ML20111C508
| ML20111C508 | |
| Person / Time | |
|---|---|
| Site: | Oyster Creek |
| Issue date: | 03/04/1985 |
| From: | Fiedler P GENERAL PUBLIC UTILITIES CORP. |
| To: | Zwolinski J Office of Nuclear Reactor Regulation |
| References | |
| NUDOCS 8503150428 | |
| Download: ML20111C508 (17) | |
Text
ENuclear
!#axar""
Route 9 South Forked River,New Jersey 08731-0388 609 971-4000 Wnter's Direct Dial Number:
March 4,1985 Mr. John Zwolinski Chief, Operating Reactors Branch No. 5 U.S. Nuclear Regulatory Commission 7920 Norfolk Ave.
Bethesda, MD 20014
Dear Mr. Zwolinski:
Subject:
Oyster Creek Nuclear Generating Station Docket No. 50-219 License No. DPR-16 Inservice Inspection j
In accordance with 10CFR50.55a(g) and ASME Section XI, IWA-6000 GPU Nuclear is forwarding the Owner's Data Report for Inservice Inspections. This i
report describes examinations performed in conjunction with the Inservice Inspection Program during the Cycle Ten Refueling Outage.
In the event that any comments or questions arise, please contact Mr. Drew Holland of nty staff at 609 971-4643.
Very truly yours,
=
Pefer B. Fiedler Vice President and Director Oyster Creek PBF:rj (#0884A) cc: Dr. Thomas E. Murley, Administrator Region I U.S. Nuclear Regulatory Commission 631 Park Avenue King of Prussia, PA 19406 frt 8503150428 850304 gDR ADOCK 05000219 PDR GPU Nuclear Corporation is a subsidiary of the General Public Utilities Corporation
(
Page 1 of 16 FORM NIS 1 OWNERS' DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules Jersey Central Power & Light Company
- 1. Owner Madison Avenue & Punchbowl Road, Morristown, NJ 07960 (Name and Address of Owner)
Oyster Creek Nuclear Generating Station
- 2. Plant U.S. Route 9. 2 miles South of Forked River. NT OR711 Name and Address of Plant)
Oyster Creek Nuclea(r
- 3. Plant Unit Generating Station $. Owner Certificate of Authorization (if required)
None
- 5. Commercial Service Date 12/23/69
- 6. National Board Number for Unit RX Vessel 14895
- 7. Components Inspected See Page 3 of 16 through 16 of 16 Manufacturer Component or Manufacturer or Installer State or National Appurtenance or Installer Serial No.
Province No.
Board No.
- l Note: Supplemental sheets in form of lists, sketches, or drawings may be used provided (1) size is 8% in. x 11 in.,
(2) information in items 1 through 6 on this data report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
This form (E00029) rnay be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N.Y.
10017
Page 2 ofb 16 FORM NIS-1 (back)
- 8. Examination Dates 1/1/83 to 11/19/84
- 9. Inspection interval from 1974 to loRo
- 10. Abstract of Examinations. Include a list of examinations and a statement concerning status of work required for current interval. Generally, the inservice inspection required for this interval is approximately 34% complete.
- 11. Abstract of Conditionbee remark column on pages 3 through 16.
Noted
- 12. Abstract of Corrective Measures Recommended and Taken See remark column on pages 3 through 16.
We certify that the statements made in this report are correct and the examinations and corrective mea-sures taken conform to the rules of the ASME Code,Section XI.
I Jersey Central Power La a a Date og T 19 I Signed & Light Company By [
Owner Certificate of Autho ation No. (if applicable)
None Expiration Date N/A CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board o(hy ang gres Boil inspectors and/or the State or Province of New JerseV and employed by 3
bc gg eam c_
Hnreford. Conn.have inspected the components described in this Owners' Data Report during the period I/1/83 11/19/84
. and state that to the best of my knowledge and belief, the Owner to has performed examinations and taken corrective measures described in this Owners' Data Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners' Data Report. Furthemtore, neither the Inspector nor his employer shall be liable in any manner for any personalinjury or property damage or a loss of any kind arising from or connected with this inspection.
Date S ~ M ~ 95
.NM Commissions N8.I478 l
[ In 4ce't M Igna~tt[Jd National Board, State Province and No.
1 l
O
NIS - 1 OWNERS DATA REPORT FOR INSERVICE INSPECTIONS
- f 16 P;ge 3
c
.lersey Central Power and Light Company 1.
Owner: Madison Avenue at Punchbowl Road. Morristown. N.107%0 (Name and Address of Owner)
Oyster Creek Nuclear Generating Station 2.
Plant: on U.S. Rt. 9. 2 miles south of Forked River. NJ 08731 (Name and Address of Plant) 3.
Plant Unit: Ovster Creek Nuclear Generalina StaL100 4.
Owner Certificate of Authorization (if required) None 5.
Comunercial Service Date 12/23/69 6.
National Board Number for Unit RX Vessel 14895 IWB-2500 Exam Remarks - S = Satisfactory System Component IWC-2520 I.D. No.
Material Diameter Thickness Method U = Unsatisfactory Reactor Long and B-A 3-564 A-302GR.B CS 228" 7.875" VT" S
Vissel Circ. Shell 2-564 A-302GR.B CS 228" 7.875" VT*
S Welds in Core 564-03 A-302GR.B CS N/A 7.875" VT" S
Renton 565-07 A-302GR.B CS N/A 7.875" VT" S
Reactor Long. Seam B-B 2-563B A-302GR.B CS N/A 7.875" UT S - Examined 100% (to be examined V:ssel Welds next three (3) outages)
Closure Head B-B 574A A-302GR.B CS N/A 5.188" UT S - Examined 10% (12")
Meridonal Welds 574C A-302GR.B CS N/A 5.188" UT S - Examined 10% (12")
574E A-302GR.B CS N/A 5.188" UT S - Examined 10% (12")
Closure Head B-B 2-574 A-302GR.B CS N/A 5.188" UT S - Examined 2% (14")
Cire. Weld ReIctor Vessel to B-C 3-563 A-302GR.B to 228" 7.875" UT S - Examined 33 1/3% (247")
V;ssel Flange Weld A-336, CS Head to Flange B-C 1-574 A-302GR.B to 228" 5.188" UT S - Examined 33 1/3% (247)
Weld A-336. CS Reactor Head to Noz2le B-0 576-01 A-302GR.B CS N/A 5.188" UT S
Vissel Weld 576-07 A-302GR.B CS N/A 5.188" UT S
576-12 A-302GR.B CS N/A 5.188" UT S
Reictor CR0 Penetra-B-E 12 N/A N/A VT" S
VIssel tions In-Core Flux B-E 7
N/A N/A VT*
S Penetrations Vessel Drain B-E Drain A-105-II. CS 2"
.638" VT" S
Instrument B-E 2
P9netrations CR0 Hyd. Return P-P B-F NC-2-2 A106. GR.C 3"
0.300" UT/PT S
" Visual hydrostatic leakage examination
HIS - 1 OWNERS DATA REPORT FOR INSERVICE INSPECTIONS P:ge 4
t'f 16 Jersey Central Power and Light Company 1.
Owner: Madison Avenue at Punchbowl RojuL Morristown. NJ 07960 (Name and Address of Owner)
Oyster Creek Nuclear Generating Station 2.
Plant: on U.S. Pt. 9. 2 miles south of Forked River. NJ 08731 (hme and Address of Plant) 3.
Plant Unit: QXS1;r Creek Nuclear Generatina Station 4.
Owner Certificate s' Authcrization (if required) None 5.
Conumercial Service t..'te _12/21/fi9_
6.
National Board Number for Unit RX Vessel 14895 IWB-2500 Exam Remarks - S = Satisfactory System Component IWC-2520 I.D. No.
Material Diameter Thickness Method U s Unsatisfactory Shutdown P-E B-F NU-1-3 CS to A312 14" 0.750" SS UT/PT S
Cooling P-E B-F Nil-2-2 TP316. SS 14" 0.835" CS UT/PT S
Reictor Closure studs B-G-1
- 2.3.4.6 A-193. CS 6"
54.875" UT S
V;ssel 8 thru 25 length Closure studs &
B-G-1
Nuts (Removed)
Nuts 9.375" length MT S
7.0" Flange B-G-1
Ligaments Closure B-G-1
Bushines N/A lenath Recirculation Pumo Baltina B-G-1 NG01-A SS 2.75" 16.25"lenath UT. VT.SUR S (Pre-service / baseline exami Recirculation Valve Bolting B-G-1 NG02-BE CS 2"
N/A UT VT. SUR S (Pre-service / baseline exam)
NG02-EE CS 2"
N/A UT. VT. SUR S (Pre-service / baseline exam)
NG03-AE CS 2"
N/A UT. VT. SUR S (Pre-service / baseline exam)
NG03-BE CS 2"
N/A UT. VT. SUR S (Pre-service / baseline exam)
NG03-DE CS 2"
NC03-EE CS 2"
Main Steam MSIV Studs B-G-1 V-1-10 CS 2"
N/A UT/VT S
V-1-9 CS 2"
N/A UT/VT S
RX Vessel CRO Boltina B-G-2 49 Sets CS 1.0" N/A VT S
Isslation Valve Bolting B-C-2 V-14-35 CS
.725" N/A VT S
Condenser V-14-36 CS
.725" N/A VT S
V-14-37 CS
.725" N/A VT S
C1:an-up Valve Bolting B-G-2 V-16-1 CS
.500" N/A VT S
Demineralizer V-16-14 CS
.500" N/A VT S
Faidwater Valve Bolting B-G-2 V-2-35 CS 1.0".1.125" N/A VT S
V-2-36 CS l 1.0".1.125" N/A VT S
NIS - 1 ObmERS DATA REPORT FOR INSERY1CE INSPECTIOg$
P ge 5 'af 16 Jersey Central Power and Light Company 1.
Owner: Madison Avenue at Punchbowl Road. Morristown. NJ 07960 (Name and Address of Owner)
Oyster Creek Nuclear Generating Station 2.
Plant: on U.S. Rt. 9. 2 miles south of Forked River. NJ 08731 (Name and Address of Plant) 3.
Plant Unit: Dyster Creek Nuclear Generatina Station 4.
Owner Certificate of Authorization (if required) Kone._
5.
Consnercial Service Date __12/23/69 6.
National Board Number for Unit RX Vessel 14895 IWB-2500 Exam Remarks - S = Satisfactory System Component IWC-2520 I.D. No.
Material Diameter Thickness Method U = Unsatisfactory Main Steam Valve Studs B-G-2 NR-108A CS 1.375" N/A VT S
B-G-2 NR-1088 CS 1.375" N/A VT S
Valve Studs B-G-2 NR-108E CS 1.375" N/A VT S
Reictor Vessel Support B-H 1-569 A-336 202" N/A UT S-Examined 33 1/3% (212")
vassel Welds Q9 A-336 - A2128 202" 1.625" UT S-Examined 33 1/3% f212")
ReIctor RX Vessel B-I-I 2-6" x 6" SS N/A N/A VT S
_yessel Claddina areas Isslation P-E B-J NE-2-48 A312. TP316.SS 10" 0.593" UT S
Condenser E-P B-J NE-2-51 A312 TP316 SS 10" 0.593" UT S
P-E B-J NE-5-8 A312, TP316,SS 10" 0.593" UT S
E-P B-J NE-5-9 A312, TP316,SS 10" 0.593" UT S
E-P B-J NE-5-13 A312. TP316.SS 10" 0.593" UT S
Main Steam P-E B-J MS-1-6 A106, GR.B CS 24" 1.218" UT S
E-P B-J MS-1-7 A106. GR.B CS 24" 1.218" UT S
P-E B-J MS-1-8 A106. GR.B CS 24" 1.218" UT S
E-P B-J MS-1-9 A106, GR.B CS 24" 1.218" UT S
P-E B-J MS-1-30 A106, GR.B CS 24" 1.218" UT S
E-P B-J MS-1-31 A106 GR.B CS 24" 1.218" UT S
E-P B-J MS-1-84 A106. GR.B CS 24" 1.218" UT S
P-E B-J MS-I-85 A106. GR.B CS-24" 1.218" UT S
E-P B-J MS-1-86 A106. CR.B CS 24" 1.218" UT S
NIS - 1 OWNERS DATA rep 0RT FOR INSERVICE INSPECTIONS P7ge 6 hf 16 Jersey Cer. tral Power and Light Company 1.
Owner: Madison Avenue at Punchbowl Road. Morristown. NJ 07960 (Name and Address of Owner)
Oyster Creek Nuclear Generating Station 2.
Plant: on U.S. Rt. 9. 2 miles south of Farked River. NJ 08731 (Name and Address of Plant) 3.
Plant Unit: Ovster Creek Nuclear Gener1 tina Station 4.
Owner Certificate of Authorization (if required) None 5.
Conenercial Service Date 12/23/69 6.
National Board Number for Unit RX Vgsiel 14895 IWB-2500 Exam Remarks - S = Satisfactory System Component IWC-2520 I.D. No.
Material Diameter Thickness Method U = Unsatisfactory RX Head Coolina P-P B-J RHC-2-38 A312. TP316.SS 6"
0.337" UT S
RX Recir-P-E B-J NG-A-24 A312. TP316,SS 26" 1.218" UT S
culation E-P B-J NG-B-24 A312. TP316,SS 26" 1.218" UT S
E-P B-J NG-C-2 A312 TP316.SS 26" 1.218" UT S
E-P B-J NG-D-2 A312. TP316,SS 26" 1.218" UT S
P-E B-J NG-E-24 A312. TP316,SS 26" 1.218" UT S
E-P B-J NG-B-36 A312. TP316.SS 2"
0.218" UT S
E-P B-J NG-D-34 A312. TP316 SS 2"
0.218" UT S
P-E B-J NG-E-37 A312, TP316,SS 2"
0.218" UT S
E-P B-J NG-A-37 A312, TP316,SS 2"
0.218" UT S
P-E B-J NG-B-35 A312. TP316.SS 2"
0.218" UT S
Cltan-up P-E B-J ND-1-3 A312. TP316 SS 6"
0.432" UT S
Deminera112er P-E B-J ND-1-8 A312. TP316,SS 6"
0.432" UT S
E-P B-J NO-1-9 A312 TP316,SS 6"
0.432" UT S
E-E B-J NO-10-3 A312, TP316,SS 6"
0.432" UT S
V-P B-J NO-10-9 A312. TP316.SS 6"
0.432" UT S
Feedwater P-E B-J RF-2-14 A106, GR.B. CS 10" 0.594" UT S
E-P B-J RF-2-15 A106, GR.B. CS 10" 0.594" UT S
E-P B-J RF-2-25 A106, GR.B. CS 18" 0.938" UT S
V-P B-J RF-2-52 A106, GR.B. CS 18" 0.938" UT S
P-E B-J RF-2-53 A106, GR.B CS 18" 0.938" UT S
E-P B-J RF-2-54 A106. GR.R. CS 18" 0.938" UT S
C:re Spray V-E B-J NZ-3-29 A312, TP316,SS 8"
0.500" UT S
V-E B-J NZ-3-56 A312 TP316,SS 8"
0.500" UT S
E-P B-J NZ-3-57 A312, TP316,SS 8"
0.500" UT S
V-TE B-J NZ-3-70 A312. TP316 SS 8"
0.500" UT S
P-E B-J NZ-3-73 A312. TP316,SS 8"
0.500" UT S
E-P B-J NZ-3-78 A312, TP316.SS 8"
G.500" UT S
V-E B-J NZ-3-82 A312. TP316.SS 8"
0.500" UT S
CR0 Hydraulic P-E B-J NC-4-10 A312. TP316,SS 3"
0.300" UT S
Return P-E B-J NC-4-14 A312, TP316.SS 3"
0.300" UT S
E-P B-J NC-4-17 A312. TP316.SS 3"
0.300" UT S
Shut Down V-P B-J NU-1-1 A312. TP316 SS 14" 0.750" UT" S (Pre-Service / Baseline Exam)
Cooling P-P B-J NU-1-2
.A106, GR.C. CS 14" 0.750" UT S
P-E B-J NU-1-16 A106, GR.C. CS 14" 0.750" UT S
E-P B-J NU-1-18 A106, GR.C. CS 14" 0.750" UT S
P-E B-J NU-1-31 A106, GR.C. CS 10" 0.593" UT" S (Pre-Service / Baseline Exam)
P-E B-J NU-1-32 A106. GR.C. CS 10" 0.593" UT*
S (Pre-Service /nauline Exsmi
- Leakage examination performed during hydro
MIS - 1 DWNERS DATA REPORT FOR INSERVICE INSPECTIONS P ge 7
(f _lfL_
Jersey Central Power and Light Company 1.
Owner: Madison Avenue at Punchbani Road. Morristown. NJ 07960
~
(Name and Address of Dwner)
Oyster Creek Nuclear Generating Station 2.
Plant: on U.S. Rt. 9. 2 miles south of Forked River. NJ 08731 (Name and Address of Plant) 3.
Plant Unit: Dyster Creek Nuclear Generatina Station 4.
Dwner Certificate of Authorization (if required) None 5.
Commercial Service Date 12/23/69-6.
National Board Number for Unit RX Vessel 14895 IWB-2500 Exam Remarks - S = Satisfactory System Component IWC-2520 I.D. No, Material Diameter Thickness Method U = Unsatisfactory Shut Down P-E B-J NU-1-38 A106, GR.C. CS 10" 0.593" UT" S (Pre-Service / Baseline Exam)
Cooling E-P B-J NU-1-39 A106, GR.C CS 10" 0.593" UT" S (Pre-Service / Baseline Exam)
(Continued)
P-E B-J NU-1-46 A106, GR.C CS 10" 0.593" UT" S (Pre-Service / Baseline Exam)
E-P B-J NU-l-47 A106, GR.C. CS 10" 0.593" UT" S (Pre-Service / Baseline Exam)
P-V B-J NU-2-1 A312, TP316,SS 14" 0.750" UT" S (Pre-Service / Baseline Exam)
P-E 8-J NU-2-22 A106, GR.C CS 10" 0.593" UT" S (Pre-Service / Baseline Exam)
P-V B-J NU-2-33 A106 GR.C. CS 8"
0.322" UT" S (Pre-Service / Baseline Exam)
V-P B-J NU-2-34 A106. GR.C. CS 8"
0.322" UT" S (Pre-Service / Baseline Exam)
P-V B-J NU-2-35 A106, GR.C. CS 8"
0.322" UT*
S (Pre-Service / Baseline Exam)
V-P B-J NU-2-36 A106, GR.C. CS 8"
0.322" RT*
S (Pre-Service / Baseline Exam)
P-V B-J NU-2-37 A106, GR.C CS 8"
0.322" UT" S (Pre-Service / Baseline Exam)
V-P B-J NU-2-38 A106, GR.C. CS 8"
0.322" RT" S (Pre-Service / Baseline Exam)
P-V B-J NU-3-6 A312 TP316,SS 14" 0.750" UT" S (Pre-Service / Baseline Exam)
P-V B-J NU-4-3 A312. TP316.SS 14" 0.750" UT" S (Pre-Service / Baseline Examl Citan-Up P-V B-J ND-I-4A A312. TP316,SS 6"
0.495" UT" S (Pre-Service / Baseline Exam)
Deminerali2er V-P B-J ND-1-4B A312. TP316,SS 6"
0.440" UT" S (Pre-Service / Baseline Exam)
P-P B-J ND-1-4C A312 TP316,SS 6"
0.495" UT" S (Pre-Service / Baseline Exam)
P-V B-J ND-1-4D A312. TP316.SS 6"
0.475" UT" S (Pre-Service / Baseline Examl RX Recir-P-B B-J NG-E-3 A312. TP316, SS 14" 0.835" UT S
culation Isslation E-B B-J NE-5-29 A312, TP316, SS l'
O.179" PT S
Condenser Main Steam P-B B-J MS-1-63 A106, GR.B. CS 6"
0.432" MT S
P-B B-J MS-1-87 A106. CR.B. CS 2"
0.218" PT S
" Leakage examination performed during hydro
NIS - 1 DWNERS DATA REPORT FOR INSERVICE INSPECTIQg$
Page 8
df 1 Jersey Central Power and Light Company 1.
Owner: Madison Avenue at Punchbowl Road. Morristown. NJ 07960
~
(Name and Address of Dwner)
Oyster Creek Nuclear Generating Station 2.
Plant: on U.S. Rt. 9. 2 miles south of Forked River. MJ 08731 (Name and Address of Plant) 3.
Plant Unit: Dyster Creek Nuclear Generatina Station 4.
Dwner Certificate of Authorization (if required) None 5.
Commercial Service Date _12/23/69 6.
National Board Number for Unit RX Vessel 14895 IWB-2500 Exam Remarks - S = Satisfactory System Component IWC-2520 I.D. No.
Material Diameter Thickness Method U = Unsatisfactory RX Recir-P-B EJ NG-A-20 A312 TP316, SS 2"
0.218" PT S
culation P-B B-J NG-A-38 A312. TP316, SS 2"
0.218" PT S
E-B B-J NG-C-13 A312. TP316, SS 1"
0.179" PT S
B-E B-J NG-C-25 A312 TP316 SS 2"
0.218" PT S
P-B B-J NG-D-35 A312. TP316, SS 2"
0.218" PT S
P-B B-J NC-E-39 A312. TP316. SS 2"
0.218" PT S
C11an-up P-B B-J ND-I-2 A312. TP316, SS la 0.179" PT S
__Demineralizer i
Shut Down P-B B-J NU-1-35A A106, GR.C. CS 1"
0.179" PT S
Coolina Liquid P-E B-J NP-2-6 A312. TP316 SS 1.500" 0.200" PT S
P31 son E-P B-J NP-2-7 A312. TP316. SS 1.500" 0.200" PT S
P-E B-J NP-2-23 A312. TP316 SS 1.500" 0.200" PT S
E-P B-J NP-2-24 A312. TP316. SS 1.500" 0.200" PT S
Ferdwater P-S B-J RF-2-102A A106, GR.C, CS 2"
0.218" PT*
S (Pre-Service / Baseline Exam)
S-P B-J RF-2-102B A106, GR.C. CS 2"
0.218" PT" S (Pre-Service / Baseline Exam)
P-V B-J RF-2-102C A106 CR.C. CS 2"
0.218" PT" S (Pre-Service / Baseline Exam)
V-P B-J RF-2-1020 A106, GR.C. CS 2"
0.218" PT" S (Pre-Service / Baseline Exam)
P-E B-J RF-2-102E A106, GR.C. CS 2"
0.218" PT" S (Pre-Service / Baseline Exam)
E-P B-J RF-2-102F A106, GR.C. CS 2"
0.218" PT" S (Pre-Service / Baseline Exam)
P-V B-J RF-2-102G A106. GR.C. CS 2"
0.218" PT" S (Pre-Service / Baseline Exami RX Head E-P B-J RHC-2-3 A312. TP316. SS 2"
0.218" PT S
Cooling P-E B-J RHC-2-32 A312. TP316, SS 2"
0.218" PT S
E-P B-J RNC-2-33 A312. TP316. SS 2"
0.218" PT S
P-V B-J RHC-2-47 A106 GR.C. CS 2"
0.218" PT" S (Pre-Service / Baseline Exam)
V-P B-J RHC-2-48 A106, GR.C. CS 2"
0.218" PT" S (Pre-Service / Baseline Exam)
P-T B-J RNC-2-49 A106, GR.C. CS 2"
0.218" PT" S (Pre-Service / Baseline Exam)
T-P B-J RNC-2-50 A106. GR.C. CS 2"
0.218" PT" S (Pre-Service / Baseline Exami Is313 tion Support B-K-1 NE-2-S2 N/A N/A N/A UT S
Condenser (nanart B-K-1 NE-5-H1 N/A N/A N/A UT S
Liouid Poison Suonort B-K-1 NP-2-31 N/A N/A N/A UT S
Main Steam Support B-K-1 MS-1-S3 N/A N/A N/A UT S - After Repair Suanert B-K-1 MS-1-S8 N/A N/A N/A UT S
" Leakage examination performed during hydro
NIS - 1 OWNERS DATA REPORT FOR INSERVICE INSPECTIONS Page 9
'o f 16 Jersey Central Power and Light Company 1.
Owner: tildison Avenue at Punchbowl Road. Morristown. NJ 07960
~
(Name and Address of Dwner)
Oyster Creek Nuclear Generating Station 2.
Plant: on U.S. Rt. 9. 2 miles sQuth of Forked River. NJ 08731 (Name and Address of Plant) 3.
Plant Unit: Dyster Creek Nuclear Cencratina Station 4.
Dwner Certificate of Authorization (if required) None 5.
Commercial Service Date _12/23/62_
6.
National Board Nunber for Unit RX Vessel 14895 DB-2500 Exam Remarks - S = Satisfactory System Component IWC-2520 I.D. No.
Material Diameter Thickness Method U = Unsatisfactory Clean-up Support B-K-1 ND-1-H2 N/A N/A N/A UT S
Deminerali2er Feedwater Support B-K-1 RF-2-H27 N/A N/A N/A UT S
Conaart B-K-1 RF-2-H32 N/A N/A N/A UT S
Core Sorav Cuanort B-K-1 N2-3-S7 N/A N/A N/A UT CRO Hydraulic
,juDDort B-K-1 NC-2-14 N/A N/A N/A UT S
Shut Down Support B-K-1 NU-1-H3 N/A N/A N/A UT S
Coolina (nanart B-K-1 NU-1-S1 N/A N/A N/A UT S
RX Head Support B-K-2 RHC-2-H4 N/A N/A N/A VT S - After repair Coolina See_aert B-K-2 RHC-2-H3 N/A N/A N/A VT S - After repair RX Recir-Support B-K-2 NG-A-S3 N/A N/A N/A VT S
culation Support B-K-2 NG-A-S4 N/A N/A N/A VT S
Support B-K-2 NG-A-SS N/A N/A N/A VT S
Support B-K-2 NG-A-56 N/A N/A N/A VT S
Support B-K-2 NG-A-57 N/A N/A N/A VT S
Support B-K-2 NG-B-53 N/A N/A N/A VT S
Support B-K-2 NG-B-S4 N/A N/A N/A VT S
Support B-K-2 NG-B-SS N/A N/A N/A VT S
Support B-K-2 NG-B-56 N/A N/A N/A VT S
Support B-K-2 NG-B-S7 N/A N/A N/A VT S - Replaced cotter pin Support B-K-2 NG-C-S3 N/A N/A N/A VT S
Support B-K-2 NG-C-S4 N/A N/A N/A VT S
Support B-K-2 NG-C-SS N/A N/A N/A VT S
Support B-K-2 NG-C-56 N/A N/A N/A VT S
Support B-K-2 NG-C-S7 N/A N/A N/A VT S
Support B-K-2 NG-A-H3 N/A N/A N/A VT S - After weld repair Support B-K-2 NG-A-H4 N/A N/A N/A VT S - Baseline after pump rebutid Support B-K-2 NG-A-HS N/A N/A N/A VT S - Baseline af ter pianp rebuild Support B-K-2 NG-A-H6 N/A N/A N/A VT S - Baseline after pump rebuild Support B-K-2 NG-A-H7 N/A N/A N/A VT S - Baseline after pump rebuild S"aaert B-K-2 NG-A-H12 N/A N/A N/A VT S - Tiahtened nuts Clean-up Support B-K-2 ND-1-R2A N/A N/A N/A VT S
Demineralizer Support B-K-2 ND-1-H1 N/A N/A N/A VT S
Support B-K-2 ND-1 -H2 N/A N/A N/A VT S
Suaaort B-K-2 ND-10-H1 N/A N/A N/A VT S - Tiahtened put
NIS - 1 OWNERS DATA REPORT FOR INSERVICE INSPECTIONS Page 10 if _11_
Jersey Central Power and Light Company Madison Avenue at p Ochhowl Road. Morristown. NJ 07960 1.
Owner:
g (Name and Address of Owner)
Oyster Creek Nuclear Generating Station 2.
Plant: on U.S. Rt. 9. 2 miles south of Forked River. NJ 08731 (Name and Address of Plant) 3.
Plant Unit: Ovster Creek Nuclear Generatina Station 4.
Owner Certificate of Authorization (if required) None 5.
Consnercial Service Date 12/23/69 6.
National Board Number for Unit RX Vessel 14895 IWB-2500 Exam Remarks - S = Satisfactory System Component IWC-2520 I.D. No.
Material Diameter Thickness Method U = Unsatisfactory Is:1ation Support B-K-2 NE-2-S2 N/A N/A N/A VT S
Condenser Support B-K-2 NE-2-S3 N/A N/A N/A VT S
Support B-K-2 NE-5-SI N/A N/A N/A VT S
Support B-K-2 NE-5-S2 N/A N/A N/A VT S
Support B-K-2 NE-2-H1 N/A N/A N/A VT S - After weld repair Support B-K-2 NE-5-HI N/A N/A N/A VT S - Load indicator adjusted S"aaart B-K-2 NE-5-H2 N/A N/A N/A VT S - Load indicator adiusted Main Steam Support B-K-2 MS-1-S1 N/A N/A N/A VT S
Support B-K-2 MS-1-S2 N/A N/A N/A VT S
Support B-K-2 MS-1-S3 N/A N/A N/A VT S - After repair Support B-K-2 MS 54 N/A N/A N/A VT S
Support B-K-2 MS-1-S8 N/A N/A N/A VT S
Support B-K-2 MS-1-H1 N/A N/A N/A VT S
Support B-K-2 MS-1-H3C N/A N/A N/A VT S
Support B-K-2 MS-1-H4 N/A N/A N/A VT S
C"aaart B-K-2 MS-1-H12 N/A N/A N/A VT S - Af ter floor olate rework F*idwater Support B-K-2 RF-2-S4 N/A N/A N/A VT S
Supoort B-K-2 RF-2-SS N/A N/A N/A VT S
Support B-K-2 RF-2-SSA N/A N/A N/A VT S
Support B-K-2 RF-2-H8 N/A N/A N/A VT S
Support B-K-2 RF-2-H9 N/A N/A N/A VT S
Support B-K-2 RF-2-H11 N/A N/A N/A VT S - Tightened nut Support B-K-2 RF-2-H32 N/A N/A N/A VT S - Load indicator adjusted Sunaart B-K-2 RF-R-4A N/A N/A N/A VT S
Ccre Spray Support B-K-2 NZ-3-S2 N/A N/A N/A VT S
Support B-K-2 NZ-3-S6 N/A N/A N/A VT S - Collar alignment adjusted Support B-K-2 NZ-3-S7 N/A N/A N/A VT S - Tightened bolts / nuts Support B-K-2 NZ-3-H7 N/A N/A N/A VT S
Suonort B-K-2 NZ-3-H8 N/A N/A N/A VT S
Shut Down Support B-K-2 NU-l-SI N/A N/A N/A VT S
Cooling Support B-K-2 NU-1-H3 N/A N/A N/A VT S
S"anart B-K-2 NU-1-H4 N/A N/A N/A VT S
NIS - 1 OWNERS DATA REPORT FOR INSERVICE INSPECTIONS P ge 11 af _11.,__
Jersey Central Power and Light Company 1.
Owner: Madison Avenue at Punchbowl Road. Morristown. NJ 07960 (Name and Address of Owner)
Dyster Creek Nuclear Generating Station 2.
Plant: on U.S. Rt. 9. 2 miles south of Forked River. NJ 08731 (Name and Address of Plant) 3.
Plant Unit: Ovster Creek Nuclear Generatina Station 4.
Owner Certificate of Authorization (if required) None 5.
Comunercial Service Date 12/23/69 6.
National Board Number for Unit RX Vessel 14895.
IWB-2500 Exam Remarks - S = Satisfactory System Component IWC-2520 I.D. No.
Material Diameter Thickness Method U = Unsatisfactory Main Steam Valve B-M-2 V-1-9 CS 24" N/A VT S
Valve B-M-2 V-1-10 CS 24" N/A VT S
Valve B-M-2 NR-108A CS 6"
N/A VT S
Valve B-M-2 NR-1088 CS 6"
N/A VT S
Valve B-M-2 NR-10BC CS 6"
N/A VT S
Valve B-M-2 NR-1080 CS 6"
N/A VT S
Valve B-M-2 NR-108E CS 6"
N/A VT S
Recirculation Valve B-M-2 NG-02-EE SS 26" N/A VT S
Valve B-M-2 NG-03-DE SS 26" N/A VT S
Valve B-M-2 NG-03-EE SS 26" N/A VT S
Clean-up Valve B-M-2 V-16-1
- S 6"
N/A VT S
Demineralizer valve B-M-2 V-16-2 SS 6"
N/A VT S
Valve B-M-2 V-16-14 SS 6"
N/A VT S
Feedwater Valve B-M-2 V-2-35 CS 18" N/A VT S
Valve B-M-2 V-2-36 CS 18" N/A VT S
Isolation Valve B-M-2 V-14-34 SS 10" N/A VT S
Condenser Valve B-M-2 V-14-35 SS 10" N/A VT S
Valve B-M-2 V-14-36 SS 10" N/A VT S
Valve B-M-2 V-14-37 SS 10" N/A VT S
Reactor Internal Areas B-N-1 0" - 360*
N/A N/A N/A VT-3 S
VIssel Above & Below Reactor Core Guide Rods B-N-1 0* - 360*
N/A N/A N/A VT-3 S
Top Guide and B-N-1 N/A N/A N/A N/A VT-3 S
Assed ly Feedwater B-N-1 45*, 135' N/A N/A N/A VT-3 S
Sparger 225*, 315*
Steam Dryer B-N-1 N/A N/A N/A N/A VT-3 S - After repair to bracket welds Shroud Head B-N-1 N/A N/A N/A N/A VT-3 S
and Seoarator
KIS - 1 DWNERS DATA REPORT FOR INSERVICE INSPECT 1QgS Page 12 df 1 Jersey Central Power and Light Company 1.
Dwner: Madison Avenue at Punchbowl Road. Morristown. NJ 07960 (Name and Address of Dwner)
Dyster Creek Nuclear Generating Station 2.
Plant: on U.S. Rt. 9. 2 miles south of Forked River. NJ 08731 (Nase and Address of Plant) 3.
Plant Unit: Dvster Creek Nuclear Generatina Station 4.
Owner Certificate of Authorization (if required) None 5.
Commercial Service Date 12/23/69 6.
National Board Number for Unit RX Vessel 14895 IWB-2500 Exam Remarks - S = Satisfactory System Component IWC-2520 I.D. No.
Material Diameter Thickness Pethod U = Unsatisfactory Reactor Shroud B-N-1 N/A N/A N/A N/A VT-3 S
Vissel (Continued)
Shroud Weld to B-N-1 0* - 360*
N/A N/A N/A VT-3 S
Conical Support Incore Housing B-N-1 N/A N/A N/A N/A VT-3 S
Assembly C.R.D. Assembly B-N-1 N/A N/A N/A N/A VT-3 S
Conical Support B-N-1 0* - 360*
N/A N/A N/A VT-3 S
to Clevis Assembly Shroud Annulus B-N-1 N/A N/A N/A N/A VT-3 S
Surveillance B-N-1 25*, 205*.
N/A N/A N/A VT-3 S
Samples 2958 Fuel Cell B-N-1 N/A N/A N/A N/A VT-3 S
Fuel Support B-N-1 N/A N/A N/A N/A VT-3 S
Castings Control Rod B-N-1 N/A N/A N/A N/A VT-3 S
Guide Tubes Lower Core B-N-1 N/A N/A N/A N/A VT-3 S
Plate Feedwater Spar-B-N-2 45*
135*
N/A N/A N/A VT-1 S - 135* attachment fillet weld ger Brackets 225*, 315*
separation-repair deferred to next outage Guide Rod B-N-2 0* - 180*
N/A N/A N/A VT-1 S
Brackets
NIS - 1 OWNERS DATA REPORT FOR INSERVICE INSPECTIONS page 13 cf 1 Jersey Central Power and Light Company 1.
Owner: Madison Avenue at Punchbowl Road. Morristown. NJ 07960 (Name and Address of Owner)
Oyster Creek Nuclear Generating Station 2.
Plant: on U.S. Rt. 9. 2 miles south of Forked River. NJ 08731 (Name and Address of Plant) 3.
Plant Unit: Ovster Creek Nuclear Generatina Station 4.
Owner Certificate of Authorization (if required) None 5.
Consercial Service Date 12/23/69 6.
National Board Number for Unit RX Vessel 14895 IWB-2500 Exam Remarks - S = Satisfactory System Component IWC-2520 I.D. No.
Material Diameter Thickness Method U = Unsatisfactory Reactor Steam Dryer &
B-N-2 40*. 130*.
N/A N/A N/A VT-1 S
V ssr*
Support Lugs 2208, 3108 (Cor..inued)
Surveillance B-N-2 25*. 205*.
N/A N/A N/A VT-1 S
Sample Holder 295*
Brackets Incore Housings B-N-2 N/A N/A N/A N/A VT-1 S
to peactor Vessel Stub Tube to B-N-2 N/A N/A N/A N/A VT-1 S
RPV Conical Support B-N-2 N/A N/A N/A N/A VT-1 S
to RPV C - arents RX Vessel C.R.D. Pene-B-0 26-51 N/A N/A N/A PT S-Limited exam, permanent support trations B-0 50-27 N/A N/A N/A PT S-obstruction 50% of each weld B-0 26-03 N/A N/A N/A PT S-completed Containment Support C-C 1-1A N/A N/A N/A MT S
Spray Heat Support C-C 1-1B N/A N/A N/A MT S
Exchangers Support C-C 1-1C N/A N/A N/A MT S
Support C-C 1-1D N/A N/A N/A MT S
Su_aaert C-C 1-2A N/A N/A N/A MT S
Is21ation Support C-E-1 NE-1-S1 N/A N/A N/A PT S
Condenser Support C-E-1 NE-2-S8 N/A N/A N/A VT S
Pianort C-E-1 632-R7 N/A N/A N/A PT S
Feed = ter
("aaart C-E-1 RF-2-H26 N/A N/A N/A MT S
C re Spray Support C-E-1 NZ-3-H1 N/A N/A N/A PT S - After weld repair Support C-E-1 N2-2-H22 N/A N/A N/A MT S
Support C-E-1' NZ-2-H24 N/A N/A N/A MT S
Support C-E-l N2-2-H27 N/A N/A N/A MT S
Cuaaart C-E-1 NZ-3-S5 N/A N/A N/A PT S - After weld repair
NIS - 1 OWNERS DATA REPORT FOR INSERVYCE INSPECTIONS P!ge 14 df 1 Jersey Central Power and Light Company 1.
Owner: tiadhan Avenue aLEunchbegl Road. Morristown. N.107960 (Name and Address of Owner)
Oyster Creek Nuclear Generating Station 2.
Plant: on U.S. Rt. 9. 2 miles south of Forked River. NJ 08731 (Name and Address of Plant) 3.
Plant Unit: Dyster Creek Nuclear Generatina Station 4.
Owner Certificate of Authorization (if required) None 5.
Connercial Service Date _12/23/69 6.
National Board Number for Unit RX Vessel 14895 IWB-2500 Exam Remarks - S = Satisfact9ry System Component IWC-2520 I.D. No.
Material Diameter Thickness Method U = Unsatisfactory Containment Support C-E-1 NQZ-l-H14 N/A N/A N/A MT S
Spray Support C-E-l NQZ-1-H9 N/A N/A N/A MT S
Support C-E-1 NQZ-1-HS N/A N/A N/A MT S
Support C-E-1 NO-2-H65 N/A N/A N/A PT S
Support C-E-1 NQ-2-H34 N/A N/A N/A MT S
Connart C-E-l NO-2-H18 N/A N/A N/A MT S
Isolation Support C-E-2 NE-1-H3 N/A N/A N/A VT S-Replaced pin, adj. load indicator
__CQDdenser NE-I-H8 N/A N/A N/A VT S
Fredwater Support C-E-2 RF-2-H23 N/A N/A N/A VT S
Support C-E-2 RF-2-H24 N/A N/A N/A VT S
Support C-E-2 RF-2-H26 N/A N/A N/A VT S
Support C-E-2 RF-2-H28 N/A N/A N/A VT S
Sunnart C-E-2 RF-2-H29 N/A N/A N/A VT S
Ctre Spray Support C-E-2 NZ-2-H2 N/A N/A N/A VT S
Support C-E-2 NZ-2-SI N/A N/A N/A VT S
Support C-E-2 NZ-2-H4 N/A N/A N/A VT S
Support C-E-2 NZ-2-H5 N/A N/A N/A VT S-Tightened nut, adj. load indicator Support C-E-2 NZ-2-H29 N/A N/A N/A VT S
Support C-E-2 NZ-2-H30 N/A N/A N/A VT S
Support C-E-2 NZ-2-H31 N/A N/A N/A VT S
Support C-E-2 NZ-2-H21 N/A N/A N/A VT S
Support C-E-2 NZ-2-H2O N/A N/A N/A VT S-Tightened nut Support C-E-2 NZ-2-H17 N/A N/A N/A VT S
Support C-E-2 NZ-2-H10 N/A N/A N/A VT S
Support C-E-2 NZ-2-S6 N/A N/A N/A VT S-Tightened nut, adjusted snubber Support C-E-2 NZ-2-SS N/A N/A N/A VT S
Support C-E-2 NZ-2-H6A N/A N/A N/A VT S-After rework Support C-E-2 NZ-2-R13 N/A N/A N/A VT S-Tightened nuts Support C-E-2 NZ-2-H32 N/A N/A N/A VT S
Support C-E-2 NZ-2-H33 N/A N/A N/A VT S
Support C-E-2 NZ-2-H38 N/A N/A N/A VT S-Tightened clamp nuts / bolts Support C-E-2 NZ-2-52 N/A N/A N/A VT S
Sunoort C-E-2 NZ-3-H1 N/A N/A N/A VT S-Reclaced ein
MIS - 1 ObalERS DATA REPORT FOR INSERVICE INSPECTIONS Page l _,df _lft_
Jersey Central Power and Light Company 1.
Owner: hadison Avenue at Punchbowl Rcad. Morristown. NJ 07%0 (Name and Address of Owner)
Oyster Creek Nuclear Generatire Station 2.
Plant: on U.S. Rt. 9. 2 miles south cf Forked River. NJ 08731 (Name and Address of Plant) 3.
Plant Unit: Dyster Creek Nuclear Generatina Station 4.
Owner Certificate of Authorization (if required) None 5.
Comunercial Service Date._12/23/69 6.
National Board Ntsaber for Unit RX Vessel 14895 IWB-2500 Exam Remarks - S = Satisfactory System Component IWC-2520 I.D. No.
Material Diameter Thickness Method U = Unsatisfactory Containment Support C-E-2 NQZ-l-H1 N/A N/A N/A VT S
Sprzy Support C-E-2 NQZ-l-H2 N/A N/A N/A VT S
Support C-E-2 NQZ-l-H3 N/A N/A N/A VT S
Support C-E-2 NQZ-1-HS N/A N/A N/A VT S
Support C-E-2 NQZ-1-H12 N/A N/A N/A VT S
Support C-E-2 NQZ-1-S10 N/A N/A N/A VT S
Support C-E-2 NQZ-1-H14 N/A N/A N/A VT S
Support C-E-2 NQ-2-S2 N/A N/A N/A VT S-Tightened bolts / nuts Support C-E-2 NQ-2-SI N/A N/A N/A VT S-Replaced snubber Support C-E-2 NQ-2-H4 N/A N/A N/A VT S
Support C-E-2 NQ-2-S14 N/A N/A N/A VT S
Support C-E-2 NQ-2-S13 N/A N/A N/A VT S
Support C-E-2 NQ-2-S12 N/A N/A N/A VT S
Support C-E-2 NQ-2-S11 N/A N/A N/A VT S-Tightened nut Support C-E-2 NQ-2-S10 N/A N/A N/A VT S
Support C-E-2 NQ-2-H26 N/A N/A N/A VT S
Support C-E-2 NQ-2-H32 N/A N/A N/A VT S
Support C-E-2 NQ-2-H16 N/A N/A N/A VT S
Support C-E-2 NQ-2-H18 N/A N/A N/A VT S
Cupport C-E-2 NQ-2-H61 N/A N/A N/A VT S-After weld repair Support C-E-2 NQ-2-H65 N/A N/A N/A VT S
Support C-E-2 NQ-2-H78 N/A N/A N/A VT S-Replaced pins Containment Support C-E-2 NQ-2-H84 N/A N/A N/A VT S
Spray Support C-E-2 NQ-2-H82 N/A N/A N/A VT S
Support C-E-2 NQ-2-H40 N/A N/A N/A VT S
Sueeert C-E-2 NO-2-H42 N/A N/A N/A VT S
Is21ation R-P C-F NE-1-1 A312. TP316,SS 16" 0.843" UT S-(Augmented exam)
Condenser P-E C-F NE-1-4 A312. TP316 SS 16" 0.843" UT S-(Augmented exam)
P-Y C-F NE-1-6 A312 TP316.SS 16" 0.843" UT S-(Augmented exam)
P-P C-F NE-1-38 A312, TP316,SS 16" 0.843" UT S-(Augmented exam)
P-E C-F NE-1-69 A312. TP316.SS 12" 0.687" UT S-(Augmented exam)
E-P C-F NE-2-19 A312, TP316.SS 8"
0.500" UT S-(Augmented exam)
R-P C-F NE-2-21 A312, TP316,SS 10" 0.593" UT S-(Augmented exam)
P-E C-F NE-2-82 A312. TP316,SS 8"
0.500" UT S-(Augmented exam)
E-P CF NE-2-83 A312, TP316,SS 8"
0.500" UT S-(Augmented exam)
E-P C-F NE-2-94 A312. TP316 SS 8"
0.500" UT S-(Augmented exam)
P-P C-F NE-1-14A A312, TP316,SS 12" 0.687" UT" S-(Pre-service / baseline exam)
E-P C-F NE-1-15 A312. TP316.SS 12" 0.687" UT" S-fPre-service / baseline exam)
" Leakage examination performed during hydro
N11dmICLINSf1CI1ONS PIge 16 gif. 1&__
Jersey Central Power and Light Company I.
Owner: tudison Avenue at Punchbowl Road. Morristown. M.) 07%0 3
(Name and Address of Omner)
Oyster Creek Nuclear Generating Station 2.
Plant: on U.S. Rt. 9. 2 miles south of Forked River. N.1 08731 (Name and Address of Plant) 3.
Plant Unit: Ovster Creek Nuclear Generatina Station 4.
Owner Certificate of Authert2ation (if required) None 5.
Commercial Service Date 12/23/69 6.
National Board Number for Unit RX Vessel 14895 i
IWB-2500 Exam Remarks - S = Satisfactory
+
System Component IWC-2520 I.D. No.
Material Diameter Thickness Method U = Unsatisfactory l1 P-E C-F NE-1-16 A312, TP316.SS 12" 0.687" UT" S-(Pre-service / Baseline Exam)
P-R C-F NE-1-37 A312. TP316,SS 16" 0.843" UT" S-(Pre-service / Baseline Exam)
P-P C-F NE-1-39A A312. TP316,SS 16" 0.843" UT" S-(Pre-service / Baseline Exam)
P-E C-F NE-1-40 A312. TP316,SS 16" 0.843" UT" S-(Pre-service / Baseline Exam)
E-P C-F NE-1-41 A312 TP316,SS 16" 0.843" UT*
S-(Pre-service / Baseline Exam)
P-P C-F NE-1-59A A312 TP316,SS 12" 0.687" UT" S-(Pre-service / Baseline Exam)
P-E C-F NE-1-60 A312. TP316 SS 12" 0.687" UT" S-(Pre-service / Baseline Exam)
E-P C-F NE-1-61 A312. TP316,SS 12" 0.687" UT" S-(Pre-service / Baseline Exam)
P-P C-F NE-1-61A A312 TP316.SS 12" 0.687" UT*
S-(Pre-service / Baseline Exas)
P-E C-F NE-2-12 A312 TP316,SS 8"
0.500" UT*
S-(Pre-service / Baseline Exam)
P-P C-F MIE-2-12A A312 TP316.SS 8"
0.500" UT*
S-(Pre-service / Baseline Exam) 4 E-P C-F NE-2-13 A312. TP316 SS 8"
0.500" UT" S-(Pre-service / Baseline Exam)
P-P.
C-F NE-2-13A A312. TP316.SS 8"
0.500" UT" S-(Pre-service / Baseline Exam) i P-P C-F NE-1-138 A312. TP316,SS 8"
0.500" UT" S-(Pre-service / Baseline Exam)
R-V C-F NE-5-54 A312. TP316.SS 10" 0.593" RT" S-fPre-service / Baseline Exam)
Ccre Spray P-V C-G NZ-1-45 A106, GR.B CS 12" 0.375" UT S-(Augmented exam) f P-E C-G NZ-1-89 A106, GR.B CS 12" 0.375" UT S-(Augmented exam)
P-B C-G NQZ-1-12 A106, GR.B CS 20" 0.375" UT S-(Augmented exam)
P-RT C-G NQZ-1-29 A106, GR.B CS 20" 0.375" UT S-(Augmented exas)
P-B C-G N02-1-40 A106. GR.B CS 12" 0.375" UT S-far
.ted exam) i i
Containment P-TE C-G NQZ-1-54 A106, GR.B CS 20" 0.375" UT S-(Augmented exam)
Spray P-E C-G NQ-2-21 A106, GR.B CS 14" 0.375" UT S-(Augmented exam)
P-E C-G NQ-2-81 A106, GR.B CS 14" 0.375" UT S-(Augmented exam)
P-E C-G NQ-2-95 A106, GR.B CS 14" 0.375" UT S-(Augmented exam)
P-E C-G NQ-2-114 A106, GR.B CS 14" 0.375" UT S-(Augmented exam) l P-V C-G NQ-2-119 A106, GR.B CS 14' O.375" UT S-(Augmented exam)
'l E-P C-G NQ-2-162 A106, GR.B CS 14" 0.375" UT S-(Augmented exam)
TE-E C-G NQ-2-181 A106, GR.B CS 14" 0.375" UT S-(Augmented exam)
.I P-V C-G NO-2-190 A106. GR.B CS 14" 0.375" UT S-Laa m ted exas) i RX Butiding P-R C-G CC-3-12 A106, GR.B CS 8"
0.322" MT S
l Cicsed Cooling E-P C-G CC-3-13 A106, GR.B CS 6"
0.280" MT S
Watcr V-P C-G CC-4-2 A106, GR.B CS 6"
0.280" MT S
P-P C-G CC-4-3A A106. GR.B CS 8"
0.322" MT S
Demineralized PN-R C-G WD-2-8 A106, GR.B CS 6"
0.280" PT S
I Water Transfer P-F C-G 653-2-13 A106. GR.B CS 2"
0.154" PT S
Drywell Floor E-P C-G NV-7-5 A53 GR.B CS 2"
0.154" MT S
& Equipment P-E C-G NV-7-6 A53 GR.B CS 2" -
0.154" MT S
Drains:
P-V C-G NV-7-9 A53, GR.B CS 2"
- 0.154" MT S
i P-E C-G NV-7-16 A53. GA.B CS 2"
0.154" MT S
" Leakage examination performed during hydro l
i 6
.