 1)

(Note 1)

(Note 1)

(Note 2)

Notes relative to Davis-Besse Unit 1 surae line:

Note 1:

All of these usage factors assumed certain modifications including the surge line support whip restraints and thermal insulation during the 7th refueling outage.

Additional analyses have been performed to show that the cumulative usage factors up to the 9th refueling outage (without completion of modifications) are well within the allowable limit of 1.0.

Note 2:

The usage factors for the elbows are for a 40 year plant life, and consider the committed modifications including the spring support and pipe whip restraints during the 9th refueling outage to assure unrestricted motion of the surge line.

General Davis-Bosse Note:

The NRC Staff concluded (Reference 12) that continued operation of Davis-Besse Unit 1 is acceptacle through the 9th refueling outage pending final resolution of the pressurizer surge line stratification items which should be completed by the end of the 8th refueling outage, if possible.

1-6

i 4

i ll 2.

SHAKEDOWN ANALYSIS l

11 Generalities The shakedown analysis has been performed to satisfy the ASME Code (Reference 6) via use of NB-3228.4, which replaces the requirements of NB 3653.6(a) and/or dB-3222.3 Thermal Expansion Stress intensity. The response to an ASME Code Inquiry (Reference 14) has confirn.ed that the thermal expansion stress criterion of NB-3222.3 does not need to be satisfied if shakedown can be demonstrated in accordance with NB 3228.4(b).

NB 3213.34 of the ASME Code, Reference 6, defines shakedown as follows:

" Shakedown of a structure occurs if, af ter a few cycles of load application, ratcheting ceases. The subsequent structural response is

elastic, or elastic plastic, and progressive incremental inelastic deformation is absent.

Elastic shakedown is the case in which the subsequent response is elastic."

2.2 Shakedown Ontioni Shakedown of the surge line nas been demonstrated using two methods. The most sophisticated method is the elastic-plastic analysis of the entire surge line piping system.

The second method utilized the Bree-Diagram for the surge line location which experiences the largest strain.

Since the Bree-Diagram only appears in the high-temperature Code Case N-47-28 (Reference 9), both the Bree-Diagram and the more sophisticated elastic-plastic analysis were used.

In this elastic-plastic analysis, the surge line was analyzed as a system (surge line modeled from the pressurizer to the hot leg) with elastic-plastic properties for all elbows. This model was loaded with the 2-1 J

I most severe cyclic loads until shakedown was reached.

The elastic-plastic shakedown analysis is described in Sub-sections 2.3 through 2.6.

The Bree-Diagram method was also used for the most severe elbow and cyclic loads (see Sub-sections 2.4 and 2.5).

2.3 Verification of Shakedown by Elastic-Plastic Analysif

~ 3.1 Input Stress-Strain Curves Stress-strain curves (for austenitic stainless steel material) were developed for

150F, 300F, and 450 F and employed kinematic hardening for the

" loading / unloading" behavior. These were the temperaturrs corresponding to the thermal conditions of the surge line for the most severe cyclic loads (Reference

1) to be applied in the elastic-plastic shakedown analyr.is. These stress-strain I

curves have been developed using the general equations.:

stress a - E

  • t in the purely clastic domain, ar.d stress o - K * (" in the elastic-plastic domaire, where t is the total strain value, and the exponent a is approximately equal to 0.3 for stainless steels These stress-strain curves are based on the following values from the ASI (Reference 6):

the modulus of elasticity, E, the yield stress, Sy (at

.2%

I offset), and the ultimate tensile stress, Su.

2.3.2 Inout Lead.ji d

The most severe thermal stratification ranges for the shakedown analysis have been defined in the previous fatigue evaluation of the surge line based on the operating design transient information (Reference 1).

These transients were devConed to conservat'vely reflect past operation.

The most severe stress loading range, as identified in BAW-2127 (Reference 1) fatigue evaluation, was betuen the highly stressed Feak, PV4 of HulAl heatup (top to bottom temperature difference of M3 F while the pressure is 578 psi.), and nominally stressed Valley, P/402 of CDIBl cooldown (top to bottom temperature difference of 12 F R

while the pressure is 379 psi.). This severe hypothetical stress load range was specified for 13 design cycles.

These 13 cycles envelope the number of 2-2 I

occurrences for all lowered loop plants.

Therefore, the shakedown analysis cW bd this load cycle 13 times, using the following cyclic loading map:

l PV No.4 / PV No.402 / PV No.4 / PV No.402 / PV No.4 /-PV No.402, etc...

The concurrent thermal expansion, thermal stratification, internal pressure, and deadweight were simultaneously loaded on the surge line for each Peak or Valley condition.

The model included the anchor motions resulting from the thermal expansion of the pressurizer and RCS hot leg.

1 3.3 Use of ABA0VS Finite Element Code The ABAQUS finite element code was utilized in constructin', a r' 11 of the surge I

line to perform the shakedown analys :-

"1AQUS (Ref:rence 8), developed by Hibbitt, Karlsson and Sorensen, Inc., is specifically designed for advanced structural analysis. These applications include nonlinear effects which dominate the overall program design. ABAQUS development started'early in !??8. Electric Power Research Institute developmental funding has resulted in the implementation of capabilities that are generally useful in structural integrity evaluations of nuclear components.

~

Piping sy; tem design rellas heavily on the use of elbows.

This allows extra flexibility in the line to accommodate thermal loading.

Therefore, the elbows themselves are the critical design components.

it is essential to accurately predict their response in order to structurally qualify a pipeline.

Ir, the plastic regime, piping elbows achieve their flexibility through a shell-type-behavior, responding to bending loads with significant ovalization of the phe cross-section. In contrast, the straight pipe cross-section does not deform to any significant extent until Brazier buckling occurs.

The elbow elements of ABAQU s are intended for piping applications wherein nonlincar effects ' associated with ovalization and warping must be included. The elbow elements use a combint'. ion of polynomial interpolation along the axis of the pipe and Fourier interpolation around the circumference of the pipe.

The elements contain nine irtegration points through the thickness and twenty-four 2-3

l l

a around the cross-section. The elbow elements of ABAQUS have been experimentally verified and lend themselves well to the shakedown analysis sumtrr ized in this document.

The ABAQUS shakedown model has been verified by comparison with the ANSYS l

mathematical model of the surge line (Reference 1), which was bench-marked' to actual surge line displacements measured during the Oconee Unit 1, February,1989 heat-up. To demonstrate that the ABAQUS model yielded comparable displacements, this verification was performed using two purely elastic computer analyses: the 100% power thermal expansion load case and the most severe thermal stratification condition, Peak PV4 of HU1 A1 heat-up.

For both load cases, the surge line displacements using ABAQUS cgreed with the ones using ANSYS. Figures 2-1 through 2-3 show the results of the comparison between the displacements for the Peek PV4 load case.

i l

l f

u 2-4 1

=

0 5

t I

04 f N

r

~

e z

t i

n r

e 0

u 1

m I

3 s

e s

c e

U S

2 a

r O

I P

A p

B E

s m

A R

I 2

r S

i D

0 o

U Y

f S

G X

N e

A I

4 c

F n

tt a

V t

P I

0 s

1 i

D e

O e

6 4

2 0

2 4

o 0

0 0

0 O

aC m U a o_ m.-

c i

7w

F IGURE 2-2 PV# 4 Y-Displacement 2

~

r c

1 9

i i

+J C

O f~

>=w~,

e

~

9 l

b, C

%f.

O.

W _1 O

\\

I I

I I

I

-2 O

10 20 30 40 50 Distance from Pressurizer, ft.

ANSYS ABAOUS e

O i

tapP L.. _ _.. _ _ _. _ _.

F I GURE 2-3 PVlt 4 Z-DispIacement l

1 0.s 0.4 c

, 0.2 a

C

U i

V j'

a E-0.2 g

.7 l

- 0. 4

-0.6 I

I I

I O

10 20 30 40 50 Distance from Pressurizer, ft ANSYS ABAOtJS l

e_

_c f.

l 2 3.4 Shakedown Analysis Results

-l Shakedown has been demonstrated for the most severe ranges of thermal stratification conditions (Peaks and Valleys) based on the following results evaluated at the location of maximum plastic strain (within each elbow):

4 a.)

Stress-strain Hysteresis and Stability Check b.)

Maximum Accumulated Local Strain developed through Shakedown

' ~

c.)

Strain Range per complete cycle (used in Fatigue Analysis) 4 -

l A.)

Stress-strain Hysteresis Results l

The stress-strain hysteresis was stable after 3 to 4 cycles of leading and unloading.

(

B,)

Maximum Accumulated local Strain Results The maximum accumulated local strain was the maximum peak strain developed during the shakedown analysis. The resulting maximum accumulated local strain occurred l

at the peak stratification, PV4, and was 1.C1% for the most critical elbow (Figure 3-1, Elbow B at the bottom of the riser).

1 i

Code cases N-47-28, approved July 27,1988, Appendix T (Reference 9), and N-196-1, approved January 21, 1982, Condition No. 2 (Reference 10) provide a. maximum allowable accumulated local strain of 5.0%.

These Code cases define the applicability of this maximum allowable accumulated local: strain to any plastically analyzed location at which the calculated local strain is the result of cyclic operations.

The maximum accumulated local strain 'anywhere in the shakedown model of the' surge line was 1.07% (1.07% u 5.0%).

Therefore, the maximum accumulated local strain from the shakedown analysis is acceptable.

C.)

Strain Rance Per Complete Cycle Results Shakedown occurred within three to four load cycles.

After shakedown, the resulting strain range at the most critical elbow (Elbow B at the bottom of the riser) was 0.759%.

i 2-8 i

- -,. -,. - - - ~.., ~. - -. _. -,...,. - -. -._

L r

l 2.4 Verification of Shakedown by Use of the Bree Diaoram flowered-loon plants)

Shakedown has been demonstrated for the most severe cyclic loads which lead to distortion.

The most severe cyclic loads have been defined in the previous fatigue evaluation of the surge line (Reference 1). In the most severe heat-up to be analyzed (associated with early plant life operation), the primary stress effects due to internal pressure become significant only at the end of inis heat-up.

At that time, the most severe thermal stratification peak stresses (which occur at the beginning of the heat-up) have been established and have shaken down. A Etee Diagram has been built for the surge line location undergoing the largest strain.

On this Bree Diagram, the most severe thermal stratification cyclic loads (analyzed in the elastic-plastic shakedown analysis) have been shown to be the controlling conditions for shakedown when compared to other conditions during the same heatup transient. Also, on the same Bree Diagram, all of the stress points corresponding to the thermal stratification Peaks have been shown to be acceptable. This again demonstrates that shakedown has occurred in the surge line.

2.5 Verification of Shakedown for Davis-Besse Unit 1 Surae line A separate analysis to demonstrate shakedown of the Davis-Besse (raised loop plant) pressurizer surge line was not performed. The following is justification that the shakedown analysis reselts for the lowered loop plants provides bounding results for the Davis-Besse raised loop plant.

The lowered and raised loop surge lines have the same pipe size (10 itch, l

schedule 140) and the same material, with similar length and flexibility. Based or BAW-2127 and BAW-2127 Supplement No.1 (References 1 and 7), the most severe thermal bending stress range (equation 12) for the Davis-Besse surge iine was less than that of tN lowered loop plants. The ratio of elbow in-plane to out-of-plane moment was also lower for Davis-Besse.

Therefore, the plastic strain I

results in the Davis-Besse surge line elbows would be lower than the results from the analyzed lowered loop plant. This has been illustrated on a Bree diagram, where the e.orresponding thermal stratification peaks for the most severe Davis-Besse surge line heatup transient were lower than those analyzed in the elastic-plastic shakedown analysis of the lowered loop plant surge lines.

Thus, the 2-9

lowered loop plants provide a conservative demonstration of the shakedown for the Davis-Besse surge line, t

e a

)

i i

i f

4 E

I 1

4 t

2-10 I

m J

3.

FATIGUE ANALYSIS 3.1 Generalities The total cumulative fatigue usage calculated in References 1 and 7 consisted of the sum of:

1) Main Fatigue Usage (Shakedown and Post-Shakedown Fatigue) and
2) Additional Fatigue Usage (Items 3, 4, and 5 of Sub-section 3.2).

Or.ly the main fatigue usage for cycles with Equation 10 Stress-Range Intensity greater than the Code 3*Sm limit was recalculated for this analysis. All other fatigue usage values remained unchanged from References 1 and 7.

For Equation 10 Stress Ranges exceeding 3*Sm, fatigue was recalculated using the cyclic strain range as a function of the moment and pressure terms along with a strain based penalty factor applied to the additional peak stresses of that cycle.

3.2 Factors Contributino to Fatioue C

The total cumulative usage factor is equal to the sum of the following fatigue cont;-ibutions:

1.)

-Shakadown Fatigue (see Sub-section 3.3).

2.)

Post-Shakedown Fatigue (see Sub-section 3.4) of:-

a.)

Stratified Ranges Failing Equation 10, thus Recalculated b.)

Stratified Ranges-Passing Equation 10, thus No Recalculation c.)

'Non-Stratified Ranges

-Passing Equation 10, thus No Recalculation 3.)

Fatigue Usage for the non-stratified High Velocity Fluid Flow conditions.

4.)

Thermal Striping Fatigue by itself.

5.)

Fatigue Usage for the remaining Operating Basis Earthquake Ranges.

3-1 4

Only those contributions designated by Items 1. and 2a. (listed above) were recalculated.

All other fatigue contributions meet Code Equation 10 and correspond to the original BAW-2127 and BAW-2127 Supplement 1 (Reference 1 and Reference 7).

3.3 Shakedown Fatique for the most sever? thermal stratification ranges (PV No.4 - PV No.402) analyzed in the ABAQUS shakedown analysis, the total elastic-plastic strain range occurring between the maximum Peak (PV4) and the minimum Valley (PV402) was retained. The purely elastic strain range for the thermal stratification cycle PV4-PV402 was also calculated in an elastic structural analysis of the surge line mathematical model, and the corresponding Kpp penalty factor (elastic-plastic strain divided by the purely elastic strain) was calculated.

Using the total elastic-plastic strain range (for PV4-PV402) and the corresponding Kpp penalty factor, the alternating stress, S,n, was calculated using the equation below.

S, a =

  • (E

= strain range +

. K, = additional peak stress )

7y g

where Kpp was the plastic penalty factor, and the additional peak stress was the combination of the peak stresses due to fluid flow (through-wall thermal gradients), thermal striping, and the non-linearity of the temperature profile (combination as performed in Reference 1).

The shakedown fatigue from the resulting alternating stress was performed to retain consistency between the shakedown analysis and the fatigue analysis, even though the ASME Code only requires the post-shakedown strain ranges to be considered (NB-3228.4(c)]. The shakedown fatigue was also included in response to NRC comments during the January 15, 1992 meeting with the B&W Owners Group Thermal Stratification Working Group.

i 3-2 J

F

.__________.______________m.

3.4 Post-Shakedown Fatiaue In the Post-Shakedown-Fatigue, the calculation-of the alternating stress S,n results from the same formula given in Sub-section 3.3:

S,a =

  • (Em
  • strain range +
  • K,
  • additional peak stress )

average The values for the strain range and the plastic penalty factor, Kpp (elastic-plastic strain divided by the purely elastic strain), were calculated through a detailed finite element ABAQUS elbow model, The additional peak stress was the combinttion of the peak stresses due to fluid 'l ow (through-wail thermal gradients), thermal-striping, and the non-linearity of the temperature profile (combination as performed in Referer.ce 1).

.I For the thermal stratification ranges which meet Equation 10 Stress Range Intensity of the ASME-Code (within the 3*Sm allowable), the alternating stress values and the usage factors are calculated using the simplified equations of the ASME-Code.

3.5 Inout Stress-Strain Curve for Post-Shakedown Fatique.

For each thermal stratification cycle, the temperature of interest is the mean value of the temperature during the cycle (see NB-3222.5 and NB-3228.4(c)]. This mean value has been found to be 300*F or less, depending on the location of the elbow analyzed. Therefore, the applicable stress-strain urve will be taken at 300'F in the finite element elastic-plastic analysis of the surge line elbow.

The input stress-strain data for the finite element elastic-plastic analysis of the elbow (Post-shakedown) are defined as follows: linear purely elastic regime up to 1.5

  • Sm (modulus of elasticity E from the ASME Code), and linear stress-strain relationship in the elastic-plastic regime intersecting the nonstrain-hardened stress-strain curves at the 1.0 % total strain location. This second 3-3

r slope is conservatively low in that no strain hardening is included for the stress at 1.0 % total strain.

Note that in the fatigue analysis, the moment ranges applied after shakedown on each one of the surge line elbows were calculated " purely elastically" in the structural analysis of the surge line.

Reduction of the moments due to plasticity in the elbows is not taken into account.

3.6 Strain Correlations for Post-Shakedown Fatiaue The ABAQUS surge line elbow finite-element model has been loaded by combinations of bending moments and internal pressure values (the internal pressure values considered are O psi., 600 psi., 1500 psi, and 2250 psi.).

From the different load c4 e highest strain value anywhere in the elbow was employed.

An analysis has = m performed to compare (for the same internal pressure values) the highest strain range due to a combined "in-plane opening

{

moment / in-plane closing moment" load case with the highest strain range due to "out-of-plane moment" in the elbow mid-section. From this analysis, it has been p

found that the "out-of-plane moment" load case leads to a lower value for the

]

highest strain range in the elbow. Therefore, using the "in-plane openin; moment i

/ in-plane closing moment" load case, correlation tables were built for the calculation of the highest strain range anywhere in the elbow as a function of the elastically calculated moment range and of the internal pressure in the elbow. Similarly, correlation tables were built for the plastic penalty factor Kpp to be applied on the additional peak stm es.

For each thermal stratification cycle, the strain range and the plastic penalty factor, Kpp, are calculated through a conse.vative linear interpolation betvaen values in the correlation tables mentioned above. Knowing this strain range and the corresponding Kpp value, the alternating stress is calculated using the formula given earlier in Sub-section 3.4.

I I

3-4 l

l 3.7 Elbow Fatiaue Analysis Results For the surge line elbows of the lowered loop plants, the highest 40-year total cumulative usage factor occurred in elbow B of Figure 3-1 (vertical elbow at the bottom of the surge line riser).

It was equal to 0.60 for Oconee Unit 2, 0.49 for Oconee Unit 1, 0.48 for Ocor.ee Unit 3, and 0.40 for TMI Unit 1, Crystal River j

Unit 3 and Arkansas Nuclear One Unit 1.

1 For the surge line elbows of Davis-Besse Unit 1, the shaktdown fatigue was based on the maximum strain range calculated in the surge line elbows of the lowered loop plants. The strain range.of the most highly stressed elbow in the lowered loop plants was conservatively applied to each elbow of the Davis-Besse Unit 1 pl ant. The remaining fatigue (post-shakedown) for Davis-Besse utilized Davis-Besse loads and the elastic-plastic finite element elbow results. T'iis resulted in a maximum total cumulative usage factor of 0.59. The naximum total cumulative i

usage factor for Davis-Besse Unit 1 occurred in the vertical elbow at the bottom of the pressurizer, els w A.

Table 3-1 on the following page gives the resulting Total Cumulative Usage Factors for all elbows (see Figure 3-1 and Figure 3-2) and highlights the maximum values for each plant.

i i

1 i

J l

3-5

7_. _. _. _. _ _... _ _. _

9 Elbow Fatiaue Analysis:

TABl.E 3-1.

TOTAL CUMULATIVE ~ USAGE FACTORS FOR THE SURGE LINE ELBOWS El bows===>

Elbow A Elbow B Elbow C -

Elbow D-Elbow E Oconee Uni + 1 0.13 0.49-0.34 0.38

does not i

(4 elbows) apply._

1

~

Oconee Unit 2 0.13 0.50 0.35 0.39 does not j -_

(4 elt]ws) apply.

t l

TMI Unit 1 0.10 0.40 0.29 0.33 does not (4 elbows) apply.

4.

l Cr. River Unit 3 0.10 0.40 0.29 0.33 does not (4 elbows) apply.

ANO Unit ~1 0.10 0.40 0.29 0.33 does not i_

(4 elbows) apply.

i Oconee Unit 3 0.13 0.'48

'O.33 0.38 does-not--

(4 elbows) apply.

Dcvis-Besse Unit 1 0.59 0.57-0.44-0.15 0.33 (5 elbows) 1 t

l t

i f

f 1

l 5

l-f

[

3-6 i

~..-,_._.3...__._,

Figure 3-1 Surge Line Mo theno titol Mode!

ELBOV A 3 2 e

5 HOT LEG 6

elements I througn 5 7

Jt 8 x = -55 0' j y y=

- 1.5 0 *

  • 8 Z: 248656' Z,/

9 e:ements N

/

13 througn 13 7

av 11

/

ELBOW B 12 34 90' j (Deo,n Nozzle X=

+ 53 0')

'1J i

5

/ for NS$$-3, 4 5 and 9 l

/

\\g 42 elements s

g g, g

f 23 througn 26

\\

I7

\\

N

\\'

\\

g 19 k

NSSS PLANT

\\

N 3

CCONEE 1 (X= 41.0 ')

20 4

DCONEE 2 OP C 'N NOZZIO NSSS-7 ond 8. \\ 21 5

TM! I for x

7 CR 3

~=g

/

8 AND 1 Ej#

9 OCONEE 3 ELBCV C C

25 26 Pressurizar etenents 29 through 32 27 52 / /

/ 2B 31 Q ELBOV D 3g 29 3-7

_ ~

t i

Figure 3-2 Surge Line Mathematical Model

__NSSS I PLANT i

ELBOW D 14 DB1 34 33 as I

37 PRESSURIZER

~31 as N

40 42 xQa y,,

w N'N'S b

ELBOW B HOT LEG N

13 12 11 g

10 47 N

y'

['N D

4 43

'f 53 I

l 15

/5 4S 51 52 50 4

16 8 7 6

28 17 90WA ELBOW E s

l

. 19.

2e 27 21 22 26

,/

i 25 mi Y

Drain Line ELBOW C Z

' x/

v

4.

SUMMARY

OF RESULTS i

Surc.e Line Shakedown Analysis:

Surge line. shakedown occurred within' the first three to four, thermal stratificttion cycles. The maximum peak strain anywhere.in' the elbow, and at any-time during the ~ shakedown, occurred in elbow B for the ' lowered loop plants-(vertical elbow at the bottom of the surge line riser).

It was equal t0-1.074, to be compared with-the maximum allowable peak strain _of,5.0%.

Therefore,_the-shakedown anaiAic has ~ satisfied the Primary Plus Secondary - andethe Thermal Expansion Stress Intensity requirements of the ASME Code (References 6 and-14).

9 h

Fatiaue-Usaae:

The fatigue usage for all surge-line elbows was demonstrated to be less than 0.6 f'

over the 40 year design life of the'B&W 177_ fuel assembly plants.

Thus, the cumulative fatigue usage factor remains less'_than' the Code allowable fatigue usage factor' of 1.0 'at all surge line locations. - The results from-the elbow-fatigue analysis are presented on the following-page, Table'.4-1.

7

==

Conclusion:==

Having previously demonstrated the fatigue usage of the nozzles and piping to bs acceptable, excluding the elbows, and having-demonstrated-the acceptability of-the elbows in this' supplement, the B&WOG response to NRC Bulletin-88-11 has been-completed.

The - highest zTotal: Cumulative Usage Factors for_ alli surge'.line

-locations are_given in Table _l-1 of Section 1.-

4-1

IAJLE 4-1.

TOTAL _ CUMULATIVE USAGE FACTORS FOR THE F1R.GE LINE EL30WS I

Elbows -- >

Elbow A Elbow B Eibow L Elbow D Elbow E Oconee Unit 1 0.13 0,49 0.34 0.38 does not (4 elbows) apply.

Oconee Unit 2 0.13 0.50 0.35 0.39 does not (4 elbows) apply.

TMI Unit 1 0.10 0.40 0.29 0.33 does not (4 elbows) apply.

Cr. River Unit 3 0.10 0.40 0.29 0.33 does not (4 elbows) apply.

ANO Unit 1 0.10 0.40 0.29 0.33 does not (4 elbows) apply.

Oconee Unit 3 0.13 0.48 0.33 0.38 does not (4 elbows) apply.

Davis-Besse Unit 1 0.59 0.57 0.44 0.15 0.30 l (5 elbows)

The elbows are shown on Figure 3-1 and Figure 3-2.

J f

4 4-2

i 5.

References 1.

BAW-2127, Final Submittal for Nuclear Reaulatory Commission Bulletin _38-11

" Pressurizer Surae Line Thermal Stratification", December 1990.

2.

NRC Bulletin 8811, " Pressurizer Surge Line Thermal Stratification",

December 20, 1988.

3.

BAW-20B5, Submittal in Resoonse to NRC Bulletin 88-11. " Pressurizer Surae

,(ing Thermal Stratification", May 1989.

4.

NRC Letter dated May 18, 1990, J.T. Larkins to M. A. Haghi, " Evaluation of Babcock and Wilcox Owners Group dounding Analysis Regarding NRC Bulletin 88-11".

l 5.

"ANSYS" Computer Code, Versions 4.lc and 4.3.

Engineering Analysis System, User's Manual Volumes I and II, Swanson Analysis Systems, Inc.

L' 6.

"ASME Boiler and Pressure Vessel Code", Section Ill,1986 Edition with no Addenda.

7.

BAW-2127, Supplement 1, Plant-Soecific Analysis in Response to Nuclear Reaulatory Commission Bulletin 88-11 "Pressur11gr Surae Line Thermal Stratification" Davis-Besse Nuclear Power Station Unit 1, September 1991, B&W Owners Group letter number 0G-970.

8.

"ABA0VS" Computer Code, Version 4.8.5, Hibbitt, Karlsson & Sorensen Inc.,

Pawtucket, RI, User's Manual Volume I,1989, 5-1

9.

ASME Code Case N-47-28, " Class 1 Components in Elevated Temperature Service", approved July 27. 1988, Appendix T, Paragraph T-1310

" Limits for Inelastic Strains".

10.

ASME Code Case N-196-1, " Exemption from the Shakedown Requirements When Plastic Analysis is Performed', approved January 21, 1982, Condition Number 2.

11.

Responses to Nucleq_r_f?aulatory Commissio_0_0uestions on B&W Owners Group Report BAW-2127, Final Submittal for Nuclear Reaulatory Commission Bulletin 88-11 " Pressurizer Surae Line Thermal Stratification", October 1991, B&W Owners Group letter number 0G-961.

12.

NRC Letter dated November 6, 1991, Jon B. Hopkins, Sr., to Donald C.

Shelton, Docket No. 50-346,

Subject:

" Pressurizer Surge Line Thermal Stratification, NRC Bulletin 88-11 (TAC N0. 72128)"

s 13.

NRC Letter dated July 24, 1991, Joseph W.

Shea to James A.

Taylor,

Subject:

"NRC Gulletin 88-11, Pressurizer Surge Line-Thermal 4

Stratification, Safety Evaluation Report".

14.

Response to a Code Inquiry relative to Section III, Division 1, NB-3228.4, file N192-6, March 26, 1992. This Code Inquiry and Response is provided herein as Attachment A.

15.

NRC Letter dated August 7,1990, M. D. Lynch, Sr. to D. C. Shelton, Toledo Edison Company, "NRC Bulletin 88-11, Pressurizer Surge Line Thermal Stratification - Evaluation of Babcock and Wilcox Owners Group Bounding Analysis" (TAC No. M72128).

5-2 i

l

l a

6.

DOCUMENT SIGNATURES I

This document prepared by:

(pl/0 9R

/

A

~

K /FT Bratcher, Engineer 11

/

~

Material &

ructural Analysis

  • $ la Y RT.

R. J. Gurd Enginee V

~/

Material & tructura Analysis This document reviewed for technical content and accuracy by:

l YL% 4/aladhoAt W. D. Maxharii, Supervisof Material & Structural Analysis Verification of independent review:

h_

(S- /6 -kL K. E. Moore, Manager

' Material & Structural Analysis Managet This document approved for release:

Sb0k2, A.'W. Robit. son, Program Manager B&W Owners Croup Thermal Stratification Working Group 6-1 xm?W

ATTACHMENT A Section Ill, Division 1, NB-3228.4 Code Inquiry and Response

(

A-1

L DONALD F. LANDERS prowoort TELEDYNE ENG;NEERING SERvCE5 130 SECONO AVENUE WALTMAM. MASSACHUSETTS T25d 9195

{

(617) 8903350 TWu (710) 324 7500 December 30, 1991 7569-2 l

Secretary ASME Coiler and Pressure Vessel Committee 1

345 East 47th Street New York, NY 10017 Sub.iect: Technical Inquiry - ASME BPVC Section III Gentlemen:

1 The writer respectf'lly requests that the-attached Technical Inquiry be considered by Section III.

Very truly yours, La Ela bc I

DFL/tmo Attachment i

I I

I A-2

.I

Secretary ASME Boiler and Pressure Vessel Co..

ee 7569-1 Attachment SCOPE Additional guidance is requested regarding paragraph NB-3228.4, Shakedown Analysis (19 Edition with Addendum).

BACKGROUND The structural integrity of a pressurizer surge line undergoing thermal loading (including expansion bending moments and forces) as a result of flow stratification has been demonstrated by performing a Shakedown Analysis in accordance with NB-3228.4 conservatively using kinematic hardening.

Shakedown occurred in a few cycles and a cumulative s

usage factor of < l.0 over the design life was calculated.

The deformations prior to shakedown are well within specified limits.

Subparagraph (b) of NB-3228.4 recognizes - that the following limits have been satisfied by the Shakedown Analysis:

NB-3221.2 - Local Membrane Stress Intensity NB-3222.2 - Primary Plus Secondary Stress Intensity NB-3222.5 - Thermal Stress Ratchet NB-3227.3 - Progressive Distortion of Nonintegral Co:nections However, satisfaction of NB-3222.3 Expansion Stress Intensity is not

(

specifically exempted even though in satisrying NB-3222.2 for piping, loadings categorized as expansion must be included.

IN0VIRY In demonstrating Shakedown in accordance alth NB-3228.4(b) are the expansion stress criterion of NB-3222.3 satisfied?

RESPONSES Yes, as long as the range of strain calculated on a plastic basis includes the effect of all cyclic loads which lead to distortion.

A-3

[

I

- _ _ _ - _ _ - _ _ _ _ - _ - - - - - _ _ _ _ _ _ - _ - - - - _ _ ~

R E

5 The American Society of c::::=: ::=:::::

8 Mechanical Sylnears 245 Eas c:- 5::ee:

New Yon. NY 100U Donald F. Landers President Telecine Engineering Services 130 Second Ave, Waltham, MA 02254

Subject:

Sec'Jon lit, Division 1, NS-5228.4 File #:

N!92-6 Referece:

Your letter dated December 30,1991

Dear Mr. La.wes:

!-j.

Our understanding of the questions in your inquity, and our reply, is as follows:

i Question:

In demonstrating shakedown in accordance with NB-3228.4(b), us the expansion stress cnterion of NB-3222.3 need to be satisfied?

4.

Reply-W I

f very truly yours, i

M christian Sanna i.

Assistant Secretary, Boiler & Pressure Vessel Committee i

(212) 605 4706 b

?

j-4 4

i 4

f A-4

[

A$MG StGCf Gu ts Gr>69 80' *tCAPS dtf 306 31 !*'S #te*3r0 ROP m999 et f 2;!728 063 tator*1t $* $ 4 F4tt 49-C9 t mawrtr + g revet /Pight affect f*e entgecre'at 06 s,taff strW 6.

r 4

, 4*4 A44
8%45 *se s;;de ia i.14 44ps40;-SJ{.etm.l!st ed w&,s.flm.et ne void 4 a Se te e eve d.. ag wwe.*wt.eni,.4 id wJes '*4t egGiove

.grpti e d;e y g*gy f 136SffWon af00htta'V Ifw'Cf Or 4CWtv Ie.

J

'wy-7 -t y er pm i et-F

=-'gN'-*TF*F

"'F'*"'

9 ar % M w+' 9? m y-es -W4 tww-sww.,y-t

    • +sg=v'=40-yfn'i+1=g rh 97 %yA wwo 4

T - W e M m e 9"

S-T**P ey*

FM e-w e

  • 4 F 17 WTM'M**9
  1. D'N*'NM"4*W*'*

'