b Consumers Power Company General offices: 1945 West Parnall Road. Jackson, MI 49201 + ($17) 788-0560 February 4, 1985 James G Keppler, Administrator Region III US Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, IL 60137 DOCKET 50-255 - LICENSE DPR PALISADES PLANT - SUBMITTAL OF ADDITIONAL ANALYSIS RESULTS AS REQUESTED BY IE INSPECTION REPORT 84-21 Consumers Power Company agreed to analyze a clean waste receiver tank sample for Tritium, Strontium 89 and 90 and gross beta and submit the results to the NRC for comparison with the NRC reference laboratory results. The plant's analysis determined the following values:

Tritium 3.9E-2 1 1.4E-3 uci/ml Strontium-89 560 i 31 pci/l (5.6E-7 uci/ml)

Strontium-90 100 1 9 pei/l (1.0E-7 uci/ml)

Gross Beta 1.5E-4 2 1.3E-5 uci/ml I

phi

~

risc Senior Licensing Analyst CC Director, Office of Inspection and Enforcement Director, Office of Nuclear Reactor Regulation NRC Resident Inspector - Palisades 985 LEEB 7 h

h 0

Ph i0 i

lElR-84-21A-NLO2 i

I-L