D., -.

DUKE POWER GOMPANY P.O. BOX 33180 CHAHLOTTE, N.C. 28242 O'

TEIEPIIONE M ** '

2 = " C ~= =

January 14, 1985 Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulations U. S. Nuclear Regulatory Commission Washington, D. C.

20555

' Attention:

Ms. E. G. Adensam, Chief Licensing Branch No. 4 Re: Catawba Nuclear Station Docket.Nos 50-413 and 50-414

Dear Mr. Denton:

On June 15, 1984, Duke Power Company submitted Revision 10 to the Catawba FSAR. Included in this revision was an updated training program description in Section 13.2.

As a result of discussions with the NRC Staff, it was agreed'that footnotes 4 and 5 on Figure 13.2.2-1.were not consistant with the training program for licensed operators as implemented at Catawba and should be deleted. Therefore, these footnotes will be deleted in Revision 12 to the FSAR as shown on the attached marked up page.

Very truly yours,

& k &&

Hal B. Tucker ROS: sib Attachment cc:

Mr. James P. O'Reilly, Regional Administrator NRC Resident Inspector U. S. Nuclear Regulatory Commission Catawba Nuclear Station Region II 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30323 Robert Guild, Esq.

P. O. Box 12097 Charleston, South Carolina 29412 Palmetto Alliance 1

~

2135b Devine Street Columbia, South Carolina 29205 Mr. Jesse L. Riley i

Carolina Environmental Study Group

'854 Henley Place Charlotte, North Carolina 28207 DR h ho h jf3 PDR

~

e-

a POST OPERA-PERIODIC l-'TYPICALTRA!!!NG/EXPERIENCEPLAN1,-+r4==

PRE OPERATIONAL TRAI%ING-TIONAL TRNG TRAINING MONTHS TO FUEL LOADING 36 5 a 3 2 1 0

Manager GI SP F

GT Superintendent of Admin.

. GT

. SP F

GT Administrative Personnel GT SP' P

F GT Superintendent of Operations GT SP I

P N2 F

GT

. Operating Engineer GT' SP I

R-L P N

a y

pg

+5hift Supervisor /(Group I) GT OR SG 55 NP NF 1

C R-L P N

F L He py F L HS PT,

+ Asst. Shift Supv. (Group II)

GT NP NF I

C R-L P N

F L H8 PT (Group III)

GT I

R-L P N

Reactor Operator (Group I) GT OR SG SS NP-NF I

C R P

N F R He py (Group II)

GT NP NF I

C R P

N F R HS PT.

. (Group III)

GT I

R P

N F R H8 PT Nuclear Equipment (Group I)

GT OR SG 55 NP Nr I.

P F

PT Operator

'(Group II)

GT NP NF I P

F PT (Grow) III)

GT I P

F PT Superintendent.of Tech. Serv.

GT SP P

F GT Performance Engineer GT SP P

F GT Reactor Engineer GT SP P

F GT Test Engineer GT SP P

F GT Performance / Test Technicians GT OR IM8 SP P

F GT Health Physicist GT SP F

GT HP Technicians:

GT OR IN TT BH OJT SP F

GT Chemist GT OJT SP P

F GT Chemistry Technicians GT OR IM 8C TT BC 0JT SP P F

GT Superintendent of Maint.

GT SP P

F GT Maintenance Engineer (Mech.)

GT SP P

F GT Maintenance Engineer (I&E)

GT SP P

F GT Maintenance Engineer (Plan.)

GT SP P

F GT Maintenance Personnel (Mech.)

GT OR IM BM OJT P F

GT Maintenance Personnel (I&E)

GT.

OR IM OJT dE P

F GT GT - General station training' R - License preparation reactor operator SE - Basic instrtmentation and electrical TT - Structured on-the-job training L - License preparation senior operator maintenance OR - Orientation -

PT - Requalification training SP - Special training-Required or cptional by l

SG - Systems and components r eneral -

!H - Introduction to health physics / chemistry management, commensurate with job duties I

55 - Systems and components a wcific BC - Basic chemistry DJT - On-the-job trainirg l

NP - Nuclear Preparatory BH - Basic health physics N - NRC cold license exam NF - Nuclear Fundamentals IM - Introduction to maintenance H - NRC hot license exam I - Introduction to systems and procedures BM - Basic mechanical maintenance P - Participation in preoperational testing C - Cold certification SR0/R0

. + - Senior Operator License required. May and hot functional testing as appropriate l l

- If fuel loading is delayed for more than serve as Senior Operator in Control Room F - Fuel loading (as required)

I one year, requalification training is-initiated.

t Footnote:;:

(

1 - This plan describes a typical training / experience plan prior l

. to fuel load.

STATION TRAINING SCHE 00tt.

l 2 - Shall hold or have held a Senior Reactor Operator License CATAwsA NucutAR STaTW D

3 - P,erformance may received let or 1H__

m Fiqure R2.21 l

5 [?_l_1?h l ele 1...l2 Rev.)tYl2,

' 6 - Indhiduals not cold Itcensed l