Responsibility 5.1 t

5.0 ADMINISTRATIVE CONTROLS 5.1 Responsibility I

5.1.1 The [ Plant Manager] shall be responsible for overall unit

/

operations and shall delegate "

't N the succession to this l

l responsibility during his absence.

The [ Plant Manager] or his designee shall approve, prior to implementation, each proposed test, experiment or modification to systems or equipment the affects nuclear safety.

5.1.2 The [ Shift Supervisor (SS)] shall be responsible for the control room command function.

During any absence of the [SS] from the control room while the unit is in MODE 1,2,3, or 4, an individual with an active Senior Reactor Operator (SRO) license shall be designated to assume the control room command function.

During any absence of the [SS] from the control room while the unit is in MODE 5 or 6, an individual with an active SR0 license or Reactor Operator License shall be designated to assume the f

control room command function.

l

\\'

l l

l l

1 i

t i

l I

9605140155 960501 PDR ADOCK 05200003 A

PDR k y, Cc9/0;2[Gf

,g00_

5.0-1 07/95 Amendment u

I, Organization 5.2 5.0 ADMINISTRATIVE CONTROLS 5.2 Organization 5.2.1 Oraanizations Organizations shall be established for unit operation and corporate management, respectively. The organizations shall include the positions for activities affecting safety of the nuclear power plant.

a.

Lines of authority, responsibility, and communication shall be defined and established throughout highest management levels, intermediate levels, and all operating organization positions. These relationships shall be documented and updated, as appropriate, in organization charts, functional descriptions of departmental responsibilities and relationships, and job descriptions for key personnel positions, or in equivalent forms of documentation. These requirements shall be documented in the (FSAR];

b.

The [ Plant Manager] shall be responsible for overali safe operation of the plant and shall have control over those onsite activities necessary for safe operation and maintenance of the plant; c.

The (a specified corporate executive position] shall have corporate responsibility for overall plant nuclear safety and shall take any measures needed to ensure acceptable performance of the staff in operating, maintaining, and providing technical support to the plant to ensure nuclear safety; and d.

The individuals who train the operating staff, carry out health physics, or perform quality assurance functions may report to the appropriate onsite manager; however, these individuals shall have sufficient organizational freedom to ensuretheirindependencefgmoperationpressures.

5.2.2 Unit Staff Reviewer's Note:

The final Unit Staff; including the minimum shift crew composition, will be determined based upon the verification and validation results of the process described within SSAR Chapter 18, Human Factors Engineering.

/

(continued) h AP600 5.0-2 07/95 Amendment 0 seanow30 004 r03462006

Organization 5.2 5.2 Organization (continued) 5.2.2 Unit Staff (continued)

~

m The Unit Staff organization shall include the following:

\\

k

\\

i a.

A licensed or senior reactor operator shall be assigned to

}

each reactor containing fuel. This operator may also fill the requirements of section 5.1.2 and other 5.2.2 sections.

I b.

At least one licensed Reactor Operator (RO) shall be present in the control room when fuel is in the reactor.

In addition, while the unit is in MODE 1, 2, 3, or 4, at least one licensed Senior Reactor Operator (SRO) shall be j

present in the control room.

c.

Shift Crew Composition may be less than the minimum requirement of the following table for a period of time not to exceed 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> in order to accommodate unexpected absence of on-duty shift crew members provided immediate action is taken to restore the shift crew composition to within the minimum requirements.

Senior Plant Reactor Reactor Condition Operator Operator MODE 1, 2, 3, or 4 2

1 2

l' MODE 5 and 6 d.

Administrative procedures shall be developed and implemented to limit the working hours of unit staff who perform safety related functions (e.g., licensed SR0s, licensed R0s, auxiliary operators, and key maintenance personnel).

Adequate shift coverage shall be maintained without routine operating personnel work a/e objective shall be to have heavy use of overtime. Th

[12] hour day, nominal 40 hour4.62963e-4 days <br />0.0111 hours <br />6.613757e-5 weeks <br />1.522e-5 months <br /> week while the unit is operating.

However, in the event that unforeseen problems require substantial amounts of overtime to be used, or during extended periods of shutdown for refueling, major maintenance, or major plant modification, on a temporary basis the following guidelines shall be followed:

1.

An individual should not be permitted to work more than 16 hours1.851852e-4 days <br />0.00444 hours <br />2.645503e-5 weeks <br />6.088e-6 months <br /> straight, excluding shift overtime; (continuedD AP600 5.0-3 07/95 Amendment 0 eestrov3\\1004.r03442006 x

Organization 5.2 5.2 Organization (continued) 5.2.2 Unit Staff (continued) 2.

An individual should not be permitted to work more than 16 hours1.851852e-4 days <br />0.00444 hours <br />2.645503e-5 weeks <br />6.088e-6 months <br /> in any 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> period, nor more than 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> in any 48 hour5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> period, nor more than 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> in any 7 day period, all excluding shift turnover time; 3.

A break of at least 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> should be allowed between work periods, including shift turnover time; 4.

Except during extended shut.iown periods, the use of overtime should be considered en an individual basis and not for the entire staff on a shift.

Any deviation for the above guidelines shall be author'ized in advance by the [ Plant Manager) of his designee, in accordance with approved administrative procedures, or by higher levels of management, in accordance with established procedures and with documentation of the basis for granting the deviation.

Controls shall be included in the procedures such that individual overtime shall be reviewed monthly by the [ Plant Manager) or his designee to ensure that excessive hours have not been assigned.

Routine deviation for the above guidelines is not authorized.

CT O The(OperationsManager]shallholdafSROlicense.

e.

g f.

The Shift Technical Advisor (STA) shall provide advisory technical support to the Shift Supervisor (SS) in the areas of thermal hydraulics, reactor engineering, and plant analysis with regard to the safe operation of the unit.

In addition, the STA shall meet the qualifications specified by the Commission Policy Statement on Engineering Expertise of Shif t.

One of the SR0s on shift may perform the functions the STA provided that this individual has the specified engineering expertise.

p h AP600 5.0-4 07/95 Amendment 0 enarrev3\\1806.ro3462006 4

Unit Staff Qualifications 5.3 i'

^

5.0 ADMINISTRATIVE CONTROLS-5.3 Unit Staff Qualifications 1

5.3.1 Each member of the unit staff shall meet or exceed the minimum qualifications of (Regulatory Guide 1.8, Revision 2,1987].