Forwards Application for Amend to License NPF-69,revising TS Section 4.6.2, Depressurization Sys - Suppression Pool
ML20101D745
Person / Time
Site: Nine Mile Point 
Issue date: 03/15/1996
From: Abbott R
NIAGARA MOHAWK POWER CORP.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20101D747 List:
References
NMP2L-1617, NUDOCS 9603210166
Download: ML20101D745 (2)


Text

-. -. - -.

M V NIAGARA R UMOHAWK NBAGARA MOHAWK POWER CORPORATION /NINE MILE POINT NUCLEAR STATION, P.O. BOX 63. LYCOMING, N.Y.13003/TEL (315) 349-1812 FAX (315) 349-4417 RICHARD B. ABBOTT Z"w March 15,1996 NMP2L 1617 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555 RE:

Nine Mile Point Unit 2 Docket No. 50-410 NPF-69 Gentlemen:

Niagara Mohawk Power Corporation (NMPC) hereby transmits an Application for Amendment to Nine Mile Point Unit 2 (NMP2) Operating License NPF-69. Also enclosed are the proposed changes to the Technical Specifications (TS) set forth in Appendix A to the above mentioned license. A marked copy of the current Technical Specification pages, showing the proposed changes, is provided in Attachment B. Supporting information and analyses demonstrating that the proposed changes involve no significant hazards consideration pursuant to 10CFR50.92 are included as Attachment C.

)

NMPC proposes to revise TS Section 4.6.2, "Depressurization Systems - Suppression Pool."

The proposed revisions will extend the time interval for performing the containment drywell-to-suppression chamber bypass leakage test from 18 months to an interval corresponding to that required for the Containment Integrated Ixak Rate Test. In a separate action, NMPC has submitted an Application for an Amendment which would revise the Technical Specifications to incorporate Option B of 10CFR50 Appendix J. The Appendix J revision would result in changing the required frequency of the Integrated leak Rate Test. The amendment requested by this submittal and the Appendix J revisions are independent actions, j

however, the proposed Technical Specification changes have been developed to ensure consistency.

NMPC has determined that drywell-to-suppression chamber bypass leakage from pathways, other than through the drywell floor penetrations containing the suppression chamber vacuum i

breakers, is negligible based on engineering evaluations, design features and fabrication specifications for drywell-to-suppression chamber components. Performing the drywell-to-suppression chamber bypass leak test every 18 months (refueling outage) results in excessive and unnecessary pressurization cycles of the containment. The bypass leak test also limits the flexibility of outage planning as personnel are not permitted to work inside the containment while it is pressurized for bypass leakage testing. In order to support the change to the frequency of the bypass leak test, a surveillance test involving testing of the bypass leakage path containing the suppression chamber vacuum breakers is also proposed. This surveillance test will incorporate acceptance criteria that is a small fraction of the Technical Specification allowable leakage, and will be performed each refueling outage that the bypass leak test is not performed.

Mn001 1 0 9603210166 960315 3

0' PDR ADOCK 05000410 P

PDR

\\

i Page 2 f

NMPC is requesting that this license amendment be issued by September 11,1996. This will support implementation prior to the upcoming Nine Mile Point Unit 2 refueling outage.

This date also allows coordination of this amendment request and the proposed change incorporating Option B of 10CFR50 Appendix J.

Pursuant to 10CFR50.91(b)(1), NMPC has provided a copy of this license amendment request and the associated analysis regarding no significant hazards consideration to the appropriate state representative.

Very truly yours, Y$

d Richard B. Abbott Vice President - Nuclear Generation RBA/AFZ/Imc Attachments xc:

Regional Administrator, Region I Mr. B. S. Norris, Senior Resident Inspector Mr. D. S. Hood, Senior Project Manager, NRR Mr. J. P. Spath NYSERDA 2 Empire Plaza, Suite 1901 Albany, NY 12223-1253 Records Management