ML20106H696

From kanterella
Jump to navigation Jump to search
Submits Supplemental Response to IE Bulletin 84-02 Re Failure of GE Type Hfa Relays in Use in Class 1E Safety Sys. No Generic Problems w/safety-related Relays Found
ML20106H696
Person / Time
Site: Oconee  
Issue date: 09/12/1984
From: Tucker H
DUKE POWER CO.
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
IEB-84-02, IEB-84-2, NUDOCS 8410310717
Download: ML20106H696 (1)


Text

DUKE POWER GOMPANY P.O. BOX 33180 CHARLOTTE, N.O. 28242 HAL B. TUCKER TELEPHONE 84 SEP 18 Sehtiehgr

('a " "*"

12, 1984-

=m.

=>o.

Mr. James P. O'Reilly, Regional Administrator U. S. Nuclear Regulatory Commission Region II 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30323 Re: Oconee Nuclear Station Docket Nos. 50-269, -270, -287 IE Bulletin 84-02

Dear Sir:

This letter is a Supplemental response to IE Bulletin 84-02 which concerns-failures of GE type HFA relays in use in class IE Safety Systems. By a letter dated July 13, 1984,- Duke provided an initial response to. this Bulletin for0conee Nuclear Station.

In this letter you were informed that Duke's review addressing the generic concerns expressed in the Bulletin was still in progress and would be provided shortly after completion of the

'invehtigation. This letter provides the results of our investigation.

DukehasfoundthiattherearenosimilarproblemswithOconee'ssafety-related relays.

I declare under penalty of perjury that the information contained herein is correct to the best of my knowledge as executed on September 12, 1984.

Very truly yours, r-MA;2 /

Hal B. Tucker PFG:slb l

cc: Document Control Desk Ms. Helen Nicolaras U. S. Nuclear Regulatory Commission Office of Nuclear Reactor Regulation Washington, D. C.

20555 U. S. Nuclear Regulatory Commission Washingtori, 'D. '(i.~ 205'55'-

i NRC Resident Inspector Oconee Nuclear Station i

0$000ff, PDR

[ [//t 0