h i

' DukeIbwerCompany MSnum P.O. Box 1006 Senior VrcePresident i

i Charlotte, NC282011006 Nuclear Generation i

l (704)3822200 Of(tce

{

i (704)3824360 Fax

)

i DUKEPOWER 4

l l

April 30, 1996 l

l U.

S.

Nuclear Regulatory Commission ATTENTION:

Document Control Desk l

Washington, DC 20555-0001 l

3

SUBJECT:

Duke Power Company

)

j l

McGuire Nuclear Station - Unit 1 l

Docket No. 50-369 Catawba Nuclear Station - Unit 2 l

Docket No. 50-414 l

Response to NRC Bulletin 96-01 Additional Information i

In a letter dated April 4, 1996, Duke Power responded to NRC Bulletin 96-01.

In this response Duke stated that core maps for t.vo' future core designs (McGuire 1 Cycle 12 and Catawba i

i 2 Cycle 9) would subsequently be provided to the NRC.

These two future core designs are now complete and the requested information is included as Attachment 1 to this letter.

These additional core designs complete the Duke submittal of the information requested in Response Item 2 of NRC Bulletin 96-01.

Please direct questions on this matter to J. S. Warren at l

(704) 382-4986.

l I declare, under penalty of perjury, that the statements set forth herein are true and correct to the best of my knowledge.

Very truly yours, 4

[,

k0vu M.

S.

Tuckman i

000128 9605060340 960430 PDR ADOCK 05000369-s[

G PDR J

\\ 0 l

wm x am me

\\

U.

S. NRC, Document Control Desk

. ~ April 30, 1996 Page 2 i

l MST/JSW l

ATTACHMENT 1:

Additional Information for NRC Bulletin 96-01, Required Response Item 2 Core Map for McGuire Unit 1 Cycle 12 l

Core Man for Catawba Unit 2 Cycle 9 (3 PageJ) i xc:

S.

D.

Ebneter, Regional Administrator U.S. Nuclear Regulatory Commiss.4.on, Region II R.

E. Martin, NRC Project Manager (CNS)

V.

Nerses, NRC Project Manager (MNS) l l

ONRR R. J.

Freudenberger, NRC Resident Inspector (CNS)

G.

F. Maxwell, NRC Resident Inspector (MNS) l Duke Nuclear Sites l

i l

i I

I t

e ATTACHMENT 1

' "Page'1 of 3 McGuire/ Catawba r

l t

RCCA Placements H

G F

E D

C B

A l

..............e.......ee...e.eeeeeeeeeeeeeee..................

e e

e e

08

  • Control *
  • Control *
  • Shutdown *
  • Control
  • I D

A E

c I

e e

e

... 99 e

09 *

  • shutdown
  • l B

e e

e e

........e

....ee....e

.........................$e........................

e e

e e

e e

e e

e 10

  • Control *
  • Control *
  • Control
  • A C

B e

e e

e e

e e

e e

.....................................e...........................................

e e

e e

11 *

  • Shutdown
  • e e

e e

e c

e e

e e

e e

e e

e e

e

........................................e

.........ee........eee.................

e e

e e

l 12

  • Shutdown *
  • Control *
  • Shutdown
  • E D

A e

e e

e e

e e

e

..........................ee...........................................

e e

e e

13 *

  • Shutdown *
  • shutdown
  • l e

B D

e e

e e

e e

e e

eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee...eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee

~

e e

e e

e e

e 4

14

  • Control *
  • Control *
  • Shutdown *
  • RCCA Locations j

C B

A e

e e

eeeeeee....

ee.....

e..ee....

ee...eeeeeeeeeeee eeeeee...

e e

e 15

  • e e

e e

e

.eeeeeeeeee....eeeee eeeee......

eeee s

o l

b

- _~_

e l

ATTACHMENT 1 M1C12 RADIAL EXPOSURE DISTRIBUTION

.& Page *2 of 3 BOC:

STATEPOINT 1(

.00 EFPD) WRITTEN BY CNRQ/08APR96 SIMEDIT JOB EOC:

STATEPOINT 14 (380.00 EFPD) WRITTEN BY CNRQ/08APR96 CPKH/10APR96 H

G F

E D

C B

A

  • 32.8068 *

.0000

  • 17.7205
  • 14.7684
  • 16.6587
  • 16.6447
  • 17.7950
  • 28.3021
  • i 08
  • 47.1196
  • 19.1372
  • 35.0189
  • 32.2076
  • 33.9512
  • 32.9590
  • 31.1911
  • 34.9660 *

{

{

14.3128

  • 19.1372
  • 17.2983
  • 17.4392
  • 17.2924
  • 16.3143
  • 13.3961
  • 6.6640
  • 11 14 13A 13B 13B 13B 13A 12 l

.0000

  • 31.2855 *

.0000

  • 25.7117 *

.0000

  • 17.8842 *

.0000

  • 24.7764
  • 09
  • 19.1280
  • 46.4723
  • 19.2684
  • 41.8714
  • 19.0136
  • 34.4251
  • 16.3949
  • 32.0911
  • 19.1280
  • 15.1868
  • 19.2684
  • 16.1597
  • 19.0136
  • 16.5409
  • 16.3949
  • 7.3148
  • 14 12 14 12 14 13A 14 12 l
  • 17.7200 *

.0000

  • 31.2742 *

.0000

  • 25.4295 *

.0000

  • 15.7727
  • 17.4946
  • I 10
  • 35.0161
  • 19.2948
  • 46.6259
  • 19.5061
  • 41.8960
  • 19.0736
  • 30.3075
  • 24.9436
  • 17.2961
  • 19.2948
  • 15.3518
  • 19.5061
  • 16.4666
  • 19.0736
  • 14.5348
  • 7.4491
  • 13A 14 12 14 12 14 13B 13A

]

                                      • =*******.. ************************e
            • e****************

j

  • 14.7687
  • 25.7107 *

.0000

  • 17.2810 *

.0000

  • 17.5285 *

.0000

  • 28.5555
  • 11
  • 32.2067
  • 41.9174
  • 19.5254
  • 35.2054
  • 19.4572
  • 34.0917
  • 15.4102
  • 33.9388
  • f 17.4379
  • 16.2067
  • 19.5254
  • 17.9244
  • 19.4572
  • 16.5631
  • 15.4102
  • 5.3832
  • 13B 12 14 13A 14 13A 14 12
  • 16.6589 *

.LS00

  • 25.4349 *

.0000

  • 14.7592 *

.0000

  • 17.6941
  • 12
  • 33.9506
  • 19.0402
  • 41.9077
  • 19.4421
  • 32.8331
  • 17.4503
  • 27.1433
  • 17.2918
  • 19.0402
  • 16.4728
  • 19.4421
  • 18.0740
  • 17.4503
  • 9.4493
  • 13B 14 12 14 13B 14 13A
  • 16.6448
  • 17.8965 *

.0000

  • 17.5259 *

.0000

  • 11.0462
  • 31.9085
  • 13
  • 32.9596
  • 34.4306
  • 19.0752
  • 34.0915
  • 17.5051
  • 23.0517
  • 36.6182
  • l 16.3148
  • 16.5342
  • 19.0752
  • 16.5655
  • 17.5051
  • 12.0054
  • 4.7097
  • 13B 13A 14 13A 14 13A 12
  • 17.7916 *

.0000

  • 15.7774 *

.0000

  • 17.5910
  • 31.9111
  • 14
  • 31.1877
  • 16.3919
  • 30.3134
  • 15.4284
  • 27.1027
  • 36.6755
  • 13.3961
  • 16.3919
  • 14.5360
  • 15.4284
  • 9.5117
  • 4.7644
  • 13A 14 13B 14 13A 12
                                                                                                    • w**********

J 28.3019

  • 24.7824
  • 17.5203
  • 28.5599
  • BOC Exposare (GWD/MTU) 15
  • 34.9664
  • 32.0964
  • 24.9673
  • 33.9476
  • EOC Exposure (GWD/MTU) 6.6645
  • 7.3140
  • 7.4470
  • 5.3877
  • Cycle Exposure (GWD/MTU) 12 12 13A 12
  • Fuel Batch Label FUEL BOC EOC CYCLE BATCH # ASSYS BURNUP BURNUP BURNUP

=

=_

11 1

32.8068 47.1196 14.3128 12 52 27.9725 38.5403 10.5679 4

13A 48 17.0813 30.4717 13.3903 13B 24 15.7302 32.0952 16.3650 14 68

.0000 18.2594 18.2594 TOTAL 193 13.9109 28.6310 14.7201 l

- ~,

e ATTACHMENT 1 u Pags,3 of 3 C2C09 CORE MAPS a

BOC: STATEPOINT 1(

.00 EFPD) WRITTEN BY BQDT/08 MAR 96 SIMEDIT JOB EOC STATEPOINT 15 (475.00 EFPD) WRITTEN BY BQDT/08 MAR 96 CQBG/08 MAR 96 H

G F

E D

C B

A

  • 33.5946 *

.0000

  • 28.5532 *

.0000

  • 28.5510 *

.0000

  • 21.6077
  • 22.0534
  • 08
  • 51.8822
  • 24.0766
  • 46.9522
  • 24.0365
  • 46.8481
  • 23.7644
  • 39.1698
  • 31.5062 *
  • 18.2876
  • 24.0766
  • 18.3990
  • 24.0365
  • 18.2971
  • 23.7644
  • 17.5620
  • 9.4529
  • 8 11A 9B 11A 9B 11B 10 10 w

.0000

  • 22.0538 *

.0000

  • 21.8997 *

.0000

  • 19.0793 *

.0000

  • 31.6590
  • 09
  • 24.0813
  • 43.4517
  • 24.2725
  • 43.4744
  • 23.8583
  • 40.4840
  • 21.0036
  • 40.1798 *
  • 24.0813
  • 21.3980
  • 24.2725
  • 21.5747
  • 23.8583
  • 21.4047
  • 21.0036
  • 8.5208
  • 11A 10 11A 10 11A 10 113 9A
      • e
      • e.......
  • 28.5532 *

.0000

  • 33.2757 *

.0000

  • 21.4207 *

.0000

  • 12.6998
  • 22.2713
  • 10
  • 46.9457
  • 24.2638
  • 51 9497
  • 24.0065
  • 43.2785
  • 23.1542
  • 31.4971
  • 31.5376 *
  • 18.3925
  • 24.2638
  • 18.6740
  • 24.0065
  • 21.8579
  • 23.1542
  • 18.7973
  • 9.2663
  • 9B 11A 9A 11A 10 11A 10 10

.0000

  • 21.9772 *

.0000

  • 19.0538 *

.0000

  • 17.7307 *

.0000

  • 29.3902
  • 11
  • 24.0203
  • 43.5250
  • 23.9946
  • 41.1427
  • 23.3803
  • 38.5221
  • 19.4235
  • 35.7086 *
  • 24.0203
  • 21.5479
  • 23.9946
  • 22.0888
  • 23.3803
  • 20.7914
  • 19.4235
  • 6.3184
  • 11A 10 11A 10 11A 10 11B 9C 1
  • 28.5510 *

.0000

  • 21.4197 *

.0000

  • 21.4384 *

.0000

  • 21.9188
  • 12
  • 46.8395
  • 23.8503
  • 43.2743
  • 23.3bs0 * ~2.uS17
  • 21.2709
  • 33.4002 *
  • 18.2885
  • 23.8503
  • 21.8547
  • 23.3898
  • 20.6133
  • 21.2709
  • 11.4815
  • 9B 11A 10 11A 10 11B 10

.0000

  • 19.0800 *

.0000

  • 17.7323 *

.0000

  • 19.0468
  • 32.3052
  • 13
  • 23.7608
  • 40.4830
  • 23.1573
  • 38.5368
  • 21.2943
  • 32.4854
  • 37.6877 *
  • 23.7608
  • 21.4029
  • 23.1573
  • 20.8046
  • 21.2943
  • 13.4386
  • 5.3825
  • 11B 10 11A 10 11B 10 8
                                                • e
  • 21.6077 *

.0000

  • 12.7037 *

.0000

  • 21.9241
  • 32.3754
  • 14
  • 39.1699
  • 21.0053
  • 31.5061
  • 19.4331
  • 33.4124
  • 37.7556 *
  • 17.5622
  • 21.0053
  • 18.8024
  • 19.4331
  • 11.4884
  • 5.3802
  • 11B 10 11B 10 8

10

                                                                                • =**

..e**

  • 22.0534
  • 31.6656
  • 22.2053
  • 29.3627
  • BOC Exposure (GWD/MTU) 15
  • 31.5067
  • 40.1880
  • 31.4831
  • 35.6878
  • EOC Exposure (GWD/MTU)
  • 9.4533
  • 8.5224
  • 9.2779
  • 6.3250
  • Cycle Exposure (GWD/MTU) 10 9A 10 9C
  • Fuel Batch Label ee........

e***********

FUEL BOC EOC CYCLE BATCH # ASSYS BURNUP BURNUP BURNUP 8

9 32.4797 39.2950 6.8154 9A 12 32.2001 44.1058 11.9057 9B 8

28.5521 46.8964 18.3443 9C 8

29.3765 35.6982 6.3217 10 80 19.9658 37.7111 17.7453 11A 48

.00u0 23.7862 23.7862 11B 28

.0000 21.0276 21.0276 TOTAL 193 14.1938 32.5963 18.4025