.. _... _ _..

GEL:icar Energy re,,w a m cw m July 6,1992 v3 cuo y,A wyg s n A n c4 m a MFN No.14192 Docket No. STN 52 001 SLK 9282 Document Control Desk U.S. Nuclear Regulatory Commissic n Washington, D.C. 20555 Attention:

Robert C. Pierson, Director Standardization and Non Power Reactm Project Directorate

Subject:

Submittal of Ar.nendment 21 to GE's ABWR SSAR

Reference:

Submittal of Amendment 21, Proprietary Information. to GE's ABWR SSAR, MFN No.142 92 Enclosed are thirty four (34) copies of seleaed sections of Chapte.1, Introduction and General

^

Description of Plant, Chapter 2, Site Characteristics, Chapter 3, Design of Structures, Components, Equipment, and Systems, Chapter 4, Reactor, Chapter 5, Reactor Coolant System am: Connected Systems, Chapter 6, Engineered Safety Features, Chapter 7, Imtmmentation and Contml Systems,

[

Chapter 8, Electric Pow:r, Chapter 9,.luxiliary Systems, Chapter 10, Steam and Power Coversion System, Chapter 11, Radioactive Waste Management, Chapter 12, Radiation Pmtection, Chapter 14, Initial Test Program, Chapter 15, Accident Analysis, Chapter 17, Quality Assurance, Chapter 18, Human Factors Engincedag, Chapter 19, Response to Severe Accident Policy Statement, Chapter 20, i

Question and Response Guide, of the Standard Safety Analysis Report (SSAR) for the Advanced Boiling Water Reactor (ABWR).

F Changes to the various sections of the SSAR are identified on the attached Page Change Instructions. Pace Change Instructions for the 11 x 17 inch drawings will be included with the drawings which are to be forwarded in the near future under separate cover.

Plaase note that all or parts of the following sections contain infarmation that is designated as General Electric Company proprietary information: 1.2, 31, 9.3, ').4, 9.5, 9A.4, 9A.5,11.2,12.3, 18F,198,19D,19E,19F,19FA, and 20.3. This information is being submitted under separate cover.

Sincerely, _

U S.J. Stark, Acting Manager Regulatory and Analysis See b es cc:

R. C. Berglund (GE)

T. E. Murley (NRC)

D. M. Crutchfield (NRC)

D. J. McGoff

'(DOE)

F.J. Miraglia Jr.

(NRC)

C. Poslusny, Jr.

(~.4RC) g[0f0 K. E. Stahlkopf (EPRI) e F. A. Ross (DOE) g h.

N. D, Fleacher, n (DOE) iUUu41 E

1