SEQUOYAH NUCLEAR PLANT UNITS.1 & 2 EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT.
Supplemental.Information First Half 1983 8504090:M1 8 PDR ADOCM 0 327'.
i R
PDR f:-
4
~
Y
e' -.
ar.
.s EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT SUPPLEMENTAL INFORMATION FIRST HALF 1983
. 1.. Regulatory Limits.
a.
Fission and Activation Gases:
1(1) ' Instantaneous Nuclide Dependent.(All~ Release Points)
Shield Building Auxiliary Building
. Condenser 1Va~cuum Exhaust.
' Service Building NOTE: Total' plant release. rate limit per nuclide are
- ' ' established by TVA's Radiological Hygiene Branch.
These limits are.further evalu~ated to each vent based on design flowrate. Technical specifica-tion will not be exceeded until the sum of indi-vidual. isotope release rate per release rate limit exceed 1.0.
- b. & c.
Iodines and particulates, h'alf-lives ~>8 days
.(1). Instantaneous-:NuclideDependent NOTE: ' Total plant release rate limit per nuclide are established:by TVA's Radiological Hygiene. Branch.
These limits are further evaluated to each vent
~
based on design flowrate.. Technical specification will'not be exceeded until the sum'of' individual isotope' release rate per releaseirate limit' exceed 1.0.-
Td.
Liquid effluent: I MPC < 1.0 (ref. 10 CFR 20,' Appendix B, note
~
3C, Table II, column 2).-
u i..
e.
s
- (1),' Liquid'- <;3.0E-3.pci/ml-(ref. 10-CFR'20,-Table II,. column 2)
(2) : Airborne
- (ref. :10 CFR 20, Table I, column 2)
Shield Building ~'-
< 3.783E+03 pCi/sec
? Auxiliary Building
][12.702E+04-pCi/sec 4
?
{
- -1
(.
m
~
-c
e-
-=
~
- 7 O
j
% d. 1 L*:,
4 l*
l i
EFFLUENT'AND WASTE DISPOSAL SEMIANNUAL REPORT ESUPPLEMENALINFORMATION(CONTINUED) 1FIRST HALF 1983 L1.
Regulatory Limits. (Continued)
Service Building
.< ' 1.405E+03 pCi/sec
-Condenser Vacuum Exhaust
{ 6.079E+00 pCi/sec
~
ThesellimitsLare establised by TVA's Radiological NOTE:
1 Hygiene-Branch. based on each vents design flow
-rate.
- 2. :: Maximum Permissible Concentrations a.
Fission ~and Activation Gases: ;Not Applicable
'b.
1 Iodines: LNot' Applicable.
ic.
-Particulates,. half-lives >8' days: -No't Applicable-
'd.
Liquid' effluents: fsum of indv. MPC ratios <1.0
-(ref.:10 CFR 20,' Appendix B, note 1) 3..
Average Energy - Not Applicable-
.4.
Measurements and kpproximationsLof Total-Radioactivity.
a., b. & c'.
Fission and Activation Gases, Iodines, and Particulates:
a.
Fission and Activation Gases Airborne effluent ga'seous? activity'is continuously monitored and Krecorded. Additional' grab samples from the~ shield,' auxiliary, service and condenser vacuum exhausts are:taken and analyzed at ~
~
- 1 east monthly'.toidetermineTthe quantity'of noble'gasLactivity.
. released for-the month based on.the average veat.flowcates're-corded for the sampling period. Also,~ noble? gas' samples are collected'and evaluated forzthe shield and auxiliary buildings
- following startup,~ shutdown-or a. rated thermal power changes ;
cexceeding'15% within one hour. The. vent flowrates for the
. shield auxiliary,; service buildings, and condenser ~ vacuum'ex-
- haust areidetermined and recorded once a' shift.
' The quantity of-noble gase's released through the! shield build-
.in'gidue to: purging or. venting of containment and relea'ses of
-waste gas decay tanks'are also? determined.
1The;totabnob1'e'gasLactivityreleasedifor.themonth.is-then-determined ~by summing all ofithe activity' released from each-
- ventJfor all sampling. periods, the' activity-released from' purginglor venting'of containment, Land the: activity released
~
'from waste gasLdecay: tank (s).
E
~
C
'3
['
I
- ~
j[
s s
7 w
^
r
~
. :.f.. -...
EFFLUENT!AND WISTE DISPOSAL SEMIANNUAL' REPORT
- SUPPLEMENAL INFORMATION (CONTINUED)
FIRST HALF 1983
.4.
l Measurements and Approximations of Total Radioactivity _ (Continued)
Allowancelis made for a plus or minus.one.-sigma counting error -
associated with the gamma-isotopic analyses.
- b. & c.
Iodines and Particulates
~ Iodine'and particulate activity is continuously monitored and re -
corded. Charcoal:and particulate samples are.taken from the shield-
- and auxiliary building. exhausts.and analyzed at least weekly to deter-
'mine thel total activity released from the plant based on-the_ average
.. vent flowrates recorded for' sampling period.
Also, particulate and-charcoal samples are taken from the auxiliary land shield buildings once per 24~ hours-for 2 days following startup, shutdown or' a rated thermal power change. exceeding 15% within one
- hour; ' The quantity of iodine and particulate released from each vent:during each sampling' period is then determined using-the average vent flowrates recorded for the sampling period and acti-vity concentration.
-Th_e' vent.flowrates from'the shield and. auxiliary buildings are
~
recorded onceJaTshift.
The total.' particulate and iodine activity released forlthe m'onth is then. determined by summing all'of the activity released from-the~ shield and auxiliary buildup for al1~ sampling periods.
Allo' ance is made for a plus or minus one sigma counting' error w
associated with-the gamma isotopic analyses.
d.
Liquid Effluents
-(1)fBatch--_(Radwaste)
- Total: gamma isotopic activity concentrations are determined" g'
- on each batch of liquid ' effluent prior _to rele'as~e The total
'curieicontent of a-released batch is. determined b summing
+
each nuclide's concentration and multiplying by.t e total volume discharged. The total: activity released during a month'
-is.then' determine ~d by summing the activity content of each.
~
batch discharged'during the month.
o c
A 9
3
^
<~
q;
~
{
~
e.
3..
EFFLUENT'AND WASTE DISPOSAL' SEMIANNUAL REPORT SUPPLEMENAL INFORMATION (CONTINUED)
FIRST HALF 1983-4.\\ Measurements;and.ApproximationsofTotalRadioactivity (Continued)
(2) 1 Continuous Releases and Periodic Continuous' Releases
-(Condensate Regenerants, Turbine Building Sump and Steam Generator Building)
.' Total gamma isotopic activity' concentration is determined daily-on a composite sample. 'The total curie content.of' the continuous release is determined daily by_ summing:each nuclide's~ concentration and multiplying by the total volume
' discharged. The. total activity released during'the month is then determined-by. summing the activity. content of each daily-composi"e'for month
- Allowance is made. for plus or minus one sigma counting error associated with the total gamma' isotopic analyses.
52 B'atch' Value Units
- first, Second Quarter Quarter.
a.
Liquid
_(1) Number of batches released 130-106
-Each (2) Total time period for batch releases 24,218 18,689 Minutes (3) _ Maximum time period for. a batch release 755 345 Minutes
~(4) Average time period'for batch releases 186 176
- Minutes (5) Minimum time period for a batch release 59' 74
- Minutes-
- (6).Averagestreamflowduringperiodsof
- effluent into a flowing stream:
(a)
(a)
(. a)See Radiological Hygiene Branch's portion ~of semi-annual effluent release report, b'
-Gaseous l(Continued)'
(1)7 Number of batches released 211 233 Each n(2). Total time period for batch releases.
31,165L
'28,238 Minutes
-4R
/
1 e-g.
m----
c.:.'
-EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT SUPPLEMENAL INFORMATION (CONTINUED)
FIRST HALF'1983 b.
Gaseous (Continued)'
(3) Maximum time period for a batch release 1,380 532 Minutes (4)' Average time period for batch ' releases 148 121
. Minutes
.(5)~ Minimum time period for a batch release 2
10 Minutes
- 6. -Abnormal Releases a.
Liquid ~
(1) Number.of Releases 1
0 (2) Total Activity Released 1.25E-02 0.00E-01 Ci b.
. Gaseous
'(1) Number of. Releases 0
-0
=(2) Total Activity Released 0.00E 0.00E-01 Ci L
- .p.-....
EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT BATCH-LIQUID. EFFLUENTS - SUMMATION OF ALL RELEASES
- RADWASTE (T0' COOLING TOWER BLOWDOWN)
FIRST; HALF 1983 x
.First Total Second Total Unit Quarter
% Error Quarter
% Error
- A.
-Fission and Activation Products l'.. Total Releases.
' curies 1.33E+00
+1.0E+01' 5.72E-01
+1.0E+01 2.
' Average Diluted Conc. During-Period of.All' Identified'
- Isotopes -
pCi/ml '1.50E-06
-4.19E-07 3.
Percent of~ Applicable Limit 1.95E+01 7.08E+00
([=MPC<1) 1 '-
.i NOTE: Percent of applicable limit'is. based on identified -isotope concentration after dilution, related to their appropriate MPC d to 1.0. concentration and sum of all the isotope fractions com-pare
.B.
Tritium 1.
Total Release Curies :1.15E+02
+1'.0E+01 1.60E+02 11.0E+01 2.
-Average Diluted Conc. During Period' pCi/ml -1.30E-04 1.17E-04
-3.
Percent-of Applicable Limit (3.0E-03pCi/ml)
%I-4.33E+00 3.90E+00 C.
Dissolved and Entrained Gases
~1.
Total Release Curies 2.62E-02-11.5E+01 9.20E-02 11.5E+01 2.
~ Average Diluted Conc. During' 2.96E-08' 6.74E-08.
Period ^
-_ pCi/ml
<3.
. Percent of Applicable Limit (2.0E-04epCi/ml)~
1.48E-02 3.37E-07 D.
Gross' Alpha Radioactivity 1.
Total Releasel Curies :0.00E-01: +1.5E+01: 0.00E-01 +1.5E+01 E.
Volume of Waste' Release
~
(BeforeDilution);
Liters ~7.16E+06 +1.0E+01 5.76E+06 11.0E+01 F.
Volume.of Dilution Water for Period Liters 8.79E+08 -+1.0E+01 :1.36E+09:.+1.0E+01 '
4 J
I_[
- (
, : A.
EFFLUENT!AND WASTE DISPOSAL SEMIANNUAL REPORT BATCH LIQUID RELEASES RADWASTE FIRST HALF 1983 f
First Second G.
Isotope Summary Curies Quarter Quarter 1.
Strontium-89 1.34E-02 0.00E-01 2.
Strontium-90 1.11E-03 7.45E-04 3.
Cesium-134 2.96E-02 1.23E-02 4.-
4.82E-02 2.20E-02 5.
Iodine-131 3.61E-02 2.32E-02 6.
Cobalt-58 4.14E-01 1.22E-01 7.
- Cobalt-60 3.20E-01 1.81E-01 8.
Iron-59 8.34E-03 2.95E-04
-9.
Zinc-65 6.88E-04 0.00E'-01 10.
Manganese.7.'48E-02 7.27E-02 11.
Chromium-51 2.66E-02 8.48E-04 12.
Zirconium-Niobium-95 1.58E-02 3.57E-04
. 13.
' Molybdenum-99 1.97E-04 0.00E-01 14.
Technetium-99m-2.40E-04 1.23E-05 15.
Barium-Lanthanum-140 0.00E-01 0.00E-01 16.
. Cerium-141 0.00E-01 0.00E-01
- 17.
-Sodium-24'
_1.26E-02.'2.30E-03 18.
Fluorine 0.00E-01 0.00E-01 Total.for Period 1.00E+00 4.38E 4- ~
t
'.,.w.
v. :.* :.
t' EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT BATCH LIQUID RELEASES RADWASTE FIRST HALF 1983 First Second 0.
LIsstope Summary Curies Quarter. Quarter
- 0thers(NotRequiredforReg.Ouide1.21) 1; Xenon-133-2.15E-02 7.99E-02 2.-
Xenon-135 4.68E-03 9.88E-03 3.
Iodine-133 1.93E-02 7.01E-03 4.
Cerium-144=
0.00E-01 2.99E-04 5.
' Cobalt-57 1.31E-03 4.92E-04 6.
' Argon-41"
- 9.25E-06 : 3.04E-06 7.
- Xenon-131m 0.00E-01 1.45E-03 8.
Xenon-133m
' 0.00E-01 7.52E-04
- 9.
Tellurium-132 0.00E-01 :2.96E-05:
10.
Krypton-85m' 0'.00E-01 3.50E-05
'11.
Phosphorus-32
' 4.03E-0212.45E-02 12.
Iron-55~
- 2.63E 1.02E-01 13.-
Niobium-97
.2.04E-04.0.00E-01 14.
Silver-110m>
. 4.11E-04 0.00E >
15.
Strontium-92 3.23E-04 0.00E-01 LTotal for Period 3.51E-01T2.26E-01 1
9 r
h i i
1
. ~.
EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT BATCH LIQUID EFFLUENTS - SUMMATION OF ALL RELEASES CONDENSATE REGENERANTS (T0 TURBINE BUILDING SUMP)
FIRST HALF 1983 First Tot'al Second Total Unit Quarter
_% Error Quarter
% Error A.
Fission and Activation Products 1.
Total Releases Curies 0.00E-01 11.0E+01 2.25E-05 11.0E+01 2.
Average Diluted Conc. During Period of All Identified Isotopes pCi/ml 0.00E-01 2.65E-09 3.
Percent of Applicable Limit 0.00E-01 8.82E-01
({MPC < 1) c1 NOTE: Percent of applicable limit is based on identified isotope concentration after dilution, related to their appropriate MPC concentration and sum of all the isotope fractions com-pared to 1.0.
B.
Tritium 1.
Total Release Curies 0.00E-01 11.0E+01 3.27E-01 1.0E+01 2.
Average Diluted Conc. During Period pCi/ml 0.00E-01 3.85E-05 3.
Percent of Applicable Limit (3.0E-03pCi/ml) 0.00E-01 1.28E+00 C.
Dissolved and Entrained Gases 1.
Total Release Curies 0.00E-01 11.5E+01 0.00E-01 11.5E+01 2.
Average Diluted Conc. During Period pCi/ml 0.00E-01 0.00E-01 3.
Percent of Applicable Limit (2.0E-04pCi/ml) 0.00E-01 0.00E-01 D.
Gross Alpha Radioactivity 1.
Total Release Curies 0.00E-01 11.5E+01 0.00E-01 11.5E+01 E.
Volume of Waste Release
.(No Dilution)
Liters 1.60E+07 11.0E+01 8.50E+06.11.0E+01
-F.
Volume of Dilution Water-for Period
. Liters 0.00E-01 il.0E+01 0.00E 1.0E+01
_g_
1
~.A y
7;g.
~
El LU'ENTlAND WASTE D1SPOSAL SEM1 ANNUAL REPORT
(
c-
-BATCH LIQUID' RELEASES
-CONDENSATE REGENERANTS FIRST HALF 1983' First Second
..G.
1sotope Summary Curies Quarter-Quarter u
- 1. -
Strontium-89 0.00E-01 0.00E-01 2.
Stron' tium-90 0.00E-01 0.00E-01 a
3..
Cesium-134' O.00E-01 0.'00E-011 1
-4.
=0.00E-01 0.00E-01 j
5.
LIodine-131 0.00E-01 2.25E 6.
Cobalt-58
-0.00E-01' O.00E-01 g
7.
Cobalt '0.00E-01 0.00E-01 8';
Iron-59 0.00E- 01 0.00E-011 9.
Zinc-65 0.00E-01
- 0. 00E-01..'
' 10.
-. Manganese -
0.00E-01' 0.00E-01.
11.
Chromium-51 0.00E-01 0.00E-01 12.
Zirconium-Niobium 0.00E-01 ~0.00E ~
i-p 13.
Molybdenum 0.00E-01 0.00E-01 i
14.
Tedhnetium-99m 0.00E-01.-0.00E '
l
- 15.-
Barium-Lanthsnum-140 0.00E-01. 0.00E-01 I
- 16.
-Cerium-141'
-0.00E-01 0.00E-01.
- 17..
Sodium-24'
-0.00E-01 '0.00E-01 8
.1.
-Fluorine-18?
~
0.00E-01 -0.00E :
Total for Period-0.00E-01 2.25E i:
- r L
1 L
J,
p g
I<
~
^
~
(,
l
.. a.... ::..
m-EFFLUENT-AND' WASTE DISPOSAL. SEMIANNUAL REPORT-
--BATCH LIQUID RELEASES CONDENSATE REGENERANTS FIRST HALF 1983 First Second G.
Isotope Summary Curies
' Quarter Quarter L
Others (Not Required for Reg. Guidefl.21) 1~..
~ Xenon-133:
0.00E-01.0.00E 2.
- Xenon-135 0.00E-01 -0.00E-01 3.
Iodine-133 0.00E-01 0.00E-01 4.'
Cesium-1361 0.00E-01 0.00E-01 5.
Manganese 0.00E-01 0.00E 6.
- Antimony-122 0.00E 0.00E-01' 7.
- An'timony-124:
0.00E-01 -0.00E-01 8.
Copper-64.
0.00E-01 0.00E-01' 9.
Arsenic-76 0.00E-01 0.00E-01
-10.
Arsenic-74:
0.00E-01 0.00E-01 11.
. Phosphorus 0.00E 0.00E-01 12..
Iron-55' O.00E-01 0.00E-01.
LTotalfor; Period 0.00E-01 0.00E-01.
+
Gil-
},
e
}
f L
i l
F t
t r-h w
e w.,
'i,
e
-- -, y
p w
EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT CONTINU0US LIQUID RELEASES
^
TURBINE BUILDING SUMP FIRST HALF 1983 First Total Second Total Unit
-Quarter
% Error
-Quarter
% Error A.:
Fission and Activation Products-1.
Total Releases?
Curies 0.00E-01 +1.0E+01 0.00E-01 +1.0E+01 2.
A'verage DilutedJConc. During Period of-All Identified Isotopes pCi/ml 0.00E-01 0.00E-01 3.'
. Percent of Applicable Limit-
0.0 0E-01
0.00E-01
.({MPC_<1)
- ,-1 IN0TE: Percent of applicable limit is based on identified. isotope I
concentration after. dilution, related'to their appropriate MPC concentration and sum of all the isotope fractions com -
pared to 1.0.
i
- B.
Tritium'-
1.
. Total Release Curies 0.00E-01.+1.0E+01-1.08E+01 1.0E+01 1
2.
. Average Diluted Conc. During
-Period pCi/ml 0.00E-01 1.99E-05 3.
Percent of Applicable Limit
.(3.0E-03 pCi/ml)
~ %-
0.00E-01.-
6.64E-01 C.
Dissolved and Entrained Gases
. 1.
Total Release.
Curies- 0.00E-01.+1 5E+01.- 0.00E-01~'+1.5E+01 2.
'Averag~e Diluted Conc. During 0;00E-01 Peri ad
- pCi/ml*:0.00E-01 t
3.
Percent of' Applicable Limit-
~
(2.0E-04;pCi/ml) 0.00E-01
- 0.00E-01' D.
Gross Alpha: Radioactivity:
1 1.
Total ReleaseL Curies: 0.00E-01_ 11.5E+01 ;0.00E-01 +1.5E+01 Volume'of Waste Release E.
(No Dilution)
~ Liters 4.70E+08L11.0E+01 5.42E+08 +1.0E+01.
[ '
-w y
Aw
-e m-9 m
y y-ym.
g sa p
?
'. S b.
p71 9
--4s v7
- ..- - -:q
.l i.
... 3 s:. ;
EFFLUENT'AND WASTE DISPOSAL SEMIANNUAL REPORT CONTINU0US LIQUID RELEASES TURBINE BUILDING SUMP
'FIRST HALF.1983 First Second
'G.
Isotope Summary.
Curies Quarter.
Quarter 1.
Strontium-89'
-0.00E-01 0.00E-01
^
2.'
Strontium-90 0.00E-01 0.00E-01
- 3.
' Cesium-134 0.00E-01 0.00E-01~
4.
Cesium-137 0.00E-01 0.00E 5.
Iodine-131-0.00E-01 0.00E-01 16.
Cobalt-58 0.00E-01 0.00E-01 7.
Cobalt-60 0.00E-01 0.00E-01 8.
. Iron-591 0.00E-01 0.00E-01 9.
. Zinc-65 0.00E-01 0.00E-01 10.
- 0.00E-01 0.00E-01 11.
Chromium-51 0.00E-01 0.00E-01
-12.
- Zirconium-Niobium-95 0.00E-01 0.00E-01 13.
Molybdenum-99
'0.00E-01 0;00E ^
14.
LTechn'etium-99m 0.00E-01 0.00E-01 15.-
Barium-Lanthanum-140 0.00E-01 0.00E-01 16.
Cerium-141'
'0.00E-01 0.00E : 17.
. Sodium-24' O.00E-01 -0.00E-0 18.
Fluorine-18 0.00E-01 0.00E-01 Total for Period 0.00E 0.00E,
l 1
3 T-.--
wr
+-1 T
+
+
e
'w-
@#I t 'e.
-EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT CONTINU0US LIQUID RELEASES TURBINE BUILDING SUMP FIRST HALF 1983 First Second G.
Isotope Summary
. Curies Quarter Quarter
'Others (Not Required for-Reg. Guide 1.21) 1.
Xenon-133 0.00E-01 0.00E-01 2.
Xenon-135-
-0.00E-01 0.00E-01 3.
Iodine-133 0.00E-01 0.00E-01 4.
Cesium-136 0.00E-01 0.00E-01 5.
Manganese-56' O.00E-01 0.00E-01 6.
Antimony-122 0.00E 0.00E-01 7.
Antimony-124 0.00E-01 0.00E-01
'8.
Copper-64 0.00E-01 0.00E-01 9.
Arsenic-76
-0.00E-01 0.00E 10.
Arsenic 0.00E-01 0.00E-01 11.
Phosphorus-32 0.00E-01 0.00E-01 12.-
-Iron-55 0.00E-01 0.00E-01 Total for Period 0.00E-01 0.00E-01
. 4
m
-4..,
' N '.
EFFLUENT AND WASTE DISPOSAL. SEMIANNUAL REPORT
' BATCH LIQUID EFFLUENTS - SUMMATION OF ALL RELEASES STEAM GENERATOR BLOWDOWN (T0 COOLING TOWER BLOWDOWN)
FIRST HALF 1983 First Total Second Total Unit-Quarter
% Error Quarter
% Error A.
Fission and-Activation Products E
-1.
Total Releases Curies 5.81E-03 +1.0E+01 8.35E-01 +1.0E+01 2.-
Average. Diluted Conc. During Period of All Identified-Isotopes pCi/ml 2.52E-07 8.45E-07
.3.
Percent:of. Applicable Limit 8.38E-01 5.02E+01-({MPC<1) t-1
' NOTE: -Percent of applicable limit is based on identified isotope concentration after dilution, related to their appropriate MPC concentration and sum of all the isotope fractions com-
-pared to_-1.0.
B.
Tritium 1.
Total-Release Curies 0.00E-01 +1.0E+01 7.80E+00 1.0E+01 2.
Average Diluted Conc. During Period
.pCi/ml 0.00E-01 7.89E-06
~
3.
Percent of Applicable Limit 33.0E-03 pCi/ml)-
0.00E 2.63E-01 C.
Dissolved and Entrained Cases 1.
Total Release Curies" 0.00E-01.-11.5E+01' 1.39E-01' 11.5E+01 2.
- Average Diluted Conc. During-Period pCi/ml 0.00E-01
'1.41E 3.
Percent of Applicable Limit (2.0E-04pCi/al)-
0.00E-01 7.03E-02" De Gross Alpha Radioactivity 1.
Total Release
_ Curies -0.00E-01 +1.5E+01, 0.00E-01 +1.5E+01 E.
Volume of Waste Release
-(Before Dilution)
Liters 1.10E+06 +1.0E+01 ;9.65E+06: 11.0E+01
. F.
" Volume of Dilution Water for Period Liters 2.20E+07 +1.0E+01 9.79E+08' +1.0E+01
=
z 2
s i
EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT BATCH LIQUID RELEASES STEAM GENERATOR BLOWDOWN FIRST HALF 1983 First Second G.
Isotope Summary Curies Quarter Quarter 1.
Strontium-89 0.00E-01 0.00E-01 2.
Strontium-90 0.00E-01 0.00E-01 3.
Cesium-134 0.00E-01 0.00E-01 4.
Cesium-137 0.00E-01 0.00E-01 5.
Iodine-131 0.00E-01 1.01E-01 6.
Cobalt-58 0.00E-01 8.01E-04 7.
Cobalt-60 0.00E-01 0.00E-01 8.
Iron-59 0.00E-01 0.00E-01 9.
Zinc-65 0.00E-01 0.00E-01 10.
Manganese-54 0.00E-01 1.07E-04 11.
Chromium-51 0.00E-01 0.00E-01 12.
Zirconium-Niobium-95 0.00E-01 1.85E-04 13.
Molybdenum-99 0.00E-01 0.00E-01 14.
Technetium-99m 0.00E-01 0.00E-01 15.
Barium-Lanthanum-140 0.00E-01 0.00E-01 16.
Cerium-141 0.00E-01 0.00E-01 17.
Sodium-24 5.81E-03 3.79E-01 18.
Fluorine-18 0.00E-01 0.00E-01 Total for Period 5.81E-03 4.81E-01,
s.
r 3_.~.
~
- EFFLUENT AND' WASTE DISPOSAL SEMIANNUAL REPORT BATCH LIQUID' RELEASES STEAM GENERATOR BLOWDOWN FIRST HALF 1983 First Second
'G.
. Isotope Summary.
Curies Quarter Quarter Others:(Not Required for Reg.' Guide 1.21) 1.
Xenon-133-0.00E-01 1.85E-02 2.-
Xenon-135 0.00E-01 1.20E-01
- 3..
Iodine-133 0.00E-01 1.17E-01 4.
Rubidium-88 0.00E-01 2.22E-02 5.
. Iodine-132-0.00E-01 3.92E-02 L6.
Iodine-135 0.00E-01 8.59E-02
~7.
Iodine-134
-0.00E-01 2.33E-02 8.
Ruthenium-106 0.00E-01 1.89E-02 9.
Zirconium-97 0.00E-01 9.44E-03 10.
Cesium-138 0.00E-01 3.81E-02 11.
Phosphorus-32 0.00E-01 0.00E-01 12.
Iron-55' O.00E-01 0.00E-01 13.
' Argon-41 0.00E-01 6.21E-05 14.
Xenon-135m-0.00E-01 4.92E-05 15.-
Krypton-85m 0.00E-01 9.31E-05 Total for Period 0.00E-01' 4.93E-01.-
= -
EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT GASE0US EFFLUENTS - SUMMATION OF ALL RELEASES (GROUND LEVEL RELEASES)
FIRST HALF 1983 First Total Second Total Summation of All Releases Unit Quarter
% Error Quarter
% Error A.
Fission and Activation Products-1.
Total Releases Ci 4.91E+02 +1.0E+01 1.29E+03 11.0E+01 2.
Average Release Rate for Period pCi/ml 6.31E+01 1.64E+02 3.
Percent of Technical Specifi-cation Limit 2.29E-02 9.64E-02 B.
Iodines 1.
Total Iodine-131 Ci 3.83E-06 11.0E+01 2.40E-04 +1.0E+01 2.
Average Release Rate for Period pCi/sec 4.93E-07 3.05E-05 3.
Percent of Technical Specifi-cation Limit (7.80E-02 pCi/sec) %
6.31E-04 3.91E-02 C.
Particulates 1.
Particulates with half-lives >8 Days Ci 9.59E-08 +1.5E+01 5.77E-04 11.5E+01 2.
Average Release Rate for Period pCi/ml 1.23E-08 7.34E-05 3.
Percent of Technical Specifi-cation Limit 1.93E-05 7.53E-03 4.
Gross Alpha Radioactivity Ci 0.00E-01 0.00E-01 D.
Tritium 1.
Total Release Ci 2.34E+01 +1.0E+01 2.37E+02 11.0E+01 2.
Average Release Rate for Period pCi/sec 3.01E+00 3.01E+01-3.
Percent of Technical Specifi-cation Limit (3.60E+04 pCi/sec) %
8.36E-03 8.36E-02 u
m.
EFFLUENT AND 1ASTE DISPOSAL SEMIANNUAL REPORT GASEOUS EFFLUENTS GROUND LEVEL RELEASE FIRST HALF 1983
'First-Second
!1.
Fission Gases Unit Quarter Quarter
' Krypton Ci 1.48E-01 1.82E-01 Krypton-85m Ci 5.61E-01 ~1.98E+00 Krypton-87 Ci 6.29E-03 2.13E+00
-Krypton-88 Ci 0.00E-01 3.24E+00-
' Xenon-133-Ci 4.73E+02' 1.10E+03
- Xenon-135 Ci 9.42E+00 21.71E+02' Xenon-135m-Ci 0.00E-01 2.55E+00 Xenon-138 Ci 0.00E-01 l'.68E+00
'Others (Specify): Xenon-133m Ci 5.93E+00- 4.29E+00 l
Xenon-131m Ci-2.70E-01 1.10E+00 Argon-41 Ci 1.24E+00- 1.67E+00 Unidentified Ci' O.00E-01 0.00E-01 1
Total for Period 4.91E+02.1.29E+03 2.
- 3.83E-06.2.40E Iodine-133
'Ci 0.00E-01 2.40E-04 Iodine-135 C1 0.00E-01 2.21E-04
- Total'for Period:
3.83E-06 -7.01E-04
~ 19-
rm
- o q
n EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT GASE0US EFFLUENTS GROUND LEVEL RELEASE FIRST. HALF 1983 First Second-
__ 3.
Particulates' Unit Quarter Quarter Strontium-89
.Ci 0.00E-01 1.73E-06 Strontium-90 Ci 9.59E-08 0.00E Cesium-134 Ci 0.00E-01 0.00E-01 Cesium-1371 Ci 0.00E-01 9.28E-10 LBarium-140' Ci 0.00E-01 0.00E-01 Zirconium-95 Ci 0.00E-01 0.00E-01 Niobium-95 Ci 0.00E-01.1.07E-07 Cobalt-58 Ci 0.00E-01 1.47E-04 Manganese-54 Ci 0.00E 0.00E-01 Zinc-65 Ci
'0.00E-01 0.00E-01 Iron-59 Ci 0.00E-01 -0.00E-01 Cobalt-60,
Ci' O.00E-01' O.00E-01 Others (Specify) Ruthenium-106 Ci
-0.00E-01 2.66E-04
-Yttrium-91 Ci 0.00E-01' 1.62E-04
-Lanthanum-140 Ci 0.00E-01 0.00E-01 Total for Period-Ci 9.59E-08 5.77E-04 '
)
EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT SOLID WASTE (RADI0 ACTIVE) SHIPMENTS FIRST HALF 1983 A.
Solid Waste Shipped Off-Site for Burial or Disposal (Not Irradiated Fuel)
First Est. Total Second Est. Total 1.
Type of Waste Unit Quarter
% Error Quarter
% Error a.
Spent resins, filter sludges, m 2.424E+01 N/A 3.427E+00 N/A 3
evaporator bottoms, etc.
Ci 9.585E+02 1.500E-01 4.335E+01 1.500E-01 b.
Dry Active Waste Compressible Waste a
1.614E+02 N/A 1.065E+02 N/A d
Contaminated equip., etc.
Ci 1.743E+01 1.000E-01 4.859E-00 1.000E-01 c.
Irradiated Components, Control m None Nore a
Rods, etc.
Ci None N/A None N/A d.
Other (Describe) m None None a
Ci None N/A None N/A 2.
fn. rate of Major Nuclide Composition (by Type of Waste) 3 pent resins, filter sludges, and evaporator bottoms Unit Ci Unit %
First Second First Second Quarter Quarter Quarter Quarter a.
1.
Chromium-51 4.376E-01 0.000E-01 4.636E-02 0.000E-01 2.
Manganese-54 1.008E+02 4.569E+00 1.068E+01 1.054E+01 3.
Cobalt-58 4.386E+02 1.245E+01 4.645E+01 2.873E+01 4.
Iron-59 1.092E-02 0.000E-01 1.157E-03 0.000E-01 5.
Cobalt-60 3.085E+02 2.003E+01 3.268E+01 4.621E+01 6.
Strontium-90 0.000E-01 0.000E-01 0.000E-01 0.000E-01 7.
Zirconium-95 3.432E-02 0.000E-01 3.635E-03 0.000E-01 8.
Niobium-95 7.126E-01 0.000E-01 7.547E-02 0.000E-01 9.
Iodine-131 0.000E-01 0.000E-01 0.000E-01 0.000E-01
- 10. Cesium-134 3.625E+01 1.999E+00 3.840E+00 4.611E+00
- 11. Cesium-137 5.570E+01 4.193E+00-5.899E+00 9.672E+00
- 12. Other Nuclides 3.095E+00 9.875E-02 3.278E-01 2.278E-01 y
zg q
g,.*
^-y w -
-EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT SOLID WASTE (RADI0 ACTIVE) SHIPMENTS s
FIRST HALF 1983-c 2.
LEstimate of Major. Nuclide Composition (by Type of Waste) :(Cont.)
.b.
DryjActive Waste, Dry ~ Compressible Waste, contaminated equipment, etc.;
.Unitici-Unit %
First Second First Second Quarter Quarter Quarter Quarter
'1.
Chromium-51 3.720E-03 0.002E-01 2.472E-02 0.000E-01 2; Manganese-54:
.5.348E-01 6.092E-01 3.546E+00 1.245E+01 3.
Cobalt-58 9.765E+00 2.570E+00 6.475E+01 5.231E+01 4.
Iron-59 0.000E-01 0.000E-01 0.000E-01 0.000E-01 5.-
4.340E+00 4.802E 2.877E+01 9.773E+00
~
- 6. Strontium-90 0.000E-01 0.000E-01 0.000E-01 0.000E-01 1
7.
Zirconium-95 0.000E-01 0.000E-01 0.000E-01 0.000E-01 8.
Niobium-95 0.000E-01 0.000E-01
'O.000E-01 0.000E-01
.9. LIodine-131' 1.576E-01'6.069E-01 1.045E+00 1.235E+01
- 10.. Cesium-134-6.710E-02 2.693E-01 4.449E-01 5.481E+00
- 11. Cesium-137 1.302E-01 3.779E-01 8.633E-01 7.691E+00'
- 12. Other Nuclides
_4.750E-02 0.000E-01 3.150E-01 0.000E-01 c.
Irradiated Components
.N/A N/A
" N/A N/A-d.
Other -(describe)
N/A~
N/A N/A, N/A t
c L.
g g-I.*.'.'>e,,,,
1
-+
EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT SOLID WASTE (RADI0 ACTIVE) SHIPMENTS FIRST HALF-1983 3.--
-Solid Waste Disposition-t p
Number of Shipments Type Quantity-Mode of Transportation-Destination
.First-Second
= Quarter : Quarter 9
1 LSA Sole Use Vehicle.
Chem. Nuclear Systems Inc.,-Barnwell,,SC.
1 3
LSA Sole Use Vehicle US Ecolo y Richland WA.
B.
-Irradiated Fuel Shipments.(Disposition)
Number of Shipments Type Quantity Mode of Transportation Destination First<
'Second Quarter.- Quarter None None N/A' N/A N/A i
l I <
L.-
.u ~-
~-...-----
- a