TU ELECTRIC COMANCHE PEAK STEAM ELECTRIC STATION 1995 FIELD EXERCISE NARRATIVE

SUMMARY

O l

i l

I' 9604040115 951018 PDR ADOCK 05000445 F

pan

PLANT CONDITIONS I

Unit 1 is at 100 percent power in its fifth fuel cycle.

Unit 2 is at 100 percent power in its second fuel cycle.

All plant parameters are normal and stable.

The last shift relieved the pressure in Unit 1 Containment Building that had built up over the last week. Upon completion of the pressure relief, valve 1HV-5549 (inside react or containment isolation) failed to fully close. Valve 1HV-5548 (outside reactor containment isolation) has been verified shut to satisfy Tech Specs.

The exercise is scheduled to begin at 7:00 a.m., Wednesday, December 06, 1995.

l METEOROLOGICAL CONDITIONS Temperature is 45 degrees F with wind out of the Southwest at 5 mph.

Temperature will increase to about 50 degrees by midday.

Wind speed will increase to about 10 mph over the same time l

period.

Weather will be fair with no major changes.

i j

NARRATIVE

SUMMARY

0645 Turnover briefing for the simulator crew.

,j 0700 Start the simulator.

i 0715 25 gpm leak from the U1 RCS. Location unknown.

0730

, Notification of Unusual Event (NOUE) declared due to RCS leakage. (EPP-201; Chart 2i 2A, 2B NOUE) 0800 Fire in Train A Diesel Generator. (Results in loss of operability of Trn A DG) 0815 Alert declared from the Control Room due to fire l

effecting safety related equipment.

Emergency response facilities should bervin staffing at this time.

l (EPP-201; Chart 10; 10H, 10E Alert) 0900 RCS leakage increases to greater than the capacity of the CCPs following SI actuation.

0905 Valve 1-HV-5548, and ventilation damper 1-HV-5574, fail partially open creating a minor radiological release.

0915 Site Area Emergency declared from the Technical Support r

Center (TSC) or Emergency Operations Facility (EOF) due 4

i to RCS leakage.

(

A Site Evacuation will be called due to the SAE.

(EPP-201; Chart 2; 2A, 2B, 2C, 2D, 2G Site Area Emergency)

TU-95-FE 1

Rev. 5 l

1 l

RHR pump 1-02 wil'1 seize due to 0925

<st..re.r. aire.

trei debris. Foreign material will prevent fully closing sump suction valve 8811B.

0930 1EA1 bus fault results in loss of Trn A ECCS.

0945 RWST fault.

1000 Indications (CET/RVLIS/HRRM) show that the core is uncovered and is overheating. Radiological release through containment ventilation valve 1-HV-5548 is still in progress.

i 1015 General Emergency is declared.

(EPP-201: Chart 2; 2A, 2B, 2C, 2D, 2E General Emergency)

(PAR: Evacuate 2A and effected sectors to 5 miles based on plant conditions or dose projections.)

1230 Shift relief for key offsite players.

1245 Contaminated injury to an ERDC team member in the RCA.

1300 Wind slowly shifts to coming from 250 degrees.

1400 Bus 1EA1 repaired and available to be returned to service.

1500 Exercise terminated.

TU-95-FE 2

Rev. 5

_..,_._-.-..a.

, ~.

.. ~..

4 1

e e

e TU ELECTRIC COMANCHE PEAK STEAM ELECTRIC STATION 1995 FIELD EXERCISE TIMELINE t'

k I

J

1995 FIELD EXERCISE TIMELINE (Note: All events refer to Unit 1)

MESSAGE TIME NUMBER

SUMMARY

0645 1

INITIAL CONDITIONS ESTABLISHED FOR THE SIMULATOR CREW.

0700 NONE START THE SCENARIO.

0715 NONE 25 GPM REACTOR COOLANT SYSTEM (RCS) LEAK, LOCATION UNKNOWN.

0730 NONE NOTIFICATION OF UNUSUAL EVENT DECLARED DUE TO 1

RCS LEAKAGE.

0740 2

CONTINGENCY MESSAGE PLANT CONDITIONS WARRANT DECLARATION OF A NOTIFICATION OF UNUSUAL EVENT,

]

0800 NONE FIRE BEGINS IN TRAIN A EMERGENCY DIESEL GENERATOR. DIESEL BECOMES INOPERABLE.

0815

-NONE ALERT DECLARED DUE A FIRE GREATER THAN 15 MINUTES AFFECTING A SAFETY SYSTEM.

0825 3

CONTINGENCY MESSAGE PLANT CONDITIONS WARRANT DECLARATION OF AN ALERT.

d825 4

FIRE DECLARED OUT.

0845 5

CONTINGENCY MESSAGE EMERGENCY COORDINATOR IS DIRECTED TO RELOCATE TO THE TSC.

i l

0900 NONE LARGE BREAK LOSS OF COOLING ACCIDENT (LOCA)

OCCURS, RESULTING IN A REACTOR TRIP AND SAFETY INJECTION.

3 TU-95-FE Rev.I

~

4 0905 NONE AS CONTAINMENT PRESSURE INCREASES, CONTAINMENT PRESSURE RELIEF VALVE 1-HV-5548 AND VENTILATION DAMPER 1-HV-5574 FAIL PARTIALLY OPEN. THIS LEADS TO A MINOR RADIOACTIVE RELEASE.

6 0915 NONE SITE AREA EMERGENCY DECLARED DUE TO RCS LEAKAGE.

0925 6

CONTINGENCY MESSAGE PLANT CONDITIONS WARRANT DECLARATION OF. A SITE AREA EMERGENCY.

0925 NONE RHR PUMP 1-02 SEIZES DUE TO DEBRIS. FOREIGN MATERIAL STOPS FULL CLOSURE OF SUMP SUCTION VALVE 8811B.

0930 NONE 1EA1 BUS FAULT RESULTS IN LOSS OF TRAIN A ECCS.

0945 NONE RWST LOST AS SOURCE OF WATER FOR RCS.

1000 NONE INDICATIONS SHOW THE CORE IS UNCOVERED AND OVERHEATING. RADIOACTIVE RELEASE CONTINUES.

1015 NONE GENERAL EMERGENCY DECLARED DUE TO RCS LEAK, LOSS OF CORE COOLING AND LOSS OF CONTAINMENT.

1025 7~

PLANT CONDITIONS WARRANT DECLARATION OF A CONTINGENCY MESSAGE GENERAL EMERGENCY.

1230 8

SHIFT RELIEF BEGINS FOR KEY OFFSITE PLAYERS.

1245 9

ERDC TEAM MEMBER CONTAMINATED AND INRJRED.

1300 NONE WIND SHIFT TO 240 DEGREES REQUIRES NEW 1

PROTECTIVE ACTION RECOMMENDATION (PAR).

1330 10 CONTINGENCY MESSAGE CONDITIONS REQUIRE AN UPDATED PAR.

1400 11 BUS 1EA1 RETURNED TO SERVICE. RHR PUMP MAY BE STARTED, RESTORING CORE COOLING.

[

1500 11 THE EXERCISE IS TERMINATED AT THE DIRECTION OF THE LEAD CONTROLLER.

TU-95-FE Rev.1

_A J_a-_am*3,w.Ma da.an__he Aama.. _.m _ oh and S,%4mAace4+s&.--.i,aca s, -* Amm h, as-wua a*.ma4-W a*.mJ.-.wa..Mda-ma.-<w3

.eu-,.

s=~e-#2m

-+,.a--a__ea.a s#.ma.ise.u

<-.m u4,.-

_ma-_.m4wm.

e a

J 4

4

)

4 TU ELECTIUC COMANCHE PEAK STEAM ELECTRIC STATION 1995 FIELD EXERCISE

. GRAPHS e

9 4

e S

w.a.~.imee*wwwe-4 i

Reator Power M

A O

O O

N O

O O

O O

O O

O N.

O O

O

.O 1

j C

l O

(D.

a O

u o

a l

a

.O.

O O

-l M

h 8

aC g

oz

o -

b

]d I

a i

M..

1 O

D 0

l i

c,3 4

i O

o i

I 1

l d

)

I b.

O 1

O J

d i

l U

O a

O.

.O O

4

1 2

3 4

5 6

7 0

0 0

0 0

0 0

0

~.. ;...

o~ 8 N

o~8 m

88 o=8 m

ou8 88 o8 a8 PR E

e=8 S

SU T

URN l

M

,=8 I

ZIET E

RL 1 en8 EV EL u8

,u8

,u8 u8 u8

.u8 u8 u8

psig o

o o

o 07:00 07:30 08:00 4

08:30 09:00 -

h m.

09:30 -

10:00 10:30 oO 11:00 se d

mZ E

11:30 d

mxa 12:00 c2 12:30 m

13:00 13:30

[:

j 14:00

/

14:30 /

15:00 - f

[

15:30 16:00 I

.4 w

w r

m a

n a

e o

o o

o o

o o

o o

o o

o 07:00 07:30 08:00 08:30 09:00 -

pnums

======="

p g

09:30 - ---

10:00 10:30 11:00 DEC y

$Z E

11:30 rH T

m mL 12:00

"'r 12:30 13:00 i3:30 14:00 14:30 15:00 15:30 16:00

Degrees F 1

1

?

?

?

m m

h i

i 1

07:00

l a

07:30 l

4 08:00 i

08:30 i

w f

09:00 f

i 09:30 10:00 3

10:30 1

5 11:00

~

d Ez E

11:30 8 -'"

q m

To mL 12:00 QA 12:30 13:00 13:30 14:00 14:30 f'

p 15:00 15:30 16:00

-~

I

Rem /hr E,

k k

5 I

a g

9 a

07:00 07:30 l ll 08:30 A

09:30

'4 (

10:00 10:30 11:2

{k 3Z C

sg 11:30 e

m

,a, 12:00 iu i

,, ee ly I l\\l 1.

o l lt ly jjj l yjl t

j ll 1 ii F

I

.l uct/sec

?

?

?

o o

e o

e m

m m

m m

4 o

6 o

N o

o m

07:00

)

\\

l 07:30 4

08:00 i

08:30 I.

09:00 i

09:30 10:00

'* Inn, 4

10:30 11:00

$(n C H

RZ l

J E

11:30 I-H m

8a E

12:00 1

i 12:30 l

l 13:00 13:30 i

4 14:00 14:30 4

15:00 15:30 16:00

.i

.i I

  1. W-"m-44ew,,w.,,,

h I

e P

1 TU ELECTRIC COMANCHE PEAK STEAM ELECTRIC STATION 1995 FIELD EXERCISE METEOR.OLOGICAL CONDITIONS l

I i

t

\\

l t

?

METEOROLOGY INPUT DATA Real Time Wind Speed Wind Dir.

Delta-t Air Temp.

Amb. Press 07:00 5

225

-0.5 45 14.7 07:15 5

225

-0.5 45 14.7 07:30 5

225

-0.5 45 14.7 07:45 5

225

-0.6 46.

14.7 08:00 5

225

-0.6 46 14.7 08:15 5

225

-0.6 47 14.7 08:30 5

225

-0.6 47 14.7 08:45 6

225

-0.6 47 14.7 09:00 6

227

-0.7 48 14.7 09:15 6

227

-0.7 48 14.7 09:30 6

227

-0.7 48 14.7 09:45 6

230

-0.7 49 14.7 10:00 7

230

-0.8 49 14.7 10:15 7

230

-0.8 49 14.7 10:30 7

230

-0.8 49 14.7 10:45 7

233

-0.8 49 14.7 11:00 7

233

-0.9 48 14.7-11:15 8

233

-0.9 48 14.7 i

11:30 8

233

-0.9 50 14.7 11:45 8

235

-0.9 50 14.7 12:00 8

235

-0.9 50 14.7 12:15 8

235

-1 50 14.7 12:30 9

235

-1 50 14.7 12:45 9

234

-1 50 14.7 13:00 9

240

-1 50 14.7 13:15 9

240

-1.1 50 14.7

~13:30 10 240

-1.1 50 14.7 13:45 10 250

-1.1 50 14.7 14:00 10 250

-1.1 51 14.7 14:15 10 250

-1.1 51 14.7 14:30 11 250

-1.2 51 14.7 14:45 11 250

-1.2 51 14.7 15:00 11 250

-1.2 51 14.7 Wind Speed Units:

Miles / hour Wind Direction Units:

Degrees Delta-t Units:

Deg. F/50 m Air Temperature Units:

Fahrenheit Ambient Pressure Units:

Psia

a-,-

1~..

a

..=..

..~a-

+

l e

l TU ELECTRIC COMANCHE PEAK STEAM EECTRIC STATION 1995 FIELD EXERCISE OFFSITE SURVEY DATA B

4 6

State of Tcxas

,1995 Graded Exercise 06-December-1995 REAL TIME:

07:00 RELATIVE TIME:

H+00:00

      • o****************************************************************************

OFFSITE RADIOLOGICAL SURVEY DATA oece****************************************************************************


METEOROLOGICAL DATA---------- ------------RELEASE DATA---------------

WIND SPEED (MPH) 5.00 NOBLE GAS (CI/SEC) 0.000E+00 DELTA-T (DEG. F/50M)

-0.50 IODINE (CI/SEC) 0.000E+00 STABILITY CLASS (PASQUILL)

D PARTICULATE (CI/SEC) 0.000E+00 WIND DIRECTION (DEGREES) 225.0 TOTAL (CI/SEC) 0.000E+00 PLUME TRAVEL (MI) 0.000E+00 AVERAGE GAMMA (MEV/ DIS)

O.00 PLUME TRAILING EDGE (MI) 0.000E+00 AVERAGE BETA (MEV/ DIS) 0.00 1995 Graded Exercise l

'StEta of Texas

,1995 Graded Exercise 06-December-1995 1t REAL TIME:

07:15 RELATIVE TIME:

H+00:15 i ooooo***************************************************************************

OFFSITE RADIOLOGICAL SURVEY DATA

    • ooe***************************************************************************

l


METEOROLOGICAL DATA---------- ------------RELEASE DATA---------------

WIND SPEED (MPH) 5.00 NOBLE GAS (CI/SEC) 0.000E+00 DELTA-T (DEG. F/50M)

-0.50 IODINE (CI/SEC) 0.000E+00 STABILITY CLASS (PASQUILL)

D PARTICULATE (CI/SEC) 0.000E+00 l

WIND DIRECTION (DEGREES) 225.0 TOTAL (CI/SEC) 0.000E+00 I

PLUME TRAVEL (MI) 0.000E+00 AVERAGE GAMMA (MEV/ DIS) 0.00 l

PLUME TRAILING EDGE (MI) 0.000E+00 AVERAGE BETA (MEV/ DIS) 0.00 1995 Graded Exercise l

9 4

I i

l l

a

1 StCto of T m 3

.1995 Graded Exercise 06-December-1995 REAL TIME:

07:30 RELATIVE TIME:

H+00:30 oooo****************************************************************************

OFFSITE RADIOLOGICAL SURVEY DATA oeoo****************************************************************************

I


METEOROLOGICAL DATA----------


RELEASE DATA---------------

WIND SPEED (MPH) 5.00 NOBLE GAS (CI/SEC) 0.000E+00 DELTA-T (DEG. F/50M)

-0.50 IODINE (CI/SEC) 0.000E+00 UTABILITY CLASS (PASQUILL)

D PARTICULATE (CI/SEC) 0.000E+00 WIND DIRECTION (DEGREES) 225.0 TOTAL (CI/SEC)

~

0.000E+00 PLUME TRAVEL.(MI) 0.000E+00 AVERAGE GAMMA (MEV/ DIS) 0.00 PLUME TRAILING EDGE (MI) 0.000E+00 AVERAGE BETA (MEV/ DIS) 0.00 1995 Graded Exercise

>l

4 StOto of Texas 1995 Graded Exercise 06-December-1995 REAL TIME:

07:45 RELATIVE TIME:

H+00:45

    • oo****************************************************************************

OFFSITE RADIOLOGICAL SURVEY DATA

    • eo****************************************************************************

METEOROLOGICAL DATA---------- ------------RELEASE DATA---------------

WIND SPEED (MPH) 5.00 NOBLE GAS (CI/SEC) 0.000E+00 DELTA-T (DEG. F/50M)

-0.60 IODINE (CI/SEC) 0.000E+00 STABILITY CLASS (PASQUILL)

D PARTICULATE (CI/SEC) 0.000E+00 WIND DIRECTION (DEGREES) 225.0 TOTAL (CI/SEC) 0.000E+00 PLUME TRAVEL (MI) 0.000E+00 AVERAGE GAMMA (MEV/ DIS) 0.00 PLUME TRAILING EDGE (MI) 0.000E+00 AVERAGE BETA (MEV/ DIS) 0.00 1995 Graded Exercise I

i i

1 e

State of Tcxes 1

1

,1995 Graded Exercise 06-December-1995 REAL TIME:

08:00 RELATIVE TIME:

H+01:00 oo******************************************************************************

OFFSITE RADIOLOGICAL SURVEY DATA


METEOROLOGICAL DATA----------


RELEASE DATA---------------

WIND SPEED (MPH) 5.00 NOBLE GAS (CI/SEC) 0.000E+00 DELTA-T (DEG. F/50M)

-0.60 IODINE (CI/SEC) 0.000E+00 STABILITY CLASS (PASQUILL)

D PARTICULATE (CI/SEC) 0.000E+00 WIND DIRECTION (DEGREES) 225.0 TOTAL (CI/SEC) 0.000E+00 PLUME TRAVEL (MI) 0.000E+00 AVERAGE GAMMA (MEV/ DIS) 0.00 i

PLUME TRAILING EDGE (MI) 0.000E+00 AVERAGE BETA (MEV/ DIS) 0.00 1F95 Graded Exercise i

l l

l l

i I

State of Texas 1995 Graded Exercise 06-December-1995 REAL TIME:

08:15 RELATIVE TIME:

H+01:15 eeeee***************************************************************************

OFFSITE RADIOLOGICAL SURVEY DATA eeee****************************************************************************


METEOROLOGICAL DATA----------


RELEASE DATA---------------

WIND SPEED (MPH) 5.00 NOBLE GAS (CI/SEC) 0.000E+00 DELTA-T (DEG. F/50M)

-0.60 IODINE (CI/SEC) 0.000E+00 STABILITY CLASS (PASQUILL)

D PARTICULATE (CI/SEC) 0.000E+00 WIND DIRECTION (DEGREES) 225.0 TOTAL (CI/SEC) 0.000E+00 PLUME TRAVEL (MI) 0.000E+00 AVERAGE GAMMA (MEV/ DIS) 0.00 PLUME TRAILING EDGE (MI) 0.000E+00 AVERAGE BETA (MEV/ DIS) 0.00 1995 Graded Exercise i

G

~

State of Tcxa2 1995 Graded Exercise 06-December-1995 REAL TIME:

08:30 RELATIVE T H+01:30 coo*********************************************************IME:

OFFSITE RADIOLOGICAL SURVEY DATA


METEOROLOGICAL DATA---------- ------------RELEASE DATA---------------

WIND SPEED (MPH) 5.00 NOBLE GAS (CI/SEC) 0.000E+00 DELTA-T (DEG. F/50M)

-0.60 IODINE (CI/SEC) 0.000E+00 STABILITY CLASS (PASQUILL)

D PARTICULATE (CI/SEC) 0.000E+00 WIND DIRECTION (DEGREES) 225.0 TOTAL (CI/SEC) 0.000E+00 PLUME TRAVEL (MI) 0.000E+00 AVERAGE GAMMA (MEV/ DIS) 0.00 lPLUMETRAILINGEDGE (MI) 0.000E+00 AVERAGE BETA (MEV/ DIS) 0.00 1995 Graded Exercise i

l l

'1{'

1

i Stcto of Taxso I,1995 Graded Exercise 06-December-1995 t

REAL TIME:

08:45 RELATIVE TIME:

H+01:45 l

eeooe***************************************************************************

OFFSITE RADIOLOGICAL SURVEY DATA

    • eoo***************************************************************************

METEOROLOGICAL DATA---------- ------------RELEASE DATA--------------.

WIND SPEED (MPH) 6.00 NOBLE GAS (CI/SEC) 0.000E+00 DELTA-T (DEG. F/50M)

-0.60 IODINE (CI/SEC) 0.000E+00 STABILITY CLASS (PASQUILL)

D PARTICULATE (CI/SEC) 0.000E+00 WIND DIRECTION (DEGREES) 225.0 TOTAL (CI/SEC) 0.000E+00 PLUME TRAVEL (MI) 0.000E+00 AVERAGE GAMMA (MEV/ DIS) 0.00 PLUME TRAILING EDGE (MI) 0.000E+00 AVERAGE BETA (MEV/ DIS) 0.00 1995 Graded Exercise l

d a

S f

l 1

Stcto of Tcxas 1995 Graded Exercise 06-December-1995 REAL TIME:

09:00 RELATIVE TIME:

H+02:00

  • oce****************************************************************************

OFFSITE RADIOLOGICAL SURVEY DATA eeoo****************************************************************************


METEOROLOGICAL DATA----------


RELEASE DATA---------------

WIND SPEED (MPH) 6.00 NOBLE GAS (CI/SEC) 0.000E+00 DELTA-T (DEG. F/50M)

-0.70 IODINE (CI/SEC) 0.000E+00 STABILITY CLASS (PASQUILL)

D PARTICULATE (CI/SEC) 0.000E+00 WIND DIRECTION (DEGREES) 227.0 TOTAL (CI/SEC) 0.000E+00 PLUME TRAVEL (MI) 0.000E+00 AVERAGE GAMMA (MEV/ DIS) 0.00 PLUME TRAILING EDGE (MI) 0.000E+00 AVERAGE BETA (MEV/ DIS) 0.00 1995 Graded Exercise l

l l

l l

l 1

i l

I

l State of Tcxas 1995 Graded Exercise 06-December-1995 REAL TIME:

09:15 RELATIVE TIME:

H+02:15 eeeee***************************************************************************

OFFSITE RADIOLOGICAL SURVEY DATA ee*ee***************************************************************************

l


METEOROLOGICAL DATA----------


RELEASE DATA---------------

WIND SPEED (MPH) 6.00 NOBLE GAS (CI/SEC) 4.084E-02 DELTA-T (DEG. F/50M)

-0.70 IODINE (CI/SEC) 2.600E-04 STABILITY CLASS (PASQUILL)

D PARTICULATE (CI/SEC) 5.543E-03 WIND DIRECTION (DEGREES) 227.0 TOTAL (CI/SEC) 4.665E-02 PLUME TRAVEL (MI) 1.503E+00 AVERAGE GAMMA (MEV/ DIS) 0.88 PLUME TRAILING EDGE (MI) 0.000E+00 AVERAGE BETA (MEV/ DIS)

O.37 1995 Graded Exercise i

l l

LOCATION l

DOSE RATE l

AIR CONCENTRATION l AIR SAMPLE CPM l GROU W DEPOSITION l BACKGROUN DOWN DIST.

CLOSED OPEN GROSS GROSS NOSLE IG)!NE GROSS GROSS GROSS NET SACKGROUR WIND OFF WINDOW WINDOW ISINE PART.

GAS 131

!CDINE PART.

DEPOSIT.

GROUND COUNT DIST CENT.

DOSE R.

DOSE R.

ACTIVITY ACTIVITY ACTIVITY ACTIVITY COUNT R.

COUNT R.

COUNT R.

DEPOSIT.

RATE (MI) (MI)

(MR/NR)

(MR/NR) (UCI/CC).(UCI/CC)

(UCI/CC) (UCI/CC)

(CPN)

(CPM)

(CPM)

(UCI/M2)

(CPM) 1 0.5 0.00 1.26 2.09 8.50E 09 1.81E 07 1.39E-06 9.68E-10 4.47E+02 1.03E+04 5.89E+02 1.71E+00 20 l

0.04 0.77 1.27 5.15E-09 1.10E 07 8.41E 07 5.8'tE 10 2.79E+02 6.24E+03 3.65E+02 1.04E+00 20 O.08 0.17 0.28 1.15E 09 2.45E 08 1.88E 07 1.31E 10 7.78E+01 1.41E+03 9.70E+01 2.31E 01 20 0.12 0.01 0.02 9.44E 11 2.01E-09 1.54E 08 1.08E 11 2.47E+01 1.34E+02 2.63E+01 1.90E 02 20 1.0 0.00 0.57 0.94 3.73E-09 7.95E 08 6.27E 07 4.25E-10 2.07E+02 4.52E+03 2.69E+02 7.49E 01 20 0.07 0.35 0.57 2.26E-09 4.82E 08 3.80E-07 2.58E 10 1.34E+02 2.75E+03 1.71E+02 4.54E-01 20 0.15 0.08 0.13' 5.04E 10 1.08E 08 8.49E 08 5.75E 11 4.54E+01 6.29E+02 5.38E+01 1.01E 01 20 0.22 0.01 0.01 4.14E 11 8.83E 10 6.97E 09 4.72E 12 2.21E+01 7.00E+01 2.28E+01 8.32E 03 20 1.5 0.00 0.33 0.55 2.19E 09 4.671i-08 3.68E 07 2.49E 10 1.30E+02 2.66E+03 1.66E+02 4.40E-01 20 0.11 0.20 0.34.1.33E 09 2.83E 06 2.23E 07 1.51E 10 8.67E+01 1.62E+03 1.09E+02 2.67E-01 20 0.22 0.05 0.07 2.96E 10 6.31E 09 4.98E*08 3.37E 11 3.49E+01 3.77E+02 3.98E+01 5.95E-02 20 0.32 0.00 0.01 2.43E 11 5.18E 10 4.09E 09 2.77E 12 2.12E+01 4.93E+01 2.16E+01 4.88E 03 20 1995 Graded Exercise l

d I

i l

l

r Stcto of Tcxca

,1995 Graded Exercise 06-December-1995 l

REAL TIME:

09:30 RELATIVE TIME:

H+02:30 l

oocoo***************************************************************************

l OFFSITE RADIOLOGICAL SURVEY DATA l

eeoeo***************************************************************************


METEOROLOGICAL DATA---------- ------------RELEASE DATA---------------

WIND SPEED (MPH) 6.00 NOBLE GAS (CI/SEC) 1.379E-01 DELTA-T (DEG. F/50M)

-0.70 IODINE (CI/SEC) 6.452E-04 STABILITY CLASS (PASQUILL)

D PARTICULATE (CI/SEC) 1.528E-02 l

WIND DIRECTION (DEGREES) 227.0 TOTAL (CI/SEC) 1.538E-01 PLUME TRAVEL (MI) 3.006E+00 AVERAGE GAMMA (MEV/ DIS) 0.79 PLUME TRAILING EDGE (MI) 0.000E+00 AVERAGE BETA (MEV/ DIS) 0.37 1995 Graded Exercise LOCATION l

DOSE RATE l

AIR CONCENTRATION l AIR SAMPLE CPM l GROUND DEPOSITION l BACKGROUN DOWN DIST.

CLOSED OPEN GROSS GROSS NOBLE 10 DINE GROSS GROSS GROSS NET BACKGROUN WINO OFF WINDOW WINDOW IODINE PART.

GAS 131 IODINE PART.

DEPOSIT.

GROUND COUNT DIST CENT.

DOSE R.

DOSE R.

ACTIVITY ACTIVITY ACTIVITY ACTIVITY COUNT R.

COUNT R.

COUNT R.

DEPOSIT.

RATE (MI)

(MI)

(MR/HR) (MR/HR) (UCI/CC)

(UCI/CC)

(UCl/CC) (UCI/CC)

(CPM)

(CPM)

(CPM)

(UCI/M2)

(CPM) 0.5 0.00 3.39 5.87 2.11E-08 5.00E-07 4.68E 06 2.56E-09 1.08E+03 2.83E+04 1.99E+03 5.91E+00 20 0.04 2.06 3.56 1.28E-08 3.03E-07 2.84E 06 1.56E-09 6.63E+02 1.72E+04 1.21E+03 3.58E+00 20 0.08 0.46 0.79 2.85E-09 6.77E 08 6.34E-07 3.47E-10 1.64E+02 3.85E+03 2.86E+02 8.00E 01 20 0.12 0.04 0.07 2.34E-10 5.55E 09 5.20E 08 2.85E 11 3.18E+01 3.34E+02 4.19E+01 6.56E-02 20 1.0 0.00 1.53 2.65 9.25E-09 2.19E 07 2.12E 06 1.12E-09 4.85E+02 1.24E+04 8.83E+02 2.59E+00 20 0.07 0.93 1.60 5.61E 09 1.33E-07 1.28E-06 6.82E-10 3.02E+02 7.54E+03 5.43E+02 1.57E+00 20 0.15 0.21 0.36 1.25E-09 2.97E-08 2.87E-07 1.52E-10 8.29E+01 1.70E+03 1.37E+02 3.51E 01 20 0.22 0.02 0.03 1.03E-10 2.44E 09 2.35E 08 1.25E-11 2.52E+01 1.58E+02 2.96E+01 2.88E 02 20 1.5 0.00 0.90 1.55 5.43E 09 1.29E 07 1.24E-06 6.60E-10 2.93E+02 7.30E+03 5.26E+02 1.52E+00 20 0.11 0.54 0.94 3.29E-09 7.80E 08 7.54E 07 4.00E 10 1.86E+02 4.44E+03 3.27E+02 9.22E-01 20 0.22 0.12 0.21 7.34E 10 1.74E-08 1.68E-07 8.93E-11 5.69E+J1 1.01E+03 8.85E+01 2.06E 01 20 0.32 0.01 0.02 6.03E 11 1.43E 09 1.38E-08 7.33E-12 2.30E+01 1.01E+02 2.56E+01 1.69E-02 20 2.0 0.00 0.22 0.37 1.39E-09 2.97E 08 2.49E 07 1.58E 10 8.99E+01 1.70E+03 1.13E+02 2.80E 01 20 0.14 0.14 0.23 8.43E-10 1.80E-08 1.51E-07 9.61E-11 6.24E+01 1.04E+03 7.65E+01 1.70E-01 20 0.28 0.03 0.05 1.88E-10 4.02E 09 3.37E-08 2.14E-11 2.95E+01 2.47E+02 3.26E+01 3.79E-02 20 0.42 0.00 0.00 1.54E-11 3.30E-10 2.77E-09 1.76E 12 2.08E+01 3.87E+01 2.10E+01 3.11E-03 20 3.0 0.00 0.13 0.22 8.18E 10 1.75E 08 1.44E-07 9.33E 11 6.12E+01 1.01E+03 7.48E+01 1.65E-01 20 0.20 0.08 0.13 4.96E 10 1.06E-08 8.75E 08 5.66E-11 4.50E+01 6.20E+02 5.33E+01 9.99E-02 20 0.39 0.02 0.03 1.11E 10 2.37E 09 1.95E 08 1.26E 11 2.56E+01 1.54E+02 2.74E+01 2.23E 02 20 0.59 0.00 0.00 9.09E 12 1.94E 10 1.60E-09 1.04E 12 2.05E+01 3.10E+01 2.06E+01 1.83E 03 20 l

l i

1995 Graded Exercise l

T State of Tcxas 1995 Graded Exercise 06-December-1995 REAL TIME:

09:45 RELATIVE TIME:

H+02:45 OFFSITE RADIOLOGICAL SURVEY DATA f

l


METEOROLOGICAL DATA----------


RELEASE DATA---------------

WIND SPEED (MPH).

6.00 NOBLE GAS (CI/SEC) 7.470E-01 DELTA-T (DEG. F/50M)

-0.70 IODINE (CI/SEC) 2.804E STABILITY CLASS (PASQUILL)

D PARTICULATE (CI/SEC).

5.100E-02 i

WIND DIRECTION (DEGREES) 230.0 TOTAL (CI/SEC) 8.008E-01 l

PLUME TRAVEL (MI) 4.509E+00 AVERAGE GAMMA (MEV/ DIS) 0.69 l

PLUME TRAILING EDGE (MI) 0.000E+00 AVERAGE BETA (MEV/ DIS) 0.34 l

1995 Graded Exercise l

1 LOCATION l

DOSE RATE l

AIR CONCENTRATION l AIR SAMPLE CPM l GROUIC DEPOSITION l 8ACKGROUN l

DOWN DIST.

CLOSED OPEN GROSS GROSS NOBLE I(BINE GROSS GROSS GROSS NET BACKGROUN f

l WIND OFF WINDOW WINDOW 10 DINE PART.

GAS 131 10 DINE PART.

DEPOSIT.

GROUND COUNT i

DIST CENT.

DOSE R.

DOSE R.

ACTIVITY ACTIVITY ACTIVITY ACTIVITY COUNT R.

COUNT R.

COUNT R.

DEPOSIT.

RATE (MI) (MI)

(int /NR)

(NR/NR) (UCI/CC) (UCI/CC) (UCI/CC)

(UC!/CC)

(CPN)

(CPN)

(CPN)

(UCI/M2)

(CPM) 0.5 0.00 14.72 26.71 9.16E 08 1.67E-06 2.54E-05 1.18E-08 4.63E+03 9.44E+04 6.68E+03 2.00E+01 20 l

0.04 8.93

?6.20 5.56E 08 1.01E 06 1.54E 05 7.17E 09 2.82E+03 5.73E+04 4.06E+03 1.21E+01 20

.e 0.08 1.99 3.61 1.24E 08 2.26E-07 3.43E 06 1.60E-09 6.44E+02 1.28E+04 9.21E+02 2.71E+00 20 i

0.12 0.16 0.30 1.02E 09 1.85E 08 2.82E 07 1.31E 10 7.12E+01 1.07E+03 9.40E+01 2.22E 01 20 1.0 0.00 6.64 12.06 4.02E 08 7.32E 07 1.15E 05 5.19E 09 2.06E+03 4.14E+04 2.94E+03 8.77E+00 20 O.07 4.03 7.31 2.44E-08 4.44E 07 6.96E 06 3.15E 09 1.25E+03 2.51E+04 1.79E+03 5.32E+00 20 0.15 0.90 1.65 5.44E 09 9.90E-08 1.55E 06 7.02E 10 2.94E+02 5.62E+03 4.15E+02 1.19E+00 20 0.22 0.07 0.13 4.47E 10 8.13E 09 1.27E 07 5.76E-11 4.25E+01 4.80E+02 5.24E+01 9.74E-02 20 1.5 0.00 3.90 7.08 2.36E 08 4.29E 07 6.74E-06 3.04E-09 1.21E+03 2.43E+04 1.73E+03 5.15E+00 20 0.11 2.37 4.29 1.43E-08 2.60E 07 4.09E 06 1.85E-09 7.39E+02 1.48E+04 1.06E+03 3.12E+00 20 0.22 0.53 0.M 3.19E 09 5.81E 08 9.12E 07 4.12E-10 1.81E+02 3.31E+03 2.52E+02 6.96E 01 20

)

0.32 0.04 0.08 2.62E 10 4.77E-09 7.48E 06 3.38E 11 3.32E+01 2.90E+02 3.90E+01 5.72E 02 20-l 2.0 0.00 0.60 1.04 3.45E 09 8.19E-08 8.41E 07 4.20E-10 1.94E+02 4.65E+03 3.41E+02 9.65E-01 20 0.14 0.37 0.63 2.09E 09 4.97E 08 5.10E 07 2.55E 10 1.25E+02 2.83E+03 2.15E+02 5.85E-01 20 0.28 0.08 0.14 4.67E 10 1.11E-08 1.14E-07 5.68E 11 4.35E+01 6.47E+02 6.35E+01 1.31E 01 20 0.42 0.01 0.01 3.83E 11 9.10E 10 9.34E-09 4.66E 12 2.19E+01 7.15E+01 2.36E+01 1.07E 02 20 3.0 0.00 0.35 0.61 2.03E 09. 4.82E-08 4.87E-07 2.47E-10 1.22E+02 2.75E+03 2.09E+02 5.68E 01 20 0.20 0.21 0.37 1.23E-09 2.92E-08 2.95E-07 1.50E 10' 8.20E+01 1.67E+03 1.35E+02 3.44E-01 20 0.39 0.05 0.08 2.75E 10 6.52E 09 6.59E 08 3.34E-11 3.38E+01 3.89E+02 4.56E+01 7.69E 02 20 O.59 0.00 0.01 2.26E 11 5.36E-10 5.41E 09 2.74E 12 2.11E+01 5.03E+01 2.21E+01 6.31E-03 20 l

4.0 0.00 0.09 0.15 5.36E 10 1.15E-06 9.82E-08 6.11E 11 4.70E+01 6.69E+02 5.60E+01 1.08E-01 20 0.25 0.05 0.09 3.25E-10 6.95E 09 5.96E 08 3.71E 11 3.64E+01 4.14E+02 4.18E+01 6.55E 02 20 l

0.50 0.01 0.02 7.26E 11 1.55E-09 1.33E-08 8.27E 12 2.37E+01 1.00E+02 2.49E+01 1.46E-02 20 0.75 0.00 0.00 5.96E-12 1.27E-10 1.09E-09 6.79E 13 2.03E+01 2.72E+01 2.04E+01 1.20E 03 20 l

l

I t

State of Taxas 1995 Graded Exercise 06-December-1995 R

REAL TIME:

10:00 RELATIV H+03:00 i

eeeee****************************************************E TIME:

OFFSITE RADIOLOGICAL SURVEY DATA

      • ee***************************************************************************

METEOROLOGICAL DATA----------


RELEASE DATA---------------

WIND SPEED (MPH) 7.00 NOBLE GAS (CI/SEC) 3.557E+00 DELTA-T (DEG. F/50M)

-0.80 IODINE (CI/SEC) 1.351E-02 t

STABILITY CLASS (PASQUILL)'

230.0 TOTAL (CI/SEC) 3.732E+00 D

PARTICULATE (CI/SEC) 1.616E-01 l

WIND DIRECTION (DEGREES) i PLUME TRAVEL (MI) 6.262E+00 AVERAGE

  • GAMMA (MEV/ DIS)

O.62 l

PLUME TRAILING EDGE (MI) 0.000E+00 AVERAGE BETA (MEV/ DIS) 0.32 1995 Graded Exercise LOCATION l

DOSE RATE l

AIR CONCENTRATION l AIR SAMPLE CPN l GROU W DEPOSITION l BACKGROUN DOWN DIST.

CLOSED OPEN GROSS GROSS NOBLE IG>lNE GROSS GROSS GROSS NET BACKGROUN WIND OFF WINDOW WINDOW IODINE PART.

GAS 131 10 DINE PART.

DEPOSIT.

GROUW COUNT DIST CENT.

DOSE R.

DOSE R.

ACTIVITY ACTIVITY ACTIVITY ACTIVITY COUNT R.

COUNT R.

COUNT R.

DEPOSIT.

RATE (MI) (MI)

(NR/NR)

(MR/NR) (UC1/CC).(UCI/CC)

(UCI/CC)

(UCl/CC)

(CPN)

(CPN)

(CPM)

(UCI/N2)

(CPM) 2 0.5 0.00 50.51 96.08 3.78E-07 4.53E 06 1.04E 04 5.16E 08 1.91E+04 2.56E+05 1.93E+04 5.80E+01 20 0.04 30.64 58.27 2.30E 07 2.75E 06 6.28E 05 3.13E-08 1.16E+04 1.55E+05 1.17E+04 3.52E+01 20 0.08 6.84 13.00 5.12E 08 6.13E 07 1.40E 05 6.98E 09 2.60E+03 3.47E+04 2.63E+03 7.85E+00 20 0.12 0.56 1.07 4.20E 09 5.03E 08 1.15E 06 5.73E-10 2.31E+02 2.87E+03 2.35E+02 6.44E 01 20 1.0 0.00 22.82 43.40 1.66E 07 1.99E 06 4.68E 05 2.26E 08 8.37E+03 1.12E+05 8.49E+03 2.54E+01 20 0.07 13.84 26.32 1.01E 07 1.20E-06 2.84E 05 1.37E 08 5.00E+03 6.82E+04 5.16E+03 1.54E+01 20 0.15 3.09 5.87 2.25E 08 2.69E 07 6.34E 06 3.06E-09 1.15E+03 1.52E+04 1.17E+03 3.44E+00 20 0.22 0.25 0.48 1.84E 09 2.21E-08 5.20E-07 2.51E 10 1.13E+02 1.27E+03 1.14E+02 2.83E 01 20 1.5 0.00 13.39 25.48 9.74E 08 1.17E'06 2.75E 05 1.33E 08 4.92E+03 6.60E+04 4.99E+03 1.49E+01 20 0.11 8.12 15.45.5.91E-08 7.07E 07 1.67E-05 8.05E 09 2.99E+03 4.00E+04 3.03E+03 9.05E+00 20 0.22 1.81 3.45 1.32E 08 1.58E 07 3.72E 06 1.80E 09 6.83E+02 8.95E+03 6.93E+02 2.02E+00 20 0.32 0.15 0.28 1.08E 09 1.29E-08 3.05E 07 1.47E 10 7.44E+01 7.53E+02 7.52E+01 1.66E-01 20 2.0 0.00 2.25 4.09 1.29E 06 2.34E-07 3.90E 06 1.66E 09 6.66E+02 1.33E+04 9.81E+02 2.89E+00 20 0.14 1.37 2.48 7.80E 09 1.42E-07 2.37E 06 1.01E 09 4.12E+02 8.06E+03 6.03E+02 1.75E+00 20 0.28 0.30 0.55 1.74E-09 3.17E 08 5.28E 07 2.25E-10 1.07E+02 1.81E+03 1.50E+02 3.91E 01 20 0.42 0.03 0.05 1.43E 10 2.60E-09 4.34E 08 1.84E 11 2.72E+01 1.67E+02 3.07E+01 3.21E 02 20 3.0 0.00 1.31 2.37 7.57E 09 1.38E 07 2.26E 06 9.TTE 10 4.01E+02 7.82E+03 5.86E+02 1.70E+00 20 0.20 0.79 1.44 4.59E-09 8.36E-08 1.37E 06 5.92E 10 2.51E+02 4.75E+03 3.63E+02 1.03E+00 20 0.39 0.18 0.32 1.02E-09 1.87E-08 3.06E 07 1.32E 10 7.15E+01 1.00E+03 9.66E+01 2.30E-01 20 0.59 0.01 0.03 8.41E 11 1.53E 09 2.51E-08 1.09E 11 2.42E+01 1.07E+02 2.63E+01 1.89E 02 20 I-4.0 0.00 0.20 0.35 1.14E 09 2.71E 08 2.84E 07 1.39E 10 7.74E+01 1.55E+03 1.29E+02 3.29E-01 20 0.25 0.12 0.21 6.92E 10 1.64E 08 1.72E 07 8.42E-11 5.48E+01 9.50E+02 8.64E+01 1.99E 01 20 0.50 0.03 0.05 1.54E 10 3.67E-09 3.85E-08 1.88E-11 2.78E+01 2.28E+02 3.48E+01 4.45E-02 20 4

0.75 0.00 0.00 1.27E-11 3.01E 10 3.16E-09 1.54E 12 2.06E+01

3. 70E+01 2.12E+01 3.65E-03 20 y

w

^

State of Taxa 3 1995 Graded Exercise 06-December-1995 REAL TIME:

10:00 RELATIVE TIME:

H+03:00 LOCAT!0N l

DOSE RATE l

AIR CONCENTRATION l AIR SAMPLE CPM l GROUND DEPOSITION l BActGROUN DOWN DIST.

CLOSED OPEN GROSS GROSS NOBLE IODINE GROSS GROSS GROSS NET SACKGROUN WIND OFF WINDOW WINDOW IODINE PART.

GAS 131 10 DINE PART.

DEPOSIT.

GROUND COUNT DIST CENT.

DOSE R.

DOSE R.

ACTIVITY ACTIVITY ACTIVITY ACTIVITY COUNT R.

COUNT R.

COUNT R.

DEPOSIT.

RATE (MI) (MI)

(MR/NR) (MR/NR) (UCl/CC) (UCl/CC) (UCI/CC) (UCl/CC)

(CPM)

(CPM)

(CPM)

(UCI/M2)

(CPM) 5.0 0.00 0.06 0.09 3.32E 10 7.11E-09 6.28E 08 3.79E 11 3.67E+01 4.22E+02 4.23E+01 6.70E 02 20 0.30 0.03 0.06 2.01E 10 4.31E 09 3.81E 06 2.30E 11 3.01E+01 2.64E+02 3.35E+01 4.06E 02 20 0.60 0.01 0.01 4.50E-11 9.62E 10 8.50E-09 5.12E 12 2.23E+01 7.44E+01 2.30E+01 9.06E-03 20 0.89 0.00 0.00 3.69E-12 7.90E 11

<LLD 4.21E 13 2.02E+01 2.45E+01 2.02E+01 7.44E-04 20 6.0 0.00 0.04 0.07 2.67E 10 5.72E 09 4.98E-08 3.05E 11 3.34E+01 3.44E+02 3.79E+01 5.39E-02 20 0.34 0.03 0.04 1.62E 10 3.47E 09 3.02E-08 1.85E 11 2.82E+01 2.16E+02 3.09E+01 3.27E 02 20 0.69 0.01 0.01 3.62E 11 7.74E 10 6.74E-09 4.12E-12 2.18E+01 6.38E+01 2.24E+01 7.29E 03 20 1.03 0.00 0.00 2.97E 12 6.35E 11

<LLD 3.38E-13 2.01E+01 2.36E+01 2.02E+01 5.90E 04 20 1995 Graded Exercise t

4 i

)

l

-~-

State of Tcxas 1995 Graded Exercise 06-December-1995 REAL TIME:

10:15 RELATIV H+03:15 eeeeo****************************************************E TIME:

                            • w********

OFFSITE RADIOLOGICAL SURVEY DATA

  • eooe***************************************************************************

I


METEOROLOGICAL DATA----------


RELEASE DATA---------------

WIND SPEED (MPH) 7.00 NOBLE GAS (CI/SEC) 1.224E+01 DELTA-T (DEG. F/50M)

-0.80 IODINE (CI/SEC) 8.072E-02 STABILITY CLASS (PASQUILL)

D PARTICULATE (CI/SEC)

WIND DIRECTION (DEGREES) 230.0 TOTAL (CI/SEC) 4.038E-01 1.273E+01 PLUME TRAVEL (MI) 8.016E+00 AVERAGE GAMMA (MEV/ DIS) 0.57 PLUME TRAILING EDGE (MI) 0.000E+00 AVERAGE BETA (MEV/ DIS) 0.31 1995 Graded Exercise LOCATION l

DOSE RATE l

AIR CONCENTRATION l AIR SAMPLE CPM l GROUND DEPOE! TION l 8ACKGR

............................................................................................................. 6.....................

DOWN DIST.

CLOSED OPEN GROSS GROSS N08LE 10 DINE GROSS GROSS GROSS NET 8ACKGROUN WIND OFF WIIDOW WINDOW IQDINE PART.

GAS 131 10 DINE PART.

DEPOSIT.

GROUND COUNT DIST CENT.

DOSE R.

DOSE R.

ACTIVITY ACTIVITY ACTIVITY ACTIVITY COUNT R.

COUNT R.

COUNT R.

DEPOSIT.

RATE (MI)

(MI)

(MR/NR)

(MR/NR) (UCl/CC)

(UCI/CC) (UC1/CC)

(UC1/CC)

(CPM)

(CPM)

(CPM)

(UCI/M2)

(CPM) 0.5 0.00 152.50 302.59 2.26E-06 1.13E-05 3.56E 04 3.24E 07 1.14E+05 6.41E+05 5.39E+04 1.62E+02 20 0.04 92.49 183.53 1.37E-06 6.87E 06 2.16E 04 1.96E 07 6.90E+04 3.89E+05 3.27E+04 9.81E+01 20 0.08 20.64 40.95 3.06E 07 1.53E 06 4.82E 05 4.38E-08 1.54E+04 8.67E+04 7.31E+03 2.19E+01 20 l

0.12 1.69 3.36 2.51E 08 1.26E 07 3.96E-06 3.60E 09 1.28E+03 7.14E+03 6.18E+02 1.80E+00 20 1.0 0.00 68.90 136.72 9.92E 07 4.97E 06 1.61E 04 1.42E-07 4.99E+04 2.81E+05 2.36E+04 7.09E+01 20 0.07 41.79 82.92 6.01E 07 3.01E 06 9.78E 05 8.61E-08 3.03E+04 1.70E+05 1.43E+04 4.30E+01 20 0.15 9.32 18.50 1.34E 07 6.72E 07 2.18E 05 1.92E 08 6.7FE+03 3.80E+04 3.22E+03 9.60E+00 20 0.22 0.77 1.52 1.10E 08 5.52E 08 1.79E-06 1.58E 09 5.74E+02 3.14E+03 2.82E+02 7.88E 01 20 l

1.5 0.00 40.45 80.26 5.82E 07 2.91E-06 9.46E 05 8.33E 08 2.93E+04 1.65E+05 1.39E+04 4.16E+01 20 0.11 24.53 48.68 3.53E 07 1.7FE-06 5.74E 05 5.05E 08 1.78E+04 1.00E+05 8.43E+03 2.52E+01 20 0.22 5.47 10.86 7.87E 08 3.94E 07 1.28E 05 1.13E-08 3.98E+03 2.23E+04 1.90E+03 5.63E+00 20 I

0.32 0.45 0.89 6.46E 09 3.24E 08 1.05E-06 9.26E 10 3.45E+02 1.85E+03 1.74E+02 4.62E-01 20 2.0 0.00 9.03 17.18 6.19E-08 7.42E 07 1.86E-05 8.44E 09 3.13E+03 4.20E+04 3.08E+03 9.18E+00 20 I

0.14 5.48 10.42 3.76E-08 4.50E 07 1.13E 05 5.12E-09 1.91E+03 2.55E+04 1.87E+03 5.57E+00 20 0.28 1.22 2.33 8.38E 09 1.00E 07 2.52E 06 1.14E 09 4.42E+02 5.70E+03 4.34E+02 1.24E+00 20 0.42 0.10 0.19 6.88E 10 8.24E 09 2.07E 07 9.38E 11 5.46E+01 4.86E+02 5.40E+01 1.02E-01 20 3.0 0.00 5.24 9.96 3.65E-08 4.37E 07 1.08E 05 4.97E 09 1.85E+03 2.47E+04 1.82E+03 5.41E+00 20 0.20 3.18 6.04 2.21E 08 2.65E-07 6.53E 06 3.01E 09' 1.13E+03 1.50E+04 1.11E+03 3.28E+00 20 0.39 0.71 1.35 4.93E-09 5.91E 08 1.46E 06 6.73E 10 2.68E+02 3.36E+03 2.64E+02 7.32E 01 20 0.59 0.06 0.11 4.05E 10 4.85E-09 1.20E 07 5.52E 11 4.04E+01 2.95E+02 4.00E+01 6.00E-02 20 4.0 0.00 0.89 1.61 4.96E 09 9.04E-08 1.54E-06 6.40E 10 2.69E+02 5.14E+03 3.79E+02 1.08E+00 20 0.25 0.54 0.98 3.01E 09 5.48E 08 9.34E-07 3.88E-10 1.71E+02 3.12E+03 2.38E+02 6.54E-01 20 0.50 0.12 0.22 6.71E 10 1.22E 06 2.08E 07 8.66E 11' 5.38E+01 7.12E+02 6.86E+01 1.46E 01 20,

i 0.75 0.01 0.02 5.51E-11 1.00E-09 1.71E-08 7.11E 12 2.28E+01 7.68E+01 2.40E+01 1.20E-02 20

Stcts of Tcxns 1995 Graded Exercise 06-December-1995 REAL TIME:

10:15 RELATIVE TIME:

H+03:15 LOCATION l

DOSE RATE l

AIR CONCENTRATION l AIR SAMPLE CPM l GROUND DEPOSITION l BACKGROUN DOWN DIST.

CLOSED OPEN GROSS GROSS NOBLE 10 DINE GROSS GROSS GROSS NET BACKGROUN WINO OFF WINDOW WINDOW ICDINE PART.

GAS 131 10 DINE PART.

DEPOSIT.

GROUND COUNT

{

DIST CENT.

DOSE R.

DOSE R.

ACTIVITY ACTIVITY ACTIVITY ACTIVITY COUNT R.

COUNT R.

COUNT R.

DEPOSIT.

RATE (MI)

(MI)

(MR/NR)

(MR/NR) (UCI/CC)

(UCI/CC) (UC1/CC)

(UC!/CC)

(CPM)

(CPM)

(CPM)

(UCl/M2)

(CPM) 1 5.0 0.00 0.15 0.26 8.24E 10 1.96E 08 2.12E-07 1.00E 10 6.15E+01 1.13E+03 9.62E+01 2.29E 01 20 0.30 0.09 0.16 5.00E 10 1.19E-08 1.29E 07 6.00E 11 4.51E+01 6.93E+02 6.62E+01 1.39E 01 20 0.60 0.02 0.04 1.12E-10 2.65E 09 2.87E 08 1.36E 11 2.56E+01 1.70E+02 3.03E+01 3.10E-02 20 0.89 0.00 0.00 9.16E 12 2.18E 10 2.36E-09 1.11E 12 2.05E+01 3.23E+01 2.00E+01 2.54E 03 20 6.0 0.00 0.12 0.21 6.63E-10 1.58E-08 1.68E-07 8.07E 11 5.34E+01 9.12E+02 8.13E+01 1.84E 01 20 0.34 0.07 0.13 4.02E 10 9.56E 09 1.02E-07 4.89E-11 4.02E+01 5.61E+02 5.72E+01 1.12E 01 20 0.69 0.02 0.03 8.97E-11 2.13E-09 2.28E-08 1.09E-11 2.45E+01 1.41E+02 2.83E+01 2.49E 02 20 1.03 0.00 0.00 7.37E-12 1.75E 10 1.87E-09 8.96E-13 2.04E+01 2.99E+01 2.07E+01 2.04E 03 20 7.0 0.00 0.04 0.06 2.14E-10 4.57E 09 4.09E-08 2.43E 11 3.07E+01 2.79E+02 3.43E+01 4.31E 02 20 0.38 0.02 0.04 1.30E 10 2.77E 09 2.48E 08 1.48E 11 2.65E+01 1.77E+02 2.87E+01 2.61E 02 20 0.77 0.00 0.01 2.89E 11 6.19E-10 5.54E 09 3.29E 12 2.15E+01 5.50E+01 2.19E+01 5.83E 03 20 1.15 0.00 0.00 2.37E 12 5.00E-11

<LLD 2.70E-13 2.01E+01 2.29E+01 2.02E+01 4.79E-04 20 8.0 0.00 0.03 0.05 1.83E-10 3.93E-09 3.47E-06 2.09E 11 2.92E+01 2.42E+02 3.23E+01 3.70E 02 20 0.42 0.02 0.03 1.11E 10 2.38E-09 2.10E 08 1.27E-11 2.56E+01 1.55E+02 2.75E+01 2.24E-02 20 0.85 0.00 0.01 2.48E-11 5.31E 10 4.69E-09 2.83E-12 2.12E+01 5.01E+01 2.17E+01 5.01E 03 20 1.27 0.00 0.00 2.04E 12 4.36E 11

<LLD 2.32E 13 2.01E+01 2.25E+01 2.01E+01 4.11E-04 20 1995 Graded Exercise a.

l

!~

Stata of Tcxas t

l l,1995 Graded Exercise 06-December-1995 REAL TIME:

10:30 RELATIVE TIME:

H+03:30

    • ceo***************************************************************************

OFFSITE RADIOLOGICAL SURVEY DATA l

    • eo****************************************************************************

l


METEOROLOGICAL DATA---------- ------------RELEASE DATA---------------

WIND SPEED (MPH) 7.00 NOBLE GAS (CI/SEC) 2.254E+01 l

DELTA-T (DEG. F/50M)

-0.80 IODINE (CI/SEC) 1.810E-01 STABILITY CLASS (PASQUILL)

D PARTICULATE (CI/SEC) 6.408E-01 WIND DIRECTION (DEGREES) 230.0 TOTAL (CI/SEC) 2.337E+01 PLUME TRAVEL (MI) 9.769E+00 AVERAGE GAMMA (MEV/ DIS) 0.54 PLUME TRAILING EDGE (MI) 0.000E+00 AVERAGE BETA (MEV/ DIS) 0.30 1995 Graded Exercise LOCATION l

DOSE RATE l

AIR CONCENTRATION l AIR SAMPLE CPM l GROUND DEPOSITION l BACKGROUN DOWN DIST.

CLOSED OPEN GROSS GROSS NOBLE 10 DINE GROSS GROSS

, GROSS NET BACKGROUN 1

WIND OFF WINDOW WINDOW

!ODINE PART.

GAS 131 10 DINE PART.

DEPOSIT.

GROUND COUNT DIST CENT.

DOSE R.

DOSE R.

ACTIVITY ACTIVITY ACTIVITY ACTIVITY COUNT R.

COUNT R.

COUNT R.

DEPos!T.

RATE (MI)

(MI)

(MR/HR) (MR/NR) (UCI/CC)

(UCI/CC)

(UCl/CC)

(UCI/CC)

(CPM)

(CPM)

(CPM)

(UCI/M2)

(CPM) 1 0.5 0.00 253.41 522.38 5.07E-06 1.80E-05 6.56E-04 7.60E-07 2.55E+05 1.02E+06 1.06E+05 3.19E+02 20 0.04 153.70 316.84 3.07E 06 1.09E 05 3.98E 04 4.61E-07 1.55E+05 6.17E+05 6.44E+04 1.93E+02 20 0.08 34.30 70.70 6.86E-07 2.43E 06 8.88E-05 1.03E-07 3.45E+04 1.38E+05 1.44E+04 4.31E+01 20 0.12 2.82 5.80 5.63E 08 2.00E 07 7.29E 06 8.44E-09 2.85E+03 1.13E+04 1.20E+03 3.54E+00 20 1.0 0.00 114.51 236.05 2.22E 06 7.88E 06 2.97E 04 3.33E 07 1.12E+05 4.46E+05 4.66E+04 1.40E+02 20 0.07 69.45 143.17 1.35E 06 4.7BE 06 1.80E 04 2.02E-07 6.78E+04 2.70E+05 2.83E+04 8.48E+01 20 0.15 15.50 31.95 3.01E 07 1.07E 06 4.02E-05 4.51E 08 1.52E+04 6.04E+04 6.32E+03 1.89E+01 20 0.22 1.27 2.62 2.47E 08 8.75E 06 3.30E-06 3.70E 09 1.26E+03 4.97E+03 5.37E+02 1.55E+00 20 l

1.5 0.00 67.22 138.57 1.30E-06 4.62E 06 1.74E 04 1.96E 07 6.56E+04 2.62E+05 2.73E+04 8.21E+01 20 0.11 40.77 84.05 7.91E 07 2.80E-06 1.06E 04 1.19E 07 3.98E+04 1.59E+05 1.66E+04 4.98E+01 20 0.22 9.10 18.75 1.77E 07 6.26E-07 2.36E 05 2.65E 08 8.90E+03' 3.54E+04 3.72E+03 1.11E+01 20 0.32 0.75 1.54 1.45E 08 5.14E 08-1.94E-06 2.17E 09 7.49E+02 2.93E+03 3.24E+02 9.12E-01 20 2.0

.0.00 27.30 54.16 3.70E-07 1.85E-06 6.40E 05 5.30E 08 1.86E+04 1.05E+05 8.72E+03 2.61E+01 20 0.14 16.56 32.85 2.24E 07 1.12E-06 3.88E-05 3.21E-08 1.13E+04 6.36E+04 5.30E+03 1.58E+01 20 0.28 3.69 7.33 5.01E 08 2.51E 07 8.66E-06 7.17E-09 2.54E+03 1.42E+04 1.20E+03 3.54E+00 20 0.42 0.30 0.60 4.11E-09 2.06E 08 7.11E 07 5.89E-10 2.27E+02 1.19E+03 1.17E+02 2.90E 01 20 3.0 0.00 15.82 31.39 2.18E-07 1.09E-06 3.71E-05 3.12E 08 1.10E+04 6.18E+04 5.14E+03 1.54E+01 20 0.20 9.59 19.04 1.32E 07 6.62E 07 2.25E-05 1.89E 08 6.66E+03 3.75E+04 3.13E+03 9.33E+00 20 l

0.39 2.14 4.25 2.95E 08 1.48E 07 5.02E 06 4.22E 09 1.50E+03 8.38E+03 7.13E+02 2.08E+00 20 0.59 0.18 0.35 2.42E-09 1.21E 08 4.12E-07 3.47E 10 1.42E+02 7.06E+02 7.69E+01 1.71E 01 20 i

4.0 0.00 3.56 6.77 2.39E 08 2.86E-07 7.33E 06 3.26E-09 1.22E+03 1.62E+04 1.19E+03 3.50E+00 20 0.25 2.16 4.11 1.45E 08 1.74E 07 4.45E 06 1.98E 09 7.49E+02 9.85E+03 7.28E+02 2.13E+00 20 0.50 0.48 0.92 3.23E 09 3.88E 08 9.92E-07 4.41E-10 1.83E+02 2.21E+03 1.78E+02 4.74E-01 20 0.75 0.04 0.08 2.65E-10 3.18E-09 8.15E-08 3.62E 11 3.33E+01 2.00E+02 3.30E+01 3.89E-02 20 "

f

Stcts of Trxes

,1995 Graded Exercise 06-December-1995 REAL TIME:

10:30 RELATIVE TIME:

H+03:30 LOCATION l

DOSE RATE l

AIR CONCENTRATION l AIR SAMPLE CPM l GROUND DEPOSITION l BACKGROUN 00 bad D!$T.

CLOSED CPEN GROSS GROSS NOBLE 10 DINE GROSS GROSS GROSS NET SACKGROUN WIND OFF WINDOW WIIDOW 10 DINE PART.

GAS 131 10 DINE PART.

DEPosti.

GROUND COUNT 015T CENT.

DOSE R.

DOSE R.

ACTIVITY ACTIVITY ACTIVITY ACTIVITY COUNT R.

COUNT R.

COUNT R.

DEPOSIT.

RATE (MI) (MI)

(MR/NR) (MR/NR) (UC!/CC) (UCI/CC)

(UCI/CC) (UCI/CC)

(CPM)

(CPM)

(CPM)

(UCI/M2)

(CPM) 5.0 0.00 0.66 1.20 3.58E 09 6.54E 08 1.15E 06 4.62E 10 2.00E+02 3.72E+03 2.77E+02 7.71E-01 20 0.30 0.40 0.73 2.17E 09 3.97E-08 6.97E-07 2.81E 10 1.29E+02 2.26E+03 1.76E+02 4.68E 01 20 0.60 0.09 0.16 4.85E-10 8.85E 09 1.56E 07 6.26E 11 4.44E+01 5.21E+02 5.47E+01 1.04E 01 20 j

i 0.89 0.01 0.01 3.98E-11 7.26E 10 1.28E-08 5.14E-12 2.20E+01 6.11E+01 2.29E+01 8.56E 03 20 1

]

6.0 0.00 0.52 0.95 2.88E 09 5.26E 08 9.11E 07 3.72E-10 1.65E+02 3.00E+03 2.26E+02 6.20E-01 20 j

O.34 0.32 0.58 1.75E 09 3.19E 08 5.52E 07 2.26E 10 1.08E+02 1.83E+03 1.45E+02 3.76E-01 20

]

0.69 0.07 0.13 3.90E 10 7.12E 09 1.23E 07 5.04E 11 3.96E+01 4.23E+02 4.79E+01 8.39E 02 10 l

l 1.03 0.01 0.01 3.20E-11 5.84E-10 1.01E-08 4.13E 12 2.16E+01 5.31E+01 2.23E+01 6.89E-03 20 j

7.0 0.00 0.10 0.17 5.30E 10 1.26E 08 1.38E 07 6.45E 11 4.67E+01 7.34E+02 6.88E+01 1.47E-01 20 f

0.38 0.06 0.10 3.21E 10 7.65E 09 8.38E-08 3.91E 11 3.62E+01 4.53E+02 4.96E+01 8.89E-02 20 0.77 0.01 0.02 7.17E 11 1.71E 09 1.87E-08 8.72E 12 2.36E+01 1.17E+02 2.66E+01 1.98E-02 20 1.15 0.00 0.00 5.89E 12 1.40E-10 1.53E-09 7.16E 13 2.03E+01 2.79E+01 2.05E+01 1.63E-03 20 8.0 0.00 0.08 0.14 4.55E 10 1.08E 08 1.17E-07 5.53E 11 4.29E+01 6.33E+02 6.19E+01 1.26E-01 20

{

0.42 0.05 0.09 2.76E-10 6.57E 09 7.10E-08 3.36E 11 3.39E+01 3.92E+02 4.54E+01 7.63E 02 20 0.85 0.01 0.02 6.16E-11 1.47E-09 1.58E-08 7.49E 12 2.31E+01 1.03E+02 2.57E+01 1.70E-02 20 1.27 0.00 0.00 5.05E-12 1.20E 10 1.30E-09 6.15E 13 2.03E+01 2.68E+01 2.05E+01 1.40E-03 20 9.0 0.00 0.03 0.04 1.54E 1G 3.31E 09 2.99E 08 1.76E 11 2.78E+01 2.07E+02 3.04E+01 3.12E 02 20 0.46 0.02 0.03 9.37E-11 2.01E-09 1.82E 08 1.07E 11 2.47E+01 1.34E+02 2.63E+01 1.89E-02 20 0.92 0.00 0.01 2.09E-11 4.48E 10 4.05E 09 2.38E 12 2.11E+C1 4.54E+01 2.14E+01 4.22E 03 20 1.38 0.00 0.00 1.72E 12 3.68E-11

<LLD 1.96E 13 2.01E+01 2.21E+01 2.01E+01 3.46E-04 20 1995 Graded Exercise l

Stcto of Texas 1995 Graded Exercise 06-December-1995 REAL TIME:

10:45 RELATIVE TIME:

H+03:45

    • eoo***************w************'***********************************************

OFFSITE RADIOLOGICAL SURVEY DATA


METEOROLOGICAL DATA---------- ------------RELEASE DATA---------------

WIND SPEED (MPH) 7.00 NOBLE GAS (CI/SEC) 2.945E+01 DELTA-T (DEG. F/50M)

-0.80 IODINE (CI/SEC) 2.462E-01 STABILITY CLASS (PASQUILL)

D PARTICULATE (CI/SEC) 7.691E-01 WIND DIRECTION (DEGREES) 233.0 TOTAL (CI/SEC) 3.046E+01 PLUME TRAVEL (MI) 1.152E+01 AVERAGE GAMMA (MEV/ DIS) 0.51 PLUME TRAILING EDGE (MI) 0.000E+00 AVERAGE BETA (MEV/ DIS) 0.29 1995 Graded Exercise l

LOCATION l

DOSE RATE l

AIR CONCENTRATION l AIR SAMPLE CPM l GROUND DEPOSITION l 8ACKGROUN DOWN DIST.

CLOSED OPEN GROSS GROSS NOBLE IG)!NE GROSS GROSS GROSS NET 8ACKGROUN WIND OFF WINDOW WINDOW IG)!NE PART.

GAS 131 ICDINE PART.

DEPOSIT.

GROUND COUNT O!ST CENT.

DOSE R.

DOSE R.

ACTIVITY ACTIVITY ACTIVITY ACTIVITY COUNT R.

COUNT R.

COUNT R.

DEPOSIT.

RATE (MI)

(MI)

(MR/NR) (MR/NR) (UCI/CC)

(UCI/CC) (UC!/CC) (UC!/CC)

(CPM)

(CPM)

(CPM)

(UCI/M2)

(CPM) 0.5 0.00 304.03 648.82 6.90E-06 2.16E-05 8.57E-04 1.00E 06 3.47E+05 1.22E+06 1.60E+05 4.79E+02 20 0.04 184.40 393.53 4.18E 06 1.31E 05 5.20E-04 6.54E 07 2.10E+05 7.40E+05 9.68E+04 2.91E+02 20 O.08 41.15 87.81 9.33E 07 2.92E-06 1.16E 04 1.46E 07 4.70E+04 1.65E+05 2.16E+04 6.48E+01 20 0.12 3.38 7.21 7.66E-08 2.40E-U 9.52E-06 1.20E-08 3.87E+03 1.36E+04 1.79E+03 5.32E+00 20 1.0 0.00 137.39 293.19 3.02E 06 9.461-06 3.88E 04 4.73E 07 1.52E+05 5.35E+05 7.00E+04 2.10E+02 20 0.07 83.33 177.83 1.83E 06 5.74E-06 2.35E 04 2.87E 07 9.23E+04 3.25E+05 4.25E+04 1.27E+02 20 0.15 18.59 39.68 4.09E 07 1.28E 06 5.25E 05 6.40E 08 2.06E+04 7.24E+04 9.49E+03 2.84E+01 20 0.22 1.53 3.26 3.36E 08 1.05E 07 4.31E 06 5.25E 09 1.71E+03 5.96E+03 7.97E+02 2.33E+00 20 1.'5 0.00 80.65 172.12 1.77E-06 5.55E 06 2.28E-04 2.77E 07 8.93E+04 3.14E+05 4.11E+04 1.23E+02 20 0.11 48.92 104.40 1.00E-06 3.37E-06 1.38E-04 1.68E 07 5.42E+04 1.90E+05 2.49E+04 7.48E+01 20 0.22 10.92 23.29 2.40E 07 7.51E-07 3.08E 05 3.75E-08 1.21E+04 4.25E+04 5.58E+03 1.67E+01 20 0.32 0.90 1.91 1.97E-08 6.16E 08 2.53E-06 3.00E-09 1.01E+03 3.51E+03 4.76E+02 1.37E+00 20 2.0 0.00 45.37 93.53 8.29E 07 2.94E-06 1.18E 04 1.24E-07 4.17E+04 1.67E+05 1.72E+04 5.17E+01 20 0.14 27.52 5 6. 73 5.03E 07 1.78E 06 7.15E-05 7.54E 08 2.53E+04 1.01E+05 1.0$E+04 3.13E+01 20 0.28 6.14 12.66 1.12E-07 3.90E-07 1.59E 05 1.68E 08 5.67E+03 2.26E+04 2.35E+03 6.99E+00 20 0.42 0.50 1.04 9.21E 09 3.27E 08 1.31E-06 1.38E 09 4.83E+02 1.87E+03 2.11E+02 5.74E 01 20 3.0 0.00 26.29 54.20 4.88E 07 1.73E 06 6.82E-05 7.32E-08 2.46E+04 9.80E+04 1.01E+04 3.04E+01 20 0.20 15.95 32.87 2.96E 07 1.05E 06 4.14E 05 4.44E-08 1.49E+04 5.95E+04 6.16E+03 1.84E+01 20 0.39 3.56 7.34 6.61E-06 2.34E 07 9.24E 06 9.90E 09 3.34E+03 1.33E404 1.39E+03 4.12E+00 20 0.59 0.29 0.60 5.42E 09 1.92E 08 7.58E 07 8.13E 10 2.93E+02 1.11E+03 1 33E+02 3.38E 01 20 4.0 0.00 10.76 21.35 1.43E-07 7.16E 07 2.52E-05 2.04E 08 7.20E+03 4.05E+04 3.36E+(3 1.00E+01 20 0.25 6.53 12.95 8.66E 08 4.34E 07 1.53E-05 1.24E-08 4.37E+03 2.46E+04 2.04E+03 6.07E+00 20 0.50 1.46 2.89 1.93E-08 9.69E-08 3.42E 06 2.77E-09 9.92E+02 5.50E+03 4.71E+02 1.36E+00 20 0.75 0.12 0.24 1.59E-09 7.95E-09 2.80E 07 2.27E 10 9.97E+01 4.70E+02 5.71E+01 1.11E 01 20 t

2-e"-

I

'St to of Texas 1995 Graded Exercise 06-December-1995 REAL TIME:

10:45 RELATIVE TIME:

H+03:45 LOCATION l

DOSE RATE l

AIR CONCENTRATION l AIR SAMPLE CPM l GROUW DEPOSITION l 8ACKGROUN DOWN DIST.

CLOSED OPEN GROSS GROSS NOBLE ItBINE GROSS GROSS GROSS NET 8ACKGROUN WIND OFF WINDOW WIWOW ICBINE PART.

GAS 131 ItDINE PART.

DEPOSIT.

GROUS COLBli DIST CENT.

DOSE R.

DOSE R.

ACTIVITY ACTIVITY ACTIVITY ACTIVITY COUNT R.

COUNT R.

COUNT R.

DEPostT.

RATE (MI)

(MI)

(MR/NR)

(int /NR) (UCI/CC) (UCI/CC) (UCI/CC)

(UCI/CC)

(CPM)

(CPM)

(CPM)

(UCI/M2)

(CPM) 5.0 0.00 2.65 5.05 1.73E 08' 2.07E 07 5.47E-06 2.35E 09 8.88E+02 1.17E+04 8.58E+02 2.52E+00 20 0.30 1.61 3.06 1.05E 08 1.26E 07 3.32E 06 1.43E-09 5.47E+02 7.13E+03 5.28E+02 1.53E+00 20 0.60 0.36 0.68 2.34E-09 2.80E 08 7.40E 07 3.18E-10 1.38E+02 1.61E+03 1.33E+02 3.41E 01 20 0.89 0.03 0.06 1.92E 10 2.30E 09 6.00E 08 2.61E 11 2.96E+01 1.50E+02 2.93E+01 2.80E 02 20 6.0 0.00 2.10 4.00 1.39E 08 1.67E-07 4.34E 06 1.89E-09 7.19E+02 9.45E+03 6.94E+02 2.03E+00 20 0.34 1.28 2.43 8.42E-09 1.01E-07 2.63E 06 1.15E 09 4.44E+02 5.74E+03 4.29E+02 1.23E+00 20 0.69 0.28 0.54 1.88E-09 2.26E-08 5.87E 07 2.56E-10 1.15E+02 1.30E+03 1.11E+02 2.74E 01 20 1.03 0.02 0.04 1.54E 10 1.85E 09 4.82E 08 2.10E-11 2.78E+01 1.25E+02 2.75E+01 2.25E 02 20 7.0 0.00 0.43 0.78 2.30E-09 4.21E-08 7.48E,07 2.97E 10 1.36E+02 2.40E+03 1.84E+02 4.94E 01 20 4

0.38 0.26 0.47 1.40E-09 2.55E 08 4.54E 07 1.80E-10 9.03E+01 1.46E+03 1.20E+02 2.99E 01 20 0.77 0.06 0.11 3.12E 10 5.69E 09 1.01E-07 4.02E 11 3.57E+01 3.42E+02 4.22E+01 6.68E 02 20 1.15 0.00 0.01 2.56E 11 4.67E 10 8.31E 09 3.30E 12 2.13E+01 4.65E+01 2.18E+01 5.48E 03 20 i

i 8.0 0.00 0.36 0.66 1.98E-09 3.61E 08 6.34E-07 2.55E 10 1.19E+02 2.06E+G3 1.61E+02 4.24E 01 20 i !

0.42 0.22 0.40 1.20E 09 2.19E-08 3.85E 07 1.55E 10 8.03E+01 1.26E+03 1.06E+02 2.57E 01 20 O.85 0.05 0.09 2.68E 10 4.89E 09 8.58E 08 3.45E-11 3.35E+01 2.97E+02 3.91E+01 5.73E-02 20 i

1.27 0.00 0.01 2.20E 11 4.01E 10 7.05E-09 2.84E 12 2.11E+01 4.27E+01 2.16E+01 4.71E-03 20 i

9.0 0.00 0.07 0.12 3.83E 10 9.13E 09 1.01E 07 4.66E-11 3.93E+01 5.36E+02 5.52E+01 1.06E'-01 20 0.46 0.04 0.08 2.32E-10 5.54E 09 6.13E-08 2.83E-11 3.17E+01 3.33E+02 4.13E+01 6.41E 02 20 O.92 0.01 0.02 5.19E 11 1.24E 09 1.37E 08 6.31E 12 2.26E+01 8.99E+01 2.48E+01 1.43E 02 20 1.38 0.00 0.00 4.26E 12 1.01E-10 1.12E 09 5.18E 13 2.02E+01 2.57E+01 2.04E+01 1.17E-03 20 10.0 0.00 0.02 0.04 1.33E-10 2.84E 09 2.63E 08 1.51E 11 2.67E+01 1.81E+02 2.89E+01 2.68E 02 20 0.50 0.01 0.02 8.04E-11 1.72E 09 1.59E-08 9.16E 12 2.40E+01 1.18E+02 2.54E+01 1.62E 02, 20 0.99 0.00 0.01 1.79E 11 3.85E 10 3.56E 09 2.04E 12 2.09E+01 4.18E+01 2.12E+01 3.63E 03 20 1.49 0.00 0.00 1.47E-12 3.16E-11

<LLD 1.68E 13 2.01E+01 2.18E+01 2.01E+01 2.98E 04 20 1995 Graded Exercise l

Y a

1 Stcto of Texas

.1995 Graded Exercise 06-December-1995 REAL TIME:

11:00 RELATIVE TIME:

H+04:00 e*eo****************************************************************************

OFFSITE RADIOLOGICAL SURVEY DATA I

eeee***********+****************************************************************

i


METEOROLOGICAL DATA---------- ------------RELEASE DATA---------------

WIND SPEED (MPH) 7.00 NOBLE GAS (CI/SEC) 3.402E+01 DELTA-T (DEG. F/50M)

-0.90 IODINE (CI/SEC) 2.879E-01 STABILITY CLASS (PASQUILL)

D PARTICULATE (CI/SEC) 8.100E-01 WIND DIRECTION (DEGREES) 233.0 TOTAL (CI/SEC) 3.512E+01 PLUME TRAVEL (MI) 1.328E+01 AVERAGE GAMMA (MEV/ DIS) 0.49 PLUME TRAILING EDGE (MI) 0.000E+00 AVERAGE BETA (MEV/ DIS)

O.28 1995 Graded Exercise l

LOCATION l

DOSE RATE l

Alt CONCENTRATION l AIR SAMPLE CPM l GROUND DEPOSITION l BACKGROLRi 00bRI DIST.

CLOSED OPEN GROSS GROSS NOBLE

!G)!NE GROSS GROSS GROSS NET BACKGROUN WIND OFF WIIS0W WINDOW 10 DINE PART.

GAS 131 ICBINE PART.

DEPUSIT.

GROUND COUNT DIST CENT.

DOSE R.

DOSE R.

ACTIVITY ACTIVITY ACTIVITY ACTIVITY COUNT R.

COUNT R.

COUNT R.

DEPOSIT.

RATE (MI) (MI)

(MR/NR) (MR/NR) (UCI/CC)

(UC1/CC) (UCI/CC) (UC1/CC)

(CPM)

(CPM)

(CPM)

(UCI/M2)

(CPM) 0.5 0.00 326.22 718.42 8.06E 06 2.27E 05 9.90E 04 1.31E-06 4.06E+05 1.28E+06 2.05E+05 6.16E+02 20 0.04 197.86 435.74 4.89E 06 1.38E 05 6.01E-04 7.96E 07 2.46E+05 7.79E+05 1.24E+05 3.73E+02 20 0.08 44.15 97.23 1.09E 06 3.07E 06 1.34E-04 1.7?E-07 5.49E+04 1.74E+05 2.78E+04 8.33E+01 20 0.12 3.62 7.98 8.96E 08 2.52E 07 1.10E-05 1.45E-08 4.53E+03 1.43E+04 2.30E+03 6.84E+00 20 J

1.0 0.00 147.42 324.67 3.54E 06 9.96E-06 4.48E-04 5.74E-07 1.78E+05 5.64E+05 8.99E+04 2.70E+02 20 0.07 89.42 196.92 2.15E 06 6.04E-06 2.72E 04 3.40E 07 1.00E+05 3.42E+05 5.46E+04 1.64E+02 20 0.15 19.95 43.94 4.79E-07 1.35E 06 6.06E 05 7.77E 06 2.41E+04 7.63E+04 1.22E+04 3.65E+01 20 0.22 1.64 3.61 3.93E 08 1.11E 07 4.90E-06 6.38E 09 2.00E+03 6.28E+03 1.02E+03 3.00E+00 20 1.5 0.00 86.55 190.60 2.08E 06 5.84E 06 2.63E 04 3.37E 07 1.04E+05 3.31E+05 5.28E+04 1.58E+02 20 0.11 52.49 115.60 1.26E 06 3.54E 06 1.59E 04 2.04E 07 6.33E+04 2.01E+05 3.20E+04 9.61E+01 20 0.22 11.71 25.79 2.81E-07 7.91E 07 3.56E 05 4.56E 08 1.41E+04 4.48E+04 7.16E+03 2.14E+01 20 0.32 0.96 2.12 2.31E 08 6.49E 08 2.92E 06 3.74E 09 1.18E+03 3.69E+03 6.06E+02 1.76E+00 20 2.0 0.00 54.44 116.18 1.13E-06 3.53E-06 1.54E-04 1.76E-07 5.68E+04 2.00E+05 2.59E+04 7.76E+01 20 0.14 33.02 70.47 6.84E 07 2.14E-06 9.33E 05 1.07E 07 3.44E+04 1.21E+05 1.57E+04 4.71E+01 20 0.28 7.37 15.72 1.53E-07 4.78E 07 2.08E 05 2.39E 08 7.70E+03 2.71E+04 3.52E+03 1.05E+01 20 0.42 0.60 1.29 1.25E 08 3.92E 08 1.71E 06 1.96E 09 6.51E+02 2.24E+03 3.07E+02 8.62E 01 20 3.0 0.00 31.55 67.33 6.64E 07 2.00E-06 8.91E-05 1.04E-07 3.34E+04 1.18E+05 1.52E+04 4.57E+01

- 20 0.20 19.13 40.84 4.03E 07 1.26E 06 5.41E-05 6.30E-06 2.03E+04 7.14E+04 9.25E+03 2.77E+01 20 0.39 4.27 9.11 8.99E 06 2.81E-07 1.21E 05 1.41E 08 4.54E+03 1.59E+04 2.00E+03 6.18E+00 20 0.59 0.35 0.75 7.38E-09 2.31E 06 9.90E 07 1.15E 09 3.91E+02 1.33E+03 1.89E+02 5.07E-01 20 1

4.0 0.00 17.89 36.87 3.20E 07 1.14E-06 4.65E-05 4.80E 08 1.61E+04 6.43E+04 6.61E+03 1.98E+01 20 0.25 10.85 22.36 1.94E-07 6.89E-07 2.82E-05 2.91E-06 9.78E+03 3.90E+04 4.02E+03 1.20E'+01 20 0.50 2.42 4.99 4.33E 08 1.54E 07 6.29E 06 6.49E 09 2.20E+03 8.72E+03 9.12E+02 2.68E+00 20,

0.75 0.20 0.41 3.55E 09 1.26E-08 5.16E-07 5.33E 10 1.99E+02 7.34E+02 9.32E+01 2.20E 01 20 l

i m

w

l l

St&to of Tcx2.s 1995 Graded Exercise 06-December-1995 REAL TIME:

11:00 RELATIVE TIME:

H+04:00 LOCATION l

DOSE RATE l

AIR CONCENTRATION l AIR SAMPLE CPM l GROUND DEPOSITION l 8ACKGROUN j

DOW DIST.

CLOSED GPEN GROSS GROSS NOBLE IODINE GROSS GROSS GROSS NET ammu l

WIND OFF WINDOW WINDOW 10 DINE PART.

GAS 131 10 DINE PART.

DEPOSIT.

GROUS COUNT I

O!ST CENT.

DOSE R.

DOSE R.

ACTIVITY ACTIVITY ACTIVITY ACTIVITY COUNT R.

COUNT R.

COUNT R.

DEPOSIT.

RATE i

(MI) (MI)

(eNt/lut) (MR/NR) (UCI/CC) (UCl/CC) (UCI/CC) (UCI/CC)

(CPM)

(CPM)

(CPM)

(UCI/M2)

(CPM) 5.0 0.00 8.02 15.91 1.03E 07 5.18E 07 1.88E 05 1.48E 08 5.21E+03 2.93E+04 2.42E+03 7.20E+00 20 0.30-4.56 9.65 6.25E 06 3.14E 07 1.14E 05 8.96E 09 3.17E+03 1.78E+04 1.47E+03 4.37E+00 20 l

0.60 1.09 2.15 1.40E-08 7.01E-08 2.55E 06 2.00E 09 7.22E+02 3.90E+03 3.44E+02 9.74E 01 20 0.89 0.09 0.18 1.15E-09 5.75E 09 2.09E 07 1.64E 10 7.76E+01 3.45E+02 4.66E+01 8.00E-02 20 l

6.0 0.00 6.36 12.62 8.30E-08 4.17E 07 1.49E-05 1.19E-08 4.19E+03 2.36E+04 1.95E+03 5.79E+00 20 0.34 3.86 7.65 5.03E 08 2.53E 07 9.05E 06 7.21E-09 2.55E+03 1.43E+04 1.19E+03 3.51E+00 20 0.69 0.86 1.71 1.12E-08 5.64E 06 2.02E 06 1.61E-09 5.85E+02 3.21E+03 2.81E+02 7.84E 01 20 1.03 0.07 0.14 9.22E 10 4.63E 09 1.66E 07 1.32E 10 6.64E+01 2.82E+02 4.14E+01 6.44E 02 20 7.0 0.00 1.73 3.28 1.11E 08 1.33E 07 3.56E 06 1.51E-09 5.78E+02 7.56E+03 5.57E+02 1.61E+00 20 0.38 1.05 1.99 6.73E 09 8.09E 08 2.16E 06 9.18E 10 3.59E+02 4.60E+03 3.'46E+02 9.78E-01 20 0.77 0.23 0.44 1.50E 09 1.80E 08 4.82E 07 2.05E-10 9.56E+01 1.04E+03 9.26E+01 2.18E 01 20 1.15 0.02 0.04 1.23E-10 1.48E 09 3.96E 08 1.68E 11 2.62E+01 1.04E+02 2.60E+01' 1.79E 02 20 8.0 0.00 1.46 2.79 9.53E-09 1.14E 07 3.02E 06 1.30E-09 4.99E+02 6.50E+03 4.81E+02 1.38E+00 20

- '~

0.42 0.89 1.69 5.78E 09 6.94E-08 1.83E 06 7.88E 10 3.11E+02 3.95E+03 2.99E+02 8.39E-01 20 0.85 0.20 0.38 1.29E 09 1.55E-08 4.09E 07 1.76E-10 8.49E+01 8.96E+02 8.24E+01 1.87E-01 20 1.27 0.02 0.03 1.06E 10 1.27E 09 3.36E 08 1.44E-11 2.53E+01 9.19E+01 2.51E+01 1.54E 02 20 9.0 0.00 0.31 0.57 1.67E 09 3.05E-08 5.48E-07 2.15E 10 1.04E+02 1.74E+03 1.38E+02 3.56E 01 20 0.46 0.19 0.35 1.01E-09 1.85E 06 3.32E-07 1.30E 10 7.00E+01 1.07E+03 9.18E+01 2.16E 01 20 0.92 0.04 0.08 2.25E 10 4.12E-09 7.41E-06 2.91E 11 3.13E+01 2.53E+02 3.60E+01 4.81E-02 20 1.38 0.00 0.01 1.85E 11' 3.38E-10 6.00E 09 2.39E-12 2.09E+01 3.91E+01 2.13E+01 3.95E-03 20 10.0 0.00 0.06 0.11 3.29E 10 7.84E 09 8.87E-08 4.00E 11 3.65E+01 4.64E+02 5.01E+01 9.04E 02 20 0.50 0.04 0.07 1.99E 10 4.76E-09 5.38E-08 2.43E 11 3.00E+01 2.89E+02 3.83E+01 5.48E 02 20 0.99 0.01 0.01 4.45E 11 1.06E-09 1.20E 08 5.41E 12 2.22E+01 8.00E+01 2.41E+01 1.22E-02 20 1.49 0.00 0.00 3.65E-12 8.71E 11

<LLD 4.44E 13 2.02E+01 2.49E+01 2.03E+01 1.00E-03 20 1995 Graded Exercise i

l k

T b

StGtd of T;xna 1995 Graded Exercise 06-December-1995 REAL TIME:

11:15 RELATIVE TIME:

H+04:15 eeee****************************************************************************

OFFSITE RADIOLOGICAL SURVEY DATA coee****************************************************************************


METEOROLOGICAL DATA----------


RELEASE DATA---------------

WIND SPEED (MPH) 8.00 NOBLE GAS (CI/SEC) 3.699E+01 DELTA-T (DEG. F/50M)

-0.90 IODINE (CI/SEC) 3.137E-01 STABILITY CLASS (PASQUILL)

D PARTICULATE (CI/SEC) 8.004E-01 WIND DIRECTION (DEGREES) 233.0 TOTAL (CI/SEC) 3.811E+01 PLUME TRAVEL (MI) 1.528E+01 AVERAGE GAMMA (MEV/ DIS) 0.47 PLUME TRAILING EDGE (MI) 0.000E+00 AVERAGE BETA (MEV/ DIS) 0.28 1995 Graded Exercise LOCATION l

DOSE RATE l

AIR CONCENTRATION l AIR SAMPLE CPM l GROUND DEPOSITION l BACKGROUN DOWN DIST.

CLOSED OPEN GROSS GROSS NOBLE 10 DINE GROSS GROSS GROSS NET BACKGROUN WIND OFF WINDOW WINDOW IODINE PART.

GAS 131 10 DINE PART.

" DEPOSIT.

GROUND COUNT DIST CENT.

DOSE R.

DOSE R.

ACTIVITY ACTIVITY ACTIVITY ACTIVITY COUNT R.

COUNT R.

COUNT R.

DEPOSIT.

RATE (MI)

(MI)

(MR/HR)

(MR/NR) (UCI/CC)

(UCI/CC) (UCI/CC) (UCI/CC)

(CPM)

(CPM)

(CPM)

(UCl/M2)

(LeM) 0.5 0.00 290.40 658.26 7.69E-06 1.96E-05 9.42E 04 1.29E-06 3.87E+05 1.11E+06 2.29E+05 6.87E+02 20 0.04 176.14 399.25 4.66E 06 1.19E-05 5.71E-04 7.85E-07 2.35E+05 6.76E+05 1.39E+05 4.17E+02 20 0.08 39.30 89.09 1.04E-06 2.66E 06 1.27E 04 1.75E 07 5.24E+04 1.50E+05 3.10E+04 9.30E+01 20 0.12 3.23 7.31 8.54E-06 2.18E 07 1.05E 05 1.44E-08 4.32E+03 1.24E+04 2.56E+03 7.64E+00 20 1.0 0.00 131.25 297.50 3.37E-06 8.61E 06 4.26E 04 5.67E 07 1.70E+05 4.87E+05 1.00E+05 3.01E+02 20 0.07 79.60 180.44 2.05E 06 5.22E-06 2.58E-04 3.44E-07 1.03E+05 2.96E+05 6.09F+04 1.83E+02 20 0.15 17.76 40.26 4.56E-07 1.17E-06 5.77E-05 7.68E-08 2.30E+04 6.60E+04 1.360+%

4.08E+01 20 0.22 1.46 3.30 3.75E-08 9.57E 08 4.73E-06 6.30E 09 1.90E+03 5.43E+03 1.14E+03 3.15E+00 20 1

1.5 0.00 77.05 174.65 1.98E-06 5.05E 06 2.50E-04 3.33E-07 9.95E+04 2.86E+05 5.89E+04 1.77E+02 20 0.11 46.73 105.93 1.20E-06 3.06E 06 1.52E-04 2.02E-07 6.04E+04 1.73E+05 3.58E+04 1.07E+02 20 0.22 10.43 23.64 2.68E 07 6.84E-07 3.39E-05 4.51E-08 1.35E+04 3.87E+04 7.99E+03 2.39E+01 20 0.32 0.86 1.94 2.20E-08 5.61E 08 2.78E 06 3.70E-09 1.13E+03 3.20E+03 6.74E+02 1.97E+00 20 2.0 0.00 51.12 112.58 1.15E 06 3.25E 06 1.56E-04 1.87E 07 5.81E+04 1.84E+05 3.13E+04 9.40E+01 20 0.14 31.01 68.29 7.00E-07 1.97E 06 9.44E 05 1.14E-07 3.52E+04 1.12E+05 1.90E404 5.70E+01 20 0.28 6.92 15.24 1.56E-07 4.40E-07 2.11E 05 2.54E 03 7.88E+03 2.49E+04 4.25E+03 1.27E+01 20 0.42 0.57 1.25 1.28E-08 3.62E 08 1.73E-06 2.08E 09 6.65E+02 2.07E+03 3.68E+02 1.04E+00 20 3.0 0.00 29.62 65.24 6.80E-07 1.92E-06 9.01E-05 1.10E 07 3.42E+04 1.08E+05 1.84E+04 5.53E+01 20 0.20 17.97 39.57 4.12E-07 1.16E-06 5.47E-05 6.70E 08 2.08E+04 6.58E+04 1.12E+04 3.36E+01 20 0.39 4.01 8.83 9.20E 08 2.59E 07 1.22E-05 1.49E-08 4.65E+03 1.47E+04 2.51E+03 7.49E+00 20 0.59 0.33 0.72 7.55E 09 2.13E 08 1.00E-06 1.23E-09 4.00E+02 1.22E+03 2.25E+02 6.15E-01 20 4.0 0.00 18.78 40.08 3.81E-07 1.19E-06 5.31E-05 5.95E-08 1.92E+04 6.75E+04 9.23E+03 2.76E+01 20 0.25 11.39 24.31 2.31E-07 7.24E-07 3.22E-05 3.61E 08 1.16E+04 4.10E+04 5.60E+03 1.68E+01 20 0.50 2.54 5.42 5.16E-08 1.61E-07 7.19E 06 8.06E 09 2.61E+03 9.16E+03 1.27E+03 3.74E+00 20 0.75 0.21 0.45 4.23E-09 1.33E 08 5.90E 07 6.61E-10 2.33E+02 7.70E+02 1.22E+02 3.07E-01 20

_7 State of Tsxa2s 3

,1995 Graded Exercise 06-December-1995 REAL TIME:

11:15 RELATIVE TIME:

H+04:15 LOCATION l

DOSE RATE l

AIR CONCENTRATION l AIR SAMPLE CPM l GROUND DEPOSITION l BACKGROUN Dolai DIST.

CLO8ED GPEN GROSS GROSS NOBLE 10 DINE GROSS GROSS GROSS NET BACKGROUN WIND OFF WIIS0W WINDOW ICDINE PART.

GAS 131 ICDINE PART.

DEPOSIT.

GROUND COUNT DIST CENT.

DOSE R.

DOSE R.

ACTIVITY ACTIVITY ACTIVITY ACTIVITY COUNT R.

COUNT R.

COUNT R.

DEP0 BIT.

RATE (MI)

(MI)

(MR/NR) (MR/NR) (UCl/CC)

(UCI/CC) (UCI/CC)

(UCI/CC)

(CPM)

(CPM)

(CPM)

(UCl/M2)

(CPM) 5.0 0.00 11.66 24.05 2.02E 07 7.19E 07 3.03E 05 3.03E-08 1.02E+04 4.07E+04 4.36E+03 1.30E+01 20 0.30 7.07 14.58 1.23E 07 4.36E 07 1.84E 05 1.84E 08 6.19E+03 2.47E+04 2.65E+03 7.90E+00 20 0.60 1.58 3.25 2.74E-08 9.73E-08 4.11E 06 4.10E-09 1.40E+03 5.53E+03 6.07E+02 1.76E+00 20 0.89 0.13 0.27 2.25E 09 7.99E 09 3.37E 07 3.37E 10 1.33E+02 4.72E+02 6.82E+01 1.45E-01 20 6.0 0.00 9.25 19.07 1.63E 07 5.78E 07 2.40E 05 2.44E 08 8.21E+03 3.27E+04 3.51E+03 1.05E+01 20 0.34 5.61 11.56 9.87E 06 3.51E 07 1.46E 05 1.48E 08 4.99E+03 1.99E+04 2.14E+03 6.36E+00 20 0.69 1.25 2.58 2.20E 08 7.83E 08 3.25E 06 3.30E 09 1.13E+03 4.45E+03 4.92E+02 1.42E+00 20 1.03 0.10 0.21 1.81E 09 6.43E 09 2.67E-07 2.71E 10 1.11E+02 3.84E+02 5.88E+01 1.16E 01 20 7.0 0.00 4.57 9.06 5.00E 08 2.92E-07 1.07E-05 8.31E-09 2.94E+03 1.65E+04 1.41E+03 4.16E+00 20 0.38 2.77 5.50 3.52E 08 1.TTE-07 6.51E*06 5.04E 09 1.79E+03 1.00E+04 8.60E+02 2.52E+00 20 O.77 0.62 1.23 7.85E 09 3.95E 08 1.45E 06 1.12E-09 4.15E+02 2.25E+03 2.07E+02 5.63E 01 20 1.15 0.05 0.10 6.44E-10 3.24E-09 1.19E 07 9.23E 11 5.24E+01 2.03E+02 3.54E+01' 4.62E 02 20 8.0 0.00 3.87 7.69 4.98E 08 2.50E 07 9.10E-06 7.13E-09 2.52E+03 1.42E+04 1.21E+03 3.57E+00 20 0.42 2.35 4.66 3.02E 08 1.52E 07 5.52E 06 4.33E-09 1.54E+03 8.61E+03 7.41E+02 2.17E+00 20 0.85 0.52 1.04 6.74E 09 3.39E 08 1.23E 06 9.65E 10 3.59E+02 1.94E+03 1.81E+02 4.83E-01 20 1.27 0.04 0.09 5.53E 10 2.78E 09 1.01E 07 7.92E-11 4.78E+01 1.77E+02 3.32E+01 3.97E 02 20 9.0 0.00 1.11 2.10 7.02E-09 8.44E-08 2.20E 06 9.57E 10 3.73E+02 4.80E+03 3.68E+02 1.04E+00 20 0.46 0.67

. 1.28 4.26E-09 5.12E 08 1.38E 06 5.81E 10 2.34E+02 2.92E+03 2.31E+02 6.33E 01 20 0.92 0.15 4.28 9.50E-10 1.14E-08 3.09E 07 1.30E 10 6.78E+01 6.67E+02 6.70E+01 1.41E 01 20 1.38 0.01 0.02 7.80E 11 9.38E 10 2.53E 08 1.06E 11 2.39E+01 7.31E+01 2.39E+01 1.16E-02 20 10.0 0.00 0.24 0.44 1.25E-09 2.29E 08 4.21E 07 1.61E-10 8.29E+01 1.32E+03 1.11E+02 2.73E 01 20 0.50 0.15 0.27 7.59E 10 1.39E 08 2.55E-07 9.79E-11 5.82E+01 8.06E+02 7.52E+01 1.66E 01 20 0.99 0.03 0.06 1.69E-10 3.10E-09 5.69E-08 2.19E 11 2.85E+01 1.95E+02 3.23E+01 3.70E-02 20 1.49' O.00 0.00 1.39E 11 2.54E 10 4.67E 09 1.79E 12 2.07E+01 3.44E+01 2.10E+01 3.03E 03 20 1

1995 Graded Exercise

--er

+-

w

-e-e m

w

I StEto of Taxas 1995 Graded Exercise 06-December-1995 REAL TIME:

11:30 RELATIVE TIME:

H+04:30 OFFSITE RADIOLOGICAL SURVEY DATA


METEOROLOGICAL DATA---------- ------------RELEASE DATA---------------

WIND SPEED (MPH) 8.00 NOBLE GAS (CI/SEC) 3.885E+01 DELTA-T (DEG. F/50M)

-0.90 IODINE (CI/SEC) 3.288E-01 STABILITY CLASS (PASQUILL)

D PARTICULATE (CI/SEC) 7.670E-01 WIND DIRECTION (DEGREES) 233.0 TOTAL (CI/SEC) 3.994E+01 l

PLUME TRAVEL (MI) 1.728E+01 AVERAGE GAMMA (MEV/ DIS)

~

0.45 l

PLUME TRAILING EDGE (MI) 0.000E+00 AVERAGE BETA (MEV/ DIS) 0.27 1995 Graded Exercise LOCATION l

DOSE RATE l

AIR CONCENTRATION l AIR SAMPLE CPM l GROUND DEPOS! TION l 8ACKGROUN l

DOWN DIST.

CLOSED OPEN GROSS GROSS NOBLE 10 DINE GROSS GROSS GROSS NET 8ACKGROUN WIND OFF W1190W WINDOW 10 DINE PART.

GAS 131 IG)lNE PART.

DEPOSIT.

GROUND COUNT i

DIST CENT.

DOSE R.

DOSE R.

ACTIVITY ACTIVITY ACTIVITY ACTIVITY COUNT R.

COUNT R.

COUNT R.

DEPOSIT.

RATE l

(MI)

(MI)

(MR/NR)

(MR/NR) (UCI/CC)

(UCI/CC)

(UCI/CC)

(UCI/CC)

(CPM)

(CPM)

TCPM)

(UCI/M2)

(CPM) 0.5 0.00 286.86 667.88 8.06E 06 1.88E-05 9.89E-04 1.40E-06 4.05E+05 1.06E+06 2.48E+05 7.45E+02 20 0.04 173.99 405.09 4.89E-06 1.14E-05 6.00E 04 8.50E 07 2.46E+05 6.46E+05 1.51E+05 4.52E+02 20 O.08 38.82 90.39 1.09E-06 2.55E 06 1.34E 04 1.90E 07 5.49E+04 1.44E+05 3.36E+04 1.01E+02 20 1

0.12 3.19 7.42 8.95E 06 2.09E-07 1.10E-05 1.56E-08 4.52E+03 1.18E+04 2.78E+03 8.28E+00 20 1.0 0.00 129.65 301.86 3.53E 06 8.25E-06 4.48E 04 6.14E-07 1.78E+05 4.67E+05 1.09E+05 3.27E+02 20 0.07 78.64 183.09 2.14E-06 5.01E 06 2.71E 04 3.73E-07 1.08E+05 2.83E+05 6.60E+04 1.98E+02 20 0.15 17.55 40.85 4.78E 07 1.12E 06 6.06E 05 8.32E-08 2.41E+04 6.32E+04 1.48E+04 4.42E+01 20 0.22 1.44 3.35 3.93E-08 9.17E-08 4.97E-06 6.83E 09 1.99E+03 5.21E+03 1.23E+03 3.63E+00 20 1.5 0.00 76.11 177.21 2.07E 06 4.84E-06 2.63E-04 3.61E-07 1.04E+05 2.74E+05 6.39E+04 1.92E+02 20 0.11 46.17 107.48 1.26E 06 2.94E 06 1.59E-04 2.19E 07 6.33E+04 1.66E+05 3.88E+04 1.16E+02 20 0.22 10.30 23.98 2.81E-07 6.55E 07 3.56E-05 4.88E 08 1.41E+04 3.71E+04 8.66E+03 2.60E+01 20 0.32 0.85 1.97 2.30E 08 5.38E 06 2.92E 06 4.01E-09 1.18E+03 3.06E+03 7.29E+02 2.13E+00 20

' 2.0 0.00 52.02 117.91 1.26E 06 3.22E 06 1.69E-04 2.12E-07 6.33E+04 1.82E+05 3.58E+04 1.07E+02 20 0.14 31.55 71.52 7.63E-07 1.95E-06 1.03E-04 1.28E-07 3.84E+04 1.10E+05 2.17E+04 6.51E+01 20 0.28 7.04 15.96 1.70E 07 4.35E-07 2.29E-05 2.86E-08 8.58E+03 2.46E+04 4.86E+03 1.45E+01 20 0.42 0.58 1.31 1.40E 08 3.57E 08 1.88E-06 2.35E 09 7.23E+02 2.04E+03 4.17E+02 1.19E+00 20 i

(

3.0 0.00 30.14 68.33 7.41E-07 1.89E 06 9.80E 05 1.25E-07 3.73E+04 1.07E+05 2.11E+04 6.32E+01 20 0.20 18.28 41.44 4.49E 07 1.15E-06 5.94E 05 7.56E-06 2.26E+04 6.50E+04 1.28E+04 3.83E+01 20 0.39 4.08 9.25 1.00E 07 2.56E-07 1.33E 05 1.69E-08 5.06E+03 1.45E+04 2.87E+03 8.55E+00 20 0.59 0.33 0.76 8.23E 09 2.10E 08 1.09E-06 1.38E 09 4.34E+02 1.21E+03 2.54E+02 7.02E 01 20 4.0 0.00 20.15 44.38 4.45E 07 1.26E-06 6.14E 05 7.23E-06 2.24E+04 7.11E+04 1.15E+04 3.45E+01 20 0.25 12.22 26.92 2.70E-07 7.62E-07 3.72E-05 4.39E 08 1.36E+04 4.31E+04 6.99E+03 2.09E+01 20 0.50 2.73 6.01 6.03E 08 1.70E 07 8.31E-06 9.79E 09 3.05E+03 9.64E+03 1.58E+03 4.67E+00 20 0.75 0.22 0.49 4.95E 09 1.40E-08 6.82E 07 8.04E-10 2.69E+02 8.10E+0i 1.4M+02 3.84E-01 20 i

1 I

. State of Tcxas t

,1995 Graded Exercise 06-December-1995 REAL TIME:

11:30 RELATIVE TIME:

H+04:30 LOCATION l

DOSE RATE l

AIR CONCENTRATION l AIR SAMPLE CPM l GROLAS DEPOSITION l a m an0UN {

.................................................................................................................................... l f

DOWN DIST.

CLOSE0 GPEN GR088 GROSS NOBLE ItBINE GROSS GROSS GROSS NET 8ACKGRCERI WIND OFF WINDOW WINDOW IGDINE PART.

GAS 131 ICDINE Pt.T.

DEPOSIT.

GROUND COUNT DIST CENT.

DOSE R.

DOSE R.

ACTIVITY ACTIVITY ACTIVITY ACTIVITY COUNT R.

COUNT R.

COUNT R.

DEPOSIT.

RATE (MI) (MI)

(NR/NR) (NR/NR) (UCI/CC)

(UCI/CC)

(UCI/CC) (UCI/CC)

(CPN)

(CPN)

(CPM).

(UCI/N2)

(CPN) 5.0 0.00 14.00 29.87 2.75E 07 8.63E 07 3.96E 05 4.30E 08 1.39E+04 4.88E+04 6.35E+03 1.90E+01 20 O.30 8.49 18.12 1.67E 07 5.23E 07 2.40E 05 2.61E 08 8.42E+03 2.9aE+04 3.86E+03 1.15E+01 20 0.60 1.89 4.04 3.72E 08 1.17E-07 5.36E 06 5.82E 09 1.89E+03 6.63E+03 8.T7E+02 2.57E+00 20 0.89 0.16 0.33 3.06E 09 9.59E-09 4.40E 07 4.78E 10 1.74E+02 5.62E+02 9.06E+01 2.11E-01 20 i

i 6.0 0.00 11.10 23.69 2.21E 07 6.94E 07 3.14E-05 3.46E 08 1.12E+04 3.93E+04 5.12E+03 1.53E+01 20 O.34 6.73 14.37 1.34E 07 4.21E-07 1.91E 05 2.10E 08 6.78E+03 2.38E+04 3.11E+03 9.28E+00 20 F

0.69 1.50 3.21 3.00E 08 9.39E 08 4.25E-06 4.68E-09 1.53E+03 5.34E+03 7.10E+02 2.07E+00 20 l

1.03 0.12 0.26 2.46E 09 7.71E 09 3.49E-07 3.84E 10 1.44E+02 4.56E+02 7.66E+01 1.70E 01 20 7.0 0.00 7.59 15.65 1.30E 07 4.63E-07 1.98E 05 1.95E-08 6.56E+03 2.62E+04 2.69E+03 8.03E+00 20 j

0.38 4.61 9.49 7.89E 06 2.81E 07 1.20E 05 1.18E 06 3.99E+03

.1.59E+04 1.64E+03 4.87E+00 20 l

0.77 1.03 2.12 1.76E 08 6.26E-08 2.67E 06 2.64E 09 9.05E+02 3.56E+03 3.82E+02 1.09E+00 20 1.15 0.08 0.17 1.44E 09 5.14E 09 2.19E 07 2.17E 10 9.27E+01 5.11E+02 4.97E+01' 8.92E 02 20

.l 8.0 0.00 6.44 13.28 1.12E 07 3.97E-07 1.68E 05 1.67E 08 5.64E+03 2.25E+04 2.32E+03 70E+00 20

'5 0.42 3.91 8.05 6.77E 06 2.41E 07 1.02E-05,. 1.01E 08 3.43E+03 1.37E+04 1.41E+03 4.18E+00 20 l

0.85 0.87 1.80 1.51E 08 5.37E-08 2.27E 06 2.26E-09 7.80E+02 3.06E+03 3.31E+02 9.33E-01 20 1.27 0.07 0.15 1.24E 09 4.41E 09 1.86E-07 1.86E-10 8.24E+01 2.70E+02 4.55E+01 7.66E 02 20 9.0 0.00 3.34 6.63 4.20E 06 2.11E-07 7.85E 06 6.01E-09 2.13E+03 1.20E+04 9.94E+02 2.92E'00 20

+

0.46 2.03 4.02 2.54E 08 1.28E 07 4.76E-06 3.64E-09 1.30E+03 7.26E+03 6.10E+02 1.77E+00 20 0.92 0.45 0.90 5.68E 09 2.86E 08 1.06E 06 8.13E-10 3.06E+02 1.64E+03 1.52E+02 3.96E-01 20 1.38 0.04 0.07 4.66E 10 2.34E-09 e.73E 08 6.67E 11 4.34E+01 1.53E+02 3.00E+01 3.25E-02 20 l

i 10.0 0.00 0.97 1.84 6.03E 09 7.25E 08 2.00E 06 8.21E-10 3.23E+02 4.12E+03 3.11E+02 8.74E-01 20 l

0.50 0.59 1.12 3.66E 09 4.40E-08 1.21E 06 4.98E 10 2.04E+02 2.51E+03 1.97E+02 5.30E 01 20 j

0.99 0.13 0.25 8.16E 10 9.82E C7 2.71E 07 1.11E 10 6.10E+01 5.75E+02 5.94E+01 1.18E 01 c0 l

1.49 0.01 0.02 6.70E 11 8.06E 10 2.22E-08 9.13E 12 2.34E+01 6.56E+01 2.32E+01 9.71E 03

't0 I

)

1995 Graded Exercise i

}

l I

Steta of Tcxa3 1995 Graded Exercise 06-December-1995 REAL TIME:

11:45 RE H+04:45 eooo************************************************LATIVE TIME:

OFFSITE RADIOLOGICAL SURVEY DA oooo*************************************************TA


METEOROLOGICAL DATA----------


RELEASE DATA---------------

WIND SPEED (MPH) 8.00 NOBLE GAS (CI/SEC) 3.993E+01 DELTA-T (DEG. F/50M)

-0.90 IODINE (CI/SEC) 3.367E-01 STABILITY CLASS (PASQUILL)

D PARTICULATE (CI/SEC) 7.249E-01 WIND DIRECTION (DEGREES) 235.0 TOTAL (CI/SEC) 4.099E+01 PLUME TRAVEL (MI) 1.929E+01 AVERAGE GAMMA (MEV/ DIS) 0.43 PLUME TRAILING EDGE (Pil) 0.000E+00 AVERAGE BETA (MEV/ DIS) 0.26 1995 Graded Exercise LOCATION l

DOSE RATE l

A!R CONCENTRATION l AIR SAMPLE CPM l GROUND DEPOSITION BACKGROUN

.........................................................................................................................l...........

DOWN DIST.

CLOSED OPEN GROSS GROSS NOBLE IG)INE GROSS GROSS GROSS NET BACKGROUN WIND OFF WINDOW WINDOW IODINE PART.

GAS 131 IODINE PART.

DEPOSIT.

GROUNO COUNT DIST CENT.

DOSE R.

DOSE R.

ACTIVITY ACTIVITY ACTIVITY ACTI'L G COUNT R.

COUNT R.

COUNT R.

DEPOSIT.

RATE (MI)

(MI)

(MR/NR) (MR/NR) (UCI/CC)

(UC1/CC) (UCI/CC) 0FAC)

(CPM)

(CPM)

(CPM)

(UCI/M2)

(CPM) 0.5 0.00 278.39 664.59 8.25E-06 1.78E 05 1.02E 03 1.48E 06 4.15E+05 1.01E+06 2.64E+05 7.93E+02 20 0.04 168.85 403.09 5.COE 06 1.00E 05 6.17E-04 8.97E-07 2.52E+05 6.10E+05 1.60E+05 4.81E+02 20 0.08 37.68 89.94 1.12E-06 2.41E-06 1.38E-04 2.00E 07 5.62E+04 1.36E+05 3.58E+04 1.07E+02 20 0.12 3.09 7.38 9.17E 08 1.90E 07 1.13E 05 1.64E 08 4.63E+03 1.12E+04 2.95E+03 8.81E+00 20 1.0 0.00 125.83 300.39 3.62E 06 7.80E-06 4.60E 04 6.49E 07 1.82E+05 4.41E+05 1.16E+05 3.48E+02 20 O.07 76.32 182.19 2.20E 06 4.73E-06 2.79E-04 3.93E 07 1.10E+05 2.6BE+05 7.03E+04 2.11E+02 20 0.15 17.03 40.65 4.90E 07 1.06E 06 6.23E-05 8.78E 08 2.47E+04 5.97E+04 1.57E+04 4.71E+01 20 l

0.22 1.40 3.34 4.02E-08 8.66E 08 5.11E 06 7.21E 09 2.04E+03 4.92E+03 1.31E+03 3.86E+00 20 1.5 0.00 73.87 176.34 2.12E-06 4.58E' 06 2.70E-04 3.81E 07 1.07E+05 2.59E+05 6.80E+04 2.04E+02 20 0.11 44.80 106.%

1.29E 06 2.78E 06 1.64E 04 2.31E 07 6.48E+04 1.57E+05 4.12E+04 1.24E+02 20 0.22 10.00 23.87 2.87E-07 6.19E 07 3.65E 05 5.15E-08 1.45E+04 3.51E+04 9.22E+03 2.76E+01 20 0.32 0.82 1.96 2.36E 08 5.08E-08 3.00E-06 4.23E-09 1.21E+03 2.90E+03 7.75E+02 2.27E+00 20 2.0 0.00 51.39 119.66 1.32E-06 3.08E 06 1.78E-04 2.29E 07 6.63E+04 1.74E+05 3.93E+04 1.18E+02 20 0.14 31.17 72.57 8.00E 07 1.87E 06 1.08E 04 1.39E-07 4.02E+04 1.06E+05 2.38E+04 7.15E+01 20 0.28 6.96 16.19 1.78E-07 4.17E-07 2.40E-05 3.10E 08 8.99E+03 2.36E+04 5.33E+03 1.60E+01 20 0.42 0.57 1.33 1.46E-08 3.42E-08 1.97E 06 2.55E-09 7.57E+02 1.96E+03 4.56E+02 1.31E+00 20 3.0 0.00 29.78 69.33 7.76E-07 1.81E 06 1.03E-04 1'.35E 07 3.91E+04 1.03E+05 2.31E+04 6.94E+01 20 0.20 18.06 42.05 4.71E 07 1.10E-06 6.24E-05 8.19E-08 2.37E+04 6.23E+04 1.40E+04 4.21E+01 20 0.39 4.03 9.38 1.05E 07 2.46E-07 1.39E-05 1.83E-08 5.30E+03 1.39E+04 3.15E+03 9.40E+00 20 0.59 0.33 0.77 8.62E 09 2.02E 08 1.14E 06 1.50E-09 4.54E+02 1.16E+03 2.77E+02 7.71E 01 20 4.0 0.00 20.51 46.49 4.85E 07 1.24E-06 6.67E-05 8.17E-08 2.44E+04 7.03E+04 1.34E+04 4.00E+01 20 0,25 12.44 28.20 2.94E-07 7.53E 07 4.05E 05 4.95E 08 1.48E+04 4.26E+04 8.11E+03 2.43E*01 20 0.50 2.78 6.29 6.57E 08 1.68E 07 9.03E-06 1.11E-08 3.32E+03 9.53E+03 1.82E+03 5.42E+00 20 0.75 0.23 0.52 5.39E-09 1.38E 08 7.41E 07 9.07E-10 2.91E+02 8.01E+02 1.68E+02 4.45E-01 20

~l l

l i

Stcta of Tcxa3 1995 Graded Exercise 06-December-1995 REAL TIME:

11:45 RELATIVE TIME:

H+04:45 LOCATION l

DOSE R7TE l

AIR CONCENTRATION l AIR SAMPLE CPM l GROUND DEPOSITION l BACKGROUN 1

DOWN DIST.

CLOSED OPEN GROSS.

GROSS NOBLE 10 DINE GROSS GROSS GROSS NET BACKGROUN WIND OFF WINDOW WINDOW IODINE PART.

GAS 131 ICDINE PART.

DEPOSIT.

GROUND COUNT DIST CENT.

DOSE R.

DOSE R.

ACTIVITY ACTIVITY ACTIVITY ACTIVITY COUNT R.

COUNT R.

COUNT R.

DEPOSIT.

RATE i

(%!)

(MI)

(MR/NR) (MR/NR) (UCI/CC)

(UCl/CC) (UCI/CC)

(UCI/CC)

(CPM)

(CPM)

(CPM)

(UCI/M2)

(CPM) 5.0 0.00 15.02 33.09 3.22E-07 9.09E-07 4.58E 05 5.23E 08 1.62E+04 5.14E+04 8.07E+03 2.42E+01 20 0.30 9.11 20.07 1.95E 07 5.51E 07 2.78E-05 3.17E-08 9.84E+03 3.12E+04 4.90E+03 1.47E+01 20 0.60 2.03 4.48 4.36E 08 1.23E-07 6.20E 06 7.07E-09 2.21E+03 6.98E+03 1.11E+03 3.27E+00 20 0.89 0.17 0.37 3.58E 09 1.01E 08 5.09E-07 5.81E-10 2.00E+02 5.91E+02 1.09E+02 2.69E 01 20 6.0 0.00 11.91 26.23 2.59E-07 7.31E 07 3.63E-05 4.20E 08 1.30E+04 4.14E+04 6.50E+03 1.95E+01 20 i

0.34 7.23 15.91 1.57E 07 4.43E 07 2.20E 05 2.55E 08 7.92E+03 2.51E+04 3.95E+03 1.18E+01 20 0.69 1.61 3.55 3.50E-08 9.89E-08 4.91E-06 5.69E 09 1.78E+03 5.62E+03 8.97E+02 2.63E+00 20 1.03 0.13 0.29 2.88E 09 8.12E 09 4.03E 07 4.67E 10 1.65E+02 4.80E+02 9.20E+01 2.16E 01 20 I

l 7.0 0.00 9.11 19.45 1.77E-07 5.55E-07 2.5SE-05 2.77E-08 8.92E+03 3.14E+04 4.00E+03 1.20E+01 20 O.38 5.53 11.79 1.07E 07 3.37E 07 1.57E-05 1.68E 08 5.42E+03 1.91E+04 2.43E+03 7.25E+00 20 0.77 1.23 2.63 2.39E-08 7.51E-08 3.49E 06 3.74E-09 1.22E+03 4.27E+03 5.59E42 1.62E+00 20 1.15 0.10 0.22 1.97E-09 6.17E 09 2.87E-07 3.07E-10 1.19E+02 3.69E+02 6.42E+01' 1.33E 01 N

8.0 0.00 7.73 16.49 1.52E-07 4.77E-07 2.19E-05 2.37E-08 7.66E+03 2.70E+04 3.44E+03 1.03E+01 20 0.42 4.69 10.00 9.21E 08 2.89E-07 1.33E 05 1.44E 08 4.65E+03 1.64E+04 2.09E+03 6.22E+00 20 1

0.85 1.05 2.23 2.06E 08 6.45E-08 2.96E 06 3.21E 09 1.05E+03 3.67E+03 4.83E+02 1.39E+00 20 1.27 0.09 0.18-1.69E-09 5.30E-00 2.43E-07 2.64E 10 1.05E+02 3.20E+02 5.80E+01 1.14E-01 20 9.0 0.00 5.56 11.45 9.41E 08 3.35E-07 1.45E-05 1.41E 08 4.75E+03 1.90E+04 1.93E+03 5.74E+00 20 0.46 3.37 6.95 5.70E 06 2.03E 07 8.77E 06 8.55E 09 2.89E+03 1.15E+04 1.18E+03 3.48E+00 20 0.92 0.75 1.55 1.27E-08 4.53E 08 1.96E 06 1.91E-09 6.60E+02 2.58E+03 2.79E+02 7.76E-01 20 1.38 0.06 0.13 1.04E-09 3.72E-09 1.61E 07 1.57E 10 7.26E+01 2.30E+02 4.12E+01 6.37E-0 20 10.0 0.00 2.93 5.82 3.60E-08 1.81E-07 6.89E 06 5.16E-09 1.83E+03 1.03E+04 8.49E+02 2.49E+00 20 0.50 1.78 3.53 2.18E 08 1.10E 07 4.18E-06 3.13E 09 1.12E+03-6.24E+03 5.23E+02 1.51E+00 20 0.99 0.40 0.79 4.87E-09 2.45E 08 9.33E 07 6.98E 10 2.65E+02 1.41E+03 1.32E+02 3.37E-01 20 1.49 0.03 0.06 4.00E 10 2.01E-09 7.66E-08 5.73E-11 4.01E+01 1.34E+02 2.92E+01 2.77E-02 20 1995 Graded Exercise 1

i l

Ctoto of Tcxac 1995 Graded Exercise 06-December-1995 REAL TIME:

12:00 RELATIVE TIME:

H+05:00 eeee****************************************************************************

OFFSITE RADIOLOGICAL SURVEY DATA oe******************************************************************************


METEOROLOGICAL DATA---------- ------------RELEASE DATA---------------

WIND SPEED (MPH) 8.00 NOBLE GAS (CI/SEC) 4.048E+01 DELTA-T (DEG. F/50M)

-0.90 IODINE (CI/SEC) 3.398E-01 STABILITY CLASS (PASQUILL)

D PARTICULATE (CI/SEC) 6.8'15E-01 WIND DIRECTION (DEGREES) 235.0 TOTAL (CI/SEC) 4.150E+01 PLUME TRAVEL (MI) 2.129E+01 AVERAGE GAMMA (MEV/ DIS) 0.41 PLUME TRAILING EDGE (MI) 0.000E+00 AVERAGE BETA (MEV/ DIS) 0.25 1995 Graded Exercise LOCATION l

DOSE RATE l

AIR CONCENTRATION l AIR SAMPLE CPM l GROUND DEPOSITION l BACKGROUN DOWN DIST.

CLOSE0 OPEN GROSS GROSS NOSLE Im)INE GROSS GROSS GROSS NET BACKGROUN WIND OFF WINDOW WINDOW IG)!NE PART.

GAS 131 10 DINE PART.

' DEPOSIT.

GROUND CGJNT DIST CENT.

DOSE R.

DOSE R.

ACTIVITY ACTIVITY ACTIVITY ACTIVITY COUNT R.

COUNT R.

COUNT R.

DEPOSIT.

RATE (MI)

(MI)

(MR/NR) (MR/NR) (UCI/CC)

(UCI/CC) (UCI/CC) (UCI/CC)

(CPM)

(CPM)

(CPM)

(UCI/M2)

(CPM) 0.5 0.00 267.18 653.05 8.33E 06 1.67E 05 1.03E 03 1.54E 06 4.19E+05 9.46E+05 2.78E+05 8.35E+02 20 0.04 162.06 396.10 5.0$E-06 1.01E 05 6.25E-04 9.31E*07 2.54E+05 5.74E+05 1.69E+05 5.06E+02 20 0.08 36.16 88.38 1.13E 06 2.26E 06 1.40E 04, 2.08E 07 5.67E+04 1.28E+05 3.76E+04 1.13E+02 20 0.12 2.97 7.25 9.25E 08 1.86E 07 1.15E 05 1.71E-08 4.67E+03 1.05E+04 3.11E+03 9.27E+00 20 1.0 0.00 120.77 295.18 3.65E 06 7.33E 06 4.66E 04 6.73E-07 1.84E+05 4.15E+05 1.22E+05 3.66E+02 20 0.07 73.25 179.04 2.22E 06 4.45E 06 2.83E 04 4.08E 07 1.11E+05 2.52E+05 7.40E+04 2.22E+02 20 0.15 16.34 39.95 4.94E 07 9.92E 07 6.31E-05 9.11E 06 2.49E+04 5.62E+04 1.65E+04 4.96E+01 20 0.22 1.34 3.28 4.06E 08 8.15E-08 5.18E 06 7.48E 09 2.06E+03 4.63E+03 1.37E+03 4.07E+00 20 1.5 0.00 70.90 173.29 2.14E 06 4.30E 06 2.74E-04 3.95E-07 1.08E+05 2.43E+05 7.16E+04 2.15E+02 20 0.11 43.00 105.11 1.30E 06 2.61E-06 1.66E 04 2.40E 07 6.54E+04 1.48E+05 4.34E+04 1.30E+02 20 0.22 9.60 23.45 2.90E 07 5.82E 07 3.70E 05 5.35E-08 1.46E+04 3.30E+04 9.70E+03 2.91E+01 20 0.32 0.79 1.93 2.38E 08 4.78E 08 3.04E 06 4.39E-09 1.22E+03 2.72E+03 8.15E+02 2.39E+00 20 2.0 0.00 49.88 119.08 1.35E 06 2.91E-06 1.83E 04 2.42E-07 6.79E+04 1.65E+05 4.22E+04 1.27E+02 20 0.14 30.26 72.23 8.19E 1.77E-06 1.11E 04 1.47E-07 4.12E+04 1.00E+05 2.56E+04 7.68E+01 20 0.28 6.75 16.12 1.83E-07 3.94E 07 2.47E-05 3.28E-06 9.21E+03 2.23E+04 5.73E+03 1.71E+01 20 0.42 0.55 1.32 1.50E 08 3.24E-08 2.03E-06 2.69E-09 7.74E+02 1.85E+03 4.88E+02 1.41E+00 20 3.0 0.00 28.90 69.00 7.95E-07 1.71E-06 1.06E-04 1.42E-07 4.00E+04 9.70E+04 2.48E+04 7.46E+01 20 0.20 17.53 41.85 4.82E-07 1.04E 06 6.42E-05 8.64E 08

  • 2.43E+04 5.89E+04 1.51E+04 4.52E+01 20 0.39 3.91 9.34 1.08E 07 2.32E 07 1.43E 05 1.93E 08 5.43E+03 1.32E+04 3.38E+03 1.01E+01 20 0.59 0.32 0.77 8.83E 09 1.90E-08 1.17E-06 1.58E-09 4.64E+02 1.10E+03 2.96E+02 8.28E 01 20 4.0 0.00 20.26 47.18 5.09E 07 1.19E-06 7.01E 05 8.84E-08 2.56E+04 6.73E+04 1.48E+04 4.44E+01 20 0.25 12.29 28.61 3.09E-07 7.22E 07 4.25E 05 5.36E-08 1.55E+04 4.09E+04 8.99E+03 2.69E+01 20 0.50 2.74 6.38 6.88E 08 1.61E-07 9.48E 06 1.20E 3.48E+03 9.13E+03 2.02E+03 6.01E+00 20

~

0.75 0.23 0.52 5.65E 09 1.32E 08 7.79E 07 9.82E-10 3.04E+02 7.68E+02 1.84E+02 4.93E-01 20

State of Taxac 1995 Graded Exercise 06-December-1995 REAL TIME:

12:00 RELATIVE TIME:

H+05:00 LOCATION l

DOSE RATE l

AIR CONCENTRAT10N l AIR SAMPLE CPN l GROUND DEPOSITION l m a ne n I

DOWN DIST.

CLOSED OPEN GROSS GROSS NOBLE 10 DINE GROSS GROSS GROSS NET OACKGROUN 1 WIND OFF WINDOW WINDOW 10 DINE PART.

GAS 131 10 DINE PART.

DEPOSIT.

GROUND COUNT 018T CENT.

DOSE R.

DOSE R.

ACTIVITY ACTIVITY ACTIVITY ACTIVITY COUNT R.

COUNT R.

COUNT R.

DEP0EIT.

RATE (MI)

(MI)

(NR/NR)

(NR/NR) (UCI/CC)

(UCI/CC)

(UCI/CC) (UCI/CC)

(CPN)

(CPN)

(CPM)

(UCI/N2)

(CPN) 1 l

5.0 0.00 15.29 34.66 3.51E 07 8.98E 07 4.98E-05 5.90E 08 1.77E+04 5.08E+04 9.45E+03 2.83E+01 20 0.30 9.27 21.02 2.13E 07 5.45E 07 3.02E 05 3.58E-08 1.07E+04 3.08E+04 5.74E+03 1.72E+01 20 0.60 2.07 4.69 4.75E 08 1.22E 07 6.74E 06 7.98E-09 2.41E+03 6.90E+03 1.30E+03 3.83E+00 20 l

0.89 0.17 0.38 3.90E 09 9.98E-09 5.53E 07 6.55E 10 2.16E+02 5.84E+02 1.25E+02 3.15E-01 20 6.0 0.00 12.12 27.48 2.82E 07 7.22E 07 3.95f 05 4.75E-08 1.42E+04 4.09E+04 7.61E+03 2.28E+01 20 O.34 7.35 16.67 1.71E 07 4.38E 07 2.39E 05 2.88E 08 8.63E+03 2.48E+04 4.62E+03 1.38E+01 20 0.69 1.64 3.72 3.82E 08 9.78E-08 5.34E 06 6.42E-09 1.94E+03 5.55E+03 1.05E+03 3.00E+00 20 1.03 0.13 0.31 3.1M 09 8.0M-09 4.38E 07 5.27E 10 1.78E+02 4.74E+02 1.04E+02 2.5M 01 20 7.0 0.00

'9.78 21.54 2.07E 07 5.85E-07 2.98E 05 3.36E-08 1.04E+04 3.31E+04 5.12E+03 1.53E+01 20 0.38 5.93 13.06 1.26E 07 3.55E 07 1.81E 05 2.04E 08 6.33E+03 2.01E+04 3.11E+03 9.29E+00 20 0.77 1.32 2.91 2.80E 08 7.91E 08 4.04E 06 4.55E 09 1.43E+03 4.50E+03 7.10E+02 2.07E+00 20 1.15 0.11 0.24 2.30E-09 6.50E 09 3.31E-07 3.73E-10 1.36E+02 3.88E+02 7.67E+01' 1.70E-01 20 8.0 0.00 8.29 18.27 1.7BE-07 5.02E-07 2.53E-05 2.88E-08 8.95E+03 2.84E+04 4.40E+03 1.31E+01 20 0.42 5.03 11.08 1.08E-07 3.04E-07 1.53E 05 1.75E 08 5.44E+03 1.72E+04 2.68E+03 7.97E+00 20 0.85 1.12 2.47 2.40E 08 6.79E-06 3.42E-06 3.90E 09 1.23E+03 3.86E+03 6.12E+02 1.78E+00 20 1.27 0.09 0.20 1.97E-09 5.58E-09 2.81E 07 3.20E 10 1.19E+02 3.36E+02 6.86E+01 1.46E 01 20 9.0 0.00 6.67 14.23 1.28E 07 4.02E-07 1.89E-05 2.00E 08 6.46E+03 2.28E+04 2.88E+03 8.57E+00 20 0.46 4.04 8.63 7.76E 06 2.44E 07 1.15E 05 1.21E 08 3.92E+03 1.38E+04 1.75E+03 5.20E+00 20 0.92 0.90 1.93 1.73E 08 5.44E-08 2.56E 06 2.71E 09 8.91E+02 3.10E+03 4.06E+02 1.16E+00 20 1.38 0.07 0.16 1.42E 09 4.46E 09 2.10E 07 2.22E 10 9.15E+01 2.73E+02 5.17E+01 9.53E 02 20 10.0 0.00 4.87 10.05 8.07E 06 2.88E-07 1.27E 05 1.21E-08 4.00E+03 1.63E+04 1.65E+03 4.90E+00 20 l

0.50 2.%

6.09 4.90E-08 1.74E-07 7.70E-06 7.34E 09 2.48E+03 9.89E+03 1.01E+03 2.97E+00 20 0.99 0.66 1.36 1.09E-06 3.89E-08 1.72E 06 1.64E 09 5.69E+02 2.22E+03 2.41E+02 6.63E 01 20 1.49' O.05 0.11 8.97E-10 3.20E 09 1.41E 07 1.34E 10 6.51E+01 2.01E+02 3.81E+01 5.44E-02 20 1995 Graded Exercise l

i

State of Taxas 1995 Graded Exercise 06-December-1995 REAL TIME:

12:15 RELATIVE TIME:

H+05:15 e*eee******************************************************+********************

OFFSITE RADIOLOGICAL SURVEY DATA


METEOROLOGICAL DATA----------


RELEASE DATA---------------

WIND SPEED (MPH) 8.00 NOBLE GAS (CI/SEC) 4.966E+01 DELTA-T (DEG. F/50M)

-1.00 IODINE (CI/SEC) 3.397E-01 STABILITY CLASS (PASQUILL)

D PARTICULATE (CI/SEC) 6.399E-01 WIND DIRECTION (DEGREES) 235.0 TOTAL (CI/SEC) 4.164E+01 PLUME TRAVEL (MI) 2.330E+01 AVERAGE GAMMA (MEV/ DIS) 0.40 PLUME TRAILING EDGE (MI) 0.000E+00 AVERAGE BETA (MEV/ DIS) 0.25 1995 Graded Exercise LOCATION l

DOSE RATE l

A!it CONCENTRATION l AIR SAMPLE CPM l GROUND DEPOSITION l SACKGROUN DOWN D!$T.

CLOSED OPEN GROSS GROSS N08LE ICDINE GROSS GROSS GROSS NET SACKGROUN WIND OFF WINDOW WINDOW

!(BINE PART.

GAS 131 1(DINE PART.

DEPOSIT.

GROUND COUNT DIST CENT.

DOSE R.

DOSE R.

ACTIVITY ACTIVITY ACTIVITY ACTIVITY C(11NT R.

COUNT R.

COUNT R.

DEPOSIT.

RATE (MI)

(MI)

(MR/NR) (MR/NR) (UCl/CC) (UCI/CC) (UCI/CC)

(UC!/CC)

(CPM)

(CPM)

(CPM)

(UC!/M2)

- (CPM) 0.5 0.00 254.61 636.36 8.32E 06 1.57E-05 1.04E 03 1.58E 06 4.19E+05 8.88E+05 2.91E+05 8.74E+02 20 0.04 154.43 385.97 5.05E 06 9.52E 06 6.28E-04 9.56E 07 2.54E+05 5.39E+05 1.77E+05 5.30E+02 20 0.08 34.46 86.12 1.13E 06 2.12E 06 1.40E 04 2.13E-07 5.67E+04 1.20E+05 3.94E+04 1.18E+02 20 0.12 2.83 7.07 9.25E-08 1.74E-07 1.15E 05 1.75E 08 4.67E+03 9.89E+03 3.25E+03 9.71E+00 20 1.0 0.00 115.09 287.65 3.65E 06 6.89E 06 4.68E 04 6.91E 07 1.84E+05 3.90E+05 1.28E+05 3.83E+02 20 0.07 69.81 174.47 2.21E-06 4.18E 06 2.84E 04 4.19E-07 1.11E+05 2.36E+05 7.74E+04 2.32E+02 20 0.15 15.58 38.93 4.94E 07 9.32E 07 6.34E-05 9.36E 08 2.49E+04 5.27E+04 1.73E+04 5.19E+01 20 0.22 1.28 3.20 4.06E 08 7.65E 08 5.20E-06 7.68E-09 2.06E+03 4.35E+03 1.44E+03 4.26E+00 20 4

1.5 0.00 67.56 168.87 2.14E-06 4.04E 06 2.75E-04 4.06E-07 1.08E+05 2.29E+05 7.49E+04 2.25E+02 20 0.11 40.98 102.42 1.30E-06 2.45E 06 1.67E-04 2.46E-07 6.54E+04 1.39E+05 4.54E+04 1.36E+02 20

'O.22 9.14 22.85 2.90E 07 5.47E-07 3.72E-05 5.49E 08 1.46E+04 3.10E+04 1.02E+04 3.04E+01 20 0.32 0.75 1.88 2.38E 08 4.49E 08 3.05E 06 4.51E-09 1.22E+03 2.56E+03 8.52E+02 2.50E+00 20 2.0 0.00 47.88 117.03' 1.36E 06 2.74E 06 1.85E 04 2.51E-07 6.86E+04 1.55E+05 4.47E+04 1.34E+02 20 0.14 29.04 70.98 8.26E 07 1.66E 06 1.12E-04 1.52E 07 4.16E+04 9.40E+04 2.71E+04 8.14E+01 20 0.28 6.48 15.84 1.84E-07 3.71E-07 2.51E-05 3.40E-08 9.29E+03 2.10E+04 6.07E+03 1.82E+01 20 0.42 0.53 1.30 1.51E-08 3.04E-08 2.06E-06 2.79E 09 7.81E+02 1.74E+03 5.16E+02 1.49E+00 20 3.0 0.00 27.74 67.81 8.02E 07 1.61E-06 1.07E-04 1.48E-07 4.04E+04 9.12E+04 2.63E+04 7.90E+01 20 0.20 16.83 41.13 4.87E 07 9.78E-07 6.50E-05 8.97E-08 2.45E+04 5.53E+04 1.60E+04 4.79E+01 20 0.39 3.75 9.18 1.09E-07 2.18E-07 1.45E-05 2.00E 08 5.48E+03 1.24E+04 3.58E+03 1.07E+01 20 0.59 0.31 0.75 8.91E-09 1.79E-08 1.19E-06 1.64E-09 4.68E+02 1.03E+03 3.12E+02 8.78E 01 20 4.0 0.00 19.67 46.95 5.21E-07 1.12E-06 7.20E-05 9.34E-06 2.62E+04 6.37E+04 1.60E+04 4.80E+01 20 0.25 11.93 28.48 3.16E 07 6.82E 07 4.37E-05 5.6UE 08 1.59E+04 3.86E+04 9.71E+03 2.91E+01 20 0.50 2.66 6.35 7.05E 08 1.52E 07 9.75E-06 1.26E-06 3.57E+03 8.63E+03 2.18E+03 6.50E+00 20 0.75 0.22 0.52 5.79E-09 1.25E-08 8.00E-07 1.04E-09 3.11E+02 7.27E+02 1.98E+02 5.33E 01 20

Stcto of Tcxas 1995 Graded Exercise 06-December-1995 REAL TIME:

12:15 RELATIVE TIME:

H+05:15 LOCATION l

DOSE RATE l

AIR CONCENTRATION l AIR SAMPLE CPM l GROUND DEPOSITION l 8ACKGROUN DOWN DIST.

CLOSED OPEN GROSS GROSS NOBLE IODINE GROSS GROSS GROSS NET BACKGROUN WIND OFF WINDOW WINDOW IODINE PART.

GAS 131 10 DINE PART.

DFPOSIT.

GROUND COUNT -

DIST CENT.

DOSE R.

DOSE R.

ACTIVITY ACTIVITY ACTIVITY ACTIVITY COUNT R.

COUNT R.

COUNT R.

DEPOSIT.

RATE (MI) (MI)

(MR/NR) (MR/NR) (UCI/CC)

(UCI/CC)

(UCI/CC)

(UCI/CC)

(CPM)

(CPM)

(CPM)

(UCl/M2)

(CPM) 5.0 0.00 15.11 35.17 3.68E-07 8.61E 07 5.23E 05 6.39E-08 1.85E+04 4.87E+04 1.05E+04, 3.16E+01 20 0.30 9.16 21.33 2.23E 07 5.22E 07 3.17E 05 3.88E 08 1.12E+04 2.96E+04 6.40E+03 1.92E+01 20 0.60 2.04 4.76 4.97E 08 1.16E-07 7.08E-06 8.65E 09 2.52E+03 6.61E+03 1.44E+03 4.28E+00 20 0.89 0.17 0.39 4.08E-09 9.56E 09 5.81E-07 7.10E 10 2.25E+02 5.61E+02 1.37E+02 3.51E-01 20 6.0 0.00 11.98 27.89 2.96E 07 6.92E 07 4.14E-05 5.14E 08 1.49E+04 3.92E+04 8.48E+03 2.54E+01 20 0.34 7.26 16.91 1.79E-07 4.20E-07 2.51E-05 3.12E-08 9.04E+03 2.38E+04 5.15E+03 1.54E+01 20 0.69 1.62 3.77 4.00E-08 9.37E-08 5.61E-06 6.96E-09 2.03E+03 5.32E+03 1.17E+03 3.44E+00 20 1.03 0.13 0.31 3.28E 09 7.69E 09 4.60E 07 5.71E 10 1.85E+02 4.55E+02 1.14E+02 2.82E 01 20 7.0 0.00 9.95 22.56 2.25E 07 5.78E-07 3.24E 05 3.79E-08 1.14E+04 3.27E+04 6.02E+03 1.80E+01 20 0.38 6.04 13.68 1.37E-07 3.51E 07 1.97E 05 2.30E 08 6.90E+03 1.99E+04 3.66E+03 1.09E+01 20 0.77 1.35 3.05 3.05E 08 7.82E-08 4.39E 06 5.13E-09 1.55E+03 4.45E+03 8.31E+02 2.44E+00 20 1.15 0.11 0.25 2.50E-09 6.42E 09 3.60E-07 4.21E 10 1.46E+02 3.83E+02 8.66E+01 2.00E 01 20 8.0 0.00 8.44 19.13 1.94E-07 4.96E-07 2.75E-05 3.26E-08 9.75E+03 2.81E+04 5.17E+03 1.55E+01 20 0.42 5.12 11.60 1.17E-07 3.01E 07 1.67E-05 1.98E 08 5.92E+03 1.70E+04 3.14E+03 9.37E+00 20 0.85 1.14 2.59 2.62E 08 6.71E Da 3.72E 06 4.41E 09 1.34E+03 3.82E+03 7.17E+02 2.09E+00 20 1.27 0.09 0.21 2.15E 09 5.51E 09 3.05E-07 3.62E 10 1.28E+02 3.32E+02 7.72E+01 1.72E 01 20

9. ')

0.00 7.16 15.76 1.50E-07 4.23E 07 2.18E 05 2.43E-08 7.55E+03 2.40E+04 3.68E+03 1.10E'+01 20 0.46 4.34 9.56 9.08E 08 2.57E-07 1.12E-05 1.47E-08 4.58E+03 1.45E+04 2.24E+03 6.68E+00 20 0.92 0.97 2.13 2.02E 08 5.73E 08 2.95E-06 3.29E 09 1.04E+03 3.26E+03 5.16E+02 1.49E+00 20 1.38 0.08 0.18 1.66E 09 4.70E 09 2.4EE 07 2.70E-10 1.04E+02 2.86E+02 6.07E+01 1.22E-01 20 10.0 0.00 5.85 12.48 1.10E-07 3.45E 07 1.66E-05 1.72E-08 5.54E+03 1.96E+04 2.46E+03 7.33E+00 20 0.50 3.55 7.57 6.66E-08 2.09E 07 1.01E-05 1.04E 08 3.37E+03 1.19E+04 1.50E+03 4.45e+00 20 0.99 0.79 1.69 1.49E-08 4.67E-08 2.24E-06 2.32E 09 7.68E+02 2.66E+03 3.50E+02 9.92E-01 20 1.49 0.06 0.14 1.22E-09 3.84E-09 1.84E-07 1.91E-10 8.14E+01 2.37E+02 4.71E+01 8.14E-02 20 l

i 1995 Graded Exercise i

l i

I

Stcto of Taxa 3 1995 Graded Exercise 06-December-1995 REAL TIME:

12:30 RELATIVE TIME:

H+05:30 eecee***************************************************************************

OFFSITE RADIOLOGICAL SURVEY DATA ee*ee************************************************************************e**


METEOROLOGICAL DATA---------- ------------RELEASE DATA---------------

WIND SPEED (MPH) 9.00 NOBLE GAS (CI/SEC) 4.058E+01 DELTA-T (DEG. F/50M)

-1.00 IODINE (CI/SEC) 3.375E-01 STABILITY CLASS (PASQUILL)

D PARTICULATE (CI/SEC) 6.012E-01 WIND DIRECTION (DEGREES) 235.0 TOTAL (CI/SEC) 4.152E+01 PLUME TRAVEL (MI) 2.555E+01 AVERAGE GAMMA (MEV/ DIS) 0.38 PLUME TRAILING EDGE (MI) 0.000E+00 AVERAGE BETA (MEV/ DIS) 0.24 1995 Graded Exercise LOCATION l

DOSE RATE l

AIR CONCENTRATION l AIR SAMPLE CPM l GROUND DEPOSITION l BACKGROUN i

DOWN DIST.

CLOSED OPEN GROSS GROSS N0BLE IQDINE GROSS GROSS GROSS NET BACKGROUN WIND OFF WINDOW WINDOW ICDINE PART.

GAS 131 10 DINE PART.

DEPOSIT.

GROUIS COUNT DIST CENT.

DOSE R.

DOSE R.

ACTIVITY ACTIVITY ACTIVITY ACTIVITY COUNT R.

COUNT R.

COUNT R.

DEPOSIT.

RATE (MI)

(MI)

(MR/NR)

(MR/NR) (UCl/CC)

(UCl/CC) (UCl/CC) (UCl/CC)

(CPM)

(CPM)

(CPM)

(UCI/M2)

(CPM) 0.5 0.00 214.70 548.08 7.35E 06 1.31E 05 9.19E 04 1.43E 06 3.70E+05 7.42E+05 2.96E+05 8.89E+02 20 0.04 130.22 332.43 4.46E 06 7.95E 06 5.57E 04 8.66E 07 2.24E+05 4.50E+05 1.80E+05 5.39E+02 20 0.08 29.06 74.1 7 9.95E 07 1.77E 06 1.24E 04 1.93E-07 5.01E+04 1.00E+05 4.01E+04 1.20E+02 20 0.12 2.39 6.09 8.17E-08 1.46E 07 1.02E-05 1.59E-08 4.13E+03 8.26E+03 3.31E+03 9.88E+00 20 1.0 0.00 97.05 247.75 3.22E-06 5.75E 06 4.16E 04 6.26E-07 1.62E+05 3.25E+05 1.30E+05 3.90E+02 20 0.07 58.87 150.27 1.96E 06 3.49E 06 2.52E 04 3.80E-07 9.84E+04 1.97E+05 7.88E+04 2.36E+02 20 0.15 13.13 33.53 4.3M 07 7.78E 07 5.62E 05 8.47E 06 2.20E+04 4.40E+04 1.76E+04 5.28E+01 20 0.22 1.08 2.75 3.58E La 6.39E 08 4.62E-06 6.95E 09 1.82E+03 3.63E+03 1.46E+03 4.33E+00 20 1 '.5 0.00 56.98 145.44 1.89E 06 3.37E-06 2.44E 04 3.67E 07 9.52E+04 1.91E+05 7.62E+04 2.29E+02 20 0.11 34.56 88.22 1.15E 06 2.05E 06 1.48E 04 2.23E 07 5.77E+04 1.16E+05 4.62E+04 1.39E+02 20 0.22 7.71 19.68 2.56E 07 4.57E-07 3.30E 05 4.97E-08 1.29E+04 2.59E+04 1.03E+04 3.10E+01 20 0.32 0.63 1.62 2.10E-08 3.75E-06 2.71E 06 4.08E 09 1.00E+03 2.14E+03 8.66E+02 2.54E+00 20 2.0 0.00 40.56 101.37 1.21E 06 2.29E 06 1.65E-04 2.29E 07 6.09E+04 1.29E+05 4.57E+04 1.37E+02 20 0.14 24.60 61.49 7.34E-07 1.39E 06 1.00E 04 1.39E 07 3.70E+04 7.85E+04 2.77E+04 8.32E+01 20 0.28 5.49 13.72 1.64E-07 3.09E 07 2.24E-05 3.10E-08 8.26E+03 1.75E+04 6.20E+03 1.86E+01 20 0.42 0.45 1.13 1.35E 08 2.54E-08 1.84E 06 2.55E 09 6.97E+02 1.46E+03 5.28E+02 1.52E+00 20 3.0 0.00 23.50 58.74 7.13E-07 1.35E-06' 9.57E 05 1.35E-07 3.59E+04 7.62E+04 ' 2.69E+04 8.08E+01 20 0.20 14.25 35.63 4.32E 07 8.16E 07 5.81E 05 8.19E-08 2.18E+04 4.62E+04 1.63E+04 4.90E+01 20 0.39 3.18 7.95 9.65E-08 1.82E-07 1.30E-05 1.83E-08 4.87E+03 1.03E+04 3.66E+03 1.09E+01 20 0.59 0.26 0.65 7.92E 09 1.49E 08 1.06E 06 1.50E 09 4.18E+02 8.66E+02 3.19E+02 8.98E 01 2C 4.0 0.00 16.78 41.01 4.67E-07 9.40E-07 6.49E 05 8.62E-06 2.35E+04 5.32E+04 1.65E+04 4.95E+01 20 0.25 10.18 24.88

'2.83E 07 5.70E 07 3.94E-05 5.23E 08 1.43E+04 3.23E+04 1.00E+04 3.00E+01 20 0.50 2.27 5.55 6.32E-06 1.27E-07 8.78E-06 1.17E-08 3.20E+03 7.22E+03 2.25E+03 6.70E+00 20 0.75 0.19 0.46 5.19E-09 1.04E 08 7.21E-07 9.57E 10 2.81E+02 6.11E+02 2.03E+02 5.50E 01 20

Stato of Texas

,1995 Graded Exercise 06-December-1995 REAL TIME:

12:30 RELATIVE TIME:

H+05:30 LOCATION l

DOSE RATE l

AIR CONCENTRATION l AIR SAMPLE CPM l GROUW DEPOSIT!0N l annanne Donal DIST.

CLOBED GPEN OROSS GROSS NOBLE 10 DINE GROSS GROSS GROSS NET BACKGROUN WIND OFF WINDOW WINDOW 10 DINE PART.

GAS 131 10 DINE PART.

DEPOSIT.

GROUND COUNT DIST CENT.

DOSE R.

DOSE R.

ACTIVITY ACTIVITY ACTIVITY ACTIVITY COUNT R.

COUNT R.

COUNT R.

DEPOSIT.

RATE (7.I)

(MI)

(int /NR)

(int /NR) (UCI/CC)

(UCI/CC)

(UCI/CC)

(UCl/CC)

(CPN)

(CPM)

(CPM)

(UC1/M2)

(CPM) 5.0 0.00 13.03 31.11 3.35E 07 7.Z3E 07 4.78E 05 6.00E 08 1.68E+06 4.09E+04 1.10F+04 3.31E+01 20 0.30-7.91 18.87 2.03E 07 4.38E 07 2.90E 05 3.64E 08 1.02E+04 2.48E+04 6.70E+03 2.01E+01 20 0.60 1.76 4.21 4.53E 08 9.78E 08 6.47E 06 8.11E 09 2.30E+03 5.56E+03 1.51E+03 4.48E+00 20 0.89 0.14 0.35 3.72E 09 8.03E-09 5.31E-07 6.66E-10 2.07E+02 4.74E+02 1.42E+02 3.68E 01 20 6.0 0.00 10.33 24.67 2.69E 07 5.82E 07 3.79E-05 4.82E 08 1.36E+04 3.29E+04 8.89E+03 2.66E+01 20 0.34 6.27 14.%

1.63E 07 3.53E 07 2.30E 05 2.93E 08 8.23E+03 2.00E+04 5.40E+03 1.61E+01 20 0.69 1.40 3.34 3.64E 08 7.87E-08 5.12E 06 6.53E-09 1.85E+03 4.47E+03 1.22E+03 3.60E+00 20 1.03 0.11 0.27 2.99E 09 6.46E-09 4.21E 07 5.36E 10 1.70E+02 3.86E+02 1.18E+02 2.96E 01 20 7.0 0.00 8.74 20.35 2.10E-07 4.92E-07 3.03E.05 3.65E-08 1.06E+04 2.79E+04 6.47E+03 1.94E+01 20 0.38 5.30 12.34 1.27E-07 2.99E-07 1.84E-05 2.22E 08 6.43E+03 1.69E+04 3.93E+03 1.17E+01 20 0.77 1.18 2.75 2.84E 08 6.66E 08 4.10E-06 4.96E 09 1.45E+03 3.79E+03 8.92E+02 2.62E+00 20 1.15 0.10 0.23 2.33E 09 5.47E 09 3.36E-07 4.06E 10 1.37E+02 3.29E+02 9.16E+01 2.15E 01 20 8.0 0.00 7.41 17.26 1.80E-07 4.23E 07 2.57E-05 3.13E 08 9.09E+03 2.39E+04 5.55E+03 1.66E+01 20 O.42 4.50 10.47 1.09E-07 2.56E-07 1.56E 05 1.90E-08 5.52E+03 1.45E+04 3.38E+03 1.01E+01 20

'0.85 1.00 2.34 2.44E 08 5.72E-08 3.47E 06 4.24E-09 1.25E+03 3.26E+03 7.69E+02 2.25E+00 20 1.27 0.08 0.19 2.00E 09 4.69E-09 2.85E 07 3.48E-10 1.21E+02 2.86E+02 8.15E+01 1.85E 01 20 9.0 0.00 6.47 14.67 1.45E-07 3.72E 07 2.11E 05 2.44E-08 7.31E+03 2.11E+04 4.14E+03 1.24E+01 20 0.46 3.93 8.90 8.79E 06 2.26E-07 1.28E-05 1.48E 08 4.44E+03 1.28E+04 2.52E+03 7.51E+00 20 0.92 0.88 1.99 1.96E 08 5.03E 08 2.85E-06 3.30E-09 1.01E+03 2.87E+03 5.78E+02 1.68E+00 20 1.38 0.07 0.16 1.61E 09 4.13E 09 2.34E 07 2.71E-10 1.01E+02 2.54E+02 6.58E+01 1.38E-01 20 10.0 0.00 5.58 12.29 1.14E 07 3.23E 07 1.70E 05 1.85E 08 5.76E+03 1.83E+04 2.99E+03 8.92E+00 20 0.50 3.38 7.45 6.92E-08 1.96E 07 1.03E 05 1.12E 05 3.50E+03 1.11E+04 1.82E+03 5.41E+00.

20 0.99 0.76 1.66 1.54E 08 4.37E-05 2.30E-06 2.51E 09 7.97E+02 2.50E+03 4.22E+02 1.21E+00 20 1.49 0.06 0.14 1.27E-09 3.59E-09 1.89E-07 2.06E-10 8.38E+01 2.23E+02 5.30E+01 9.91E 02 20 1995 Graded Exercise O

Steto of Tcxac 1995 Gra ed d Exercise 06-December-1995 REAL TIME:

12:45 RELATIVE TIME:

H+05:45 ococe***************************************************************************

OFFSITE RADIOLOGICAL SURVEY DATA o*ooo***************************************************************************


METEOROLOGICAL DATA---------- ------------RELEASE DATA---------------

WIND SPEED (MPH) 9.00 NOBLE GAS (CI/SEC) 4.034E+01 DELTA-T (DEG. F/50M)

-1.00 IODINE (CI/SEC) 3.340E-01 STABILITY CLASS (PASQUILL)

D PARTICULATE (CI/SEC) 5.6'52E-01 WIND DIRECTION (DEGREES) 234.0 TOTAL (CI/SEC) 4.124E+01 PLUME TRAVEL (MI) 2.781E+01 AVERAGE GAMMA'(MEV/ DIS) 0.37 PLUME TRAILING EDGE (MI) 0.000E+00 AVERAGE BETA (MEV/ DIS) 0.23 1995 Graded Exercise LOCATION l

DOSE RATE l

AIR CONCENTRAfl0N l AIR SAMPLE CPM l GROUND DEPOSITION l BACKGROUN DOWN DIST.

CLOSE0 OPEN GROSS GROSS NOBLE ICDINE GROSS GROSS GROSS NET BACKGROUN WIND OFF WINDOW WINDOW IODINE PART.

GAS 131 IODINE PART.

' DEPOSIT.

GROUND COUNT O!ST CENT.

DOSE R.

DOSE A.

ACTIVITY ACTIVITY ACTIVITY ACTIVITY COUNT R.

COUNT R.

COUNT R.

DEPOSIT.

RATE (MI)

(MI)

(MR/NR)

(MR/HR) (UCI/CC)

(UCl/CC) (UCl/CC) (UCI/CC)

(CPM)

(CPM)

(CPM)

(UCI/M2)

(CPM) 0.5 0.00 203.12 529.02 7.28E 06 1.23E 05 9.13E-04 1.45E-06 3.66E+05 6.97E+05 3.04E+05 9.12E+02 20 0.04 123.20 320.86 4.41E-06 7.47E 06 5.54E-04 8.77E 07 2.22E+05 4.23E+05 1.84E+05 5.53E+02 20 O.08 27.49 71.59 9.85E 07 1.67E-06 1.24E-04 1.96E-07 4.95E+04 9.44E+04 4.11E+04 1.23E+02 20 0.12 2.26 5.88 8.08E-08 1.37E-07 1.01E 05 1.61E 08 4.09E+03 7.77E+03 3.39E+03 1.01E+01 20 1.0 0.00 91.82 239.14 3.19E 06 5.41E 06 4.13E 04 6.34E 07 1.61E+05 3.06E+05 1.33E+05 4.00E+02 20 0.07 55.69 145.04 1.94E-06 3.28E-06 2.51E-04 3.85E 07 9.74E+04 1.86E+05 8.08E+04 2.42E+02 20 0.15 12.43 32.36 4.32E 07 7.32E-07 5.59E-05 8.58E 08 2.17E+04 4.14E+04 1.80E+04 5.41E+01 20 0.22 1.02 2.66 3.54E 08 6.00E 08 4.59E-06 7.04E 09 1.80E+03 3.42E+03 1.50E+03 4.44E+00 20 1.5 0.00 53.90 140.39 1.87E-06 3.17E-06 2.43E-04 3.72E 07 9.42E+04 1.79E+05 7.81E+04 2.35E+02 20 0.11 32.69 85.15 1.14E 06 1.92E 06 1.47E-04 2.26E 07 5.71E+04 1.09E+05 4.74E+04 1.42E+02 20 0.22 7.29 19.00 2.53E 07 4.29E-07 3.28E-05 5.03E 08 1.28E+04 2.43E+04 1.06E+04 3.17E+01 20 0.32 0.60 1.56 2.08E 08 3.52E 08 2.69E 06 4.13E-09 1.07E+03 2.01E+03 8.88E+02 2.61E+00 20 2.0 0.00 38.48 98.23 1.20E 06 2.15E 06 1.65E-04 2.34E-07 6.05E+04 1.21E+05 4.71E+04 1.41E+02 20 0.14 23.34 59.58 7.30E-07 1.30E-06 1.00E-04 1.42E 07 3.67E+04 7.37E+04 2.86E+04 8.57E+01 20 0.28 5.21 13.29 1.63E-07 2.91E-07 2.23E-05 3.16E-08 8.21E+03 1.65E+04 6.39E+03 1.91E+01 20 0.42 0.43 1.09 1.34E-08 2.38E 08 1.83E 06 2.59E-09 6.92E+02 1.37E+03 5.43E+02 1.57E+00 20 l

3.0 0.00 22.30 56.92 7.08E 07 1.26E-06 9.56E-05 1.37E-07 3.56E+04 7.15E+04 2.77E+04 8.32E+01 20 l

0.20 13.52 34.52 4.30E-07 7.67E-07 5.80E-05 8.34E-08 2.16E+04 4.34E+04 1.68E+04 5.05E+01 20 l

0.39 3.02 7.70 9.59E-08 1.71E-07 1.29E-05 1.86E-08 4.84E+03 9.70E+03 3.77E+03 1.13E+01 20 j

0.59 0.25 0.63 7.87E-09 1.40E-08 1.06E-06 1.53E-09 4.16E+02 8.15E+02 3.28E+02 9.24E-01 20 4.0 0.00 15.99 39.97 4.67E-07 8.82E-07 6.52E-05 8.84E-08 2.35E+04 5.00E+04 1.71E+04 5.13E+01 20 0.25 9.70 24.24 2.83E-07 5.35E-07 3.95E 05 5.36E 08 1.43E+04 3.03E+04 1.04E+04 3.11E+01 20 0.50 2.16 5.41 6.32E-08 1.19E-07 8.82E-06 1.20E-08 3.20E+03 6.78E+03 2.33E+03 6.95E+00 20 0.75 0.18 0.44 5.19E-09 9.80E-09 7.24E-07 9.83E-10 2.81E+02 5.75E+02 2.10E+02 5.70E-01 20 i

I

Stcto of T;xac 1995 Graded Exercise 06-December-1995 REAL TIME:

12:45 RELATIVE TIME:

H+05:45 LOCAil0N l

DOSE RATE l

AIR CONCENTRATION l AIR SAMPLE CPM l GROUND DEPOSITION l 8ACKGROUN DOWN DIST.

CLOSED OPEN GROSS Gross N08LE 10 DINE GROSS GROSS GROSS NET 8ACKGROUN WIND OFF WINDOW WINDOW IODINE PART.

GAS 131 IODINE PART.

DEPOSIT.

GROUND COUNT DIST CENT.

DOSE R.

DOSE R.

ACTIVITY ACTIVITY ACTIVITY ACTIVITY COUN1 R.

COUNT R.

COUNT R.

DEPOSIT.

RATE C:1) (MI)

(MR/NR)

(MR/NR) (UCI/CC)

(UCl/CC) (UCl/CC) (UCl/CC)

(CPM)

(CPM)

(CPM)

(UCI/M2)

(CPM) 5.0 0.00 12.51 30.58 3.38E 07 6.80E 07 4.84E 05 6.23E 08 1.70E+04 3.85E+04 1.16E+04 3.46E+01 20 0.30 7.59 18.55 2.05E 07 4.12E 07 2.94E-05 3.78E-08 1.03E+04 2.33E+04 7.02E+03 2.10E+01 20 0.60 1.69 4.14 4.57E-08 9.20E 08 6.55E-06 8.42E 09 2.32E+03 5.22E+03 1.58E+03 4.69E+00 20 O.89 0.14 0.34 3.75E 09 7.55E 09 5.38E-07 6.92E 10 2.09E+02 4.47E+02 1.48E+02 3.85E 01 20 6.0 0.00 9.92 24.24 2.72E-07 5.47E 07 3.84E 05 5.01E-08 1.37E+04 3.10E+04 9.30E+03 2.79E+01 20 0.34 6.02 14.71 1.65E-07 3.32E 07 2.33E-05 3.04E 08 8.31E+03 1.88E+04 5.65E+03 1.69E+01 20 0.69 1.34 3.28 3.68E 08 7.40E 08 5.19E 06 6.78E-09 1.87E+03 4.21E+03 1.28E+03 3.77E+00 20 1.03 0.11 0.27 3.02E-07 6.07E-09 4.26E 07 5.56E-10 1.72E+02 3.64E+02 1.23E+02 3.10E 01 20 7.0 0.00 8.48 20.26 2.15E-07 4.65E 07 3.11E 05 3.86E-08 1.0BE+04 2.63E+04 6.88E+03 2.06E+01 20 0.38 5.15 12.29 1.30E 07 2.82E 07 1.89E 05 2.34E-08 6.58E+03 1.60E+04 4418E+03 1.25E+01 20 0.77 1.15 2.74 2.91E-08 6.30E 08 4.21E-06 5.22E 09 1.48E+03 3.58E+03 9.49E+02 2.79E+00 20 1.15 0'09 0.23 2.39E-09 5.17E-09 3.46E-07 4.28E-10 1.40E+02 3.12E+02 9.63E+01' 2.29E 01 20 8.0 0.00 7.20 17.18 1.85E-07 3.99E-07 2.64E-05 3.31E 08 9.31E+03 2.26E+04 5.91E+03 1.77E+01 20 O.42 4.36 10.42 1.12E-07 2.42E-07 1.60E-05 2.01E-08 5.65E+03 1.37E+04 3.59E+03 1.07E+01 20 0.85 0.97 2.32 2.50E-08 5.40E 08 3.57E-06

,.48E 09 1.28E+03 3.08E+03 8.17E+02 2.39E+00 20 1.27 0.08 0.19 2.05E 09 4.44E-09 2.93E 07 3.68E 10 1.23E+02 2.71E+02 8.55E+01 1.97E 01 20 9.0 0.00 6.40 14.89 1.52E 07 3.56E 07 2.22E 05 2.64E-08 7.66E+03 2.02E+04 4.54E+03 1.36E+01 20 0.46 3.88 9.03 9.21E-06 2.16E 07 1.34E-05 1.60E 08 4.65E+03 1.22E+04 2.76E+03 8.23E+00 20 0.92 0.87 4.02 2.06E 08 4.82E 08 3.00E 06 3.5?E-09 1.05E+03 2.75E+03 6.31E+02 1.84E+00 20 1.38 0.07 0.17 1.69E-09 3.96E-09 2.46E-07 2.93E-10 1.05E+02 2.44E+02 7.02E+01 1.51E-01 20 10.0 0.00 5.68 12.87 1.24E-07 3.19E 07 1.85E 05 2.09E 08 6.28E+03 1.81E+04 3.44E+03 1.03E+01 20 0.50 3.44 7.81 7.54E-08 1.94E-07 1.12E-05 1.27E 08 3.81E+03 1.10E+04 2.09E+03 6.23E+00 20 0.99 0.77 1.74 1.68E-08 4.32E-08 2.51E-06 2.83E 09 8.67E+02 2.47E+03 4.83E+02 1.39E+00 20 1.47 0.06 0.14 1.38E 09 3.55E-09 2.06E-07 2.32E-10 8.95E+01 2.21E+02 5.80E+01 1.14E-01 20 1995 Graded Exercise

Ctate of Texao 1995 Graded Exercise 06-December-1995 l

REAL TIME:

13:00 RE H+06:00 ooooo********************************************.**LATIVE TIME:

OFFSITE RADIOLOGICAL SURVEY DA ooooo************************************************TA


METEOROLOGICAL DATA----------


RELEASE DATA---------------

WIND SPEED (MPH) 9.00 NOBLE GAS (CI/SEC) 4.000E+01 DELTA-T (DEG. F/50M)

-1.00 IODINE (CI/SEC) 3.296E-01 STABILITY CLASS (PASQUILL)

D PARTICULATE (CI/SEC) 5.318E-01 WIND DIRECTION (DEGREES) 240.0 TOTAL (CI/SEC) 4.086E+01 PLUME TRAVEL (MI) 3.006E+01 AVERAGE GAMMA (MEV/ DIS) 0.35 PLUME TRAILING EDGE (MI) 0.000E+00 AVERAGE BETA (MEV/ DIS) 0.23 1995 Graded Exercise LOCATION l

00$E RATE l

AIR CONCENTRATION l AIR SAMPLE CPM l GROUND DEPOSITION l BACKGROUN DOWN DIST.

CLOSED OPEN GROSS GROSS NOBLE IODINE GROSS GROSS GROSS NET BACKGROUN WINO OFF WINDOW WINDOW IODINE PART.

GAS 131 10 DINE PART.

DEPOSIT.

GROUND COUNT DIST CENT.

DOSE R.

DOSE R.

ACTIVITY ACTIVITY ACTIVITY ACTIVITY COUNT R.

COUNT R.

COUNT R.

DEPOSIT.

RATE (MI)

(MI)

(MR/HR)

(MR/HR) (UCI/CC)

(UCI/CC) (UCI/CC)

(UCI/CC)

(CPM)

(CPM)

(CPM)

(UCI/M2)

(CPM) 0.5 0.00 191.85 509.30 7.18E-06 1.16E-05 9.05E-04 1.46E 06 3.61E+05 6.56E+05 3.13E+05 9.39E+02 20 0.04 116.36 308.91 4.36E 06 7.03E 06 5.49E-04 8.85E 07 2.19E+05 3.98E+05 1.90E+05 5.69E+02 20 0.08 25.96 68.93 9.72E-07 1.57E 06 1.23E 04 1.97E 07 4.89E+04 8.88E+04 4.23E+04 1.27E+02 20 0.12 2.13 5.66 7.98E*06 1.29E-07 1.01E-05 1.62E 08 4.03E+03 7.31E+03 3.49E+03 1.04E+01 20 1.0 0.00 86.73 230.23 3.15E-06 5.09E-06 4.10E 04 6.40E-07 1.58E+05 2.88E+05 1.37E+05 4.12E+02 20 0.07 52.60 139.64 1.91E-06 3.08E-06 2.48E-04 3.88E-07 9.61E+04 1.75E+05 8.32E+04 2.50E+02 20 0.15 11.74 31.16 4.26E 07 6.88E-07 5.54E 05 8.66E-08 2.15E+04 3.90E+04 1.86E+04 5.57E+01 20 0.22 0.96 2.56 3.50E 08 5.65E-08 4.55E-06 7.11E 09 1.78E+03 3.22E+03 1.54E+03 4.57E+00 20 1.5 0.00 50.91 135.16 1.85E-06 2.98E-06 2.40E-04 3.75E 07 9.30E+04 1.69E+05 8.05E+04' 2.42E+02 20 0.11 30.88 81.98 1.12E-06 1.81E 06 1.46E-04 2.28E 07 5.64E+04 1.02E+05 4.88E+04 1.47E+02 20 0.22 6.89 18.29 2.50E 07 4.04E-07 3.25E 05 5.08E 08 1.26E+04 2.29E+04 1.09E+04 3.27E+01 20 0.32 0.57 1.50 2.05E 08 3.32E 08 2.67E-06 4.17E-09 1.05E+03 1.90E+03 9.14E+02 2.68E+00 20 2.0 0.00 36.41 94.82 1.19E 06 2.02E-06 1.64E 04 2.37E-07 5.99E+04 1.14E+05 4.87E+04 1.46E+02 20 0.14 22.08 57.51 7.22E-07 1.22E-06 9.95E-05 1.43E 07 3.63E+04 6.93E+04 2.95E+04 8.86E+01 20 0.28 4.93 12.83 1.61E 07 2.73E-07 2.22E 05 3.20E 08 8.12E+03 1.55E+04 6.60E+03 1.98E+01 20 0.42 0.40 1.05 1.32E 08 2.24E-08 1.82E-06 2.63E-09 6.85E+02 1.29E+03 5.60E+02 1.62E+00 20 3.0 0.00 21.09 54.94 7.01E-07 1.19E-06 9.50E 05 1.39E-07 3.53E+04 6.73E+04 2.87E+04 8.60E+01 20 0.20 12.79 33.32 4.25E-07 7.21E-07 5.76E 05 8.45E-08 2.14E+04 4.08E+04 1.74E+04 5.22E+01 20 0.39 2.85 7.44 9.49E-08 1.61E-07 1.29E 05 1.88E-08 4.79E+03 9.12E+03 3.89E+03 1.16E+01 20 l

0.59 0.23 0.61 7.79E-09 1.32E 08 1.06E 06 1.55E-09 4.12E+02 7.67E+02 3.38E+02 9.55E 01 20 l

1 4.0 0.00 15.17 38.73 4.64E 07 8.29E-07 6.51E 05 9.01E 08 2.34E+04 4.69E+04 1.78E+04 5.33E+01 20 0.25 9.20 23.49 2.82E-07 5.03E-07 3.95E-05 5.46E 08 1.42E+04 2.85E+04 1.08E+04 3.23E+01 20 0.50 2.05 5.24 6.28E-08 1.12E 07 8.81E-06 1.22E 08 3.18E+03 6.37E+03 2.42E+03 7.21E+00 20 l

l 0.75 0.17 0.43 5.16E-09 9.21E-09 7.23E-07 1.00E-09 2.79E+02 5.41E+02 2.17E+02 5.92E-01 20

Stato of Tcxts

,1995 Graded Exercise 06-December-1995 REAL TIME:

13:00 RELATIVE TIME:

H+06:00 LOCATION l

DOBE RATE l

AIR CONCENTRATION l AIR SAMPLE CPM l GROUND DEPOSITION l BACKGROUN i DOWN DIST.

CLOBED OPEN GROSS GROSS NOBLE 10 DINE GROSS GROSS GROSS NET 8ACKGROUN WINO 0FF WINDOW WINDOW 10 DINE PART.

GAS 131 IODINE PART.

DEPOSIT.

GROUND COUNT-DIST CENT.

DOBE R.

DOSE R.

ACTIVITY ACTIVITY ACTIVITY ACTIVITY COUNT R.

COUNT R.

COUNT R.

DEPOSIT.

RATE (MI)

(MI)

(MR/NR)

(MR/NR) (UCI/CC)

(UCI/CC) (UCI/CC) (UCI/CC)

(CPM)

(CPM)

(CPM)

(UCI/M2)

(CPM) i 5.0 0.00 11.92 29.80 3.38E 07 6.38E 07 4.86E 05 6.39E 08 1.70E+04 3.61E+04 1.21E+04 3.62E+01 20 j

0.30 7.23 18.08 2.05E-07 3.87E 07 2.95E 05 3.88E 08 1.03E+04 2.19E+04 7.34E+03 2.20E+01 20 0.60 1.61 4.03 4.57E-08 8.64E 08 6.58E 06 8.65E 09 2.32E+03 4.91E+03 1.65E+03 4.90E+00 20 0.89 0.13 0.33 3.75E 09 7.09E 09 5.40E-07 7.10E 10 2.09E+02 4.21E+02 1.54E+02 4.03E 01 20 6.0 0.00 9.45 23.63 2.72E 07 5.13E 07 3.85E 05 5.14E 08 1.37E+04 2.91E+04 9.73E+03 2.92E+01 20 0.34

5. 73 14.33 1.65E 07 3.11E-07 2.34E-05 3.12E 08 8.30E+03 1.76E+04 5.91E+03 1.77E+01 20 0.69 1.28 3.20 3.67E-08 6.95E 08 5.22E-06 6.96E 09 1.87E+03 3.95E+03 1.33E+03 3.95E+00 20 1.03 0.11 0.26 3.02E 09 5.70E 09 4.28E-07 5.71E-10 1.72E+02 3.43E+02 1.28E+02 3.24E 01 20 7.0 0.00 8.14 19.91 2.17E 07 4.37E 07 3.15E 05 4.00E-08 1.09E+04 2.48E+04 7.28E+03 2.18E+01 20 0.38 4.94 12.07 1.32E-07 2.65E-07 1.91E-05 2.43E-08 6.64F+03 1.50E+04 4.42E+03 1.32E+01 20 0.77 1.10 2.69 2.94E-08 5.92E-08 4.27E 06 5.42E-09 1.50E+03 3.37E+03 1.00E+03 2.95E+00 20 1.15 0.09 0.22 2.41E-09 4.86E 09 3.50E 07 4.45E-10 1.41E+02 2.95E+02 1.01E+02 2.42E 01 20 8.0 0.00 6.91 16.88 1.86E 07 3.75E 07 2.67E-05 3.44E 08 9.39E+03 2.13E+04 6.25E+03 1.87E+01 20 O.42 4.19 10.24 1.13E 07 2.28E-07 1.62E 05 2.00E-08 5.70E+03 1.29E+04 3.80E+03 1.13E+01 20 0.85 0.93 2.28 2.52E 08 5.08E-06 3.62E-06 4.65E 09 1.29E+C3 2.90E+03 8.63E+02 2.53E+00 20 1.27 0.08 0.19 2.07E 09 4.17E 09 2.97E-07 3.82E-10 1.24E+02 2.56E+02 8.92E+01 2.08E-01 20 9.0 0.00 6.21 14.82 1.56E 07 3.37E 07 2.28E-05 2.79E-08 7.84E+03 1.91E+04 4.88E+03 1.465+01 20 0.46 3.77 8.99 9.43E 06 2.04E-07 1.38E 05 1.69E 08 4.76E+03 1.16E+04 2.97E+03 8.85E+00 20 0.92 0.84 2.01 2.10E-08 4.56E 06 3.00E 06 3.TTE 09 1.08E+03 2.60E+03 6.78E+02 1.98E+00 20 1.38 0.07 0.16 1.73E 09 3.74E 09 2.53E-07 3.10E 10 1.07E+02 2.32E+02 7.40E+01 1.62E-01 20 10.0 0.00 5.61 13.07 1.30E-07 3.06E 07 1.94E-05 2.27E 08 6.58E+03 1.73E+04 3.81E+03 1.14E+01 20 0.50 3.40 7.93 7.91E 08 1.86E 07 1.18E 05 1.37E-08 4.00E+03 1.05E+04 2.32E+03 6.91E+00 20 0.99 0.76 1,77 1.76E 08 4.14E 08 2.63E-06 3.07E-09 9.07E+02 2.36E+03 5.33E+02 1.54E+00 20 1.49 0.06 0.15 1.45E 09 3.40E-09 2.16E 07 2.52E-10 9.28E+01 2.12E+02 6.21E+01 1.26E-01 20 1995 Graded Exercise A

Stato of Texas 1M5 Graded Exercise 06-December-1995 4

REAL TIME:

13:15 RELATIVE TIME:

H+06:15 eeeee***************************************************************************

OFFSITE RADIOLOGICAL SURVEY DATA eeooo***************************************************************************


METEOROLOGICAL DATA----------


RELEASE DATA---------------

WIND SPEED (MPH) 9.00 NOBLE GAS (CI/SEC) 3.958E+01 DELTA-T (DEG. F/50M)

-1.10 IODINE (CI/SEC) 3.248E-01 STABILITY CLASS (PASQUILL)

D PARTICULATE (CI/SEC) 5.006E-01 WIND DIRECTION (DEGREES) 240.0 TOTAL (CI/SEC) 4.040E+01 PLUME TRAVEL (MI) 3.231E+01 AVERAGE GAMMA (MEV/ DIS) 0.34 PLUME TRAILING EDGE (MI) 0.000E+00 AVERAGE BETA (MEV/ DIS) 0.22 1995 Graded Exercise LOCATION l

DOSE RATE l

AIR CONCENTRATION l AIR SAMPLE CPM l GROUND DEPOSITION l BACKGROUN DOWN DIST.

CLOSED OPEN GROSS GROSS NOBLE 10 DINE GROSS GROSS GROSS NET BACKGROUN WIND OFF WINDOW WINDOW 10 DINE PART.

GAS 131 10 DINE PART.

DEPOSIT.

GROUND COUNT DIST CENT.

DOSE R.

DOSE R.

ACTIVITY ACTIVITY ACTIVITY ACTIVITY COUNT R.

COUNT R.

COUNT R.

DEPOSIT.

RATE (MI)

(MI)

(MR/NR)

(MR/NR) (UC1/CC)

(UCI/CC)

(UCI/CC)

(UCI/CC)

(CPM)

(CPM)

(CPM)

(UCI/M2)

(CPM) 0.5 0.00 181.08 489.48 7.00E 06 1.09E 05 8.96E-04 1.47E-06 3.56E+05 6.18E+05 3.22E+05 9.68E+02 20 0.04 109.83 296.89 4.29E 06 6.62E-06 5.43E 04 8.90E 07 2.16E+05 3.75E+05 1.96E+05 5.87E+02 20 0.08 24.51 66.24 9.58E-07 1.48E 06 1.21E-04 1.99E 07 4.82E+04 8.36E+04 4.37E+04 1.31E+02 20 0.12 2.01 5.44 7.86E-08 1.21E 07 9.95E 06 1.63E 08 3.97E+03 6.88E+03 3.60E+03 1.08E+01 20 1.0 0.00 81.86 221.28 3.10E 06 4.79E 06 4.05E 04 6.44E-07 1.56E+05 2.71E+05 1.41E+05 4.25E+02 20 0.07 49.65 134.21 1.88E 06 2.90E 06 2.46E 04 3.90E-07 9.47E+04 1.64E+05 8.58E+04 2.58E+02 20 0.15 11.08 29.95 4.20E 07 6.48E 07 5.48E-05 8.71E-06 2.11E+04 3.67E+04 1.92E+04 5.75E+01 20 0.22 0.91 2.46 3.45E 08 5.32E 08 4.50E-06 7.15E 09 1.75E+03 3.03E+03 1.59E+03 4.72E+00 20 1.5 0.00 48.06 129.90 1.82E 06 2.81E-06 2.38E-04 3.78E 07 9.16E+04 1.59E+05 8.30E+04 2.49E+02 20 0.11 29.15 78.79 1.10E-06 1.70E-06 1.44E-04 2.29E-07 5.56E+04 9.64E+04 5.04E+04 1.51E+02 20 0.22 6.50 17.58 2.46E 07 3.80E 07 3.22E 05 5.11E-08 1.24E+04 2.15E+04 1.13E+04 3.37E+01 20 0.32 0.53 1.44 2.02E-08 3.12E-08 2.64E-06 4.20E 09 1.04E+03 1.79E+03 9.42E+02 2.77E+00 20 2.0 0.00 34.39 91.29 1.17E 06 1.90E 06 1.63E-04 2.39E-07 5.91E+04 1.07E+05 5.04E+04 1.51E+02 20 0.14 20.86 55.37 7.13E-07 1.15E-06 9.86E-05 1.45E-07 3.59E+04 6.52E+C4 3.05E+04 9.17E+01 20 0.28 4.65 12.36 1.59E-07 2.57E-07 2.20E-05 3.23E-08 8.02E+03 1.46E+04 6.83E+03 2.05E+01 20 0.42 0.38 1.01 1.31E 08 2.11E 08 1.81E-06 2.65E-09 6.77E+02 1.21E+03 5.79E+02 1.68E+00 20 3.0 0.00 19.93 52.89 6.92E-07 1.12E 06 9.42E-05 1.41E-07 3.48E+04 6.33E+04 2.97E+04 8.90E+01 20 0.20 12.09 32.08 4.20E 07 6.7BE 07 5.71E-05 8.52E-08 2.11E+04 3.84E+04 1.80E+04 5.40E+01 20 0.39 2.70 7.16 9.36E 08 1.51E 07 1.27E-05 1.90E-08 4.73E+03 8.58E+03 4.03E+03 1.20E+01 20 0.59 0.22 0.59 7.68E 09 1.24E-08 1.05E 06 1.56E-09 4.07E+02 7.23E+02 7.49E+02 9.89E-01 20 4.0 0.00 14.36 37.39 4.59E-07 7.79E 07 6.47E 05 9.13E-08 2.31E+04 4.41E+04 1.85E+04 5.54E+01 20 0.25 8.71 22.68 2.79E-07 4.73E 07 3.92E-05 5.53E 08 1.40E+04 2.68E+04 1.12E+04 3.36E+01 20 0.50 1.94 5.06 6.22E-08 1.05E-07 8.76E-06 1.24E-08 3.15E+C3 5.99E+03 2.52E+03 7.50E+00 20,

j 0.75 0.16 0.42 5.10E-09 8.66E-09 7.19E-07 1.01E-09 2.77E+02 5.10E+02 2.25E+02 6.15E 01 20

1 State of Taxas

,1995 Graded Exercise 06-December-1995 j

REAL TIME:

13:15 RELATIVE TIME:

H+06:15 LOCATION l

DOSE RATE l

AIR CONCENTRATION l A!R SAMPLE CPM l GROUND DEPOSITION l BACKGROUN DOWN DIST.

CLOSED OPEN GROSS GROSS NOBLE 10 DINE GROSS GROSS GROSS NET BACKGROUN WIND OFF WINDOW WINDOW 10 DINE PART.

GAS 131 IdoINE PART.

DEPOSIT.

GROUND COUNT DIST CENT.

DOSE R.

DOSE R.

ACTIVITY ACTIVITY ACTIVITY ACTIVITY COUNT R.

COUNT R.

COUNT R.

DEPOSIT.

RATE

(%I) (MI)

(MR/NR) (MR/NR) (UCI/CC) (UCI/CC) (UCl/CC)

(UCI/CC)

(CPM)

(CPM)

(CPM)

(UCI/M2)

(CPM) 5.0 0.00 11.31 28.88 3.35E-07 6.00E 07 4.86E-05 6.51E 08 1.69E+04 3.39E+04 1.26E+04 3.79E+01 20 0.30 6.86 17.52 2.03E 07 3.64E 07 2.94E 05 3.95E 08 1.03E+04 2.06E+04 7.67E+03 2.30E+01 20 0.60 1.53 3.91 4.54E 08 8.11E 08 6.57E 06 8.81E-09 2.30E+03 4.61E+03 1.73E+03 5.12E+00 20 0.89 0.13 0.32 3.73E 09 6.66E-09 5.39E 07 7.23E 10 2.07E+02 3.97E+02 1.60E+02 4.21E 01 20 6.0 0.00 8.97 22.90 2.70E-07 4.82E 07 3.85E-05 5.24E 08 1.36E+04 2.73E+04 1.02E+04 3.05E+01 20 0.34 5.44 13.89 1.64E 07 2.93E 07 2.33E 05 3.18E-08 8.25E+03 1.66E+04 6.17E+03 1.85E+01 20 0.69 1.21 3.10 3.65E-08 6.53E 08 5.21E-06 7.09E 09 1.86E+03 3.71E+03 1.39E+03 4.12E+00 20 1.03 0.10 0.25 3.00E 09 5.36E 09 4.27E-07 5.82E-10 1.71E+02 3.23E+02 1.33E+02 3.38E 01 20 7.0 0.00 7.76 19.40 2.17E-07 4.11E 07 3.17E 05 4.11E-08 1.09E+04 2.33E+04 7.66E+03 2.29E+01 20 0.38 4.71 11.77 1.32E 07 2.49E 07 1.92E-05 2.49E 08 6.64E+03 1.41E+04 4.65E+03 1.39E+01 20 0.77 1.05 2.63 2.94E 08 5.56E 08 4.29E-06 5.56E 09 1.50E+03 3.17E+03 1.05E+03 3.10E+00 20 1.15 0.09 0.22 2.41E 09 4.56E 09 3.52E 07 4.56E-10 1.41E+02 2.78E+02 1.05E+02 2.55E 01 20 8.0 0.00 6.58 16.45 1.86E 07 3.53E 07 2.69E 05 3.53E-08 9.39E+03 2.00E+04 6.58E+03 1.97E+01 20 0.42 3.99 9.98 1.13E-07 2.14E-07 1.63E 05 2.14E 08 5.70E+03 1.21E+04 4.00E+03 1.19E+01 20 0.85 0.89 2.23 2.52E 08 4.77E 08 3.63E 06 4.77E-09 1.29E+03 2.72E+03 9.07E+02 2.66E+00 20 1.27 0.07 0.18 2.07E 09 3.92E 09 2.90E 07 3.92E 10 1.24E+02 2.42E+02 9.28E+01 2.19E 01 20 9.0 0.00 5.96 14.57 1.57E 07 3.17E-07 2.31E-05 2.89E 08 7.91E+03 1.79E+04 5.19E+03 1.55E+01 20 0.46 3.62 8.84 9.52E 08 1.92E 07 1.40E-05 1.76E-08 4.81E+03 1.09E+04 3.16E+03 9.42E+00 20 0.92 0.81 1.97 2.12E 08 4.28E 08 3.12E-06 3.92E-09 1.09E+03 2.44E+03 7.20E+02 2.10E+00 20 1.38 0.07 0.16 1.74E 09 3.52E 09 2.56E 07 3.22E 10 1.08E+02 2.19E+02 7.75E+01 1.73E-01 20 10.0 0.00 5.45 13.01 1.33E-07 2.89E 07 2.00E-05 2.39E 08 6.73E+03 1.64E+04 4.13E+03 1.23E+01 20 0.50 3.30 7.89 8.10E-08 1.75E 07 1.21E 05 1.45E-08 4.09E+03 9.95E+03 2.51E+03 7.48E+00 20 0.99 0.74 1.76 1.81E 08 3.91E-08 2.70E 06 3.24E 09 9.29E+02 2.23E+03 5.76E+02 1.67E+00 20 1.49 0.06 0.14 1.48E 09 3.21E-09 2.22E-07 2.66E 10 9.46E+01 2.02E+02 6.56E+01 1.37E 01 20 1995 Graded Exercise

Stcta of Tcxna

.1995 Graded Exercise 06-December-1995 REAL TIME:

13:30 RELATIVE TIME:

H+06:30 eeee****************************************************************************

OFFSITE RADIOLOGICAL SURVEY DATA


METEOROLOGICAL DATA---------- ------------RELEASE DATA---------------

WIND SPEED (MPH) 10.00 NOBLE GAS (CI/SEC) 3.912E+01 DELTA-T (DEG. F/50M)

-1.10 IODINE (CI/SEC) 3.197E-01 STABILITY CLASS (PASQUILL)

D PARTICULATE (CI/SEC) 4.714E-01 WIND DIRECTION (DEGREES) 240.0 TOTAL (CI/SEC) 3.991E+01 PLUME TRAVEL (MI) 3.482E+01 AVERAGE GAMMA (MEV/ DIS) 0.33 PLUME TRAILING EDGE (MI) 0.000E+00 AVERAGE BETA (MEV/ DIS) 0.22 1995 Graded Exercise LOCATION l

DOSE RATE l

AIR CONCENTRATION l AIR SAMPLE CPM l GROUND DEPOSITION l BACKGROUN DOWN DIST.

CLOSED OPEN GROSS GROSS NOBLE 10 DINE GROSS GROSS GROSS NET BACKGROUN WINO OFF WINDOW WINDOW IODINE PART.

GAS 131 IODINE PART.

' DEPOSIT.

GROUND COUNT DIST CENT.

DOSE R.

DOSE R.

ACTIVITY ACTIVITY ACTIVITY ACTIVITY COUNT R.

COUNT R.

COUNT R.

DEPOSIT.

RATE (MI)

(MI)

(MR/HR) (MR/HR) (UCl/CC). (UCl/CC) (UCI/CC)

(UC!/CC)

(CPM)

(CPM)

(CPM)

(UCl/M2)

(CPM) 0.5 0.00 153.80 422.94 6.27E-06 9.25E 06 7.97E 04 1.33E 06 3.15E+05 5.23E+05 3.28E+05 9.84E+02 20 0.04 93.28 256.53 3.80E-06 5.61E-06 4.83E 04 8.05E-07 1.91E+05 3.17E+05 1.99E+05 5.97E+02 20 0.08 20.81 57.24 8.48E-07 1.25E 06 1.08E 04 1.80E 07 4.27E+04 7.09E+04 4.44E+04 1.33E+02 20 0.12 1.71 4.70 6.96E 08 1.03E-07 8.85E 06 1.47E 08 3.52E+03 5.83E+03 3.66E+03 1.09E+01 20 1.0 0.00 69.53 191.20 2.75E 06. 4.06E 06 3.60E 04 5.82E 07 1.38E+05 2.30E+05 1.44E+05 4.32E+02 20 0.07 42.17 115.97 1.67E 06 2.46E-06 2.19E 04 3.53E 07 8.39E+04 1.39E+05 8.72E+04 2.62E+02 20 0.15 9.41 25.88 3.72E-07 5.49E-07 4.88E-05 7.87E-08 1.87E+04 3.11E+04 1.95E+04 5.84E+01 20 0.22 0.77 2.12 3.0$E 08 4.51E 08 4.00E-06 6.46E 09 1.56E+03 2.57E+03 1.62E+03 4.79E+00 20 1.5 0.00 40.82 112.24 1.61E 06 2.38E-06 2.12E-04 3.41E 07 8.12E+04 1.35E+05 8.43E+04 2.53E+02 20 0.11 24.76 68.08 9.78E 07 1.44E 06 1.28E-04 2.07E 07 4.92E+04 8.17E+04 5.12E+04 1.54E+02 20 0.22 5.52 15.19 2.18E-07 3.22E-07 2.86E 05 4.62E-08 1.10E+04 1.83E+04 1.14E+04 3.43E+01 20 0.32 0.45 1.25 1.79E-06 2.64E-08 2.35E 06 3.79E 09 9.21E+02 1.52E+03 9.57E+02 2.81E+00 20 2.0 0.00 29.21 78.97 1.04E 06 1.61E-06 1.45E-04 2.16E 07 5.24E+04 9.11E+04 5.12E+04 1.54E+02 20 0.14 17.72 47.90 6.32E 07 9.76E-07 8.78E 05 1.31E 07 3.18E+04 5.52E+04 3.11E+04 9.33E+01 20 0.28 3.95 10.69 1.41E-07 2.18E-07 1.96E-05 2.93E 08 7.11E+03 1.23E+04 6.95E+03 2.08E+01 20 0.42 0.32 0.88 1.16E-08 1.79E-08 1.61E-06 2.40E-09 6.02E+02 1.03E+03 5.89E+02 1.71E+00 20 3.0 0.00 16.93 45.75 6.13E-07 9.47E-07 8.39E-05 1.27E 07 3.09E+04 5.36E+04 3.02E+04 9.06E+01 20 0.20 10.27 27.75 3.72E 07 5.75E-07 5.09E-05 7.72E-08 1.87E+04 3.25E+04 1.83E+04 5.49E+01 20 0.39 2.29 6.19 8.30E 08 1.28E-07 1.14E-05 1.72E-OS 4.20E+03 7.27E+03 4.10E+03 1.23E+01 20 0.59 0.19 0.51 6.82E-09 1.05E-08 9.32E-07 1.41E-09 3.63E+02 6.15E+02 3.55E+02 1.01E+00 20 4.0 0.00 12.20 32.40 4.08E 07 6.6CE-07 5.TTE-05 8.29E-08 2.05E+04 3.74E+04 1.88E+04 5.65E+01 20 0.25 7.40 19.65 2.47E 07 4.00E-07 3.50E-05 5.03E 08 1.25E+04 2.27E+04 1.14E+04 3.43E+01 20 j

0.50 1.65 4.38 5.52E-08 8.93E-08 7.81E-06 1.12E-08 2.80E+03 5.07E+03 2.57E+03 7.64E+00 20 1

0.75 0.14 0.36 4.53E-09 7.33E-09 6.41E-07 9.21E 10 2.48E+02 4.35E+02 2.29E+02 6.27E-01 20 J

Stets of'Tcxas 1995 Graded Exercise 06-December-1995 REAL TIME:

13:30 RELATIVE TIME:

H+06:30 LOCATION l

DOSE RATE l

AIR CONCENTRATION l AIR SAMPLE CPM l GROUND DEPOSITION l BACKGROUN DOWN D!$T.

CLOSED OPEN GROSS,

GROSS NOBLE 10 DINE GROSS GROSS GROSS NET SACKGROUN WIND OFF WINDOW WINDOW 10 DINE PART.

GAS 131 10 DINE PART.

DEPOSIT.

GROUND COUNT DIST-CENT.

DOSE R.

DOSE R.

ACTIVITY ACTIVITY ACTIVITY ACTIVITY COUNT R.

COUNT R.

COUNT R.

DEPOSIT.

RATE (NI) (NI)

(MR/NR) (MR/NR) (UCl/CC)

(UCl/CC) (UCl/CC) (UCl/CC)

(CPM)

(CPM)

(CPM)

(UCl/N2)

(CPM) 5.0 0.00 9.63 25.09 2.99E 07 5.07E 07 4.34E 05 5.93E 08 1.50E+04 2.87E+04 1.29E+04 3.87E+01 20 0.30 5.84 15.22 1.81E 07 3.00E-07 2.63E 05 3.60E-08 9.13E+03 1.74E+04 7.83E+03 2.35E+01 20 0.60 1.30 3.40 4.04E 08 6.87E 08 5.88E-06 8.03E 09 2.05E+03 3.90E+03 1.76E+03 5.24E+00 20 0.89 0.11 0.28 3.32E 09 5.64E-09 4.83E 07 6.59E-10 1.87E+02 3.39E+02 1.63E+02 4.30E-01 20 6.0 0.00 7.64 19.89 2.40E-07 4.08E 07 3.44E-05 4.77E-08 1.21E+04 2.31E+04 1.04E+04 3.11E+01 20 0.34 4.63 12.07 1.46E-07 2.48E 07 2.09E 05 2.90E-08 7.35E+03 1.40E+04 6.31E+03 1.89E+01 20 0.69 1.03 2.69 3.25E 08 5.52E-08 4.66E 06 6.46E 09 1.66E+03 3.15E+03 1.42E+03 4.21E+00 20 1.03 0.08 0.22 2.67E-09 4.53E 09 3.82E 07 5.30E-10 1.54E+02 2.77E+02 1.35E+02 3.46E-01 20 7.0 0.00 6.63 16.92 1.94E 07 3.47E-07 2.85E-05 3.77E 08 9.78E+03 1.97E+04 7.85E+03 2.35E+01 20 0.38 4.02 10.26 1.18E-07 2.11E-07 1.73E-05 2.28E-08 5.94E+03 1.19E+04 4.77E+03 1.43E+01 20 0.77 0.90 2.29 2.63E-08 4.70E 08 3.85E-06 5.10E-09 1.34E+03 2.68E+03 1.08E+03 3.18E+00 20 1.15 0.07 0.19 2.16E-09 3.86E 09 3.16E 07 4.18E 10 1.28E+02 2.38E+02 1.07E+02 2.61E 01 20 8.0 0.00 5.62 14.35 1.67E-07 2.98E-07 2.41E 05 3.23E 08 8.40E+03 1.69E+04 6.74E+03 2.02E+01 20 0.42 3.41 8.70 1.01E-07 1.81E-07 1.46E 05 1.96E 08 5.10E+03 1.02E+04 4.105+03 1.22E+01 20 0.85 0.76 1.94 2.25E-08 4.03E-08 3.26E 06 4.38E 09 1.15E+03 2.30E+03 9.30E+02 2.73E+00 20 1.27 0.06 0.16 1.85E-09 3.31E 09 2.68E 07 3.59E 10 1.13E+02 2.07E+02 9.47E+01 2.24E-01 20 9.0 0.00 5.11 12.78 1.41E 07 2.68E-07 2.09E 05 2.67E-08 7.12E+03 1.52E+04 5.35E+03 1.60E+01 20 0.46 3.10 7.75 8.57E 08 1.62E 07 1.27E 05 1.62E 08 4.33E+03 9.20E+03 3.25E+03 9.70E+00 20 0.92 0.69

1. 73 1.91E-08 3.62E-08 2.82E 06 3.62E-09 9.81E+02 2.07E+03 7.41E+02 2.17E+00 20 1.38 0.06 0.14 1.57E-09 2.97E-09 2.32E 07 2.97E-10 9.89E+01 1.88E+02 7.92E+01 1.78E 01

' 20 10.0 0.00 4.71 11.50 1.21E-07 2.45E 07 1.82E 05 2.24E 08 6.12E+03 1.39E+04 4.29E+03 1.28E+01 20 0.50 2.85 6.98 7.35E 08 1.48E 07 1.11E 05 1.36E 08 3.72E+03 '8.42E+03 2.61E+03 7.77E+00 20 0.99 0.64 1.56 1.64E 08 3.31E 08 2.47E 06 3.03E-09 8.45E+02 1.89E+03 5.98E+02 1.73E+00 20 1.49' O.05 0.13 1.35E-09 2.72E-09 2.03E 07 2.48E-10 8.77E+01 1.74E+02 6.74E+01 1.42E-01 20 1995 Graded Exercise

(

t e

StGto of Taxa 2 1995 Graded Exercise 06-December-1995 4

REAL TIME:

13:45 RELATIVE TIME

    • ee************************************************************:**H+06:45 OFFSITE RADIOLOGICAL SURVEY DATA
  • eee****************************************************************************

- - - - - - - - - - - METEOROLOGI CAL DATA - - - - - - - - - - - - - - - - - - - - - - RELEASE DATA - - - - - - - - - - - - - - -

WIND SPEED (MPH) 10.00 NOBLE GAS (CI/SEC) 3.864E+01 DELTA-T (DEG. F/50M)

-1.10 IODINE (CI/SEC) 3.145E-01 STABILITY CLASS (PASQUILL)

D PARTICULATE (CI/SEC) 4.439E-01 WIND DIRECTION (DEGREES) 250.0 TOTAL (CI/SEC) 3.940E+01 PLUME TRAVEL (MI) 3.732E+01 AVERAGE GAMMA (MEV/ DIS) 0.32 PLUME TRAILING EDGE (MI) 0.000E+00 AVERAGE BETA (MEV/ DIS) 0.21 1995 Graded Exercise LOCATION l

DOSE RATE l

AIR CONCENTRAT10N l AIR SAMPLE CPM l GROUND DEPOSITION l BACKGROUN DOWN DIST.

CLOSED OPEN GROSS GROSS NOBLE 10 DINE GROSS GROSS GROSS NET 8ACKGROUN WIND OFF WINDOW WINDOW 10 DINE PART.

GAS 131 10 DINE PART.

OEPOSIT.

GROUND COUNT DIST CENT.

DOSE R.

DOSE R.

ACTIVITY ACTIVITY ACTIVITY ACTIVITY COUNT R.

COUNT R.

COUNT R.

DEPOSIT.

RATE (MI)

(MI)

(MR/HR)

(MR/NR) (UCI/CC)

(UCI/CC)

(UCI/CC) (UCI/CC)

(CPM)

(CPM)

(CPM)

(UCI/M2)

(CPM) 0.5 0.00 145.17 405.79 6.17E 06 8.71E-06 7.87E 04 1.33E-06 3.10E+05 4.93E+05 3.35E+05 1.01E+03 20 0.04 88.05 246.13 3.74E-06 5.28E 06 4.77E 04 8.07E-07 1.88E+05 2.99E+05 2.03E+05 6.10E+02 20 O.08 19.65 54.92 8.35E 07 1.18E-06 1.07E 04 1.80E 07 4.20E+04 6.67E+04 4.53E+04 1.36E+02 20 f

0.12 1.61 4.51 6.85E 08 9.68E-08 8.74E-06 1.48E-08 3.47E+03 5.50F+03 3.74E+03 1.12E+01 20 1.0 0.00 65.63 183.45 2.70E 06 3.82E 06 3.56E-04 5.83E 07 1.36E+05 2.16E+05 1.47E+05 4.41E+02 20 0.07 39.81 111.27 1.64E-06 2.32E-06 2.16E-04 3.54E 07 8.25E+04 1.31E+05 8.91E+04 2.67E+02 20 O.15 8.88 24.83 3.66E-07 5.17E-07 4.82E 05 7.90E 08 1.84E+04 2.93E+04 1.99E+04 5.97E+01 20 0.22 0.73 2.04 3.00E-08 4.24E 08 3.96E 06 6.48E-09 1.53E+03 2.42E+03 1.65E+03 4.90E+00 20 1.5 0.00 38.53 107.70 1.59E-06 2.24E-06 2.09E 04 3.42E-07 7.98E+04 1.27E+05 8.62E+04 2.S9E+02 20 0.11 23.37 65.32 9.63E-07 1.36E 06 1.27E-04 2.08E 07 4.84E+04 7.70E+04 5.23E+04 1.57E+02 20 0.22 5.21 14.57 2.15E 07 3.03E-07 2.83E 05 4.63E-08 1.08E+04 1.72E+04 1.17E+04 3.50E+01 20 0.32 0.43 1.20 1.76E-08 2.49E-08 2.32E-06 3.80E 09 9.07E+02 1.43E+03 9.77E+02 2.87E+00 20 2.0 0.00 27.57 75.82 1.03E-06 1.52E-06 1.43E 04 2.17E-07 5.16E+04 8.57E+04 5.24E+04 1.57E+02 20

[

0.14 16.72 45.99 6.22E 07 9.19E 07 8.68E-05 1.32E-07 3.13E+04 5.20E+04 3.18E+04 9.55E+01 20 0.28 3.73 10.26 1.39E-07 2.05E 07 1.94E-05 2.94E 08 7.00E+03 1.16E+04 7.11E+03 2.13E+01 20 0.42 0.31 0.84 1.14E-08 1.68E 08 1.5?E-06 2.41E-09 5.93E+02 9.72E+02 6.02E+02 1.75E+00 20 3.0 0.00 15.97 43.93 6.04E-07 8.92E-07 8.29E-05 1.28E-07 3.04E+04 5.05E+04 3.09E+04 9.27E+01 20 0.20 9.69 26.64 3.66E-07

$.41E-07 5.03E-05 7.75E-08 1.84E+04 3.06E+04 1.87E+04 5.62E+01 20 0.39 2.16 5.95 8.17E-08 1.21E-07 1.12E 05 1.73E-08 4.13E+03 6.85E+03 4.20E+03 1.25E+01 20 0.59 0.18 0.49 6.71E-09 9.91E 09 9.21E-07 1.42E-09 3.57E+02 5.81E+02 3.63E+02 1.03E+00 20 1

4.0 0.00 11.52 31.14 4.02E-07 6.21E-07 5.71E 05 8.34E-08 2.02E+04 3.52E+04 1.93E+04 5.79E+01 20 0.25 6.99 18.89 2.44E-07 3.77E-07 3.46E-05 5.06E-08 1.23E+04 2.13E+04 1.17E+04 3.51E+01 20 0.50 1.56 4.21 5.44E-08 8.41E-08 7.73E-06 1.13E-08 2.76E+03 4.78E+03 2.63E+03 7.84E+00 20 0.75 0.13 0.35 4.47E-09 6.90E-09 6.35E-07 9.26E-10 2.45E+02 4.11E+02 2.34E+02 6.44E-01 20 r

Stato of Tsxas 1995 Graded Exercise 06-December-1995 REAL TIME:

13:45 RELATIVE TIME:

H+06:45 LOCATION l

DOSE RATE l

AIR CONCENTRATION l AIR SAMPLE CPM l GROUND DEPOSITION l BACKGROUN DOWN DIST.

CLOSED OPEN GROSS GROSS NOBLE 10 DINE GROSS GROSS GROSS NET 8ACKGROUN WIND OFF WINDOW WINDOW IODINE PART.

GAS 131 10 DINE PART.

DEPOSIT.

GROUND COUNT.

DIST CENT.

DOSE R.

DOSE R.

ACTIVITY ACTIVITY ACTIVITY ACTIVITY COUNT R.

COUNT R.

COUNT R.

DEPOSIT.

RATE (MI)

(MI)

(MR/NR)

(MR/NR) (UCl/CC)

(UCI/CC)

(UCl/CC)

(UCI/CC)

(CPM)

(CPM)

(CPM)

(UCI/M2)

(CPM) 5.0 0.00 9.10 24.16 2.95E 07 4.77E-07 4.31E-05 5.99E 08 1.48E+04 2.70E+04 1.33E+04 3.98E+01 20 0.30 5.52 14.65 1.79E 07 2.89E-07 2.61E-05 3.63E-08 9.01E+03 1.64E+04 8.06E+03 2.41E+01 20 0.60 1.23 3.27 3.99E 08 6.46E-08 5.83E 06 8.10E 09 2.03E+03 3.67E+03 1.81E+03 5.38E+00 20 0.89 0.10 0.27 3.27E 09 5.30E-09 4.78E 07 6.65E 10 1.85E+02 3.20E+02 1.67E+02 4.42E 01 20 6.0 0.00 7.21 19.15 2.37E 07 3.84E-07 3.41E 05 4.82E-08 1.19E+04 2.17E+04 1.07E+04 3.20E+01 20 0.34 4.38 11.62 1.44E 07 2.33E-07 2.07E 05 2.92E-08 7.25E+03 1.32E+04 6.49E+03 1.94E+01 20 0.69 0.98 2.59 3.21E-08 5.20E-08 4.62E-06 6.52E 09 1.63E+03 2.96E+03 1.46E+03 4.33E+00 20 1.03 0.08 0.21 2.63E 09 4.27E 09 3.79E 07 5.35E-10 1.53E+02 2.61E+02 1.38E+02 3.56E 01 20 7.0 0.00 6.27 16.33 1.92E 07 3.26E 07 2.83E 05 3.82E-08 9.68E+03 1.85E+04 8.10E+03 2.43E+01 20 0.38 3.80 9.91 1.16E 07 1.98E-07 1.72E 05 2.31E 08 5.88E+03 1.12E+04 4.92E+03 1.47E+01 20 0.77 0.85 2.21 2.60E-08 4.42E-08 3.83E-06 5.16E 09 1.33E+03 2.52E+03 1.11E+03 3.28E+00 20 1.15 0.07 0.18 2.13E 09 3.63E-09 3.14E-07 4.24E 10 1.27E+02 2.2SE+02 1.10E+02' 2.69E 01 20 8.0 0.00 5.32 13.85 1.65E 07 2.80E 07 2.40E 05 3.28E-08 8.31E+03 1.59E+04 6.95E+03 2.00E+01 20 0.42 3.23 8.40 1.00E 07 1.70E-07 1.45E-05 1.99E 08 5.05E+03 9.64E+03 4.23E+03 1.26E+01 20 0.85 0.72 1.87 2.23E 06 3.79E 08 3.25E 06 4.43E 09 1.14E+03 2.17E+03 9.58E+02 2.82E+00 20 1.27 0.06 0.15 1.83E 09 3.11E-09 2.66E 07 3.64E 10 1.12E+02 1.96E+02 9.70E+01 2.31E 01 20 9.0 0.00 4.85 12.38 1.40E-07 2.51E-07 2.08E 05 2.72E 08 7.08E+03 1.42E+04 5.54E+03 1.66E'+01 20 0.46 2.94 7.51 8.51E-08 1.52E 07 1.26E-05 1.65E 08 4.30E+03 8.64E+03 3.37E+03 1.01E+01 20 0.92 0.66 1.68 1.90E 08 3.40E-08 2.82E-06 3.69E-09 9.75E+02 1.94E+03 7.67E+02 2.24E+00 20 1.38 0.05 0.14 1.56E 09 2.79E-09 2.31E 07 3.03E-10 9.84E+01 1.78E+02 8.13E+01 1.84E 01 20 10.0 0.00 4.49 11.21 1.21E-07 2.30E 07 1.83E-05 2.29E-08 6.12E+03 1.30E+04 4.47E+03 1.34E+01 20 0.50 2.72 6.80 7.35E-08 1.39E-07 1.11E-05 1.39E 08 3.72E+03 7.91E+03 2.72E+03 8.10E+00 20 0.99 0.61 1.52 1.64E 08 3.11E-08 2.48E-06 3.11E 09 8.45E+02 1.78E+03 6.22E+02 1.81E+00 20 1.49 0.05 0.12 1.35E-09 2.55E-09 2.03E 07 2.55E-10 8.77E+01 1.64E+02 6.94E+01 1.48E-01 20 1995 Graded Exercise

SCcto of T xas 1995 Graded Exercise 06-December-1995 REAL TIME:

14:00 RELATIVE TIME:

H+07:00 oooo****************************************************************************

OFFSITE RADIOLOGICAL SURVEY DATA eeoo****************************************************************************


METEOROLOGICAL DATA----------


RELEASE DATA---------------

WIND SPEED (MPH) 10.00 NOBLE GAS (CI/SEC) 3.680E+01 DELTA-T (DEG. F/50M)

-1.10 IODINE (CI/SEC) 2.984E-01 STABILITY CLASS (PASQUILL)

D PARTICULATE (CI/SEC)

WIND DIRECTION (DEGREES) 250.0 TOTAL (CI/SEC) 4.102E-01 3.751E+01 PLUME TRAVEL (MI) 3.983E+01 AVERAGE GAMMA (MEV/ DIS) 0.31 PLUME TRAILING EDGE (MI) 0.000E+00

1. ERAGE BETA (MEV/ DIS) 0.21 1995 Graded Exercise LOCATION l

DOSE RATE l

AIR CONCENTRATION l AIR SAMPLE CPM l GROUND DEPOSITION l BACKGROUN DOWN DIST.

CLOSED OPEN GROSS GROSS NOBLE 10 DINE GROSS GROSS GROSS NET BACKGROUN WIND OFF WINDOW WINDOW IODINE PART.

GAS 131 10 DINE PART.

DEPOSIT.

GROUND COUNT DIST CENT.

DOSE R.

DOSE R.

ACTIVITY ACTIVITY ACTIVITY ACTIVITY COUNT R.

COUNT R.

COUNT R.

DEPOSIT.

RATE (MI)

(MI)

(MR/HR)

(MR/HR) (UCl/CC)

(UCI/CC)

(UCI/CC)

(UCl/CC)

(CPM)

(CPM)

(CPM)

(UCl/M2)

(CPM) 0.5 0.00 132.27 375.50 5.85E 06 8.05E 06 7.50E 04 1.29E-06 2.94E+05 4.56E+05 3.42E+05 1.03E+03 20 0.04 80.23 227.75 3.55E-06 4.88E 06 4.55E-04 7.79E-07 1.7BE+05 2.76E+05 2.07E+05 6.22E+02 20 0.08 17.90 50.82 7.92E 07 1.09E 06 1.01E-04 1.74E-07 3.98E+04 6.17E+04 4.63E+04 1.39E+02 20 0.12 1.47 4.17 6.50E-08 8.94E-08 8.33E 06 1.43E 08 3.29E+03 5.08E+03 3.81E+0'l 1.14E+01 20 1.0 0.00 59.80 169.76 2.57E 06 3.53E-06 3.39E 04 5.64E 07 1.29E+05 2.00E+05 1.50E+05 4.50E+02 20 0.07 36.27 102.96 1.56E 06 2.14E 06 2.06E-04 3.42E-07 7.83E+04 1.21E+05 9.09E+04 2.73E+02 20 0.15 8.09 22.97 3.47E-07 4.78E 07 4.59E 05 7.63E 08 1.75E+04 2.71E+04 2.03E+04 6.09E+01 20 0.22 -

0.66 1.89 2.85E-08 3.92E-06 3.77E-06 6.26E-09 1.45E+03 2.24E+03 1.68E+03 5.00E+00 20 1.5 0.00 35.10 99.66 1.51E 06 2.07E-06 1.99E-04 3.31E 07 7.58E+04 1.17E+05 8.79E+04 2.64E+02 20 0.11 21.29 60.45 9.13E-07 1.26E 06 1.21E 04 2.01E-07 4.60E+04 7.11E+04 5.33E+04 1.60E+02 20 0.22 4.75 13.49 2.04E 07 2.80E-07 2.69E-05 4.48E 08 1.03E+04 1.59E+04 1.19E+04 3.57E+01 20 0.32 0.39 1.11 1.67E 08 2.30E 2.21E 06 3.67E 09 8.61E+02 1.32E+03 9.97E+02 2.93E+00 20 2.0

,0,00 26.03 72.75 1.01E-06 1.43E-06 1.41E-04 2.18E-07 5.08E+04 8.08E+04 5.38E+04 1.62E+02 20 0.14 15.79 44.13 6.12E-07 8.65E-07 8.57E 05 1.32E-07 3.08E+04 4.90E+04 3.26E+04 9.80E+01 20 0.28 3.52 9.85 1.37E-07 1.93E-07 1.91E-05 2.95E-08 6.89E+03 1.09E+04 7.30E+03 2.19E+01 20 0.42 0.29 0.81 1.12E 08 1.58E-08 1.57E-06 2.42E-09 5.84E+02 9.17E+02 6.18E+02 1.79E+00 20 3.0 0.00 15.08 42.15 5.94E-07 8.40E-07 8.19E-05 1.28E 07 2.99E+04 4.76E+04 3.17E+04 9.51E+01 20 0.20 9.15 25.57 3.60E-07 5.09E-07 4.97E-05 7.77E-08 1.81E+04 2.88E+04 1.92E+04 5.77E+01 20 0.39 2.04 5.70 8.04E 08 1.14E-07 1.11E-05 1.73E 08 4.06E+03 6.45E+03 4.31E+03 1.29E+01 20 0.59 0.17 0.47 6.60E-09 9.33E-09 9.10E-07 1.42E-09 3.52E+02 5.48E+02 3.72E+02 1.06E+00 20 1

4.0 0.00 10.87 29.90 3.96E-07 5.85E-07 5.65E 05 8.37E-08 1.99E+04 3.31E+04 1.99E+04 5.96E+01 20 0.25 6.59 18.13 2.40E-07 3.55E-07 3.42E-05 5.08E 08 1.21E+04 2.01E+04 1.21E+04 3.61E+01 20 0.50 1.47 4.05 5.36E-08 7.92E-08 7.64E-06 1.13E-08 2.71E+03 4.50E+03 2.71E+03 8.06E+00 20 0.75 0.12 0.33 4.40E-09 6.50E-09 6.27E-07 9.30E 10 2.41E+02 3.88E+02 2.40E+02 6.62E 01 20

~

State of TIxas.

,1995 Graded Exercise 06-December-1995 REAL TIME:

14:00 RELATIVE TIME:

H+07:00 LOCATION l

DOSE RATE l

AIR CONCENTRATION l AIR SAMPLE CPM l GROUND DEPOSITION BACKGROUN

.........................................................................................................................l...........

DOWN DIST.

CLOSED OPEN GROSS GROSS NoeLE 10 DINE GROSS GROSS GROES NET BACKGROUN WIND OFF WINDOW WINDOW IODINE PART.

GAS 131 10 DINE PART.

DEPOSIT.

GROUND COUNT DIST CENT.

DOSE R.

DOSE R.

ACTIVITY ACTIVITY ACTIVITY ACTIVITY COUNT R.

COUNT R.

COUNT R.

OEPOSIT.

RATE (MI) (MI)

(MR/HR) (MR/NR) (UC1/CC)

(UCl/CC)

(UCl/CC) (UC!/CC)

(CPM)

(CPM)

(CPM)

(UCl/M2)

(CPH) 5.0 0.00 8.59 23.22 2.90E 07 4.49E-07 4.26E 05 6.02E 08 1.46E+04 2.54E+04 1.37E+04 4.10E+01 20 0.30-5.21 14.08 1.76E-07 2.73E-07 2.58E-05 3.65E 08 8.88E+03 1.54E+04 8.31E+03 2.49E+01 20 0.60 1.16 3.14 3.93E-08 6.08E 08 5.77E-06 8.15E 09 2.00E+03 3.46E+03 1.87E+03 5.55E+00 20 0.89 0.10 0.26 3.23E-09 4.99E 09 4.73E 07 6.69E 10 1.82E+02 3.02E+02 1.72E+02 4.56E 01 20 6.0 0.00 6.81 18.41 2.34E-07 3.61E 07 3.38E 05 4.85E 08 1.18E+04 2.05E+04 1.10E+04 3.30E+01 20 0.34 4.13 11.17 1.42E 07 2.19E 07 2.05E-05 2.94E-08 7.15E+03 1.24E+04 6.69E+03 2.00E+01 20 0.69 0.92 2.49 3.16E 08 4.89E-08 4.57E 06 6.56E-09 1.61E+03 2.79E+03 1.51E+03 4.47E+00 20 1.03 0.08 0.20 2.60E-09 4.02E-09 3.75E 07 5.38E 10 1.51E+02 2.47E+02 1.42E+02 3.67E 01 20 7.0 0.00 5.92 15.73 1.90E 07 3.07E 07 2.80E 05 3.85E-08 9.55E+03 1.74E+04 8.38E+03 2.51E+01 20 0.38 3.59 9.54 1.15E 07 1.86E-07 1.70E 05 2.34E-08 5.80E+03 1.06E+04 5.09E+03 1.52E+01 20 0.77 0.80 2.13 2.56E-08 4.16E-08 3.79E 06 5.211 09 1.31E+03 2.37E+03 1.15E+03 3.40E+00 20 1.15 0.07 0.17 2.11E-09 3.41E 09 3.12E-07 4.28E 10 1.26E+02 2.13E+02 1.13E+02 2.79E-01 20 8.0 0.00 5.02 13.34 1.63E 07 2.64E-07 2.38E-05 3.30E-08 8.20E+03 1.49E+04 7.19E+03 2.15E+01 20 0.42 3.05 8.09 9.87E-08 1.60E-07 1.44E 05 2.00E-08 4.98E+03 9.07E+03 4.37E+03 1.31E+01 20 0.85 0.68 1.80 2.20E-08 3.57E 08 3.22E 06 4.47E-09 1.13E+03 2.04E+03 9.91E+02 2.92E+00 20 1.27 0.06 0.15 1.81E 09 2.93E-09 2.64E-07 3.67E 10 1.11E+02 1.86E+02 9.97E+01 2.39E 01 20 9.0 0.00 4.59 11.95 1.39E-07 2.36E 07 2.07E 05 2.76E 08 7.00E+03 1.34E+04 5.75E+03 1.72E+01 20 f

0.46 2.78 7.25 8.42E 08 1.43E-07 1.26E 05 1.67E-08 4.26E+03 8.13E+03 3.50E+03 1.04E+01 20 0.92 0.62 1.62 1.88E-06 3.20E 08 2.80E*06 3.73E 09 9.65E+02 1.83E+03 7.95E+02 2.33E+00 20 1.38 0.05 0.13 1.54E 09 2.62E-09 2.30E 07 3.06E 10 9.76E+01 1.69E+02 8.37E+01 1.91E-01 20 10.0 0.00 4.26 10.87 1.20E 07 2.16E 07 1.83E 05 2.34E-08 6.08E+03 1.22E+04 4.66E+03 1.39E+01 20 0.50 2.58 6.59 7.30E-08 1.31E-07 1.11E-C5 1.42E 08 3.69E+03 7.43E+03 2.84E+03 8.45E+00 20 0.99 0.58 1.47 1.63E-08 2.92E-08 2.47E 06 3.16E 09 8.40E+02 1.67E+03 6.48E+02 1.89E+00 20 1.49 0.05 0.12 1.34E-09 2.40E 09 2.03E-07 2.60E 10 8.73E+01 1.56E+02 7.16E+01 1.55E-01 20 I

1995 Graded Exercise b

L

Stato of Tcxao

,1995 Graded Exercise 06-December-1995 REAL TIME:

14:15 RELATIVE TIME:

H+07:

ocooo******************************************************************15 OFFSITE RADIOLOGICAL SURVEY DATA oceoo***************************************************************************


METEOROLOGICAL DATA---------- ------------RELEASE DATA---------------

WIND SPEED (MPH) 10.00 NOBLE GAS (CI/SEC) 3.393E+01 DELTA-T (DEG. F/50M)

-1.10 IODINE (CI/SEC) 2.741E-01 STABILITY CLASS (PASQUILL)

D PARTICULATE (CI/SEC) 3.696E-01 WIND DIRECTION (DEGREES) 250.0 TOTAL (CI/SEC) 3.457E+01 PLUME TRAVEL (MI) 4.233E+01 AVERAGE GAMMA (MEV/ DIS) 0.30 PLUME TRAILING EDGE (MI) 0.000E+00 AVERAGE BETA (MEV/ DIS) 0.21 1995 Graded Exercise LOCATION l

DOSE RATE l

AIR CONCENTRATION l AIR SAMPLE CPM l GROUND DEPOSITION l BACKGROLAI DOWN DIST.

CLOSED OPEN GROSS GROSS NOBLE 10 DINE GROSS GROSS GROSS NET BACKGROUN WIND OFF WINDOW WINDOW 10 DINE PART.

GAS 131 10 DINE PART.

DEPOSIT.

GROUND COUNT DIST CENT.

DOSE R.

DOSE R.

ACTIVITY ACTIVITY ACTIVITY ACTIVITY COUNT R.

COUNT R.

COLMT R.

DEPOSIT.

RATE (MI)

(MI)

(MR/HR) (MR/HR) (UCI/CC) (UCI/CC) (UCI/CC) (UCI/CC)

(CPM)

(CPM)

(CPM)

(UC!/M2)

(CPM)

)

1 0.5 0.00 116.78 336.42 5.37E 06 7.25E-06 6.91E-04 1.20E-06 2.70E+05 4.10E+05 3.47E+05 1.04E+03 20 0.04 70.83 204.05 3.26E 06 4.40E 06 4.19E-04 7.29E-07 1.64E+05 2.49E+05 2.11E+05 6.32E+02 20 0.08 15.80 45.53 7.27E-07 9.81E 07 9.35E-05 1.63E 07 3.66E+04 5.56E+04 4.70E+04 1.41E+02 20 0.12 1.30 3.74 5.97E 08 8.06E-08 7.68E 06 1.33E-08 3.02E+03 4.58E+03 3.88E+03 1.16E+01 20 1.0 0.00 52.79 152.09 2.36E 06 3.18E-06 3.13E-04 5.27E 07 1.19E+05 1.80E+05 1.52E+05 4.57E+02 20 0.07 32.02 92.25 1.43E-06 1.93E 06 1.90E-04 3.20E-07 7.19E+04 1.09E+05 9.24E+04 2.77E+02 20 0.15 7.14 20.58 3.19E 07 4.30E-07 4.23E 05 7.13E 08 1.61E+04 2.44E+04 2.06E+04 6.19E+01 20 0.22 0.59 1.69 2.62E 08 3.53E 08 3.47E-06 5.85E-09 1.34E+03 2.02E+03 1.71E+03 5.08E+00 20 i

l l

1.5 0.00 30.99 89.29 1.38E-06 1.87E-06 1.84E-04 3.09E 07 6.96E+04 1.06E+05 8.94E+04 2.68E+02 20 j

0.11 18.80 54.15 8.39E-07 1.13E 06 1.11E 04 1.87E-07 4.22E+04 6.41E+04 5.42E+04 1.63E+02 20 0.22 4.19 12.08 1.87E-07 2.53E-07 2.48E 05 4.18E 08 9.43E+03 1.43E+04 1.21E+04 3.63E+01 20 0.32 0.34 0.99 1.54E 08 2.07E 08 2.04E 06 3.43E-09 7.93E+02 1.19E+03 1.01E+03 2.98E+00 20 2.0 0.00 23.71 67.32 9.57E-07 1.32E-06 1.35E 04 2.10E-07 4.82E+04 7.46E+04 5.51E+04 1.65E+02 20 0.14 14.38 40.83 5.81E-07 8.00E 07 8.17E-05 1.28E-07 2.92E+04 4.53E+04 3.34E+04 1.00E+02 20 0.28 3.21 9.11 1.30E 07 1.78E-07 1.82E-05 2.85E-08 6.54E+03 1.01E+04 7.47E+03 2.24E+01 20 0.42 0.26 0.75 1.06E-08 1.46E-08 1.50E-06 2.34E 09 5.55E+02 8.49E+02 6.32E+02 1.84E+00 20 3.0 0.00 13.74 39.00 5.64E-07 7.76E-07 7.80E-05 1.24E 07 2.84E+04 4.39E+04 3.24E+04 9.74E+01 20 0.20 8.33 23.66 3.42E-07 4.71E-07 4.73E-05 7.51E-08 1.72E+04 2.67E+04 1.97E+04 5.91E+01 20 0.39 1.86 5.28 7.63E 08 1.05E-07 1.06E-05 1.68E-08 3.86E+03 5.96E+03 4.41E+03 1.32E+01 20 0.59 0.15 0.43 6.26E-09 8.62E-09 8.66E-07 1.38E-09 3.35E+02 5.08E+02 3.80E+02 1.08E+00 20 4.0 0.00 10.26 28.69 3.89E-07 5.51E-07 5.58E-05 8.40E-08 1.96E+04 3.12E+04 2.04E+04 6.13E+01 20 0.25 6.22 17.40 2.36E-07 3.34E-07 3.38E-05 5.09E-08 1.19E+04 1.89E+04 1.24E+04 3.72E+01 20 0.50 1.39 3.88 5.27E-08 7.46E-08 7.55E-06 1.14E-08 2.67E+03 4.24E+03 2.78E+03 8.30E+00 20 0.75 0.11 0.32 4.32E-09 6.12E-09 6.19E-07 9.33E-10 2.38E+02 3.66E+02 2.47E+02 6.81E-31 20

Stcto of Texas

,1995 Graded Exercise 06-December-1995 REAL TIME:

14:15 RELATIVE TIME:

H+07:15 LOCATION l

DOSE RATE l

AIR CONCENTRATION l AIR SAMPLE CPM l GROUND DEPOSITION l BACKGROUN DOWN DIST.

CLOSED GPEN GROSS GROSS NOBLE ICI)!NE GROSS GROSS GROSS NET BACKGROUN WIND OFF WINDOW WINDOW 10 DINE PART.

GAS 131 IODINE PART.

DEPOSIT.

GROUND COUNT DIST CENT.

DOSE R.

DOSE R.

ACTIVITY ACTIVITY ACTIVITY ACTIVITY COUNT R.

COUNT R.

COUNT R.

DEPOSIT.

RATE (TI)

(MI)

(MR/NR)

(MR/NR) (UCI/CC)

(UCI/CC) (UCI/CC) (UCI/CC)

(CPM)

(CPM)

(CPM)

(UCl/M2)

(CPM) 5.0' O.00 8.11 22.29 2.86E 07-4.23E 07 4.21E 05 6.05E-08 1.44E+04 2.40E+04 1.41E+04 4.24E+01 20 0.30 4.92 13.52 1.73E 07 2.57E 07 2.55E-05 3.67E G8 8.74E+03 1.45E+04 8.57E+03 2.57E+01 20 0.60 1.10 3.02 3.87E 08 5.73E 08 5.70E-06 8.19E-09 1.97E+03 3.26E+03 1.93E+03 5.73E+00 20 0.89 0.09 0.25 3.18E 09 4.70E 09 4.68E 07 6.72E-10 1.80E+02 2.86E+02 1.77E+02 4.70E 01 20 6.0 0.00 6.43 17.67 2.30E 07 3.40E 07 3.34E-05 4.87E-08 1.16E+04 1.93E+04 1.14E+04 3.41E+01 20 0.34 3.90 10.72 1.40E-07 2.06E-07 2.02E 05 2.95E-08 7.04E+03 1.17E+04 6.90E+03 2.07E+01 20 0.69 0.87 2.39 3.11E-08 4.61E-08 4.52E 06 6.59E 09 1.59E+03 2.63E+03 1.56E+03 4.61E+00 20 1.03 0.07 0.20 2.56E 09 3.78E 09 3.71E 07 5.41E 10 1.49E*02 2.34E+02 1.46E+02 3.79E 01 20 7.0 0.00 5.59 15.12 1.87E 07 2.89E-07 2.77E-05 3.87E 08 9.41E+03 1.64E+04 8.67E+03 2.60E+01 20 0.38 3.39 9.17 1.13E 07 1.75E 07 1.68E 05 2.35E-08 5.72E+03 9.94E+03 5.2?E+03 1,58E+01 20 0.77 0.76 2.05 2.53E 08 3.91E 08 3.76E 06 5.24E-09 1.29E+03 2.23E+03 1.19E+03 3.52E+00 20 1.15 0.06 0.17 2.07E-09 3.21E 09 3.00E-07 4.30E 10 1.24E+02 2.02E+02 1.16E+02 2.89E-01 20 8.0 0.00 4.74 12.82 1.60E 07 2.48E 07 2.35E 05 3.33E-08 8.08E+03 1.41E+04 7.44E+03 2.23E+01 20 0.42 2.88 7.78 9.72E 08 1.51E 07 1.43E 05 2.02E-08 4.91E+03 8.54E+03 4.52E+03 1.35E+01 20 0.85 0.64 1.73 2.17E 08 3.36E 08 3.18E-06 4.50E 09 1.11E+03 1.92E+03 1.02E+03 3.02E+00 20 1.27 0.05 0.14 1.78E-09 2.76E-09 2.61E 07 3.69E 10 1.10E+02 1.76E+02 1.02E+02 2.48E 01 20 9.0 0.00 4.34 11.51 1.37E-07 2.22E-07 2.05E 05 2.78E 08 6.91E+03 1.26E+04 5.97E+03 1.79E+01 20 0.46 2.63 6.98 8.31E 08 1.35E 07 1.24E 05 1.69E 08 4.20E+03 7.65E+03 3.63E+03 1.08E+01 20 0.92 0.59 1.56 1.85E 08 3.01E 06 2.78E 06 3.TTE-09 9.53E+02 1.72E+03 8.25E+02 2.42E+00 20 1.38 0.05 0.13 1.52E 09 2.47E 09 2.28E 07 3.09E 10 9.66E+01 1.60E+02 8.61E+01 1.99E-01 20 10.0 0.00 4.03 10.49 1.19E-07 2.03E 07 1.82E 05 2.37E 08 6.01E+03 1.15E+04 4.86E+03 1.45E+01 20 0.50 2.44 6.36 7.23E 08 1.23E-07 1.10E 05 1.44E-08 3.66E+03 6.99E+03 2.96E+03 8.81E+00 20 0.99 0.55 1.42 1.61E-08 2.75E-08 2.46E 06 3.20E-09 8.31E+02 1.57E+03 6.75E+02 1.97E+00 20 1.49' O.04 0.12 1.32E-09 2.25E-09 2.02E-07 2.63E-10 8.66E+01 1.48E+02 7.38E+01 1.61E-01 20 1995 Graded Exercise

l Stato of Taxa 3

,1995 Graded Exercise 06-December-1995 i

REAL TIME:

14:30 l

ooooo********************************************* RELATIVE TIME:

H+07:30 OFFSITE RADIOLOGICAL SURVE j

ooooo********************************************Y DATA


METEOROLOGICAL DATA----------


RELEASE DATA---------------

WIND SPEED (MPH) 11.00 NOBLE GAS (CI/SEC) 3.146E+01 l

DELTA-T (DEG. F/50M)

-1.20 IODINE (CI/SEC) 2.532E-01 STABILITY CLASS (PASQUILL)

D PARTICULATE (CI/SEC) 3.298E-01 WIND DIRECTION (DEGREES) 250.0 TOTAL (CI/SEC) 3.204E+01 PLUME TRAVEL (MI) 4.509E+01 AVERAGE GAMMA (MEV/ DIS) 0.29 PLUME TRAILING EDGE (MI) 0.000E+00 AVERAGE BETA (MEV/ DIS) 0.20 1995 Graded Exercise LOCATION l

DOSE RATE l

AIR CONCENTRATION l AIR SAMPLE CPM l GROUND DEPOSITION 8ACKGROUN

.........................................................................................................................l...........

DOWN DIST.

CLOSE0 OPEN GROSS GROSS NOBLE 10 DINE GROSS GROSS GROSS NET BACKGROUN WIND OFF WINDOW WINDOW 100lNE PART.

GAS 131 IODINE PART.

OEPOSIT.

GROUND COUNT OIST CENT.

DOSE R.

DOSE R.

ACTIVITY ACTIVITY ACTIVITY ACTIVITY COUNT R.

COUNT R.

COUNT R.

DEPOSIT.

RATE (MI)

(MI)

(MR/NR) (MR/HR) (UCl/CC)

(UCI/CC) (UCI/CC)

(UC1/CC)

(CPM)

(CPM)

(CPM)

(UCl/M2)

(CPM) 0.5 0.00 94.32 275.53 4.51E-06 5.88E-06 5.83E-04 1.03E 06 2.27E+05 3.33E+05 3.48E+05 1.05E+03 20 0.04 57.21 167.12 2.74E-06 3.57E 06 3.53E 04 6.22E-07 1.38E+05 2.02E+05 2.11E+05 6.35E+02 20 0.08 12.77 37.29 6.11E-07 7.96E 07 7.89E 05 1.39E-07 3.07E+04 4.51E+04 4.72E+04 1.42E+02 20 0.12 1.05 3.06 5.01E 08 6.54E-08 6.47E-06 1.14E-06 2.54E+03 3.72E+03 3.89E+03 1.16E+01 20 1.0 0.00 42.64 124.57 1.98E-06 2.58E 06 2.64E-04 4.50E 07 9.96E+04 1.46E+05 1.53E+05 4.59E+02 20 0.07 25.86 75.55 1.20E 06 1.57E-06 1.60E-04 2.73E-07 6.04E+04 8.86E+04 9.27E+04 2.78E+02 20 0.15 5.77 16.86 2.68E 07 3.49E 07 3.57E 05 6.09E 08 1.35E+04 1.98E+04 2.07E+04 6.21E+01 20 0.22 0.47 1.38 2.20E-08 2.87E-08 2.93E 06 5.00E-09 1.13E+03 1.64E+03 1.72E+03 5.10E+00 20 1.5 0.00 25.03 73.13 1.16E-06 1.51E 06 1.

4 2.64E 07 5.84E+04 8.57E+04 8.97E+04 2.69E+02 20 0.11 15.18 44.35 7.05E-07 9.19E-07 9.

-05 1.60E 07 3.55E+04 5.20E+04 5.44E+04 1.63E+02 20 0.22 3.39 9.90 1.57E-07 2.05E 07 2.09E-05 3.57E-08 7.93E+03 1.16E+04 1.22E+04 3.64E+01 20 0.32 0.28 0.81 1.29E-08 1.68E 08 1.72E-06 2.93E 09 6.69E+02 9.72E+02 1.02E+03 2.99E+00 20 2.0 0.00 19.03 54.83 7.99E 07 1.08E-06 1.13E-04 1.79E-07 4.02E+04 6.11E+04 5.55E+04 1.67E+02 20 0.14 11.54 33.26 4.85E 07 6.55E 07 6.84E 05 1.08E 07 2.44E+04 3.71E+04 3.37E+04 1.01E+02 20 0.28 2.58 7.42 1.08E-07 1.46E 07 1.53E 05 2.42E 08 5.46E+03 8.29E+03 7.53E+03 2.26E+01 20 0.42 0.21 0.61 8.88E 09 1.20E 08 1.25E 06 1.98E-09 4.67E+02 6.99E+02 6.37E+02 1.85E+00 20 3.0 0.00 11.03 31.77 4.71E-07 6.36E 07 6.54E 05 1.05E 07 2.37E+04 3.60E+04 3.27E+04 9.81E+01 20 0.20 M9 19.27 2.85E-07 3.86E 07 3.96E-05 6.38E-08 1.44E+04 2.18E+04 1.98E+04 5.95E+01 20 0.39 1.49 4.30 6.37E-08 8.60E 08 8.85E-06 1.42E 08 3.22E+03 4.89E+03 4.44E+03 1.33E+01 20 0.59 0.12 0.35 5.23E-09 7.06E 09 7.26E 07 1.17E-09 2.83E+02 4.20E+02 3.83E+02 1.Q9E+00 20 t

t l

4.0 0.00 8.50 24.13 3.36E-07 4.63E Oi 4.83E 05 7.37E-08 1.69E+04 2.62E+04 2.07E+04 6.22E+01 20 0.25 5.16 14.64 2.04E-07 2.81E 07 2.93E 05 4.47E 08 1.03E+04 1.59E+04 1.26E+04 3.77E+01 20 0.50 1.15 3.27 4.54E-08 6.26E-08 6.53E-06 9.98E-09 2.31E+03 3.56E+03 2.82E+03 8.42E+00 20 0.75 0.09 0.27 3.73E-09 5.14E-09 5.36E-07 8.19E 10 2.08E+02 3.11E+02 2.50E+02 6.91E 01 20 r

4

Stcts of Texas

,1995 Graded Exercise 06-December-1995 REAL TIME:

14:30 RELATIVE TIME:

H+07:30 LOCATION l

DOSE RATE l

AIR CONCENTRATION l AIR SAMPLE CPM l GRous DEPOSITION l BACKGROUN i

DOWN DIST.

CLOSED GPEN GROSS GROSS NOBLE 10 DINE GROSS GROSS GROSS NET BACKGROUN WIND OFF WINDOW WIND 0W IG)!NE PART.

GAS 131 10 DINE PART.

DEPOSIT.

GROUND Ludi i O!ST CENT.

DOSE R.

DOSE R.

ACTIVITY ACTIVITY ACTIVITY ACTIVITY COUNT R.

COUNT R.

COUNT R.

DEPOSIT.

RATE l

(MI) (MI)

(MR/NR)

(MR/NR) (UCI/CC)

(UCI/CC) (UCI/CC) (UCI/CC)

(CPM)

(CPM)

(CPM)

(UCI/M2)

(CPM) 4 5.0 0.00 6.96 19.45 2.56E 07 3.62E 07 3.78E 05 5.52E 08 1.29E+04 2.05E+04 1.44E+04 4.31E+01 20 0.30 4.22 11.80 1.55E-07 2.20E 07 2.29E 05 3.35E 08 7.82E+03 1.25E+04 8.73E+03 2.62E+01 20 0.60 0.94 2.63 3.46E-08 4.90E 08 5.12E-06 7.46E 09 1.76E+03 2.79E+03 1.96E+03 5.84E+00 20 0.89 0.08 0.22 2.84E-09 4.02E 09 4.20E 07 6.13E-10 1.63E+02 2.48E+02 1.80E+02 4.79E-01 20 6.0 0.00 5.52 15.42 2.06E-07 2.91E 07 3.00E 05 4.44E 08 1.04E+04 1.65E+04 1.16E+04 3.47E+01 20 0.34 3.35 9.35 1.25E-07 1.77E-07 1.82E 05 2.69E-08 6.30E+03 1.00E+04 7.03E+03 2.11E+01 20 0.69 0.75 2.09 2.78E 08 3.94E 08 4.06E-06 6.00E 09 1.42E+03 2.25E+03 1.58E+03 4.70E+00 20 1.03 0.06 0.17 2.29E 09 3.24E 09 3.33E 07 4.93E 10 1.35E+02 2.03E+02 1.48E+02 3.86E 01 20 7.0 0.00 4.80 13.19 1.67E 07 2.48E-07 2.49E 05 3.54E-08 8.43E+03 1.40E+04 8.84E+03 2.65E+01 20 0.38 2.91 8.00 1.01E-07 1.50E-07 1.51E 05 2.14E-08 5.12E+03 8.51E+03 5.37E+03 1.61E+01 20 0.77 0.65 1.79 2.26E 08 3.35E 08 3.37E-06 4.79E 09 1.16E+03 1.92E+03 1.21E+03 3.59E+00 20 1.15 0.05 0.15 1.86E 09 2.75E 09 2.77E-07 3.93E-10 1.13E+02 1.76E+02 1.18E+02 2.96E 01 20 8.0 0.00 4.07 11.19 1.43E-07 2.12E-07 2.11E 05 3.04E 08 7.24E+03 1.20E+04 7.60E+03 2.27E+01 20 O.42 2.47 6.79 8.70E-08 1.29E-07 1.28E 05 1.84E 08 4.40E+03 7.31E+03 4.61E+03 1.38E+01 20 0.85 0.55 1.51 1.94E 06 2.88E-08 2.86E 06 4.11E 09 9.96E+02 1.65E+03 1.05E+03 3.08E+00 20 1

1.27 0.05 0.12 1.59E 09 2.36E 09 2.35E 07 3.37E 10 1.00E+02 1.54E+02 1.04E+02 2.53E 01 20 9.0 0.00 3.72 10.06 1.23E 07 1.90E 07 1.85E 05 2.55E 08 6.19E+03 1.08E+04 6.10E+03 1.83EN1 20 0.46 2.26 6.10 7.45E-08 1.15E 07 1.12E 05 1.54E 08 3.76E+03 6.55E+03 3.71E+03 1.11E+01 20 0.92 0.50 1.36 1.66E 08 2.57E 08 2.50E-06 3.45E-09 8.56E+02 1.48E+03 8.43E+02 2.47E+00 20 1.38 0.04 0.11 1.36E 09 2.11E 09 2.05E 07 2.83E 10 8.86E+01 1.40E+02 8.76E+01 2.03E 01 20 10.0 0.00 3.46 9.18 1.07E 07 1.74E-07 1.64E 05 2.17E 08 5.40E+03 9.84E+03 4.98E+03 1.49E+01 20 0.50 2.10 5.57 6.49E-08 1.05E-07 9.93E 06 1.32E 08 3.28E+03 5.98E+03 3.03E+03 9.03E+00 20 0.99 0.47 1.24 1.45E-08 2.35E-06 2.22E 06 2.94E-09 7.48E+02 1.35E+03 6.91E+02 2.01E+00 20 1.49 0.04 0.10 1.19E 09 1.93E-09 1.82E 07 2.41E 10 7.97E+01 1.29E+02 7.51E+01 1.65E-01 20 t

1995 Graded Exercise t

' ~

StEto of Tcxas 1995 Graded Exercise 06-December-1995 REAL TIME:

14:45 RELATIVE TIME:

H+07:45 eeooo***************************************************************************

OFFSITE RADIOLOGICAL SURVEY DATA

    • eoo***************************************************************************

METEOROLOGICAL DATA----------


RELEASE DATA---------------

WIND SPEED (MPH) 11.00 NOBLE GAS (CI/SEC) 2.933E+01 DELTA-T (DEG. F/50M)

-1.20 IODINE (CI/SEC) 2.352E-01 STABILITY CLASS (PASQUILL)

D PARTICULATE (CI/SEC)

WIND DIRECTION (DEGREES) 250.0 TOTAL (CI/SEC)

~

2.938E-01 2.986E+01 PLUME TRAVEL (MI) 4.785E+01 AVERAGE GAMMA (MEV/ DIS) 0.28 PLUME TRAILING EDGE (MI) 0.000E+00 AVERAGE BETA (MEV/ DIS) 0.20 1995 Graded Exercise LOCATION l

DOSE RATE l

AIR CONCENTRATION l AIR SAMPLE CPM l GROUND DEPOSITION l BACKGROUN DOWN DIST.

CLOSED OPEN GROSS Gross NOBLE 10 DINE GROSS GROSS GROSS NET SACKGROUN WIND OFF WINDOW WINDOW 10 DINE PART.

GAS 131 10 DINE PART.

DEPOSIT.

GROUNO COUNT DIST CENT.

DOSE R.

DOSE R.

ACTIVITY ACTIVITY ACTIVITY ACTIVITY COUNT R.

COUNT R.

COUNT R.

DEPOSIT.

RATE (MI)

(MI)

(MR/NR)

(MR/NR) (UCl/CC)

(UCI/CC) (UCI/CC) (UCI/CC)

(CPM)

(CPM)

(CPM)

(UCI/M2)

(CPM) 0.5 0.00 84.33 249.61 4.19E 06 5.24E-06 5.43E-04 9.69E-07 2.11E+05 2.97E+05 3.50E+05 1.05E+03 20

'{

0.04 51.15 151.40 2.54E-06 3.18E 06 3.29E-04 5.88E 07 1.28E+05 1.80E+05 2.12E+05 6.38E+02 20 l

0.08 11.41 33.78 5.67E-07 7.09E 07 7.35E 05 1.31E 07 2.86E+04 4.02E+04 4.74E+04 1.42E+02 20

{

0.12 0.94 2.77 4.66E-08 5.82E-08 6.03E 06 1.08E-08 2.36E+03 3.31E+03 3.91E+03 1.17E+01 20 1.0 0.00 38.12 112.85 1.84E-06 2.30E-06 2.46E 04 4.25E-07 9.25E+04 1.30E+05 1.54E+05 4.61E+02 20 0.07 23.12 68.45 1.12E 06 1.39E-06 1.49E 04 2.58E 07 5.61E+04 7.89E+04 9.31E+04 2.80E+02 20 0.15 5.16 15.27 2.49E-07 3.11E-07 3.33E-05 5.75E 08 1.25E+04 1.76E+04 2.08E+04 6.24E+01 20 1

0.22 0.42 1.25 2.04E-08 2.55E 08 2.73E-06 4.72E 09 1.05E+03 1.46E+03 1.73E+03 5.12E+00 20 1.5 0.00 22.38 66.25 1.08E 06 1.35E-06 1.44E 04 2.49E-07 5.43E+04 7.63E+04 9.01E+04 ~2.71E+02 20 0.11 13.58 40.18 6.54E-07 8.18E-07 8.75E 05 1.51E 07 3.29E+04 4.63E+04 5.47E+04 1.64E+02 20 0.22 3.03 8.97 1.46E-07 1.83E-07 1.95E-05 3.37E 08 7.37E+03 1.03E+04 1.22E+04 3.66E+01 20 0.*,2 0.25 0.74 1.20E-08 1.50E-08 1.60E-06 2.77E-09 6.23E+02 8.68E+02 1.02E+03 3.01E+00 20 l

2.0 0.00 16.91 49.40 7.39E-07 9.64E-07 1.05E 04 1.68E 07 3.72E+04 5.46E+04 5.60E+04 1.68E+02 20 (l

0.14 10.26 29.%

4.48E-07 5.85E-07 6.35E 05 1.02E-07 2.2SE+04 3.31E+04 3.39E+04 1.02E+02 20 l

0.28 2.29 6.69 9.99E 08 1.30E-07 1.42E 05 2.27E-08 5.05E+03 7.40E+03 7.59E+03 2.27E+01 20 0.42 0.19 0.55 8.20E 09 1.07E-08 1.16E-06 1.86E-09 4.33E+02 6.26E+02 6.41E+02 1.87E+00 20 3.0 0.00 9.80 28.62 4.35E 07 5.67E-07 6.06E 05 9.88E-08 2.19E+04 3.21E+04 3.30E+04 9.89E+01 20 0.20 5.94 17.36 2.64E-07 3.44E-07 3.68E 05 5.99E-08 1.33E+04 1.95E+04 2.00E+04 6.00E+01 20 0.39 1.33 3.87 5.88E-08 7.68E-08 8.20E 06 1.34E-08 2.98E+03 4.37E+03 4.48E+03 1.34E+01 20 0.59 0.11 0.32 4.83E-09 6.30E-09 6.73E-07 1.10E 09 2.63E+02 3.77E+02 3.86E+02 1.10E+00 20 L

4.0 0.00 7.51 21.62 3.08E-07 4.17E-07 4.45E 05 6.89E-08 1.55E+04 2.36E+04 2.10E+04 6.30E+01 20 0.25 4.55 13.11 1.87E-07 2.53E-07 2.70E-05 4.18E-08 9.43E+03 1.43E+04 1.27E+04 3.82E+01

' 20 0.50 1.02 2.93 4.17E-08 5.64E 08 6.02E 06 9.33E-09 2.12E+03 3.21E+03 2.86E*03 8.52E+00 20 O.75 0.08 0.24 3.43E-09 4.63E-09 4.94E-07 7.66E 10 1.92E+02 2.82E+02 2.53E+02 7.00E-01 20 l

l

1 a

Stato of Toxcs l

1995 Graded Exercise 06-December-1995 REAL TIME:

14:45 RELATIVE TIME:

H+07:45 LOCATION l

DOSE RATE l

Alt CONCENTRAfl0N l AIR SAMPLE CPM l GROUND DEPOSITION l BACKGROUN DOWN DIST.

CLOBED OPEN GROSS GROSS NOBLE 10 DINE GROSS GROSS GROSS NET BACKGROUN !

WIND OFF WINDOW WINDOW 10 DINE PART.

GAS 131 IODINE PART.

DEPOSIT.

GROUW COUNT DIST CENT.

DOSE R.

DOSE R.

ACTIVITY ACTIVITY ACTIVITY ACTIVITY COUNT R.

COUNT R.

COUNT R.

DEPOSIT.

RATE (MI) (MI)

(MR/MR)

(MR/NR) (UCI/CC) (UCl/CC) (UCI/CC)

(UC1/CC)

(CPM)

(CPM)

(CPM)

(UCI/M2)

(CPM) 5.0 0.00 6.34 18.00 2.43E-07 3.35E 07 3.60E 05 5.33E 08 1.22E+04 1.90E+04 1.47E+04 4.40E+01 20 0.30-3.84 10.92 1.47E 07 2.03E 07 2.18E 05 3.23E 08 7.42E+03 1.15E+04 8.90E+03 2.67E+01 20 0.60 0.86 2.44 3.28E 08 4.53E 08 4.87E-06 7.21E-09 1.67E+03 2.58E+03 2.00E+03 5.95E+00 20 0.89 0.07 0.20 2.69E 09 3.72E 09 4.00E 07 5.92E 10 1.56E+02 2.30E+02 1.83E+02 4.89E 01 20 6.0 0.00 5.03 14.27 1.95E-07 2.69E 07 2.85E-05 4.29E 08 9.84E+03 1.53E+04 1.18E+04 3.54E+01 20 0.34 3.05 8.65 1.18E-07 1.63E 07 1.73E 05 2.60E-08 5.97E+03 9.26E+03 7.17E+03 2.15E+01 20 0.69 0.68 1.93 2.64E 08 3.64E-08 3.86E-06 5.80E 09 1.35E+03 2.08E+03 1.61E+03 4.79E+00 20 1.03 0.06 0.16 2.17E 09 2.99E-09 3.17E-07 4.76E 10 1.29E+02 1.89E+02 1.51E+02 3.93E 01 20 7.0 0.00 4.53 12.66 1.64E 07 2.33E 07 2.46E-05 3.55E 08 8.29E+03 1.32E+04 9.06E+03 2.71E+01 20 0.38 2.75 7.68 9.97E 06 _1.41E 07 1.49E 05 2.15E 08 5.04E+03 8.02E+03 5.50E+03 1.65E+01 20 0.77 0.61 1.71 2.23E-08 3.15E 08 3.33E 06 4.80E-09 1.14E+03 1.80E+03 1.24E+03 3.67E+00 20 1.15 0.05 0.14 1.83E 09 2.59E-09 2.74E-07 3.94E 10 1.12E+02 1.67E+02 1.20E+02' 3.02E 01 20 8.0 0.00 3.84 10.74 1.41E 07 2.00E 07 2.09E 05 3.04E 08 7.12E+03 1.13E+04 7.78E+03 2.33E+01 20 O.42 2.33 6.51 8.56E-08 1.21E-07 1.27E-05 1.85E 08 4.33E+03 6.89E+03 4.73E+03 1.41E+01 20 l

0.85 0.52 1.45 1.91E 08 2.71E-08 2.83E-06 4.12E 09 9.81E+02 1.55E+03 1.07E+03 3.15E+00 20 1.27 0.04 0.12 1.57E 09 2.22E 09 2.32E-07 3.38E 10 9.89E+01 1.46E+02 1.06E+02 2.59E 01 20 9.0 0.00 3.51 9.66 1.21E 07 1.79E-07 1.82E-05 2.56E 08 6.10E+03 1.02E+04 6.26E+03 1.87E+01 20 0.46 2.13 5.86 7.33E 08 1.09E-07 1.11E 05 1.55E 08 3.71E+03 6.17E+03 3.81E+03 1.14E+01 20 0.92 0.48 1.31 1.64E 06 2.42E 08 2.47E 06 3.46E 09 8.43E+02 1.39E+03 8.65E+02 2.54E+00 20 1.38 0.04 0.11 1.34E-09 1.99E 09 2.03E-07 2.84E 10 8.75E+01 1.33E+02 8.94E+01 2.00E-01 20 10.0 0.00 3.26 8.82.1.05E 07 1.63E-07 1.62E 05 2.19E 08 5.32E+03 9.27E+03 5.12E+03 1.53E+01 20 0.50 1.98 5.35 6.39E-08 9.91E-08 9.83E 06 1.33E 08 3.23E+03 5.63E+03 3.11E+03 9.29E+00 20 0.99 0.44 1.19 1.43E 08 2.21E-06 2.19E-06 2.96E 09 7.37E+02 1.27E+03 7.10E+02 2.07E+00 20 1.49 0.04 0.10 1.17E-09 1.82E 09 1.80E-07 2.43E 10 7.89E+01 1.23E+02 7.66E+01 1.70E-01 20 1995 Graded Exercise L

a

State of Tcxnc 1995 Graded Exercise 06-December-1995 REAL TIME:

15:00 RELATIVE TIME:

H+08:00 1

eeeee***+***********************************************************************

OFFSITE RADIOLOGICAL SURVEY DATA

  • eoeo***************************************************************************

METEOROLOGICAL DATA----------


RELEASE DATA---------------

WIND SPEED (MPH) 11.00 NOBLE GAS (CI/SEC) 2.628E+01 DELTA-T (DEG. F/50M)

-1.20 IODINE (CI/SEC) 2.100E-01 4

STABILITY CLASS (PASQUILL)

D PARTICULATE (CI/SEC) 2.562E-01 WIND DIRECTION (DEGREES) 250.0 TOTAL (CI/SEC) 2.674E+01

)

PLUME TRAVEL (MI) 5.060E+01 AVERAGE GAMMA (MEV/ DIS) 0.27 PLUME TRAILING EDGE (MI) 0.000E+00 AVERAGE BETA (MEV/ DIS) 0.20 1995 Graded Exercise LOCATION l

DOSE RATE l

AIR CONCENTRATION l

AIR SAMPLE CPM l GROUND DEPOSITION l BACKGROUN DOWN DIST.

CLOSED OPEN GROSS GROSS NOBLE 10 DINE GROSS GROSS GROSS NET BACKGROUN WINO OFF WINDOW WINDOW IODINE PART.

GAS 131 IODINE PART.

' DEPOSIT.

GROUND COUNT DIST CENT.

DOSE R.

DOSE R.

ACTIVITY ACTIVITY ACTIVITY ACTIVITY COUNT R.

COUNT R.

COUNT R.

DEPOSIT.

RATE (MI)

(MI)

(MR/HR)

(MR/HR) (UCI/CC)

(UCI/CC)

(UCl/CC)

(UCI/CC)

(CPM)

(CPM)

(CPM)

(UCl/M2)

(CPM) 0.5 0.00 72.52 217.37 3.7&E-06 4.57E-06 4.87E 04 8.79E-07 1.88E+05 2.59E+05 3.51E+05 1.05E+03 20 0.04 43.99 131.84 2.27E-06 2.77E-06 2.95E 04 5.33E-07 1.14E+05 1.57E+05 2.13E+05 6.39E+02 20 0.08 9.82 29.42 5.07E-07 6.19E-07 6.59E-05 1.19E-07 2.55E+04 3.50E+04 4.75E+04 1.43E+02 20 0.12 0.81 2.41 4.166 08 5.08E 08 5.41E 06 9.76E-09 2.11E+03 2.89E+03 3.92E+03 1.17E+01 20 1.0 0.00 32.79 98.27 1.64E-06 2.00E-06 2.20E 04 3.85E 07 8.26E+04 1.13E+05 1.54E+05 4.62E+02 20 0.07 19.89 59.61 9.96E-07 1.22E-06 1.34E 04 2.34E-07 5.01E+04 6.88E+04 9.34E+04 2.80E+02 20 0.15 4.44 13.30 2.22E-07 2.71E 07 2.98E 05 5.21E-08 1.12E+04 1.54E+04 2.09E+04 6.26E+01 20 0.22 0.36 1.09 1.82E-08 2.23E 08 2.45E-06 4.28E-09 9.37E+02 1.28E+03 1.73E+03 5.14E+00 20 1.5 0.00 19.25 57.69 9.63E-07 1.18E-06 1.29E 04 2.26E 07 4.85E+04 6.66E+04 9.04E+04 2.'1E+02 20 0.11 11.67 34.99 5.84E-07 7.14E 07 7.84E-05 1.37E-07 2.94E+04 4.04E+04 5.48E+04

'. 65E+02 20 0.22 2.60 7.81 1.30E 07 1.59E-07 1.75E-05 3.06E 08 6.58E+03 9.03E+C~,

1.22E+04 3.67E+01 20 0.32 0.21 0.64 1.07E 08 1.31E-08 1.44E-06 2.51E 09 5.58E+02 7.59E+02 1.02E+03 3.01E+00 20 2.0 0.00 15.12 44.76 6.86E-07 8.58E 07 9.75E-05 1.59E-07 3.45E+04 4.86E+04 5.64E+04 1.69E+02 20 0.14 9.17 27.15 4.16E-07 5.21E-07 5.92E 05 9.61E-08 2.09E+04 2.95E+04 3.42E+04 1.03E+02 20 0.28 2.05 6.06 9.29E 08 1.16E-07 1.32E-05 2.15E-08 4.69E+03 6.59E+03 7.64E+03 2.29E+01 20 0.42 0.17 0.50 7.62E-09 9.54E-09 1.08E-06 1.76E-09 4.03E+02 5.60E+02 6.46E+02 1.88E+00 20 3.0 0.00 8.76 25.93 4.04E-07 5.05E 07 5.65E-05 9.33E-08 2.03E+04 2.86E+04 3.32E+04 9.96E+01 20 0.20 5.31 15.73 2.45E-07 3.07E 07 3.43E 05 5.66E-08 1.23E+04 1.74E+04 2.01E+04 6.04E+01 20 0.39 1.19 3.51 5.47E-08 6.84E 08 7.65E-06 1.26E-08 2.77E+03 3.89E+03 4.51E+03 1.35E+01 20 0.59 0.10 0.29 4.49E-09 5.61E-09 6.28E-07 1.04E 09 2.46E+02 3.38E+02 3.88E+02 1.11E+00 20 4.0 0.00 6.67 19.48 2.85E-07 3.72E-07 4.13E-05 6.48E 08 1.4*E+04 2.11E+04 2.12E+04 6.37E+01 20 0.25 4.04 11.82 1.73E 07 2.26E-07 2.50E-05 3.93E 08 8.71E+03 1.28E+04 1.29E+04 3.86'E+01 20 0.50 0.90 2.64 3.86E-08 5.04E-08 5.59E-06 8.77E-09 1.96E+03 2.87E+03 2.89E+03 8.61E+00 20,

0.75 0.07 0.22 3.17E-09 4.13E-09 4.58E-07 7.19E-10 1.79E+02 2.54E+02 2.55E+02 7.07E-01 20

StEta of T;xn2 1995 Graded Exercise 06-December-1995 REAL TIME:

15:00 RELATIVE TIME:

H+08:00 LOCATION l

DOSE RATE l

AIR CONCENTRATION l AIR SAMPLE CPM l GROUND DEPOSITION l BACKGROUN DOWN DIST.

CLOSED OPEN GROSS GROSS NOBLE 10 DINE GROSS GROSS GROSS NET SACKGROUN WIND OFF WINDOW WINDOW IODINE PART.

GAS 131 10 DINE PARI.

DEPOSIT.

GROUND COUNT DIST CENT.

DOSE R.

DOSE R.

ACTIVITY ACTIVITY ACTIVITY ACTIVITY COUNT R.

COUNT R.

COUNT R.

DEPOSIT.

RATE (Zl) (NI)

(MR/NR) (MR/HR) (UCI/CO) (UCl/CC) (UCI/CC) (UCI/CC)

(CPM)

(CPM)

(CPM)

(UCI/M2)

(CPM) 5.0 0.00 5.60 16.12 2.23E 07 3.02E 07 3.32E-05 4.98E-08 1.12E+04 1.71E+04 1.49E+04 4.47E+01 20 0.30 3.39 9.78 1.35E-07 1.83E 07 2.01E-05 3.02E 08 6.82E+03 1.04E+04 9.04E+03 2.71E+01 20 0.60 0.76 2.18 3.02E-08 4.08E-08 4.49E-06 6.74E-09 1.54E+03 2.33E+03 2.03E+03 6.05E+00 20 0.89 0.06 0.18 2.48E-09 3.35E-09 3.69E-07 5.53E 10 1.45E+02 2.10E+02 1.85E+02 4.96E 01 20 6.0 0.00 4.44 12.78 1.79E-07 2.43E 07 2.63E-05 4.01E 08 9.04E+03 1.37E+04 1.20E+04 3.59E+01 20 0.34 2.69 7.75 1.09E 07 1.47E-07 1.60E 05 2.43E 08 5.49E+03 8.35E+03 7.2SE+03 2.18E+01 20 0.69 0.60 1,73 2.43E 08 3.28E-08 3.56E-06 5.42E 09 1.24E+03 1.88E+03 1.64E+03 4.86E+00 20 1.03 0.05 0.14 1.99E-09 2.69E 09 2.92E 07 4.45E-10 1.20E+02 1.72E+02 1.53E+02 3.99E 01 20 7.0 0.00 4.13 11.72 1.56E 07 2.15E-07 2.35E 05 3.43E 08 7.87E+03 1.22E+04 9.27E+03 2.78E+01 20 0.38 2.50 7.11 9.46E 08 1.31E-07 1.42E 05 2.08E 08 4.7BE+03 7.41E+03 5.63E+03 1.68E+01 20 0.77 0.56 1.59 2.11E-06 2.92E 08 3.17E 06 4.64E-09 1.08E+03 1.67E+03 1.27E+03 3.76E+00 20 1.15 0.05 0.13 1.73E 09 2.39E-09 2.61E-07 3.81E 10 1.07E+02 1.55E+02 1.23E+02 3.08E 01 20 8.0 0.00 3.50 9.94 1.34E 07 1.85E-07 1.99E 05 2.94E-08 6.75E+03 1.05E+04 7.96E+03 2.38E+01 20 O.42 2.12 6.03 8.12E 08 1.12E-07 1.21E 05 1.78E 08 4.10E+03 6.37E+03 4.83E+03 1.45E+01 20 0.85 0.47 1.34 1.81E-08 2.50E 08 2.69E-06 3.98E-09 9.31E+02 1.44E+03 1.09E+03 3.23E+00 20 1.27 i).04 0.11 1.49E 09 2.05E 09 2.21E 07 3.27E 10 9.48E+01 1.36E+02 1.08E+02 2.65E 01 20 9.0 0.00 3.31 9.27 1.19E 07 1.69E-07 1.802 05 2.56E-08 6.00E+03 9.57E+03 6.44E+03 1.93E+01 20 0.46 2.01 5.62 7.21E-08 1.02E 07 1.09E-05 1.56E-06 3.65E+03 5.81E+03 3.91E+03 1.17E+01 20 0.92 0.45 1.25 1.61E-08 2.28E 08 2.44E 06 3.47E 09 8.29E+02 1.31E+03 8.89E+02 2.61E+00 20 1.38 0.04 0.10 1.32E-09 1.87E 09 2.00E 07 2.85E-10 8.64E+01 1.26E+02 9.13E+01 2.14E 01 20 10.0 0.00 3.08 8.47 1.04E 07 1.54E 07 1.60E 05 2.19E-08 5.24E+03 8.73E+03 5.28E+03 1.58E+01 20 0.50 1.87 5.14 6.29E-08 9.33E 08 9.72E-06 1.33E-08 3.18E+03 5.30E+03 3.21E+03 9.57E+00 20 0.99 0.42 1.15 1.40E-08 2.08E 08 2.17E-06 2.97E 09 7.26E+02 1.20E+03 7.31E+02 2.14E+00 20 1.49' O.03 0.09 1.15E-09 1.71E 09 1.78E-07 2.44E 10 7.80E+01 1.17E+02 7.84E+01 1.75E-01 20 1995 Graded Exercise fl ll T

l l

StCto of Tcxns 1995 Graded Exercise 06-December-1995 REAL TIME:

15:15 RELATIVE TIME:

H+08:15 ocooo***************************************************************************

OFFSITE RADIOLOGICAL SURVEY DATA ooooo***************=***********************************************************

1 i


METEOROLOGICAL DATA---------- ------------RELEASE DATA---------------

WIND SPEED (MPH) 11.00 NOBLE GAS (CI/SEC) 2.366E+01 DELTA-T (DEG. F/50M)

-1.30 IODINE (CI/SEC) 1.885E-01 STABILITY CLASS (PASQUILL)

D PARTICULATE (CI/SEC) 2.217E-01 WIND DIRECTION (DEGREES) 252.0 TOTAL (CI/SEC) 2.407E+01 l

PLUME TRAVEL (MI) 5.336E+01 AVERAGE GAMMA (MEV/ DIS) 0.26 i

PLUME TRAILING EDGE (MI) 0.000E+00 AVERAGE BETA (MEV/ DIS) 0.20 l ________________________________________

1995 Graded Exercise LOCATION l

DOSE RATE l

AIR CONCENTRATION l AIR SAMPLE CPM l GROUND DEPOSITION l 8ACKGROUN DOWN DIST.

CLOSED OPEN GROSS GROSS NOBLE 10 DINE GROSS GROSS GROSS NET BACKGROUN WIND OFF WINDOW WINDOW IODINE PART.

GAS 131 IODINE PART.

DEPOSIT.

GROUND COUNT DIST CENT.

DOSE R.

DOSE R.

ACTIVITY ACTIVITY ACTIVITY ACTIVITY COUNT R.

COUNT R.

COUNT R.

DEPOSIT.

RATE (MI)

(MI)

(MR/HR)

(MR/NR) (UCI/CC) (UCI/CC) (UCI/CC) (UCI/CC)

(CPM)

(CPM)

(CPM)

(UCI/M2)

(CPM) i l

k 0.5 0.00 62.73 190.27 3.36E-06 3.95E O6 4.38E-04 8.00E-07 1.69E+05 2.24E+05 3.51E+05 1.06E+03 20 l

0.04 38.05 115.40 2.04E 06 2.40E-06 2.66E-04 4.86E 07 1.03E+05 1.36E+05 2.13E+05 6.40E+02 20 0.08 8.49 25.75 4.55E-07 5.35E 07 5.93E-05 1.08E 07 2.29E+04 3.03E+04 4.76E+04 1.43E+02 20 0.12 0.70 2.11 3.73E 08 4.39E 08 4.87E-06 8.89E-09 1.90E+03 2.51E+03 3.92E+03 1.17E+01 20 j

1.0 0.00 28.36 86.02 1.47E 06 1.73E 06 1.98E-04 3,51E-07 7.41E+04 9.82E+04 1.54E+05 4.63E+02 20 0.07 17.20 52.17 8.94E-07 1.05E 06 1.20E-0".

2.13E 07 4.50E+04 5.96E+04 9.35E+04 2.81E+02 2C 0.15 3.84 11.64 1.99E-07 2.35E 07 2.68E-05 4.75E 08 1.00E+04 1.33E+04 2.09E+04 6.26E+01 20 0.22 0.32 0.96 1.64E 08 1.93E-08 2.20E-06 3.90E-09 8.43E+02 1.11E+03 1.73E+03 5.14E+00 20 1.5 0.00 16.65 50.50 8.65E 07 1.02E-06 1.16E-04 2.06E-07 4.35E+04 5.76E+04 9.04E+04 2.72E+02 20 0.11 10.10 30.63 5.24E 07 6.17E-07 7.06E-05 1.25E-07 2.64E+04 3.5DE+04 5.49E+04 1.65E+02 20 0.22 2.25 6.83 1.17E-07 1.38E 07 1.58E-05 2.79E-08 5.91E+03 7.81E+03 1.23E+04 3.67E+01 20 0.32 0.18 0.56 9.60E-09 1.13E-08 1.29E 06 2.29E 09 5.03E+02 6.60E+02 1.02E+03 3.02E+00 20 l

2.0 0.00 13.00 38.98 6.13E-07 7.49E-07 8.74E 05 1.44E-07 3.08E+04 4.24E+04 5.66E+04 1.70E+02 20 0.14 7.89 23.64 3.72E-07 4.54E-07 5.30E-05 8.72E-08 1.87E+04 2.57E+04 3.43E+04 1.03E+02 20 L

0.28 1.76 5.27 8.29E 08 1.01E-07 1.18E 05 1.95E-08 4.19E+03 5.75E+03 7.68E+03 2.30E+01 20 l

0.42 0.14 0.43 6.80E-09 8.32E 09 9.71E-07 1.60E-09 3.62E+02 4.91E+02 6.49E+02 1.89E+00 20 l

3.0 0.00 7.53 22.58 3.61E 07 4.41E-07 5.06E-05 8.46E 08 1.82E+G*

2.50E+04 3.33E+04 1.00E+02 20 0.20 4.57 13.70 2.19E-07 2.67E 07 3.07E 05 5.13E-08 1.10E+04 1.51E+04 2.02E+04 6.07E+01 20 0.39 1.02 3.06 4.88E-08 5.97E-08 6.85E-06 1.15E-08 2.47E+03 3.40E+03 4.53E+03 1.35E+01 20 1

0.59 0.08 0.25 4.01E 09 4.90E-09 5.62E-07 9.40E 10 2.22E+02 2.97E+02 3.90E+02 1.11E+00 20 4.0 0.00 5.96 17.65 2.65E 07 3.31E 07 3.85E-05 6.12E-08 1.33E+04 1.88E+04 2.14E+04 6.42E+01 20 0.25 3.62 10.70 1.61E 07 2.01E-07 2.33E-05 3.71E 08 8.09E+03 1.14E+04 1.30E+04 3.90E+01 20 0.50 0.81 2.39 3.58E 08 4.49E 08 5.21E-06 8.28E 09 1.82E+03 2.56E+03 2.91E+03 8.69E+00 20 4

0.75 0.07 0.20 2.94E 09 3.68E-09 4.27E-07 6.79E 10 1.68E+02 2.28E+02 2.58E+02 7.13E 01 20 l

l i

Stcta of Tcxas

,1995 Graded Exercise 06-December-1995 REAL TIME:

15:15 RELATIVE TIME:

H+08:15 LOCATION l

DOSE RATE l

AIR CONCENTRATION l AIR SAMPLE CPM l GROUND DEPOSITION l BACKGROUN DOWN DIST.

CLOSED OPEN GROSS GROSS NOBLE IODINE GROSS GROSS GROSS NET BACKGROUN WIND OFF WINDOW WINDOW 10DIhE PART.

GAS 131 IODINE PART.

DEPOSIT.

GROUND COUNT f

DIST CENT.

DOSE R.

DOSE R.

ACTIVITY ACTIVITY ACTIVITY ACTIVITY COUNT R.

COUNT R.

COUNT R.

DEPOSIT.

RATE (MI) (MI)

(MR/NR) (MR/NR) (UCI/CC)

(UCI/CC) (UCI/CC) (UCI/CC)

(CPM)

(CPM)

(CPM)

(UCI/M2)

(CPM) l 5.0 0.00 4.97 14.53 2.06E 07 2.69E 07 3.00E-05 4.68E 08 1.04E+04 1.52E+04 1.51E+04 4.52E+01 20 0.30 3.02 8.81 1.25E 07 1.63E-07 1.87E 05 2.84E-08 6.30E+03 9.26E+03 9.16E+03 2.74E+01 20 0.60 0.67 1.97 2.79E 08 3.64E 08 4.17E-06 6.33E 09 1.42E+03 2.08E+03 2.06E+03 6.12E+00 20 0.89 0.06 0.16 2.29E-09 2.99E-09 3.42E 07 5.20E 10 1.35E+02 1.89E+02 1.87E+02 5.02E 01 20 6.0 0.00 3.94 11.52 1.66E 07 2.17E 07 2.44E 05 3.76E 08 8.35E+03 1.23E+04 1.21E+04 3.64E+01 20 0.34 2.39 6.99 1.00E-07 1.31E 07 1.48E 05 2.28E 08 5.07E+03 7.46E+03 7.37E+03 2.21E+01 20 0.69 0.53 1.56 2.24E-08 2.93E 06 3.30E 06 5.09E 09 1.15E+03 1.68E+03 1.66E+03 4.92E+00 20 1.03 0.04 0.13 1.84E 09 2.41E-09 2.71E-07 4.18E 10 1.13E+02 1.56E+02 1.55E+02 4.04E-01 20 7.0 0.00 3.64 10.50 1.43E-07 1.94E-07 2.16E-05 3.20E-08 7.23E+03 1.10E+04 9.43E+03 2.83E+01 20 0.38 2.21 6.37 8.69E 08 1.18E-07 1.31E-05 1.94E 08 4.39E+03 6.68E+03 5.73E+03 1.'/1E+01 20 0.77 0.49 1.42 1.94E 08 2.63E-08 2.93E 06 4.33E-09 9.95E+02 1.51E+03 1.29E+03 3.83E+00 20 1.15 0.04 0.12 1.59E 09 2.16E-09 2.40E 07 3.56E 10 1.00E+02 1.42E+02 1.25E+02 3.14E-01 20 8.0 0.00 3.09 8.90 1.23E-07 1.67E 07 1.83E 05 2.75E-08 6.21E+03 9.45E+03 8.10E+03 2.43E+01 20 O.42 1.87 5.40 7.46E-08 1.01E 07 1.11E-05 1.67E 08 3.77E+03 5.74E+03 4.92E+03 1.47E+01 20 0.85 0.42 1.20 1.66E 08 2.25E 08 2.48E-06 3.72E 09 8.57E+02 1.30E+03 1.11E+03 3.20E+00 20 1.27 0.03 0.10-1.37E 09 1.85E 09 2.04E-07 3.05E 10 8.87E+01 1.25E+02 1.10E+02 2.70E 01 20 9.0 0.00 3.02 8.57 1.13E-07 1.56E 07 1.72E-05 2.48E-08 5.69E+03 8.84E+03 6.60E+03 1.98E+01 20 0.46 1.83 5.20 6.84E-08 9.46E 08 1.04E 05 1.50E 06 3.46E+03 5.37E+03 4.01E+03 1.20E+01 20 0.92 0.41 1.16 1.53E 08 2.11E-08 2.32E-06 3.35E 09 7.88E+02 1.21E+03 9.11E+02 2.68E+00 20 1.38 0.03 0.10 1.25E-09 1.73E 09 1.91E 07 2.75E-10 8.30E+01 1.18E+02 9.31E+01 2.20E 01 20 10.0 0.00 2.91 8.13 1.02E 07 1.45E-07 1.58E-05 2.20E-08 5.15E+03 8.22EC3 5.44E+03 1.63E+01 20

' O.50 1.76 4.93 6.19E-08 8.79E 08 9.60E 06 1.33E 08 3.13E+03 4.99E+03 3.31E+03 9.87E+00 20 0.99 0.39 1.10 1.38E 08 1.ME 08 - 2.14E-06 2.98E-09 7.15E+02 1.13E+03 7.54E+02 2.20E+00 20 1.49 0.03 0.09 1.13E-09 1.61E 09 1.76E-07 2.44E 10 7.70E+01 1.11E+02 8.02E+01 1.81E-01 20 4

1995 Graded Exercise 1

i l

Stcto of T xas

,1995 Graded Exercise 06-December-1995 REAL TIME:

15:30 REL H+08:30 occoo************************************************ATIVE TIME:

OFFSITE RADIOLOGICAL SURVEY DATA ooooo***************************************************************************


METEOROLOGICAL DATA---------- ------------RELEASE DATA---------------

WIND SPEED (MPH) 12.00 NOBLE GAS (CI/SEC) 2.142E+01 l

DELTA-T (DEG. F/50M)

-1.30 IODINE (CI/SEC) 1.700E-01 STABILITY CLASS (PASQUILL)

D PARTICULATE (CI/SEC) 1.915E-01 WIND DIRECTION (DEGREES) 252.0 TOTAL (CI/SEC) 2.179E+01 l

PLUME TRAVEL (MI) 5.636E+01 AVERAGE GAMMA (MEV/ DIS) 0.25 PLUME TRAILING EDGE (MI) 0.000E+00 AVERAGE BETA (MEV/ DIS) 0.19 1995 Graded Exercise l

LOCATION l

DOSE RATE l

AIR CONCENTRATION l AIR SAMPLE CPM l GROUND DEPOSITION l BACKGROUN 6....................

DOWN DIST.

CLOSED OPEN GROSS GROSS NOBLE 10 DINE GROSS GROSS Gross NET BACKGROUN WIND OFF WINDOW WINDOW IODINE PART.

GAS 131 ICDINE PART.

DEPOSIT.

GROUW COUNT DIST CENT.

DOSE R.

DOSE R.

ACTIVITY ACTIVITY ACTIVITY ACTIVITY COUNT R.

COUNT R.

COUNT R.

(EPOSIT.

RATE (MI)

(MI)

(MR/NR) (MR/ht) (UCI/CC)

(UCI/CC)

(UCI/CC)

(UCI/CC)

(CPM)

(CPM)

(CPM) f JC!/M2)

(CPM) i 0.5 0.00 50.04 153.49 2.78E 06 3.13E 06 3.64E-04 6.72E-07 1.40E+05 1.77E+05 3.50E+05 1.V5E+03 20 l

0.04 30.35 93.10 1.69E 06 1.90E 06 2.21E 04 4.07E 07 8.48E+04 1.07E+05 2.12E+05 6.37E+02 20 0.08 6.77 20.77 3.76E 07 4.24E-07 4.92E 05 9.09E 08 1.89E+04 2.40E+04 4.73E+04 1.42E+02 20 i

0.12 0.56 1.71 3.09E 06 3.48E-08 4.04E-06 7.46E-09 1.57E+03 1.99E+03 3.90E+03 1.17E+01 20 i

1.0 0.00 22.63 69.40 1.22E-06 1.37E 06 1.65E 04 2.95E-07 6.13E+04 7.77E+04 1.53E+05 4.61E+02 20 0.07 13.72 42.09 7.39C-07 8.33E-07 9.90E 05 1.79E 07 3.72E+04 4.72E+04 9.30E+04 2.79E+02 20 j

0.15 3.06 9.39 1.65E 07 1.86E 07 2.23E-05 3.99E 08 8.31E+03 1.05E+04 2.00E+04 6.23E+01 20 0.22 0.25 0.77 1.35E 08 1.53E 08 1.83E-06 3.27E 09 7.01E+02 8.83E+02 1.72E+03 5.12E+00 20 1.5 0.00 13.28 40.74 7.15E-07 8.06E-07 9.66E 05 1.73E-07 3.60E+04 4.56E+04 9.00E+04 2.70E+02 20 0.11 8.06 24.71 4.34E-07 4.89E 07 5.86E-05 1.05E 07 2.18E+04 2.77E+04 5.46E+04 1.64E+02 20 0.22 1.80 5.51 9.68E 08 1.09E 07 1.31E-05 2.34E 08 4.89E+03 6.19E+03 1.22E+04 3.66E+01 20 0.32 0.15 0.45 7.94E-09 8.95E-09 1.07E-06 1.92E 09 4.20E+02 5.27E+02 1.02E+03 3.00E+00 20 2.0 0.00 10.31 31.28 5.04E-07 5.94E-07 7.21E 05 1.20E-07 2.54E+04 3.36E+04 5.64E+04 1.69E+02 20 0.14 6.25 18.97 3.06E-07 3.60E-07 4.38E-05 7.28E 08 1.54E+04 2.04E+04 3.42E+04 1.03E+02 20 0.28 1.40 4.23 6.82E-08 8.04E 06 9.76E-06 1.62E-08 3.45E+03 4.57E+03 7.65E+03 2.29E+01 20 0.42 0.11 0.35 5.60E-09 6.60E 09 8.01E-07 1.33E-09 3.02E+02 3.93E+02 6.47E+02 1.88E+00 20 3.0 0.00 5.97 18.12 2.97E 07 3.50E 07 4.18E-05 7.07E-08 1.49E+04 1.98E+04 3.32E+04 9.97E+01 20 0.20 3.62 10.99 1.80E-07 2.12E-07 2.53E-05 4.29E-06

  • 9.07E+03 1.20E+04 2.02E+04 6.05E+01 20 1

0.39 0.81 2.45 4.02E 08 4.73E 08 5.66E-06 9.57E 09 2.04E+03 2.70E+03 4.51E+03 1.35E+01 20 0.59 0.07 0.20 3.30E-09 3.88E 09 4.64E-07 7.85E-10 1.86E+02 2.40E+02 3.89E+02 1.11E+00 20 4.0 0.00 4.70 14.09 2.17E 07 2.65E 07 3.16E-05 5.08E-08 1.09E+04 1.50E+04 2.14E+04 6.42E+01 20 0.25 2.85 8.55 1.31E 07 1.61E 07 1.92E-05 3.08E-08 6.63E+03 9.11E+03 1.30E+04 3.89E+01 20 0.50 0.64 1.91 2.93E 08 3.59E-08 4.28E-06 6.88E-09 1.49E+03 2.05E+03 2.91E+03 8.69E+00 20 0.75 0.05 0.16 2.41E 09 2.94E-09 3.51E-07 5.65E-10 1.41E+02 1.87E+02 2.57E+02 7.13E-01 20 fI 4

Stsnto of Tcxns 1995 Graded Exercise 06-December-1995 REAL TIME:

15:30 RELATIVE TIME:

H+08:30 LOCATION l

DOSE RATE l

AIR CONCENTRATION l AIR SAMPLE CPM l GROUND DEPOSITION l BACKGROUN DOWN DIST.

CLOSED OPEN GROSS GROSS NOBLE 10 DINE GROSS GROSS GROSS NET BACKGROUN WIND OFF WINDOW WINDOW 10 DINE PART.

GAS 131 100!NE PART.

DEPOSIT.

GROUND COUNT DIST CENT.

DOSE R.

DOSE R.

ACTIVITY ACTIVITY ACTIVITY ACTIVITY COUNT R.

COUNT R.

COUNT R.

DEPOSIT.

RATE (MI)

(MI)

(MR/NR) (MR/NR) (UCI/CC) (UCI/CC) (UCI/CC)

(UCl/CC)

(CPM)

(CPM)

(CPM)

(UCl/M2)

(CPM) 5.0 0.00 4.08 12.06 1.75E 07 2.20E-07 2.63E-05 4.05E 08 8.84E+03 1.25E+04 1.51E+04 4.54E+01 20 0.30 -

2.47 7.32 1.06E 07 1.33E-07 1.60E-05 2.46E 08 5.37E+03 7.56E+03 9.19E+03 2.75E+01 20 0.60 0.55 1.63 2.37E-08 2.97E-08 3.56E-06 5.48E-09 1.21E+03 1.70E+03 2.07E+03 6.14E+00 20 j

0.89 0.05 0.13 1.95E-09 2.44E 09 2.92E 07 4.50E 10 1.18E+02 1.58E+02 1.88E+02 5.04E 01 20 6.0 0.00 3.23 9.56 1.41E-07 1.77E 07 2.09E-05 3.26E-08 7.11E+03 1.00E+04 1.22E+04 3.65E+01 20 0.34 1.%

5.80 8.55E-08 1.07E-07 1.27E-05 1.98E 08 4.32E+03 6.09E+03 7.39E+03 2.21E+01 20 0.69 0.44 1.29 1.91E-06 2.39E 08 2.82E-06 4.41E 09 9.80E+02 1.37E+03 1.67E+03 4.94E+00 20 1.03 0.04 0.11 1.57E 09 1.96E 09 2.32E 07 3.62E-10 9.88E+01 1.31E+02 1.55E+02 4.06E-01 20 7.0 0.00 2.97 8.67 1.21E 07 1.59E-07 1.84E-05 2.76E 08 6.12E+03 9.00E+03 9.49E+03 2.84E+01 20 0.38 1.80 5.26 7.36E-08 9.63E-08 1.11E-05 1.67E 08 3.72E+03 5.47E+03 5.7G+03 1.72E+01 20 0.77 0.40 1.17 1.64E-06 2.15E-08 2.49E 06 3.73E 09 8.46E+02 1.24E+03 1.30E+03 3.85E+00 20 1.15 0.03 0.10 1.35E-09 1.76E 09 2.04E 07 3.06E-10 8.78E+01 1.20E+02 1.25E+02 3.16E-01 20 8.0 0.00 2.52 7.35 1.04E 07 1.36E-07 1.56E 05 2.37E 08 5.26E+03 7.73E+03 8.15E+03 2.44E+01 20 0.42 1.53 4.46 6.32E-08 8.27E-08 9.45E-06 1.44E-08 3.20E+03 4.70E+03 4.95E+03 1.48E+01 20 0.85 0.34 0.99 1.41E 08 1.84E 08 2.11E-06 3.20E 09 7.29E+02 1.06E+03 1.12E+03 3.30E+00 20 1.27 0.03 0.08 1.16E 09 1.51E 09 1.73E 07 2.63E 10 7.82E+01 1.06E+02 1.10E+02 2.71E-01 20 9.0 0.00 2.44 7.04 9.50E-08 1.29E-07 1.45E-05 2.12E 08 4.80E+03 7.30E+03 6.67E+03 2.00E+01 20 0.46 1.48 4.27 5.76E-08 7.81E-08 8.80E-06 1.29E 08 2.92E+03 4.44E+03 4.05E+03 1.21E+01 20 0.92 0.33 0.95 1.29E-08 1.74E 08 1.96E-06 2.87E-09 6.66E+02 1.01E+03 9.20E+02 2.70E+00 20 1.38 0.03 0.08 1.05E-09 1.43E 09 1.61E-07 2.36E 10 7.31E+01 1.01E+02 9.39E+01 2.22E 01 20 10.0 0.00 2.43 6.90 8.87E 08 1.23E 07 1 38E 05 1.95E-08 4.48E+03 6.97E+03 5.53E+03 1.65E+01 20 0.50 1.47 4.18 5.38E-08 7.45E 08 8.38E-06 1.18E-06 2.73E+03 4.23E+03 3.36E+03 1.00E+01 20 0.99 0.33 0.93 1.20E-08 1.66E 08 1.87E-06 2.64E 09 6.24E+02 9.60E+02 7.66E+02 2.24E+00 20 1.49 0.03 0.08 9.86E-10 1.36E 09 1.53E-07 2.17E 10 6.96E+01 9.72E+01 8.12E+01 1.84E-01 20 1995 Graded Exercise

i 1

Stcte of Tcx s j

1 1

!,1995 Graded Exercise l

06-December-1995 REAL TIME:

15:45 RELATIVE TIME:

H+08:45 oooeo***************************************************************************

i OFFSITE RADIOLOGICAL SURVEY DATA l

  • eoeo***************************************************************************

1


METEOROLOGICAL DATA----------


RELEASE DATA---------------

WIND SPEED (MPH) 12.00 NOBLE GAS (CI/SEC) 1.950E+01 DELTA-T (DEG. F/50M)

-1.40 IODINE (CI/SEC) 1.543E-01 STABILITY CLASS (PASQUILL)

C PARTICULATE (CI/SEC) 1.656E-01 i

WIND DIRECTION (DEGREES) 252.0 TOTAL (CI/SEC) 1.982E+01 PLUME TRAVEL (MI) 5.937E+01 AVERAGE GAMMA (MEV/ DIS) 0.24 i

PLUME TRAILING EDGE (MI) 0.000E+00 AVERAGE BETA (MEV/ DIS) 0.19 1995 Graded Exercise LOCATION l

DOSE RATE l

AIR CONCENTRATION l AIR SAMPLE CPM l GROUND DEPOSITION l BACKGROUN

.................................................................................................................................... j DOWN DIST.

CLOSED OPEN GROSS GROSS NOBLE IODINE GROSS GROSS

, GROSS NET BACKGROUN j WIND OFF WINDOW WINDOW 10 DIE PART.

GAS 131 10 DINE PART.

DEPOSIT.

GROUND COUNT

)

DIST CENT.

DOSE R.

DOSE R.

ACTIVITY ACTIVITY ACTIVITY ACTIVITY COUNT R.

COUNT R.

COUNT R.

DEPOSIT.

RATE (MI)

(MI)

(MR/HR) (NR/HR) (UCI/CC)

(UCI/CC)

(UCl/CC)

(UCl/CC)

(CPM)

(CPM)

(CPM)

(UCI/M2)

(CPM) 0.5 0.00 0.00 0.00

<LLD

<LLD (LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20

)

0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01 (LLD 20 1.0 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 0.00 0.00 0.00

<LLD (LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 1.5 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20

'O.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 2.0 Q.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 O.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 3.0 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 0.00 0.00 0.00

<LLD

<LLD

<tLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 4.0 0.00 0.00 0.00 (LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01 (LLD 20 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20

[

0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20

Stzte of Trxas

,1995 Graded Exercise 06-December-1995 REAL TIME:

15:45 RELATIVE TIME:

H+08:45 LOCATION l

DOSE RATE l

AIR CONCENTRATION l AIR SAMPLE CPM l GROUND DEPOSITION l BACKGROUN i

DOWN DIST.

CLOSED OPEN GROSS GROSS NOBLE ICCINE GROSS GROSS GROSS NET BACKGROUN WIND OFF WINDOW WINDOW 10 DINE PART.

GAS 131 ICCINE PART.

DEPOSIT.

GROUND COUNT DIST CENT.

Dose R.

DOSE R.

ACTIVITY ACTIVITY ACTIVITY ACTIVITY COUNT R.

COUNT R.

COUNT R.

DEPOSIT.

RATE (MI) (MI)

(MR/NR)

(MR/NR) (UCl/CC) (UCl/CC) (UCI/CC) (UCI/CC)

(CPM)

(CPM)

(CPM)

(UCI/M2)

(CPM) 5.0 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01

'2.00E+01'

<LLD 20 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 l

0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 6.0 0.00 0.00 0.M

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 r

0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 7.0 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20

)

0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01' <LLD 20 8.0 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 O.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 0.00 0.00 0.00

<LLD

<LLD (LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 9.0 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD-20 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 10.0 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 1

1995 Graded Exercise i

\\

Stato of Texcs 1995 Graded Exercise 06-December-1995 REAL TIME:

16:00 RELATIVE TIME:

eeeee*************************************************************H+09:00 OFFSITE RADIOLOGICAL SURVEY DATA


METEOROLOGICAL DATA---------- ------------RELEASE DATA---------------

WIND SPEED (MPH) 12.00 NOBLE GAS (CI/SEC) 1.785E+01 DELTA-T (DEG. F/SOM)

-1.40 IODINE (CI/SEC) 1.407E-01 STABILITY CLASS (PASQUILL)

C PARTICULATE (CI/SEC) 1.438E-01 WIND DIRECTION (DEGREES) 252.0 TOTAL (CI/SEC) 1.814E+01 PLUME TRAVEL (MI) 6.237E+01 AVERAGE GAMMA (MEV/ DIS) 0.23 PLUME TRAILING EDGE (MI) 0.000E+00 AVERAGE BETA (MEV/ DIS) 0.19 1995 Graded Exercise LOCATION l

DOSE RATE l

AIR CONCENTRATION l

AIR SAMPLE CPM l GROUND DEPOSITION l BACKGROUN DOWN DIST.

CLOSED OPEN GROSS GROSS NOBLE 10 DINE GROSS GROSS GROSS NET BACKGROUN WIND OFF WINDOW WINDOW IODINE PART.

GAS 131

.10 DINE PART.

DEPOSIT.

GROUND COUNT DIST CENT.

DOSE R.

DOSE R.

ACTIVITY ACTIVITY ACTIVITY ACTIVITY COUNT R.

COUNT R.

COUNT R.

DEPOSIT.

RATE (MI)

(MI)

(MR/HR)

(MR/NR) (UCI/CC)

(UCI/CC)

(UCI/CC) (UCI/CC)

(CPM)

(CPM)

(CPM)

(UCI/M2)

(CPM) 0.5 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+Q

<LLD 20 O.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 1.0 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 1.5 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 l'

2.0 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 1

0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 0.00 0.00

.0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 3.0 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 0.00 0.00 0.00 (LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E401 2.00E+01

<LLD 20 4.0 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 r

6

l l

State of Tcxso I1995 Graded Exercise 06-December-1995 REAL TIME:

16:00 RELATIVE TIME:

H+09:00 LOCATION l

DOSE RATE l

A!R CONCENTRATION l AIR SAMPLE CPM l GROUND DEPOSITION l BACKGROUN DOWN DIST.

CLOSED GPEN GROSS GROSS NOSLE 10 DINE GROSS GROSS GROSS NET SACKGROUN WIND OFF WINDOW WINDOW 1(BINE PART.

GAS 131 ICDINE PART.

DEPOSIT.

GROUND COUNT DIST CENT.

DOSE R.

DOSE R.

ACTIVITY ACTIVITY ACTIVITY ACTIVITY CCRNIT R.

COUNT R.

COUNT R.

DEPOSIT.

RATE (MI)

(NI)

(MR/NR)

(MR/NR) (UCI/CC)

(UCl/CC) (UCI/CC) (UC!/CC)

(CPM)

(CPM)

(CPM)

(UCl/N2)

(CPM) 5.0 0.00 0.00 0.00

<LLD

<tLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20

{

0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 6.0 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 l

l 7.0 0.00 0.00 0.00

<LLD

. LLD

<LLD.

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 1

0.00,

0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.,00E+01 2.00E+01 2.00E+01

, LLD 20 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 1

(

8.0 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 9.0 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 l

10.0 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 0.00 0.00 0.00

<LLD

<LLD

<LLD

<LLD 2.00E+01 2.00E+01 2.00E+01

<LLD 20 1995 Graded Exerc'ise l

l

. _