Text

.

6 I

ATTACIIMENT 5 TECHNICAL SPECIFICATION MARK-UPS l

l l

9 a

9605070262 960501 i

PDR ADOCK 05000498 P

PDR TSC-96\\5313.w y

0912 4/22/96

r ST-HL-AE-5313 ATTACHMENT 5 Page 1 of 9 3/_4_.6 CONTAINMENT SYSTEMS 1

3/4.6.1 PRIMARY CONTAINMENT CONTAINMENT INTEGRITY LIMITING CONDITION FOR OPERATION 3.6.1.1 Primary CONTAINMENT INTEGRITY shall be maintained.

APPLICABILITY:

MODES 1, 2,

3, and 4.

ACTION:

Without primary CONTAINMENT INTEGRITY, restore CONTAINMENT INTEGRITY within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

j SURVEILLANCE REOUIREMENTS j

4.6.1.1 Primary CONTAINMENT INTEGRITY shall be demonstrated:

a.

At least once per 31 days by verifying that all penetrations

  • not capable of being closed by OPERABLE containment automatic isolation valves and required to be closed during accident conditions are closed by valves, blind flanges, or deactivated automatic valves secured in their positions, except as provided in Specification 3.6.3; b.

By verifying that each containment air lock is in compliance with the requirements of Specification 3.6.1.3, and]

c.

After cach clecing of cach pcnctration cubject to Typ 0

tccting, Cn cpt the contain=cnt air lechc, if cp ncd j

fc11 cuing : Typc A cr 2 test, by leak rate tccting the scal with gac at a prcccurc not lecc than Pa, and ecrifying that when the =cacured 1cchagc rate for thecc scalc is added to the Icakage ratcc detcr=ined purcuant tc Opccification 4.C.1.2.

fer all cthcr Typc 0 and C pcnctratienc, the cc=hined 1cakage rate ic lecc than 0.00 LO.

  • Except valves, blind flanges, and deactivated automatic valves which are located inside the containment and are locked, sealed or otherwise secured in the closed position.

These penetrations shall be verified closed during each COLD SHUTDOWN except that such verification need not be performed more often than once per 92 days.

SOUTH TEXAS - UNITS 1 & 2 3/4 6-1 Unit 1 - Amendment No.-64, 80 Unit 2 - Amendment No. 64, 69 TSCJ%B313.w 0912 4aMM

ST-HL-AE-5313 ATTACHMENT 5 Page 2 of 9

,Q.ONTAINMENT SYSTEMS i

)

i CONTAINMENT LEAKAGE l

LIMITING CONDITION FOR OPERATION 3.6.1.2 Containment leakage rates shall be limited t-etlh?sd66Edsnds i

Wit,hi:,w, h&,w,+CoEEilsseHB.n,IE,.~EEH@~en.i.R_EEsM_sd_Eih,dIPFoy.eanT""*~~~~

i t.F

-.- - ~.

wa w.

~m

- - ~ ~.

c.

?.. Overall integrated leakage rat cf 1000 than or c:;ual to La, 0.30t by weight of the contain=cnt air per 24 hourc at Pe,-

b.

7. ccmbined Icakage rate of lecc than 0.00 La for all pcnctration: and valvcc cubject tc Typc 0 and C tcctc, when j

prcccuriced to Pa.

APPLICABILITY:

MODES 1, 2,

3, and 4.

ACTION:

With either the measured overall integrated containment leakage rate excceding 0.75 La or the measured combined leakage rate for all alves subj ect tow ~T.g.., pes,.k_w.w.symyRate%T. ts,iww4M:.,,~., i.ng,4 r e o v e r a l'.l.4

- en -

.stw.:.

. y B and C tes exceed La thw,..v.m 1;l.s

..v.,,c~~.n.dv,gi.s.,.w E.h. my. Con. w panetrations a v w.w ore th.ws w :vw.wwa+:,wa.s n..g:ww>tus.. Ret.a:vi n e g r a t e d. i-w~,v.v~.a nm.e.v.nt*Lpwie esk ng: :%gg.,.jgwv.R.agram,

  1. s m w.w

.w

..sw w.

eWa owances y

e ak:wv4E:+.v:

age rate

{:i43m+q Ab.2"%v+p,:gv>.v:s.c.ccc

...an.... ~a and S

,.%4.

e+.. g re s E.u.:-:,.4 sm.

3 ve wlav:

ration subj e. ct to.. :,T,<..ype.,,,B a..nd C the combined leakage rate f o,.r _ al,lss.w.pene.t.,xl3,,,.... s..swwm,,i..

o ram withw_n ira,mmn.ces w z.i..t_.hM...3... hour or.be in at lw.

.,;. i., -. tt.hv..e.

dowa w

_n Con.

..e,.

...ys L.-,s t,s, to _le_c,c. t._h.an.0 0,0,_La.w.o.m ~t.. hvi.

te i n m.e.

2 - aw. m. ~. =

.m eakage3 Rate %Testin..

w.

ETXNDBY"GIthYE'~EhE*gePr.nEME'"g"Eaurs and in COLD SHUTDOWN within the i

east 6

following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

SURVEILLANCE REOUIREMENTS 4.6.1.2 Perform required visual examinations and leakage rate testing, except for contain=cnt air lock testing, in accordance with 10 Cr'n 50,

?-

30 cdified b" u g g g y Q:.ndix J,ggggggggggggggggg[gg

- - -.. a

W.w, ~.w.we?

Y b iw+wAW+ww,w.we hwM mvwu ;4':' a;x*,.wa.w;*... *.Muww4w+usixvm+mawasv..c.

+

wwww:gramPro,,w.ww+,su The provisions of Specification 4.0.2 are not applicable.

SOUTH TEXAS - UNITS 1 & 2 3/4 6-2 Unit - 1 Amendment No. 20, C1, C, 80 Unit - 2 Amendment No. 15,50,C'.,69 TSC-96\\5313 w 0912 4/22/96

I ST-HL-AE-5313 ATTACHMENT 5 Page 3 of 9 CONTAINMENT SYSTEMS CONTAINMENT AIR LOCKS LIMITING CONDITION FOR OPERATION 3.6.1.3 Each containment air lock shall be OPERABLE with:

a.

Both doors closed except when the air lock is being used for normal transit entry and exit through the containment, then at least one air lock door shall be closed, cadj]

b.

Ac cvcr:11 cir lcck Icchag rat cf lecc than er cqual to 0.05 La at "O,.

APPLICABILITY:

MODES 1, 2,

3, and 4.

ACTION:

a.

With one containment air lock door inoperable:

1.

Maintain at least the OPERABLE air lock door closed and either restore the inoperable air lock door to OPERABLE status within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> or lock the OPERABLE air lock door closed; 2.

Operation may then continue until performance of the next required overall air lock leakage test provided that the OPERABLE air lock door is verified to be locked closed at least once per 31 days; j

3.

Otherwise, be in at least HOT STANDBY within the next 6

)

hours and in COLD SHUTDOWN within the following 30 i

hours; and 4.

The provisions of Specification 3.0.4 are not

)

applicable.

b.

With the containment air lock inoperable, except as the result of an inoperable air lock door, maintain at least one air lock door closed; restore the inoperable air lock to OPERABLE status within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

SOUTH TEXAS - UNITS 1 & 2 3/4 6-5 Unit 1 - Amendment No.

6+,

80 Unit 2 - Amendment No. W, 69 BCMU313.w Mt2 4/22N

t l

I ST-HL-AE-5313 ATTACHMENT 5 Page 4 of 9 CONTAINMENT SYSTEMS SURVEILLANCE REOUIREMENTS f

l 4.6.1.3 Each containment air lock shall be demonstrated OPERABLE:

a.

W-ithin 72 hcurc following cach clecing, encept when the air lock ic being uccd for multiple entrica, then at 1cact once

___,,1._..__

u.... _ _....c.,.__

.u....,u...-_. m.. m.,.-

--m.

ym.

..m,

~,

..3 Oc dctcr=incd by precicicn flcw =ccourcm:nts when =cacured

.c _ _

,n.

_____2_

..vv.

t..
t. _.. _,.. _ _

u_...___

t.. _ _ _ _, _ -.

.v.

uw

. w w w s.

wwww..ww w.

w..w wv.s.m, ww w v w w..

s.

www.w ww a.f~es.n. ant.Le c c>.u,re.,n,ot.,w f_,h~e,,sCon,~tni..0 ; NI.T=Y.I.fi,f..f~liEj:$~1 r

10c0 th.an ".

~

conct

.n-

k. a, n,Elnr.acc. or.,d_an...

a nm c Ewi hae,,,,nn,_t,,a,n

,a_n.me.,nt#,.L.,.e,.m.aka,g.eu u._ ate._nT_e._st,ing ER

-w.w a

a xa a

w,~C9nu;f Dr ram b.

"y conducting Overall air lock Icahagc tcct at not lecc than

"; and vcrifying the Overall air lcck icck;;c rat ic within 2_

,2_2 ww

..m.w

,s

___ e

___t._

.. 2 y-.

,-...,. ~

,s

n.._.i _ _

t,.,.2 __ t.. __

m.m.....s.v. u.m..,.i..

v.o. m. e. n. e. m. u...t..__

...3

- ~..

=cintcnancc has becn pcrformed on the air lech that could affect the cir lock cccling capability.

eki.

At least once per 6 months by verifying that only one door in

~

each air lock can be opened at a time.

dB.

By verifying at least once per 7 days that the instrument air pressure in the header to the personnel airlock seals is 2 90 psig.

eg.

By verifying the door seal pneumatic system OPERABLE at least once per 18 months by conducting a seal pneumatic system leak test and verifying one of the following:

1)

That system pressure does not decay more than 1.5 psi from 90 psig minimum within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />, or 2)

That system pressure does not decay more than.50 psi from 90 psig minimum within 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />

\\

--.1._

,ymm.c:_

..n,,._

_c ry... u, _

~

y......,

v.

,,,mm.,.,..

m..

~..

i I

1 i

i

.. m. t.

_____________..___:___,____22..

________1 y. - 3. - y..

v. e.,.. n,..,. vc, n.

.my.,-.m.

s o m...y -.,..

-m

..yy -. m

-m, rie.n,

n..- _

r, n.

m.

i SOUTH TEXAS - UNITS 1 & 2 3/4 6-6 Unit 1 - Amendment No. 51, 00, 80 Unit 2 - Amendment No.

5^,

52, 69 15C.96\\5313.w 0912 4/22/96

ST-HL-AE-5313 ATTACHMENT 5 Page 5 of 9 CONTAINMENT SYSTEMS SURVEILLANCE REOUIREMENTS 4.6.1.7.1 Each 48-inch containment purge supply and exhaust isolation valve shall be verified to be sealed closed at least once per 31 days.

7.t lecct once cr C =cnths en c CTAOCERED TECT DACI#E hid66EdsHudNfE$57ElisTC6hfuliiisshE7fisEEE5EYRufs 4.6.1.7.2

~~

propaa7^EHE"IhB5sYd~difa"TiiiEbisEFa~iT6rsET6ii"9EliT85~Wi t h EEs11 Tent material seals in each sealed closed 48-inch containment purge supply and exhaust penetration shall be demonstrated OPERABLE by verifying that the measured leakage rate is less than 0.05 La when pressurized to Pa.

4.6.1.7.3 At lecct once pcr 3 =cntha Di?AE66fdsfi6ElGLEh7EEs

@${Eij@ppjQagjg!jpggigspg@ygggM[fpg6T6FT8Tinch suppTementary containment purge supply and exhaust isolation valve with resilient material seals shall be demonstrated OPERABLE by verifying that the measured leakage rate is less than 0.01 La when pressurized to Pa.

s 4.6.1.7.4 At least once per 31 days each 18-inch supplementary containment purge supply and exhaust isolation valve shall be verified to be closed or open in accordance with Specification 3.6.1.7.b.

I t

l 1

l 1

1 l

1 SOUTH TEXAS - UNITS 1 & 2 3/4 6-13 I

TSC-96\\$313.w 0912 4/22/96 f

i ST-HL-AE-5313 ATTACHMENT 5 l

Page 6 of 9 j

3/4.6 CONTAINMENT SYSTEMS BASES 3/_4. 6.1 PRIMARY CONTAINMENT 3/4.6.1.1 CONTAINMENT INTEGRITY Primary CONTAINMENT INTEGRITY ensures that the release of radioactive materials from the containment atmosphere will be restricted to those leakage paths and associated leak rates assumed in the safety analyses.

This restriction, in conjunction with the leakage rate limitation, will limit the SITE BOUNDARY radiation doses to within i

the dose guidelines values of 10 CFR Part 100 during accident conditions.

3/4.6.1.2 CONTAINMENT LEAKAGE The limitations on containment leakage rates ensure that the total containment leakage volume will not exceed the value assumed in the safety analyses at the peak accident pressure, Pa (41.2 psig).

As an cdded conservatism, the measured overall integrated leakage rate is further limited to less than or equal to 0.75 La during bef6Es EtidpiihMEhE4U61$tQsiifibyf6146WIEMperformance of th5"psfiodic test Eb ach60Lt~for possible degradst' ion of the containment leakage barriers between leakage tests.

i i

The surveillance testing for measuring leakage rates is consistent with the, requirements of Appendix J cf 10 CFR Part $0% Afp[peEdik$$/ @

bptf6h7Bgair}d{iQppgi@liEgejj[E}i@iQ@jii[ipiiijigjggkapegR,atjejgstli EEOSE*E' 3/4.6.1.3 CONTAINMENT AIR LOCKS The limitations on closure and leak rate for the containment air locks are required to meet the restrictions on CONTAINMENT INTEGRITY cnd containment leak rate.

Surveillance testing of the air lock seals provides assurance that the overall air lock leakage will not become excessive due to seal damage during the intervals between air lock leakage _ tests.

Th^eQinffsilfahdsit:estIWg'sf6EiilEAdHfiin"sDiUDr4#57fitis5 I$5 8:gggggangejpgggg{ngipggd{psyggejjoygjjgggj[MBy~]an poswistehtTsith%thetroquirementsFofMORCFRy50N pendIx Nfgopti6

~

3 /4,6.1. 4 INTERNAL PRESSURE The limitations on containment internal pressure ensure that:

(1) the containment structure is prevented from exceeding its design nsgative pressure differential with respect to the outside atmosphere of 3.5 psig, and (2) the containment peak pressure does not exceed the d2 sign pressure of 56.5 psig during LOCA or steam line break conditions.

The maximum peak pressure expected to be obtained from a LOCA or i

oteam line event is 41.2 psig.

The limit of 0.3 psig for initial positive containment pressure will limit the total pressure to 41.2 psig (Pa), which is less than design pressure and is consistent with j

the safety analyses.

SOUTH TEXAS - UNITS 1 & 2 B 3/4 6-1 Unit 1 - Amendment No. 61 Unit 2 - Amendment No. 50 B C M W 13.w M12 4/2266

f ST-HL-AE-5313 i

ATTACHMENT 5 Page 7 of 9 ADMINISTRATIVE CONTROLS PROCEDURES AND PROGRAMS (Continued) i 10)

Limitation on the annual dose or dose commitment to any MEMBER OF THE PUBLIC due to releases of radioactivity and to radiation from uranium fuel cycle sources conforming to 40 CFR Part 190.

h)

Radioloaical Environmental Monitorino Procram A program shall be provided to monitor the radiation and radionuclides in the environs of the plant.

The program shall provide (1) representative measurements of radioactivity in the highest potential exposure pathways, and (2) verification of the accuracy of the effluent monitoring j

program and modeling of environmental exposure pathways.

The program shall (1) be contained in the ODCM, (2) conform to the guidance of Appendix I of 10 CFR Part 50, and (3) include the following:

1)

Monitoring, sampling, analysis, and reporting of radiation and radionuclides in the environment in accordance with the methodology and parameters in the

ODCM,

\\

2)

A Land Use Census to ensure that changes in the use of areas at and beyond the SITE BOUNDARY are identified and that modifications to the monitoring program are made if required by the results of this census, and 3)

Participation in a Interlaboratory Comparison Program to ensure that independent checks on the precision and accuracy of the measurements of radioactive materials in environmental sample matrices are performed as part of the quality assurance program for environmental monitoring.

i gggjfgf3[ UNITS l' & '2 i'{ { _f '17a UC-96\\5313.w 1010 4/22N6

~

\\

ST-HL-AE-5313 ATTACHMENT 5 Page 8 of 9 ADMINISTRATIVE CONTROLS PROCEDURES AND PROGRAMS (Continued) i)

Diesel Fuel Oil Testina Proaram A diesel fuel oil testing program to implement required testing of both new fuel oil and stored fuel oil shall be established.

The program shall include sampling and testing requirements, and acceptance criteria, all based on j

applicable ASTM Standards.

The purpose of the program is to i

establish the following:

4 4

i a.

Acceptability of new fuel oil for use prior to addition j

to storage tanks by determining that the fuel oil has:

4 1.

an API gravity or absolute specific gravity within

limits, 1

l 2.

a flash point and kinematic viscosity within limits for ASTM 2D fuel oil, and l

3.

a clear and bright appearance with proper color; b.

Other properties for ASTM 2D fuel oil are within limits i

within 30 days following sampling and addition to storage tanks; and c.

Total particulate concentration of fuel oil is s 10 mg/l when tested every 31 days using a test method based on ASTM D-2276.

1 SOUTH TEXAS - UNITS 1 & 2 6-18 Unit 1 - Amendment No. 17, 57, 68 Unit 2 - Amendment No. 20, 15, 57 TSOMB313.w 0912 4/22S 6

r i

e i

ST-HL-AE-5313 I

ATTACHMENT 5 Page 9 of 9 ADMINISTRATIVE CONTROLS i

l PROCEDURES AND PROGRAMS (Continued) 1

(*P3 W "E*ShesaE17 "51bo~~n~FaTn'm^e~n~E5-fFaYa""a~e~"r~ Rate ~nT"es"Ern~o~~F

~ro~~a~'~~a~m^

-I

  • N

^~~

P r

ddad 4

,s ed7w-l,b,y s.,

b..s,l.:.ci,.h. ei. c..u ce,-,o ri-,.,l.;n.-.,_, ~.yth,e..;,,b:y@m

-,,.n

,t,.y,3 An.-,,_,- ~n.,s ah..,_ nl..,4 y.a.rogr,gofgth: espr.e.+w.mm,:

. se ti,a.

mp e e ts,udfd.y,

at 0R.;gesra e

.q u

sw w e a

+.* pr..qing,. a,m..:. 7:

a, imaryg,,:conta nmentaasg,3..m.j n.ss ee.qgx require s

~%

. CFR,j;m p

o x

tes,t 50 f5Co)$An#s10ACFRiSOMAppssdiWMopslos%MasW6difisd!Ey, 1

withe mn.p.m, a,s.,,z,.,qim ipsi..e...n. wo+W.w.AThis @yd, " n,*% Reg;u h.ypf6vs4f. e d

F r a+m M..h. a

%efi.s, %d2,.;.:e6. s.f.m.p. n.s..da aE*~

l E

is eigu delin,. g Auw.mnosycontaine i va f atory).gGu3q; ide W 163)m w

6g;g?,s6,,p,f,E,,.ygs;;gf g.w,gyg E.;,3,;.3niWidAE

) Py o.s..gs f.:6.3rmi.,.n,.,.d. s,.?Ba.ssd @6ndsi.3.w.yy,,,es.;wwymy,s.;;.m,gwam,.ii,,%.y hm

@ Ls kkTset v

=-m x

yxq,;%,.,,

Sert _omb_n.-

e_r4, 1995^cw-- n Pe,.pa,kga l,cu.,lnt.;nd.;:.f.:np..y.s,f,.;.-

a e e rima.n--s-nta.;,i.. --, ht,,y<n.:n.sg,t.n.n,Ly,re.;os,,v _,,e.f, o,.- 7,hn

_n

~

i ern - -

p-..

sure w r=t

c. a.ba:p.>..:is,q.:l,+ e g....yi,c.;o.::.:, secoolantxa.m.;y,u.e ide;.sntd.;. - - - aLOCM> ;>; ppa el. j.s ;

.r. rsg.

.c.ms;<wu,e.g r.,.

r n.. n

.s u

7 des. ig<o.

- y s

-7 ne' s

y ossio p$Ewww-sME2 c,c.ew.w.w.+/;m.A+w,vw o,wie4hb.6k.;ww.w4;w;w:m.>hn:wche

%s44

>4

- '~-- ^m:

ss :.w.is_ ?

v THsTssWIi. ius_ Win,,~6.s&ET_s7.p_fli,n_m,i_fp,765,hEs.is. ~asHEWe s

A i_suoy~- f e

m _yst,M u*p _ rima _ry ~s.co _ntai entwai.n_w.. i'g_ht_s_rm p e _r; w

e 1

..m..sk.v +..m..Tr_:.r. teTa,w,c.e ow~.ww;.u.;iwwi_.E_er.,i_ecc.m. eqawa_r_e_t m

ex Lea._ age _ a e ~vc eRc_anc_e c_r e

~

sm

- n

~-.w-tn.,in.

hn,-

. l.l,.nl.,, k,a,w e.nr unto,n.w.n,,,., Ew.,,-mrs t;>;p

,,.w.x

_s

, Prim.ee v.

overa s ea s

,x.y. ra sacc s

w an a

acon a nmen minsacc-..ri. 4wth+g v, w

++-+ m,,o.:w eg.gj y 3sg; f

- 9 g+4ssy -

/

v:* ~m>

s okpL m;D<pu-ngs eefix m sun ts..startMu.p l

m a;.*a m o

sx cr,it,er ni l_on_owi_on. ;%,s,e_sm.

eprater,tism.%.sm,,a,4.ssm s

u acceptancer,o.x._rda_n.c.

i_.s.~d.,, h,dhi,n,gp.,o.,w.

,.nd> h,e,,

e s

f n..sgit,mee t e r i a. g a,.;,m sz mre m 0M0.rogra.mporsthe ngn ew em m e.

m.

ge.wdR;d.p peakag_ii@ J v

crim Danf

-vMM6d IMAS$i4EPT isBysndlTypslCIEesE,Ma.pwav.vo.w,.iMlN6.mwo.%:e;%* A s

glii.n wm-amma-2 o' m a?AssFO' UNDi..fo:sm,.

Namswww;Mx+xw an f '~ L;

c~.e-+

Nr s

n

-wu p..ex nw r4T...

- mm - M L.ypeX tests 2

- m mmmu w

mm uhu.mAmiwenyl,o.wm~k^s:etmvE,e.yivum.: maw-4w,.we%e-my+c.,ei.t,.,w.v.wi~a~m.t,,o-w dw /hww:r,w~u,w.we.sliwsai,.y ngn c, e w

ga n

r eaovera e r vgg>:g

-.a_kagm_a_te i,.c,.a.~p,t,ances r, e,r,te_s_ted~ amu,==.~,.wausw

. c a es

. n, A,n ~"ln,w nun,

a

.v n e

~n

-~,,c e

eir swaoron

_s aatnM_P.m r a

mm

_ mm m

m i

ti_y; -_,_, _.; m i.,g_at.n.v.a_.un.g, _.H. :po+m,i.m_u <i,._

wm%.r: wo+i.mi*on.ms o M.g +>ww.eo

_ance qu

_m...__

..: pag 2 Ano 3._

ewmw.

y3pn.w, x4e4

.rw s

u.

a,_i n_m a a,. gL _..

,a ts e a

, o.c.

l eryals i n:

R_at g/;

nann;sunnuuma a; r

a

~

t i n g g P r _o g _r a n k 1

ai..o..v. v,al. -.y-fg*S.u,m

e. n.,,h.. my 9 - e

.yi. ___E%d.qA.,by m-akagetRateNTOStin.,equ,r,n~xxas,a m

. tm.m i,h,,e,

-.x,-

nment$Le,ns+o_asn. rv,x,.xl a.r..n c.~e R emen a

im~,o,ns. s

, o sw.at x,a

., ap.cr S

r u

~

n xer v

>ua Cont,4;e4MhMv4w:

P r og r m 'h.

oMmnam;&u+.. AkWWh4ahsEWmuoRMW>k Asmw4w 48ame..xMk*ek 4

i j

^

4

.S. OUTHIT _EXAS MUNITSFI.m.m _2P "S_lf36. 18 A M

--- u m -m2m-~~~m.

.m m-wow ~

a TSC-96\\5313.w 0912 4/22/96

-