Text
VIROINIA ELECTRIC AND Powen COMPANY RIcirwoxo,VInoINIA 20261 W.L.SrnwAmr Vacs Pasernswr February 6, 1985 Nectaan orsmATIONS Mr. Harold R. Denton, Director Serial No.85-072 Office of Nuclear Reactor Rogu)ation N0/JHL:acm i
Attn:
Mr. James R. Miller, Chief Docket Nos. 50-338 Operating Reactors Branch No. 3 50-339 Division of Licensing License Nos. NPF-4 U. S. Nuclear Regulatory Commission NPF-7 Washington, D. C. 20555 Gentlemen:
VIRGINIA ELECTRIC AND POWER COMPANY NORTH ANNA POWER STATION UNIT NOS. 1 AND 2 REACTOR CONTAINMENT BUILDING INTEGRATED LEAK RATE TEST In accordance with 10CFR50, Appendix J.
Section V.B., the Virginia Electric and Power Company submits the Reactor Containment Building Integrated Leak Rate Test, Types A, B, and C, for North Anna Power Station Unit Nos. I and 2.
Very truly yours, d'V Y W. L. Stewart Enclosures cc:
Mr. James P. O'Reilly Regional Administrator Region II Mr. M. W. Branch NRC Resident Inspector North Anna Power Station-
[
}p R
i 4
.