New York Power Authority,Ja Fitzpatrick Nuclear Power Plant Effluent & Waste Disposal Semi-Annual Rept for 920101-0630
ML20114D079
Person / Time
Site: FitzPatrick 
Issue date: 06/30/1992
From: Harry Salmon
POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
To: Martin T
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
JAFP-92-0612, JAFP-92-612, NUDOCS 9209040129
Download: ML20114D079 (30)


Text

.

b Jim:s A. FJtzPatrick Nuclear Pow 2r PI:nt P,0. Box 41 Lycorning, New York 13093 515 342-3840 4 NewYorkPower 4# Authority

""C8"j"; "'"

s August 24, 1992 JAFP-92-0612 United States Nuclea Regulatory Commission Region 1 475 Allendale Road King of Prussia, PA 19406 ATTENTION:

Mr. Thomas T. Martin Reb onal Administrator i

SUDJECT:

JAMES A. FITZPATRICK NUCLEAR POWER PLANT DOCKET NO. 50-333. LICENSE NO. DPR-59 Gentlemen:

Attached is the Semi Annual Radioactive Effluent Release Report for the period of January 1, 1992 through June 30, 1992. This report is submitted in accordance with the requirements of Amendment 93, Appendix B, Section 7.3.C of the James A. FitzPatrick Nuclear Power Plant Technical Specifications.

This report includes, as an Addendum, revised Solid Waste and Irradiated Fuel Shipment, Tables 3A and 3B, of the Semi Annual Radioactive Effluent Release Report for the period of July 1, 1991 through December 31,1991.

The format used for the effluent data is as outlined in Appendix B of Regulatory Guide 1.21, Revision 1. Distribution is in accordance with Regulatory Guide 10.1, Revision 4.

If you have any questions concerning the attached report, please contact Alan McKeen, chemistry i

general supervisor, at the James A. FitzPatrick Nuclear Power Plant.

Very truly yours,

,/ 4 7-

^

'HARR P. SALMON, JR.

HPS/AM/WH/js j

Attachments cc:

Docnment Control Desk (USNRC)

J. Blaisiak (NMPC/NMP-2)

D. Sherman (ANI Library)-

R. Liseno R. E. Beedle (NYPA/WPO)

C. J. Gannon J. J. Kelly (NYPA/WPO)

RMS/JAF J. Blake (NYPA/WPO)

RMS-11 (WPO Records 4

0 4 0 n nS. Toth92o904o12, 92o600

.[fb (NVP A /WDA).

Management) 6' i

DR ADOCK 05000* 3 j

NEW YORK POWER AUTIIORITY JAMES A. FITZPATRICK NUCl. EAR POWER PLANT EFFI,UENT AND WASTE DISPOSAL SEMI ANNUAL REPORT JANUARY 1,1992 - JUNE 30,1992 DOCKET NO : 50-333 LICENSE NO.: DPR-59 3

s


.__---__.___.-__a

a -

o NEW YORK POWER AUTHORrrY -

JAMES A. FffZPATRICK NUCLEAR' POWER PLANT 4

EFFLUENT AND WASTE DISPOSAL SEMI. ANNUAL REPORT JANUARY 1992.- JUNE 1992 SUPPLEMENTAL INFORMATION FACILITY: JAFNPP LICENSEE: NEW YORK POWER AUTHORrrY_

1.

Technical Snecification Limits a.

Fission and Activation Gases:

l (1) The dose rate at or beyond the site boundary _due to radioactive materials released from the plant in gaseous effluent shall be limited as follows::

i l

(a) Less than or equal to 500 mrem / year to the whole body and less than or j

equal to 3000 mrem / year to the skin from noble gases l

(2) The air dose to areas at or beyond the site boundary from noble gases released from the plant in gaseous effluent shall be limited:

l (a) During any calendar quarter, to less than or equal to 5 mrad from gamr..a radiation, and less than or equal to 10 mrad from beta radiation; and, i

(b) During any calendar year, to less than or equal to 10 mrad from gamma -

radiation and less than or equal to 20 mrad from beta radiatian,

b. Tritium, Iodines and Particulates, Half Lives > 8 days:

i (1) The dose to a member of the public at or beyond the site boundary from l

Iodine-131, Iodine-133, Tritium, and radionuclides in particulate form with half-lives greater than 8 days released from the plant in gaseous effluent shall be j

limited:

l (a) During any calendar quarter to less than or equal to 7.5 mrem to any organ; -

and, (b) During any calendar year to less than or equal to 15 mrem tJ any organ.

(c) Less than 0.1% of the limits of Specification 3.4.a.1 and 3.4.a.2 as aresult of burning contaminated oil.

J d

1

1 NEW YORK POWER AUTiiORlW JAMES A. FITZPATRICK NUCLEAR POWER PLANT EFFLUENT AND WASTE DISPOSAL SEMI ANNUAL REPORT JANUARY 1992 - JUNE 1992 SUPPLEMENTAL INFORMATION (Continued)

L (2) The dose rate at or beyond the site bourdity due to radioactive materials n

released from the plant in gaseous effluents shall be limited as follows:

(a) Less than or equal to 1500 mrem / year to any organ from Iodine 131, Iodine-133, Tricium and fo. radioactive materials in particulate form with half lives greater than 8 dys (inhalation pathway only),

c.

Liquid Eifluents:

(1) The concentration of radioactive matt ials released to the unrestricted areas shall not exceed the values specified in 10 CFR 20, Appendix B, Table II, Column 2 For dissolved or entrained noble gases the concentration shall be limited to 2.00E-04 uCi/ml.

(2) The dose to a member of the public frorv radioactive materials released from the plant in liquid effluents to unrestricted areas shall be limited as follows:

(a) During any calendar quarter, limited to less than m ' qual to 1.S mrem to the whole body and to less than or equal to 5 m:

i to any organ; and, (b) During any calendar year, limited to less than or equal to 3 mrem to the whole body and to less than or equal to 10 mrem to any organ.

2.

Maximum Permissible Concentrations a.

Fission and activation gases:

(None specified)

b. Iodines:

(None specified)

Particulates, half-lives >8 days:

(%ne specified) c.

d. Liquid effluents:

DuattrL1' Ouarter 2 (1) Fission and activation 7.58E-05 1.56E-04 products (mixture MPC)

(gCi/ml)_

(2) Tritium (pCi/ml) 3.00E-03 3.00E-03 (3) Dissolved and entrained gases (gCi/ml) 2.00E-M 2.00E-M 2-

m NEW YORK POWER AUT110RITY JAMES A. FITZPATRICK NUCLEAR POWER PLANT EFFLUENT AND WASTE DISPOSAL SEMI ANNUAL REPORT JANUARY 1992 - JUNE 1992 SUPPLEMENTAL INFORM ATION (Continued)

3. Average En2rev (None specified) 4.

Measurements and Angroximations of Total Radioactivity a.

Fission and Activation Gases: Continuous monitor on each release path calibrated to a marinelli grab sample analyzed by gamma spectroscopy; bubbler grab sample analyzed for Tritium.

b. Iodines: Gamma spectral analysis of each charcoal cartridge and particulate filter for each release path, c.

Particulates: Gamma spectral analysis of each particulate filter and charcoal cartridge for each release path. A four week per quarter composite of particulate filters A,t och release path for Strontium-89 and Strontium-90. One week ner month particulate filter for each release path for gross alpha, d.

Liquid Effluents:

Gamma spectral analysis of each batch discharged, except composite analysis for Strontium 89, Strontium-90, Iron-55, Tritium, and Alpha.

e.

Solid Waste: Gamma spectral analysis of a representative sample of each waste shipment. Scaling factors established from off-site composite sample analyses to estimate concentration of non-gamma emitters. Ixw activity trash shipments, curie content estimated by dose rate measurement and application of appropriate scaling

factors, f.

Error Estimation Method: Overall error for sampling and analysis estimated by combining individual errors using error piopagation methods.

This process composed of determinate and undeterminate errve.

Determinate - Pump flowrates, volume measurements and analysis collection yields Undeterminate - Random counting error estimated using accepted statistical calculations 4

3

NEW YORK POWER AUTHORITY JAMES A. FITZPATRICK NUCLEAR POWER PLANT EFFLUENT AND WASTE DISPOSAL SEMI ANNUAL REPORT JANUARY 1992 - JUNE 1992 SUPPLEMENTAL INFORMN(ION (Continued) 1 I

5. Jlatrh Releases l

Liquid:

Duarter 1 Ouarter 2 (1) Number of batch releases:

6.00E + 00 2.70E + 01 i

(2) Total time period for batch 4.40E + 02 2.09E + 03 release: (min)

(3) Maximum time period for 9.20E + 01 2.82E + 02 batch release: (min)

(4) Average time period for 7.33E + 01 7.76E + 01 batch release: (min)

(5) Minimum time period for 4.00E + 01 4.70E + 01 batch release: (min)

Gaseous: There were no gaseous batch releases for this report period.

6.

Abnormal Releases a.

Liquid:

Ouarter 1 Ouarter 2 (1) Number of releases:

None Nane (2) Total activity released:

Non.e None

b. Gaseous (1) Number of releases:

None None (2) Total actisity released:

None None 4

l NEW YORK POWER AUTflORITY JAMES A. FITZPATRICK NUCLEAR POWER PLANT EFFLUENT AND WASTE DISPOSAL SEMI ANNUAL REPORT -JANUARY 1992 - JUNE 1992 TABLE 1A GASEOUS EFFLUENTS.. SUMMATION OF ALL RELEASES EST TOTAL JELT OUARTER1

, QUARTER 2 ERROR %

A.

FISSION AND ACTIVATION GASES 1.

Total Release Cl 6.52E+01 4.42E+01

$2.50E+01 2.

Average r: lease rate for period pCl/sec 8.29E+00 5.62E+00 3.

Tech. Spec. Umit B. IODINE 131

- 1.

Total lodine-131 Cl 1.04E-04.

$2.50E+01 2.

Average release rate for period pCl/sec 1.32E-05 3.

Tech. Spec. Umit C. IODINE 133 AND PARTICULATES 1.

lodine-133 and Particulates with half-lives >8 days Cl 1.85E-04 7.01E-05 s2.50E+01 2.

Average release rate for period pCl/sec 2.35E-05 8.92E-06.

3.

Tech. Spec Umit 4.

Gross alpha radicactMty Cl 8.99E-07 3.80E-06 52.50E+01 D. THITIUM 1.

Total Release Ci 3.01E-01

'4.70E-01 52.50E+01 2,

Average release rate for period pCl/sec 4.85E-02 5.98E-02 3.

Tech. Spec. Umit

  • E. PERCENT OF TECilNICAL SPECIFICATION LIMITS FISSION AND ACTIVATION GASES 1.

Quarterly gamma air dose limit 4.95E-02

'1.39E 2.

Quarterly beta air dose limit 2.57E-02 1.22E 3.

Yearly gamma ah dose limit

-2.48E-02 6.94E-03 4.

Yearly beta air dose limit 1.29E-02 6.10E-03 5.

Whole body dose rate limit 4.64E-04 1.25E-04 6.

Skin dose rate limit 1~.59E-04

-5.23E IIALOGENS, TRITIUM AND PARTICULATES WITil llALF-LIVES >8 DAYS 7.

Quarterly dose limit (organ) 3,28E-02 3.64E-03 8,

Yearly dose limit (organ) 1.64E-02 1.82E-03 9.

Organ dose rate limit 3.04E-04 4.80E-05 5

a

NEW YORK-POWER AUTIIORITY JAMES A. FITZPATRICK NUCLEAR POWER PLANT.

[

EFFLUENT 1AND--WASTE DISPOSAL-SEMI ANNUAL REPORT JANUARY 1992

- JUNE 1992-TABLE IB l

G ASEOUS EFFLUENTS.. ELEVATED RELEASE i

CONTINUOUS MODE NUCLIDES HELEASED UNil OUARTER1 DUARTER 2

1. Fission Gasta l

Argon-41 Ci 7.30E-02 i

Krypton-85m Cl 3.29E-02 2.21E-03 l

Krypton-87 Cl 1.40E-02 9.42E-04 j

Krypton-88 Cl


~

5.42E-02 1.93E+00 Xenon 131m Ci t

Xenon 133 Cl 1.97E-01 5.75E-02' Xenon-133m Cl 1.19E-01 Xenon-135m Ci 9.54E-02 Xenon-138 Cl 1.32E-01 8.90E-03 l

j TOTAL Cl 5.44E-01 2.17E+00 i

2 12dinti 4

l lodine-131 Ci

{

lodine-133 Ci TOTAL Cl 1

3. Particulates i-Strontium-90 Ci

-1.33E-10 7.76E-09 s

l t

Note: There were no batch releases for this report period.

v 1

f

(

6-

=i j

NEW YORK POWER AUTHORITY JAMES A. FITZPATRICK NUCLEAR POWEP. PLANT EFFLUENT AND WASTE DISPOSAL SEMI. ANNUAL REPORT JANUARY-1992'.- JUNE 1992 TABLEIC-GASEOUS EFFLUENTS.. GROUND LEVEL RELF>MES CONTINUOUS MODE -

NUCLIDES RELEASED 1!N_II OUARTER1

- OUARTER 2

1. Fission Gases Argon 41 Cl 4.65E-01 Krypton-85m -

Cl 7.14E+00 4.235+00 Krypton-87

'Cl 4.53E+00 2.16E+00 Xenon 131m Cl 8.59E+00 2.38E+01 Xenon 133

- Cl 3.94E+00-

'2.65E+00 Xenon-133m Ci 2.36E+01 4.90E+00 Xenore135 Cl 3.02E-01 1.11E+00-Xenon-135m Cl 8.06E+00 2.12E+00 Xenon-137 -

. Cl 2. 7 5 E-01 --

c,non-138 -

Cl-7.70E+00 1.03E+00 TOTAL Cl

6. 4 6E+01--

4.2OE+01;

2. lodines lodine-131 Cl-1.04E-04

-O.00E+00

- lodine-133 Ci 0.51E-06 0.00E+00 TOTAL --

Cl 1.08E-04'

3. Particulates Manganese Ci 8.38E-07 Cobalt-60 -.

Ci 4.29E-05

= 3 '. 8"/ E- 0 5 -

Zinc 45 Cl 1.30E-04

. 2.12 E-0 5 -

Antimony 125 Ci; 5.931.-06'-

Cesium 134

. Cl;.

1.71E-061 Cesium-137 Cl 1.02E-05 Note: There were no batch releases for this report period.

u 7

.a

'4 NEW YORK POWER AUTHORITY JAMES A. FITZPATRICK NUCLEAR POWER PLANT EFFLUENT AND WASTE DISPOSAL -

SEMI-ANNUAL REPORT JANUARY 1992 - JUNE 1992 TAllLE 2A LIQUID EFFLUENTS--SUMMATION OF ALL RELF.ASES EST TOTAL UNIT

.QUAf tTER 1

, QUARTER 2 ERROR %

A. l'ISSION AND ACTIVATION PRODUCI'S 1.

Total Release (not including tritium and alpha)

Cl 5.49E-03 3.47E-03 52.50E+01 2.

Average diluted concentra-tion during period pCi/ml 1.44E-10 9.05E-11 3.

Applicable limit 1.90E-04 5.80E-05 B. TRITIUM 1.

Total Release Cl 1.89E-01 1.10E+00 52.50E+01 2.

Average diluted concentra-tion during period pCi/ml 4.96E-09 2.87E-08 3.

Applicable timit 1.65E-04 9.55E-04 C. DISSOLVED AND ENTRAINED GASES 1.

Total Release Ci

$2.50E+01 2.

Average diluted concentra-tion during period pCi/ml 3.

Applicable Umit D. GROSS ALPilA RADIOACTIVITY 1,

Total Release Cl

$2.50E+01 E. VOLUME OF WASTE RELEASED (PRIOR TO DILUTION) liters 2.55E+05 1.06E+06 F. VOLUME OF DILUTION WATER USED DURING PERIOD liters 3.81E+10 3.84E+10 G. PERCENT OF TECilNICAL SPECIFICATION LIMITS 1.

Quarterly Whole Body Dose 5.80E-03 1.43E-02 2-Quarterly Organ Dose 2.74E-03 6.66E-03 3.

Annual Whole Body Dose 2.90E-03 7.13E-03 4.

Annual Organ Dose 1.37E-03 3.33E-03 l

l 8

NEW -YORK POWER AUTIIORITY JAMES A. FITZPATRICK NUCLEAR POWER-PLANT EFFLUENT AND WASTE DISPOSAL SEMI-ANNUAL REPORT-- JANUARY 1992 - JUNE 1992' TABLE 2B LIQUID EFFLUENTS BATCil MODE NUCLIDES RELEASED

.UbN.II OUARTER1 OUARTER 2 Hydrogen-3.

Cl 1.89E-01 1.10E+00 Chromium-51 Ci 1.03E-03 Manganese-54 Cl 2.22E-05 1.19E-04 Iron-55

__ l 7.41E-04 2.67E C Cobalt-58 Cl 2.20E-04 Cobalt @

Cl

'3.45E-03 4.26E-04~

Zinc-65 Cl 3.02E-05 1.73E-04.

Niobium 97-Cl 2.24E-06 Silver 110m Cl 2.17E-06 1.95E Terillium-132 Ci-2.75E --------

Cesium-134 Ci 3.2OE-05 Cesium-137 Cl 5.4SE-05 TOTAL Cl 1.95E 1.10E+00-Note: There were no continuous modo discharges during this report period,

]

NEW YORK POWER AUTHORITY l

JAMES A. h FATRICK NUCLEAR POWER. PLANT EFFLUENT: AND -WASTE DISPOSAL L

- SEMI. ANNUAL REPORT JANUARY 1992 - JUNE 1992 k

TABLE 3 1

SOLID WASTE AND IRRADIATED FUEL SHIPMENTS A. SOLID WASTE SIIIPPED OFFSITE FOR BURIAL OR DISPOSAL (NOT IRRADIATED FUEL) 6-month Period Est Total

.Unh Class A Class B Class C Error %

j_

1. Tvoc of Waste l

3

a. Spent resins, filter sludges, m

6.73E+01 9.67E+00-N/A evaporator bottoms, etc.

Ci 9.81E+02 5.12E+02 N/A 2.50E+01 3

m 9.12E+01 N/A N/A

b. Dry compressible waste, contaminated eqw;.. Gent, etc.

Ci 4.84E+00 N/A N/A 2.50E+01 3

c. Irradiated components, m

N/A

_N/A N/A

)

control rods, etc.

Ci N/A

_N/A N/A 3

d. Other (describe) m N/A N/A_

N/A 1

Ci N/A N/A N/A i

i

2. Estimate of Maior Nuclide Composition (by tvue'or waste) j
a. Spent resins, filter sludges, evaporator bottoms, etc.

Isotope Percent Curies Isotope _.

Percent '

Curies j-Iron-55 3.68E+01 5.49E+02 Cesium-134

.9.59E-01 1.43E+01 L

Zinc-65 3.68E+01 5.49E+02 Chromium-51' ' 9. 24E 1.38E+01 Cobalt-60 1.40E+01 2.08E+02 Cobalt-58

'6.54E 9.76E+00

{_

Manganese-54

_7.75E+00 1.16E+02 Nickel-63 3'.18 E 4. 7 4 E+00 Cesium 137 1.41E+00 2.10E+01 Iron-59 2.72E-01. 4.07E+00 e

b. Dry compressible _ waste, contaminated equipment, etc.

i Isotope Percent Curies Isotone Percent Curies

[

Zinc 6. 32E+01' : 3. 06E+00 -

Cesium-137 '

2.38E+00 '1.15E-01 L

Iron-55 1.44E+01^ 6.97E-01.

Carbon-14--

4.'/7E-01 2.31E '

- Cobalt-60

1. 3 5 E+01 6. 55 E-01'

- Nickel-63 1.61E-01-:7.80E-03

' Manganese-54 5,81E+00' 2.81E-_01 i

c. Irradiated components, control rods, etc.=

- None

[

d. Other None l'

a

'10

. ~. -. - - - -.. -

.-.a...

1 NEW.-YORK POWER AUTHORITY' JAMES A.- FITZPATRICK NUCLEAR - POWER PLANT '

EFFLUENT AND WASTE DISPOSAL SEMI-ANNUAL REPORT JANUARY-1992 - JUNE 1992 TABLE 3 (continued)

SOLID WASTE AND IRRADIATED FUELS bdIPMENTS 3.

Solid Waste Disposition No. of Shioments 11gde of Transportation-Destination 17 Truck Barnwell, SC 21 Truck Oak Ridge, TN (SEG) 4 Truck Wampum, PA (Alaron)

B. IRRADIATED FUEL SilIPMENTS (Disposition)

No. of Shioments Mode of Transportation

. Destination -

None N/A N/A 11

NEW YORK POWER - AUTIIORITY.

JAMES A. FITZPATRICK NUCI?.AR POWER PLANT EFFLUENT AND WASTE DISPOSAL SEMI ANNUAL REPORT JANUARY 1992 - JUNE 1992 ATTACilh1ENT NO 1 CilANGES TO Tile OFFSITE DOSE CALCULATION -htANUAL (ODCM)

In accordance with Section 7.3.C.3 of Amendment 93 to the James A. FitzPatrick Nuclear Power Plant Technical Specifications, changes made to the Offsite Dose-Calculation Manual (ODCM) during the reporting period shall be included in the.-

Semi-Annual Radioactive Effluent Release Report.

No changes were made to the ODCM this report period.

e k

12

NEW YORK POWER AUTHORITY JAMES A. FITZPATRICK NUCLEAR POWER PLANT EFFLUENT AND WASTE DISPOSAL SEMI-ANNUAL REPORT JANUARY 1992 - JUNE 1992 ATTACilMENT NO. 2

SUMMARY

OF CHANGES TO TIIE PROCESS CONTROL PROGRAM In accordance with Section 7.3.C.3 of Amendment 93 to the James A. FitzPatrick Nuclear Power Plant Technical Specifications, changes made to the Process Control Program (PCP) during the reporting period shall be included in the Semi-Annual Radioactive Effluent Release Report.

Revision 8 to the Process Control Program (PCP) procedure AP-1.10 was approved for use on March 4,1992 (PORC Meeting No.92-039). This revision was made to add one additional Waste Contractor Procedure (FO-OP-019-45230) and reflect organizational changes and responsibilities. This change did not reduce conformance to existing criteria for solid waste.

1. CONTRACTOR PROCEDURES:

A. The revisions to the current Chem-Nuclear Systems, Inc.

Procedures are as listed:

o CNSI Procedure, SD-OP-048 Process Control Program and Operating Procedure for In-Situ Solidification of Suspended Objects, Revision 5 was deleted on March 19,1992 (PORC Meeting No.92-044).

o CNSI Procedure, SD-OP-048-41802 Process Control Program and Operating Procedure for In-Situ Solidification of Suspended Objects at James A.FitzPatrick, Revision 0 was approved on March 19,1992 (PORC Meeting No. 92-M4),

o CNSI Procedure, FO-OP-019-45230 Polyethylene High Integrity Container Overpack Handling Procedure at James A. FitzPatrick, Revision 0 was approved on March 19,1992 (PORC Meeting No. 92-M4).

i o

CNSI Procedure, FO-AD-002-41S02 Operating Guidelines For Use of Polyethylene High Integrity Containers at James A. FitzPatrick, Revision 0 was approved on March 19,1992 (PORC Meeting No.92-044).

13

NEW YORK POWER AUTIIORITY JAhiES A. FITZPATRICK NUCLEAR POWER PLANT EFFLUENT AND WASTE DISPOSAL SEhil ANNUAL REPORT JANUARY 1992 - JUNE 1992 A1TAClth1ENT NO. 3 SUht 3Y OF CilANGES TO Till. ENVIRONhlENTAL h10NITORING AND DOSE CALCULATION LOCATIONS In accordance with section 7.3.C.3 of Amendment 93 to the James A. FitzPatrick Nuclear Power Plant Technical Spec!fications, a listing of new locations for dose calculation and/or environmental monitoring identified by the land use census shall be i

included in the Semi Annual Radioactive Effluent Release Reports.

l

1. CllANGES IN ENVIRONh1ENTAld10NITORING LOCATIDES No change in Environmental hionitoring Locr.tions was required based on the land use census.
2. NEW LOCATIONS FOILJ1DSE CALCULATIONS No changes m Dose Calculation Receptor Lochtlons were required based on land use census.

ti t

f l

4 I~

i 14 L

=__-._.. -....

NEW YORK POWER AUTilORITY m

JAMES A. FITZPATRICK NUCLEAR POWER PIANT EFFLUENT AND WASTE DISPOSAL SEMI ANNUAL REPORT JANUARY 1992 - JUNE 1992 A'ITACilh1ENT No. 4 DEVIATIONS FROM Tile REQUIRED ENVIRONMENTAL DAMPLING SCllEDULE in accordance with Section 7.3.C.7 of Amendment 93 to the James A. FitzPatrick Nuclear Power Plant Technic Specifications, the cause for unavailability of any environmental samples required during the report period shall be included in the Semi.

Annual Radioactive Effluent Release Reports.

EXCEPTION TO TIIE ENVIRONh1 ENTAL, SAMl'(JNG PROGRAM There were no exceptions to the Environmental Sampling Program during this report period.

15

~..

NEW YORK POWER AUTilORITY JAhiES A. FITZPATRICK NUCLEAR POWER PLANT EFFLUENT AND WASTE DISPOSAL SEhil ANNUAL REPORT JANUARY 1992 JUNE 1992 ATTACllMENT NO. 5 SEMI. ANNUAL

SUMMARY

OF llOURLY METEOROLOGICAL DATA in accordance with Section 7.3.C.2 of Amendment 93 to the James A. FitzPatrick Nuclear Power Plant Technical Specifications, an annual summary of meteorological data may be included and submitted in the Semi Annual Radioactive Effluent Rclease Report within 60 days after January 1 of each year.

Meteorological data for the period of January 1,1992 through June 30,1992 will be included in the second half of the 1992 report, l

l 16

NEW YORK POWER AUTilOltlTY JAhiES A. FITZPATRICK NUCLEAR POWER PLANT EFFLUENT AND WASTE DISPOSAL SEhil ANNUAL REPORT JANUARY 1992 - JUNE 1992 NITACllhlENT NO. 6 REPORT NOTES Table 2Alts.thm A and 11 and Table _2[LNormal Llould Efilatall The values for Tri'.ium. Strar!Nm 89, Strontium 90, and Iron 55 were calculated from tbc most recent avancle wra;@ data. If the actual sample data significantly alters the percent of allowable release limits, the report will be revised and redistributed.

Addendum 1 - Solid Waste and Irradinted Fuel Shipments Tables 3A nnd 3_11 Attached, as an addendum, is a revision to the Semi Annual Radioactive Effluent Release Report for the period of July 1,1991 through December 31,1991.

Table 3A includes format revisions to comply with Appendix B of Regulatory Guide 1.21.

Table 3B includes format revisions and two calculational error corrections to the supplemental data, t'

l 17

~

NEW YORK POWER AUTilORrrY 1

JAh1ES A. FrI2 PATRICK NUCLEAR POWER PIANT i

EFFLUENT AND WASTE DISPOSAL SEhil ANNUAL REPORT JANUARY 1992. JUNE 1992 ADDENDUA11 TAllLE 3A 2

SOLID WASTE AND 1RRADIATED FUEL SillPA1ENTS (JULY 1991 DECEh111ER 1991) 1 A. SOLID WASTE SillPPED OFF SITE FOR DISPOSAL OR llURIAL (NOT 1RRADIATED FUEL)

EST SIX MONTil TOTAL 1.

Type orwasts unir l'entoo Innone 3

a. Spent resins, filter sludges, m

6.68E t 01 1.00E + 01 evaporator bottoms, etc.

Ci 2.48E + 02 2.50E + 01 3

b. Dry compressible 'vaste, m

9.89E + 02 1.00E + 01 contaminated equipment, etc.

Ci 3.37E + 00 22.50E+01 3

c.1rradiated components, m

N/A N/A control rods, etc.

Ci N/A N/A 3

d. Other (describe) m N/A N/A Ci N/A N/A 2.

Estimate or Malar NuclidLCmnposition (by type of waste)

a. Spent resins, filter sludges, evaporator bottoms, etc.

hat 0p2 Percent Curies Jsotope Percent furies Zine-65 4.91E+01 1.22E+02 Chromium 51 1.30E+00 3.23E+00 Cobalt 60 1.70E+01 4.42E+01 Silver-110m 8.07E-01 2.00E+00 Iron-55 1.31E+01 3.25E+01 Zirconium 95 5.79E-01.1.44E+00 Manganese 54 6.45E+00 1.60E+01 Antimony 125 5.44E-01 1.35E+00 Cesium 137 3.20E+00 7.94E+00 tron 59 5.10E 1.27E+00 Ruthenium 106 2.76E+00 6.84E+00 Carbon-14 2.53E-01 6.27E-01 Cobalt 58 1.73E+00 4.30E+00 Ltmthanum 140 2.29E-01 5.68E-01 Cesium 134 1.36E+00 3.38E+00 Nickel-63 1.65E-01 4.09E-01 18

c.

NEW YORK POWER AUTIlORITY l

JAMES A. FITZPATRICK NUCLEAR POWER PLANT EFFLUENT AND WASTE DISPOSAL SEMI ANNUAL REPORT JANUARY 1992 JUNE 1992 l

ADDENDUM 1 (continued) i l

TAllLE 3A SOLID WASTE AND IRRADIATED FUEL SillPh1ENTS l

(JULY 1991. DECEMilER 1991)

?

r

b. Day compressible waste, contaminated equipment, etc.

l Isotope Percent Curies Isotope femall Curles Iron 55 S.68E+01 2.13E+00 Nickel 63 4.04E-01 1.52E-02 Zine-65 2.52E+01 9.46E-01 Antimony-125 3.05E-01 1.14e-02 Cobalt 60 1.11E+01 4.15E-01 Silver-110m 2.70E-01 1.01E-02 Manganese 54 2.16E+00 8.12E-02 Zirconium 95 2.47E-01 9.25E-03 Ruthenium 106 1.43E+00 5.36E-02 fron 55 2.14E-01 8.01E-03 i

Cesium 137 1.10E+00 4.12E-02 1.zanthanum 1401. 68E-01 6.29E-03 Chromium 51 4.22E-01 1.58E-02 Carbon 14 1.26E-01 4.74E-03 3

c. Irradiated components, control rods, etc.

Nonc

d. Other (describe)

None i

I 3, Solid Waste Disposition Number of Shipments Mode of Transnortation Destination i

22 Truck Barnwell, SC 61 Truck Richland, WA 4

B. IRRADIATED FUEL SillPMENTS (Disposition)

Number of Shipments Mode of Transnortation Destination None N/A-N/A 19

NEW YORK POWER AUTIIORITY JAhiES A. FrI2 PATRICK NUCLEAR POWER PLANT EFFLUENT AND WAS'17! DISPOSAL

]

SEht!. ANNUAL REPORT JANUARY 1992 JUNE 1992 ADDENDUh11 (continued)

TAllLE 311 i

SOLID WASTE AND 1RitADIATED FUEL SillPhfENTS (JULY 1991 DECEh111ER 1991)

A.

NI(C CLASS A I

1. 70% Powdered Resin /30% Bend Ilesin in a lifC (LSA)

Container Type:

170.8 ft' IllC Solidification Media:

None i

3 Total Volume:

170.8 ft No. of Shipments:

1 Type:

Cask -

Mode:

Truck i

i Principal Percent Quantity Isotopes Curies Abundance Determination Zinc-65

1. 8 4 E+ 01 5.34E+01 M

Cobalt 60 4.48E+00 1.30E+01 M

Ruthenium 106 2.70E+00 7.84E+00 E

1ron 55 2.68E+00 7.78E+00 E

Cesium-137 1.37E+00 3.98E+00 M

Manganese 54 1.23E+00 3.57E+00 M

Silver-110m 1.12E+00 3.25E+00 M

Cesium 134 6.65E-01 1.93E+00 M

Zirconium-95 5.80E-01 1.68E+00 E

Chromium 51 3.72E-01 1.00E+00 E

Cobalt-58 2.57E-01 7.46E-01 M

Antimony 125 1.76E-01 5.11E-01 M

1ron 59 1.49E-01 4.33E-01 E

Iodine-131 1.18E-01_

3.43E-03 E

Lanthanum 140 7.29E-02 2.12E-01 M

Nickel-63 5.12E-02 1.O E E TOTAL:

3.45E+01 E = Estimated ai = Measured 29

NEW YORK POWER AUTIIOh TY JAhiES A. FITZPATRICK NUCLEAR POVER PLANT EFFLUENT AND WASTE DISPOSAL SEhil ANNUAL REPORT JANUARY 1992 - JUNE 1992 i

ADDENDUh11 (continued) j TAllLE 3B SOLID WASTE AND IRRADIATED FUEL SillPh!ENTb l

(JULY 1991 DECEh111ER 1991) i A.

NRC CLASS A i

j 1.100% Powdered Resin in a iIIC (LSA)

Container Type:

170.8 ft HIC 3

Solidification hiedia:

None a

8 i

Total Volume:

512.4 ft i

No. of Shipments:

3 Type:

Cask hiode:

Truck ~

Principal Percent Quantity i

Isotopes Curies Abundance Determination i

Zine-65

-3.20E+01-4.14E+01 M-l Cobalt 60 2.09E+01 2.71E+01 M

i

. Iron 55 1.14E+01 1.48E+01 E

i Cesium 137 4.71E+00 6.10E+00 M

l hianganese-54 3.43E+00 4.45E+00 M

i Cobalt 58 2.05E+00 2.CSE+00 M

i-Cesium 134 1.32E+00 1.71E+00' M

Chromium 51 1.20E+00 1.55E+00 M

l Nkkel 63 1.49E-01 1.93E-01 E

i 4

-f TOTAL:

7.72E+01 l-E = Estimated i.

hi = hicasured i

A 4

21

..... ~.

i NEW YORK POWER AUTIIORITY JAhiES A. FITZPATRICK NUCLEAR POWER PLANT EFFLUENT AND WASTE DISPOSAL SEhil ANNUAL REPORT JANUARY 1992 JUNE 1992 l

a.

ADDENDUh11 (continued)

TAllt.E 311 SOLID WASTE AND IRRADIATED FUEL SillPMENTS (JULY 1991 DECEMBER 1991)

A.

NRC CLASS A

1. 70% Bead Resin /30% Powdered Resin in a IIIC (LSA)

Container Type:

170.8 ft' lilC Solidification Media:

None l

Total Volume:

170.8 ft' No, of Shipments:

1 Type:

Cask hiode:

Truck Principal Percent Quantity IsotoDes

.Culic.$

fdntndangg Determinallpa l

l Zinc-65 8.86E+00 5.52E+01 hi l

Cobalt 60 2.35E+00 1.46E+01 M

j Iron 55 1.72E+00 1.07E+01 E

Ruthenium 106 1.03E+00 6.41E+00 E

Manganese 54 6.61E-01 4.12E+00 M

Cesium 137 4.24E-01 2.64E+00 M

Zirconium 95 2.20E-01 1.37E+00 E

i Cesium 134 1.73E-01 1.08E+00 M

Lanthanun.-140 1.61E-01 1.00E+00 M

Antimony-125 1.46E-01 9.09E-01 M

Cobalt 58 1.43E-01 8.91E-01 M

Chromium 51 6.25E-02 3.89E-01 E

Iron 59 3.10E-02 1.93E-01 E

i Nickel-63 2.67E-02 1.66E-01 E

10 dine 131 2.56E-02 1.59E-01 E

1 TOTAL:

'1.61E+01-E = Estimated M = Measured i

l l

22

NEW YORK POWER AUTilORITY JAhiES A. FITZPATRICK NUCLEAR POWER PLANT EFFLUENT AND WASTE DISPOSAL SEhil ANNUAL REPORT JANUARY 1992 - JUNE 1992 ADDENDUM 1 (continu;.1)

TAllLE 311 SOLID WASTE AND IRRADIATED FUEL SillPMENTS (JULY 1991. DECEMBER 1991)

A.

NRC CLASS A

1. 85% Powdered Resin /15% Bead Resin in a HIC (LSA) 3 Container Type:

170.8 ft lilC Solidification hiedia:

None 3

Total Volume:

170.8 ft No. of Shipments:

1 Type:

Cask hiode:

Truck Principal Percent Quantity halopJ:1 Curies Abundance Determination Zinc 65 2.50E-01 4.13E+01 h1 Cobalt-60 1.77E-01 2.92E+01 hi Iron 55 1.00E-01 1.65E+01 E

Cesium-137 3.55E-02 5.8GE+00 hi hianganese-54 2.82E-02 4.66E+00 h1 Cesium 134 9.49E-03 1.57E+00 hi Cobalt 58 2.38E-03 3.93E-01 hi Nickel-63 2.02E-03 3.342-01 E

TOTAL:

6.05E-01 E = Estimw.:d M = Measured i

23

NEW YORK POWER AUTilORITY JAMES A. FITZPATRICK NUCLEAR POWER PLANT EFFLUENT AND WASTE DISPOSAL SEMI ANNUAL REPORT JANIJARY 1992 JUNE 1992 ADDENDUM 1 (continued) i TAllLE 311 i

SOLID WASTE AND IRRADIATED FUEL SIIIPMENTS l

(JULY 1991 DECEMllER 1991) 0 A.

NRC CIASS A l

1. Charcoal Filter Pressure Vessel (LSA)

I Container Type:

18.8 ft) Il!C i

Solidification Media:

i4one i

Total Volume:

56.4 ft' No. of Shipments:

0.4 '

Type:

Cask Mode:

Truck 1

Principal Percent Ouantity Isotopes Curies Abundance Determination Zinc-65 5.23E-01 3.31E+01 M

i Iron 55 4.42E-01 2.80E+01 E

Cobalt 60 4.34E-01 2.75E+01 M

Manganese 54 1.41E-01 8.92E+00 M

Carbon-14 1.67E-02 1.06E+00 E

Cesium 137 7.27E-03 4.60E+00 M

Silver-110m 6.30E-03 3.99E-01 M

Nickel 63 4.91E-03 3.11E-01 E

Cobalt 58 3.92E-03 2.48E-01 M

TOTAL:

1.58E+00 E = Estimated 1

M = Measured

  • 3 Pressure Vessels out of one 7 Pressure Vessel Shipment combined with one Table 3B A.1 (page 25) shipment.

24

.4 NEW YORK POWER AUTilORITY JAMES A. FITZPATRICK NUCLEAR POWER PLANT EFFLUENT AND WASTE DISPOSAL SEMI ANNUAL REPORT JANUARY 1992 - JUNE 1992 ADDENDUM I (continued)

TAHLE 3B SOLID WASTE AND IRRADIATED FUEL SillPMENTS (JULY 1991 DECEMBER 1991)

A.

NRC CIASS A

1. Bend Resin Pressure Vessel (LSA)

Container Type:

18.8 ft' IllC Solidification Media:

None 3

Total Volume:

733.2 ft No. of Shipments:

5.6

  • Type:

Cask Mode:

Truck Principal Percent Quantity hotopes Curies Abundance J2 tcImination Zine-65 5.90E+00 5.00E+01 M

Iron 55 2.07E+00 1.75E+01 E

Cobalt 60 2.03E+00.

1.72E+01 M

Manganese 54 9.75E-01 8.24E+00 M

Cesium 137 1.66E-01 1.40E+00 M

Chromium-51 1.34E-01 1.13E+00 M

Antimony-125 1.24E-01 1.05E+00 M

Ruthinium 106 1.23d-01 1.04E+00 E

Carbon-14 7.83E-02 6.62E-01 E

Iron 59 5.03E-02 4.26E-01 E

Cobalt 58 4.59E-02 3.88E-01 M

Silver-110m 4.44E-02 3.75E-01 M

Cesium 134 3.20E-02 2.70E-01 M

Zirconium 95 2.35E-02 1.98E-01 E

Nickel-63 4.91E-03 3.11E-01 E

TOTAL:

1.18E+01 E = Estima..ed M = Measured

  • 5 Shipments of 7 Pressure Vessels and 1 Shipment of 4 Pressure Vessels combined with 3 Pressure Vessels k

from one Table 3B A.1 (page 24) shipment.

25

-i y

'j

NEW YORK POWER AUTilORITY JAMES A. FIT /. PATRICK NUCLEAR POWER PLANT EFFLUENT AND WASTE DISPOSAL SEMI ANNUAL REPORT JANUARY 1992 - JUNE 1992 ADDENDUh11 (continued)

TA13LE 311 SOLID WAS4E AND litRADIATED FUEL SillPhlENTS (JULY 1991 DECEMilER 1991) t A.

NHC CLASS A

1..}009'c Bend Resin in a IIIC (LSA)

Container Type:

170.8 ft' lilC Solidification Media:

None 3

Total Volume:

341.6 ft No. of Shipments:

2 Type:

Cask Mode:

Truck Principal Percent Quantity Isotones Curies AbundaDC&

Determination Zinc-65 1.19E+01 4.3OE+01 M

Iron 55 5.72E+00 2.0$E+01 E

C,0balt-60 5.62E+00 2.03E+01 M

Manganese 54

'SE+00 1.15Et01 M

Cobalt 58

%.43E-01 1.52E+00 M

Iron 59 2.66E-01 9.59E-01 E

Carbon 14 2.16E-01 7.79E-01 E

Cesium-137 1.72E-01 6.19E-01

'T Cesium-134 1.27E-01 4.58E-01 M

Nickel-63 6.35E-02 2.29E-01 E

TOTAL:

2.77E+01 l

E = Estimated M = Measured 1

26

3 NEW YORK POWER AUTilORI'lY i

JAMES A. FITZPATRICK NUCLEAR POWER PLANT EFFLUENT AND WASTE DISPOSAL SEMI ANNUAL REPORT JANUARY 1992 - JUNE 1992 ADDENDUM 1 (continued)

TAllLE 31l SOLID WASTE AND 1RRADIATED FUEL SIIIPMENTS 2

(JULY 1991. DECEMBER 1P91)

A.

?'.!!C CIASS A 1.100% Dewatered Bead Resin in a HIC (I.SA)

Container Type:

205.8 ft' IllC Solidification Media:

None Total Volume:

205.8 ft' No. of Shipments:

1 Type:

Cask Mode:

Truck Principal Percent Ouuntity Isotones Curies Abundance Jktermination Zinc 65 3.41E+01 5.59E+01 M

Iron 55 8.38E+00 1.06E+01 E

Cobalt-60 8.22E+00 1.04E+01 M

Manganese 54 6.36E+00 8.07E+00 M

Ruthenium 106 2.99E+00 3.79E+00 E

Chromium-51 1.46E+00 1.dDE+00 E

Cobalt-58 1.38E+00 1.75E+00 M

Cesium 137 1.06E+00 1.34E+00 M

Cesium 134 1.05E+00 1.33E+00 M

Antimony 125 9.04E-01 1.15E+00 M

Silver-110m 8.19E-01 1.04E+00 M

Iron 59 7.71E-01 9.78E-01 E

Zirconium 95 6.15E-01 7.80E-01 E

t l

Lanthanum 140 3.29E-01 4.17E-01 M

i Carbon-14 3.16E-01 4.01E-01 E

l Nickel-63 9.29E-02 1.18E-01 E

TOTAL:

7.89E+01 E = Estimated M = Measured 27

NEW YORK POWER AUTilORITY JAhiES A. FITZPATRICK NUCLEAR POWER PLANT EFFLUENT AND WASTE DISPOSAL SEMI ANNUAL REPORT JAMUARY 1992 - JUNE 1992 ADDENDUM 1 (continued)

TAllLE 311 SOLID WASTE AND 1RRADIATED FUEL SillPh1ENTS (JULY 1991 DECEh111 Ell 1991)

A.

b'ItC CIASS A

1. Comoacted/Uncompacted Drv Active Waste (LSA)

Container Type:

13A Hox (various sizes)

Solidification hiedia:

None Total Volume:

6503.06 ft)

No. of Shipments:

11 Type:

Steel Hox hiode:

Truck Principal Percent Quantity Isotones faries Abundaneg Determination Zine-65 7.19E-01 4.33E+01 E

Iron-55 4.29E-01 2.58E+01 E

Cobalt 60 3.04E-01 1.83E+01 E

hiangsnese 54 6.60E-02 3.97E+00 E

tluthinium 106 4.35E-02 2.62E+00 E

Cesium 137 3.34E-02 2.01E+00 E

Chromium-51 1.28E-02 7.73E-01 E

Nickel 63

1. 2 3'E-C 2 7.41E-01 E

Antimony 125 9.29E-03 5.59E-01 E

Silver 110m e.22E-03 4.29E-01 E

Zirconium 95 7.51E-03 4.52E-01 E

Iron 59 6.51E-03 3.92E-01 E

12nthanum 140 5.12E-03 3.08E-01 E

Caibon 14 3.85E-03 2.32E-01 E

TOTAL:

1.66E+00 E = Estimated hi = hieasured 1

28

s.e,

  • 6 NEW YORK POWER AlJrilORITY JAMES A. FrrZPATRICK NUCLEAR POWER PLANT I

EFFLUENT AND WASTE DISPOSAL SEMI ANNUAL REPORT JANUARY 1992 JUNE 1992 ADDENDUM 1 (continued)

TAllLE 311 SOLID WASTE AND IRRADIATED FUEL SillPMENTS (JULY 1991 DECEMllER 1991)

A.

NRC CLASS A

1..Lincompacted Dry A-dve Wnste (Dirt / Rock) (LSA)

Container Type:

LSA Box (various sizes)

Solidification Media:

None Total Volume:

28440.2 ft No. of Shipments:

57 Type:

Steel Box Mode:

Truck Principal Percent Quantity Isotopes Q)IirJi Abunda11ce Determination Iron 55 1.61E+00 9.i'.E&O1 E

Zine-65 5.90E-02 3.46E+00 E

Cobalt 60 4.08E-02 2.39E+00 E

TOTAL:

1.71E+00

[

E = Estimated M = Measured 3

29

_ _ _ _.