9
(
,f Amendment to the Annual Report on the Operations of the Washingten State University TRIGA Reactor Facility License R-76 for the reporting period of July 1,1983 to June 30, 1984.
Some of the personnel and environmental radiation exposure data was not available at the time the Annual Report was prepared. The complete radiation exposure sections are as follows:
Page 4, Section G, Table VI, Average Quarterly Reactor and Experimenter Staff Exposure.
May and June badge results were not included.
Below is the completed Table VI:
Table VI Average Quarterly Reactor / Experimenter Staff Exposures (in millirems)
Jul-Aug-Sep Oct-Nov-Dec Jan-Feb-Mar Apr-May-Jun 24 14 52 7
Page 5,Section I, Environmental Monitoring Program, Table VII Below is the completed Environmental Radiation Levels, Table VII Table VII Environmental Radiation Levels in the Vicinity of the WSU Nuclear Reactor
- Exposure in uR/ day J-A-S 0-N-D J-F-M A-M-J Median 143 248 193 80 166
- Sampling stations 50 meters or greater distance Mhl 8411010345 840630 PDR ADOCK 05000027 R
I pyg
Wf
. gd ;-
Page 6 Section I, Environmental Monitoring Program, Table VIII Table VIII Exposure Rates Adjacent to the WSU Reactor
- Exposure in uR/ day JAS OND JFM AMJ Median Building Entrance 167 237 222 9
157 E. Lower Loading Dock 67 250 210 200 182 E. Pool Rcom Door 5300 224 3551 67 2286 Storage Shed 1167 217 713 p
524 N. Side of Building 133 230 228 200 198 W. Beam Room Door 200 230 210 200 210 W. Side of Building 400 217 246 267 283
- Sampling stations less than 50 meters distance Page 6,Section I, ALARA Specifications in Technical Specifications in 3.12(2)
Calendar year 1983 ALARA limits for closest offsite extended occupancy vs. background radiation exposure ratio was given in the Annual Report.
Below is the fiscal year data for the reporting period of July 1,1983 to June 30, 1984.
For the reporting period, the average background radiation level for sampling points 400 meters or greater from the facility was 18/uR/ day.
The average radiation level at the closest extended occupied area 380 meters away was 214 uR/ day which yields a ratio of exposure to background of 18.2%.
ALARA limit is 20% exposure ratio.
i i
--m,-
r----
,--~r--
s
,a, n
m-
~
r--
m WASHINGTON STATE UNIVERSITY PbLLMAN,' WASHINGTON 99164 NUCLEAR RADIATION CEhTER -
October 25, 1984 Director, Division of Reactor Licensing U.S. Nuclear Regulatory Commission Washington, D.C.
20545 Re: Docket No. 50-27 Facility License R-76
Subject:
Amendments to 1983-1984 Annual Report
Dear Sir:
Please find enclosed an amendment to the 1983-1984 annual report for facility license R-76 that includes data that was not available at the time the report was submitted.
Sincerely, W-
-W.E. Wilson Associata Director 1
WEW:mt-Enc.
cc: John Sheppard, Chairman Reactor Safeguards Committee C.J. Nyman, Dean of the Graduate School l
N.R.C.-Region V, Office of l
Inspection and Enforcement J.A. ?!eidiger l
l f
'I I
i Y'
. -.