ML20111C142
| ML20111C142 | |
| Person / Time | |
|---|---|
| Site: | Oyster Creek |
| Issue date: | 03/08/1985 |
| From: | Fiedler P GENERAL PUBLIC UTILITIES CORP. |
| To: | Thompson H Office of Nuclear Reactor Regulation |
| References | |
| GL-84-24, IEB-82-04, IEB-82-4, IEIN-82-11, IEIN-82-52, IEIN-83-45, IEIN-83-72, IEIN-84-23, IEIN-84-44, IEIN-84-47, IEIN-84-57, IEIN-84-68, IEIN-84-78, NUDOCS 8503140427 | |
| Download: ML20111C142 (6) | |
Text
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
e M Huolear ww 88 GPU Nuclear Corporation Forked River,New Jersey 08731-0388 609 971 4000 Writer's Direct Dial Nurr.ber:
March 8,1985 Office of Nuclear Reactor Regulation Attn:
H. L. Thompson, Jr., Director Division of Licensing U.S. Nuclear Regulatory Commission Washington, D. C.
20555
Dear Sir:
Subject:
Oyster Creek Nuclear Generating Station Docket No. 50-219 Response to Generic Letter 84-24 In accordance with your letter of December 27, 1984, GPUN has in place and is implementing an Environmental Qualification Program which to our knowledge satisfies the requirements of 10CFR50.49.
In a recent submittal dated February 22, 1985, GPUN provided qualification status for each of the components on Oyster Creek Environmental Qualification Equipment Master List (EQEML) and Justifications for Continued Operation for those components requiring further qualification efforts. The February 22, 1985 letter also requested schedular extensions for certain pieces of equipment.
The EQEML identifies components which are needed in order to provide a qualified path to safe shutdown as well as equipment required to be qualified for post accident monitoring (RG 1.97) and other plant specific requirements.
Further, GPUN has reviewed the I&E Bulletins and Notices listed in your letter of December 27, 1984. Sunnary information on relevance is provided in ATTACHMENT 1.
Additional infonnation concerning the relevant Bulletin / Notices is contained in the respective EQ file.
Sincerely, 8503140427 850308 PDR ADOCK 05000219 G
PDR Peter r
Director, Oyster Creek Sworn and subscribed to before me this f'^ day of ///auA 1985.
$ % 4MdA>
W@
A/
Notary Public 3gJQ; j^jfg h!y Commission Empires June 9,1986 cc: -Administrator NRC Resident Inspector Region I Oyster Creek Nuclear Generating Station US Nuclear Regulatory Commission Forked River, N. J.
08731 631 Park Avenue King q,f fgggijcJ$cratd#@5 subsidiary of the General Pubhc Utilities Corporation p
ATTACHMENT 1 IE Bulletin SUBJECT APPLICABLE TO REMARKS OYSTER CREEK NGS 82-04 Deficiencies In Primary No The bulletin identifies deficiencies Containment Electrical related to Bunker-Ramo penetration Peneration Assemblies.
ascemblies. Oyster Creek utilizes GE penetration assemblies. As such, this bulletin is not applicable to Oyster Creek.
IE Notices 82-11 Potential Inaccuracies No Oyster Creek is a GE designed Plant.
In Wide Range Pressure As such this notice is not applicable Instruments Used In Westinghouse to Oyster Creek.
nesigned Plants.
55-52 Equipment Environmental Yes The IE Notice provides several EQ Qualification Testing Experience sub-notices related to different types
-Updating Of Test Summaries of equipment. All sub-notices, with Previously Published In 81-29.
the exception of #1, #10 and #11, are not applicable to Oyster Creek.
Notice #1 - Limitorque valve operators. This notice deals with problems encountered by Westinghouse during qualification testing of Limitorque valve operators 'o t
Westinghouse's specified test parameters. Refer to the remarks on IE Notice 83-72 below for the Limitorque valve operators at Oyster Creek. Notice #10 - identifies Viton elastomer ses) failures in ASCO NP-1 solenoid valves which prevent them from changing positions following a radiation exposure in excess of 20 megarads. Oyster Creek uses 2 ASCO solenoid valves with Viton elastomer seals which will be exposed to more than 20 megarads. However, their l
ATTACHMENT 1
-IE Notices SUBJECT APPLICABLE TO REMARKS 82-52 (Continued)
~~
OYSTER CREEK NGS safety function will be performed before a TID of 20 megarads is absorbed. Subsequent failure will not degrade any safety function'or mislead the operator.
Sub-notice #11 - refers to two other IE
- Notices, i.e., 82-03 and 82-11.
IE Notice 82-03 deals with qualification testing and cleanliness of terminal blocks. Qualification testing of terminal blocks is addresse'd below in the response to IE Notice 84-47.
The Oyst.er Creek surveillance and maintenance program addresses cleanliness of terminal blocks.
IE Notice 82-11 is addressed above.
83-45 Environmental Qualification Yes Reference JCO-00-85-24 and 43.
Test Of CE Company "CR-2940" Position Selector Control Switch 83-72 Environmental Qualification Yes The IE Notice provides several EQ Sub-Testing' Experience notices related to different types of equipment. Only the following sub-notices apply to Oyster Creek.
- 1 Anaconda flexible conduit - This notice identifies melting of the conduit during high temperature LOCA testing. Qualified cables preclude the need to qualify the flexible conduit. The Rockbestos cable requalification test program will reinforce the qualification status of their cables which will also preclude the need to qualify the flexible conduit. Reference JCO-0C-85-20.
For Endevco cable reference JCO-0C-85-16.
ATTACHMENT 1 IE Notices SUBJECT APPLICABLE TO REMARKS OYSTER CREEK NGS 83-72 (Continued)
- 12 This sub-notice references IN-83-40 "Need to Environmentally Qualify Epoxy Grouts and Sealers" and IN-83-45 "EQ Test of GE Co. CR-2940 Position Selector Control Switch."
IN-83-40 does not apply to Oyster Creek electrical equipment qualification. See above for the response to IN-83-45.
- 19 ITE Gould circuit breaker - the EQ documentation package is currently under preparation'and will address this sub-notice therein. A type of circuit breaker identified in the notice is used at Oyster Creek.
See JCo-0C-85-21
- 21 Barksdale pressure switches, models B2T and D2H. Oyster Creek utilizes a qualified model B2T.
- 22 Static-0-Ring pressure switches, models 5N and 12N. Oyster Creek uses SOR model 12N. Reference JC0-0C-85-5.
- 24 Limitorque valve operators.
Various concerns identified in the sub-notice have been evaluated and resolved. Further evaluation is currently in progress for applicability to Oyster Creek.
Reference JC0-0C-85-2, 3, 4, 40, 41, 42 and 44.
84-23 Results Of NRC Sponsored No The IE Notice describes the failure of Qualification Methodology two ASCO solenoid valves NP-8316 and Research Test On ASCO Solenoid NP-8344. Neither of these two types Valves are used in a safety application in a harsh environment at Oyster Creek. As such this notice is not applicable, i
m
ATTACHM2NT 1 IE Notices SUBJECT APPLICABLE TO REMARKS OYSTER CREEK NGS 84-44 Environmental Qualification Yes The IE Notice describes QA related i
Testing Of Rockbestos Cables program concerns at Rockbestos which may adversely affect the environmental qualification of their cables. As a result, Rockbestos is currently.
performing a re-qualification-test program. Reference JCO-OC-85-20.
84-47 Environmental Qualification Test Yes The IE Notice describes concerns that Olf Electric Terminal Blocks may exist when terminal blocks are exposed to a steam environment.
t Terminal blocks used in safety related applications in a harsh environment at Oyster Creek have been qualified for i
the conditions they will be exposed to.
84-57 Operating Experience Related Yes Class 1E equipment located in a harsh To Moisture Intrusion In Safety environment at Oyster Creek is Related Electrical Equipment At qualified to the effects of humidity l-Commercial Power Plants during normal / accident conditions.
l 1
When moisture intrusion has been i
exc1'uded or minimized'during i
qualification testing, the manufacturer or GPU recommends the use of seals or installation methods to minimize L
moisture intrusion. EQ related maintenance / surveillance requirements are identified to the Plant on the SCEWs. The preventive actions in IEN-84-57 are under review.
84-68 Potential Deficiency In Yes The concern identified in this notice Improperly Rated Field Wiring To is applicable to a few safety related Solonoid Valves..
solenoid valves at Oyster Creek.
Alternate methods for eliminating the concern are currently under review and will be addressed in the EQ documentation package for each type of solenoid valve affected.
t ATTACHMENT 1 IE Notices SUBJECT APPLICABLE TO REMARKS OYSTER CREEK NGS 84-78 Underrated Terminal Block That No The IE Notice describes a deficiency May Adversely Affect Operation
.concerning Vernitron Incorporated Of Essential Electrical Equipment underrated terminal t' locks used only in Limitorque SMC-04 type motor operators. This type of operator is not used at Oyster Creek. As such, this IE Notice is not applicable.
4