Final Deficiency Rept Re Internal Electrical Shorting of Barton 752 Transmitters.Initially Reported on 840424. ITT-Barton Incorporated Use of Lockwashers Into Design Which Will Eliminate Possibility of Shorting Condition
ML20106B625
Person / Time
Site: Wolf Creek Wolf Creek Nuclear Operating Corporation icon.png
Issue date: 10/08/1984
From: Koester G
KANSAS GAS & ELECTRIC CO.
To: Hunter D
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
KMLNRC-84-177, NUDOCS 8410230373
Download: ML20106B625 (1)


Text

_

KANSAS GAS AND ELECTRIC COMPANY THE EL.EC e'thC COMPANY CLENN L MOESTER WCE PatsacENT eeuctEAR October 8, 1984 Mr. D.R. Hunter, Chief jl Q@hh Reactor Project Branch 2 F

U.S. Nuclear Legulatory Commission k

Region IV 611 Ryan Plaza Drive, Suite 1000 1

OCT I ? 2 Arlington, Texas 76011 I

KMLNRC 84-177 Re:

Docket No. STN 50-482 Ref: Interim Report KMLNRC 84-078 dated 5/23/84 from GLKoester, KG&E, to EHJohnson, NRC Subj: Final 10CFR50.55(e) Report - Barton 752 Transmitters

Dear Mr. Hunter:

This letter provides the final report submitted pursuant to 10CFR50.55(e) concerning internal electrical shorting of Barton 752 Transmitters at Wolf Creek Generating Station (WCGS). This matter was initially reported on April 24, 1984 and supplemental information was provided in the Reference.

The Reference stated that three ITT - Barton 752 Transmitters were found to be short circuiting internally. An examination of the affected transmitters by ITT - Barton determined that the shorting condition was caused by a " stacking" of tolerances among the carrier plates, a circuit board trace on one of the plates, and the hold down lockwashers. As a result of the above examination ITT - Barton has incorporated into the design, the use of lockwashers which have a smaller outside diameter.

This action will eliminate the possibility of the shorting condition. In addition, it has been determined that the shorting condition is immediately detectable upon connection of the transmitter to the system loop wiring.

Therefore, if no shorting condition existed at the time of installation, it is impossible for a short to occur later since the carrier plate is torqued in place and no movement of the lockwashrs is possible.

The aforementioned corrective action has been completed. If you have any questions concerning this matter, please contact me or Mr. Otto Maynard of my staff.

8410230373 841008 Y urs very truly, PDR ADOCK 05000482 S

PDR 1

GLK bb N

g xc:RCDeYoung

,,[

$)

PO'Connor 6RBundy 0