ML20101C819

From kanterella
Jump to navigation Jump to search
Advises That Info Re Improvements Suggested by Generic Ltr 84-23, Reactor Vessel Water Level Instrumentation in Bwrs, Provided in 830823 Response to Request for Addl Info Re TMI Item II.F.2
ML20101C819
Person / Time
Site: Limerick  
Issue date: 12/17/1984
From: Kemper J
PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC
To: Eisenhut D
Office of Nuclear Reactor Regulation
References
CON-#185-736, TASK-2.F.2, TASK-TM GL-84-23, OL, NUDOCS 8412210208
Download: ML20101C819 (2)


Text

-A c.1, a PHILADELPHIA ELECTRIC COMPANY 2301 MARKET STREET P.O. BOX 8699 PHILADELPHI A. PA.19101 (215)841-4502 VIC E-PR ESID E NT December 17, 1984

....................c" Mr. D. G. Eisenhut, Director Docket Nos.:

50-352

. Division of Licensing 50-353 Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Conmission Washington, D.C. 20555

Subject:

Limerick Generating Station, Units 1 and 2 Reactor Vessel Water Level Instrumentation in BWR's-(Generic Letter No. 84-23)

References:

1)

Letter, J. S. Kemper to A. Schwencer " Limerick Generating Station, Units 1 and 2 Response to Core Performance Branch Request-for Additional Information Concerning TMI Item II.F.2 (SLI-8211 and SLI-8218)", August 23, 1983.

2)

Safety Evaluation Report Related to the Operation of Limerick Generating Station Units 1 and 2 NUREG-0991 Supplement No. 2, October 1984.

File:

GOVT 1-1 (NRC)

Dear Mr. Eisenhut:

Information addressing the three improvements suggested by Generic Letter No. 84-23 was previously submitted by reference 1 letter. This information, which addressed each of the potential improvement categories listed in the generic letter, has also been reviewed and approved by the NRC staff as docunented in the reference 2 safety evaluation (St.bsection 4.4.7).

Copies of these docunents are attached for your convenience.

Sincerely,

~

DFC/gra/12038404 3

Y 8412210200 841217 PDR ADOCK 05000352 Il 1

P PDR L

J

1.

w

-.t s

cc: Judge Helen F. Hoyt (w/ enclosure)

Judge derry Harbour (w/ enclosure)

Judge Richard F. Cole (w/ enclosure)

Judge Christine N. Kohl (w/ enclosure)

Judge Gary J. Edles (w/ enclosure) dudge Reginald L. Gotchy (w/ enclosure)

Troy B. Conner, Jr., Esq.

(w/ enclosure)

Ann P. Hodgdon, Esq.

(w/ enclosure)

Mr. Frank R. Romano (w/ enclosure)

Mr. Robert L. Anthony (w/ enclosure)

Ms. Phyllis Zitzer (w/ enclosure)

Charles W. Elliot, Esq.

(w/ enclosure)

Zori G. Ferkin, Esq.

(w/ enclosure)

Mr. Thcmas Gerusky (w/ enclosure)

Director, Penna. Emergency (w/ enclosure)

Management Agency Angus R. Love, Esq.

(w/ enclosure)

David Wersan, Esq.

(w/ enclosure)

Robert J. Sugarman, Esq.

(w/ enclosure)

Martha W. Bush, Esq.

(w/ enclosure)

Spence W. Perry, Esq.

(w/ enclosure) day M. Gutierrez, Esq.

(w/ enclosure)

Atomic Safety & Licensing (w/ enclosure)

Appeal Board Atcmic Safety & Licensing (w/ enclosure)

Board Panel Docket & Service Section (w/ enclosure)

Mr. James Wiggins (w/ enclosure)

Mr. Tinothy R. S. Campbell (w/ enclosure)

~

w\\

.a.

.--.L-*.-.'--.-.....

.f

.-- - - ! ? ~ +

^'

J-8.

s

f., ' -

f9 3.- fn

' I gi

'O' se PHILADELPHIA ELECTRIC COMPANY

. 5 ERVl C E

  • Y 2301 MARKET STREET iQ

'n \\)

st g

P.O. BOX 8699 1001 19tf1 PHIL'ADELPHIA. PA.19:01 (215)841 45o2 JOHN S. KEMPER v oc E+R E 53 D C NT

.L August 23, 1983 Mr. A.

Schwencer, Ch ie f-Licensing Branch No. 2 Division of Licensing U.

S.

Nuclear Regulatory Commission Washington, D.C.

20555

Subject:

Limerick Cenerating Station, Units I and 2 Response to Core Performance Branch Request for Additional Information Concerning THI Item II.F.2 (SLI-82il and SLI-8218)

Re fe rence :

PECO and NRC Conference Call dated July 19, 1983 File:

COVT l-1 (NRC)

Dear Mr. Schwencer:

As requested by the Core Performance Branch Reviewer in the reference conference call, the attached additional information provides a description,of the Limerick specific review of the reactor water' level instrumentation, a discussion of the improvements to this instrumentation, and a discussion of the need for additional inadequate core cooling instrumentation.

l l

Sincerely, t

S/<7L l.

RJS/gra/16 Copy to:

See Attached Service List hb C/

l

\\

l.

l

$N -;

,- q.,. n :. 2

.~..:.

=

. - +. -

c i.

cc: Judge Lawrence Brenner (w/ enclosure)

Judge Richard F. Cole (w/ enclosure)

(w/ enclosure)

Judge Peter A. Morris

. Troy B. Conner, Jr., Esq.

(w/ enclosure)

' Ann P. Ho_dgdon, Esq.

(w/ enclosure)

Mr. Frank R. Romano

- (w/ enclosure)

Mr. Robert L. Anthony (w/ enclosure)

LMr. Marvin I. Lewis (w/ enclosure).

' Judith A._Dorsey, Esq.

(w/ enclosure)

Charles W. Elliott, Esq.

(w/ enclosure)

Jacqueline I. Ruttenberg (w/ enclosure)

-Thomas Y. Au, Esq.

(w/ enclosure)

Mr. Thomas Gerusky (w/ enclosure)

Director, Pennsylvania Emergency-Management Agency (w/ enclosure)

Mr. Steven P. Hershey (w/ enclosure)

Angus Love, Esq.

(w/ enclosure)

Mr. Joseph H. White, III (w/ enclosure)

David Wersan, Esq.

(w/ enclosure)

Robert J. Sugarman, Esq.-

(w/ enclosure)

Martha W. Bush, Esq.

(w/ enclosure)

Spence W. Perry, Esq.

(w/ enclosure)

Atomic Safety and Licensing Appeal Board (w/ enclosure)

Atomic Safety and Licensing Board Panel (w/ enclosure)

Docket and Service Section (w/ enclosure)

~

bec:

V.

S.

Boyer J.

S.

Kemper

-E.

C. Kistner /J.

L.

Allen R.

A.-Mulford R.

H.

Logue E.

F.

Sproat R.'J. Stipcevich' G.

D.

Edwards J.,L Phillabaum (2)

NES Chron

Y "... ',i r

- M. +. -.;.- %...i.. u-h=AN

~

~

'~

^

- = - -

L ELECTRICAL. ENGINEERING DIVISION

'N3-1, 2301 Market Street

?

August 18, 1983

SUBJECT:

\\ Item II.F.2 of NUREG-0737

. Response to NRC Request for Information Limerick Generating Station The BWR Owners' Group has submitted two reports to the Nuclear

' Regulatory ~ Commission (NRC) to respond to. the. requirements of item

= II.F.2 of NUREG-0737, " Clarification of 'TMI Action Plan Requirements."

.The first report, SLI-8211, " Review of BWR Reactor Vessel Water Level

' Measurement-Systems," analyzes the current water level measurement system and concludes that there are problems with the instrument design in some plants.

The second report, SLI-8218, " Inadequate Core Cooling

' Detection in Boiling Water Reactors," places the reactor water level' instrument problems into perspective through the use of a probabilistic

' risk assessment.SLI-8218'also examines if any new instruments must be added to measure the adequacy of core cooling..

This report concludes that:

l a.)

Reactor water level measurement conclusively indicates i;

the adequacy of core cooling.

I b.). The risk of core melt associated with failures of the existing reactor water. level instrumentation is small.

b This risk can be made smaller with improvements in the.

l existing instrumentation and by the implementation of J.

water level validation techniques.

l c.)

There are several new' instruments that are viable for, measuring the adequacy of core cooling. However, the addition of new instrumentation is not? cost beneficial.

t b

Philadelphia Electric. Company has participated in the BWR Owners' i -

~ Group during the development of these reports and agrees with the generic' conclusions contained in them.

The following is..a description of the Limerick specific review of the reactor water level instrumenta-tion'and a discussion of the' improvements to this instrumentation.

.The Limerick Generating Station (LGS) reactor pressure' vessel (RPV)

~

water level measuring system has -four (4) divisions of instrumentation.

L f The instrumentation uses cold -reference legs and differential pressure measuring devices.- These devices are connected to the vessel through parallel linesi that is, the reference leg and the variable. leg sensing i

lines have the ~same vertical drop- (12 feet at LGS) in the drywell. We calso. include -in our design analog transmitters and electronic trip units.

The; LGS design does not include mechanical trip units or Yarway heated reference column devices.

e e

i

.l2 f."..-9.h..-.h5& &5

.a. ;N..

.5Y C. -?d - ~

~~

~~

c....

-2 August 18, 1983 Prior to the issuance of the S.

Levy,. Inc., study SLI-8211, L.

" Review of Reactor Vessel Water Level Measurement Systems", Philadelphia Electric Co.. reviewed the LGS RPV water level measuring system and found.

that some of the instrument lines were non-parallel.

. e have made W

piping changes to our system using existing penetrations to ensure that the lines are as parallel as possible, thus reducing the errors in level indications caused by elevated'drywell temperature.

When SLI-8211 was issued, we reviewed the study and examined the concerns and made improvements when. they were justified. for LGS.

We have~ added additional instrumentation. to monitor reference le'g temperature as an aid to detecting a potential reference leg boil-off condition.

As we have described in previous communications, the reference -leg temperature monitoring system consists. of one. dual element, type "T", 0.5%, surface-mounted thermocouple installed on each of the reference legs.

The outputs of these thermocouples provide inputs to the Emergency Response Facility Data System (ERFDS).

In the ERFDS, these signals are used to generate displays useful to the reactor operator in following the LGS emergency procedures and identifying the potential for reference leg boil-off.

Displays and information available on. the EFEDS include reference leg temperature (both individual temperatures and trend displays), compensated water level, and a reactor pressure vs. reference leg temperature plot useful in determining conditions. leading to reference leg boiling.'

Section 5.4 of SLI-8211 summarizes the major areas of concern with the water level instrumentation for the various BWR designs reviewed.

The concerns and how they relate to LGS are as follows:

Concern 1:

Yarway temperature compensated reference legs could flash at

' intermediate pressures during the course of plant cooldown.

Response 1 (LGS):

f At LGS, we do not have' Yarway temperature compensated reference-I legs.

The LGS design utilizes cold reference legs. Therefore, Concern l'

1 is not applicable'to LGS.

Concern 2:

l

' Position of orifices in both reference and variablo legn.

j I

I1,. - - - - - - -.. -

i c.:'.

.,==_.----..u.

-i-~?:

- +-

' t ',*

, August 18, 1983

. Response 2'(LGS):

SLI-8211 recommends ' moving,the instrument line flow orifices as close to the containment penetration as possible to prevent erratic level indications under boil-off and flashing conditions. We feel that it would be inappropriate to make such.a modification at LGS.

The following statement taken from SLI-8211, page 6-36, the second para-graph, provides the appropriate context for consideration of this concern:

"It is apparent that considerable effort.and expense would be

. incurred to implement this change in an existing plant, but imple-mentation on a plant in early construction might be a nominal.

burden.

On the other hand, the existing analytic basis that supports the motivation for the change is limited to a sample calculation resulting from an approximate analysis. Therefore, it would not be appropriate ~ to make the change, if considerable expense results, without further detailed study of the phenomena and the particular installation."

At the time this study was completed and reviewed by PECO, LGS Unit I was approximately 85% designed and/or fabricated; now that -figure has increased to 93%.

To rework the present design of either unit would impose an undue cost for a modification whose need and benefit have not been fully justified at this time.

The existing orifice locations are in accordance with ISA Standard S67.02, section 6.3.2.

Tne significance of this potential. problem is quite limited due to the following factors:

1)

For those sequences in which water level measurement failures have the greatest contribution to core nelt frequency, RPV depressurication is slow, resulting in significantly less error (about 3: foot per 100'F/ hour cooldown) than for the limiting case (depressurization by ADS) considered.

2).

The error' in water level measurement due to the pressure gradient required to force the fluid thropgh the orifice during flashing will occur only during the actual period of depressurization.

3)

Operator training stresses the potential for inaccuracy in water level indication during rapid depressurization:

The other compensating measures employed at Limerick adequately address reference leg boil-off or flashing conditions.

These measures are described in Response 4, below.

Concern 3:

Variable leg, Reference leg vertical drops not equal (non-parallel lines).

S' 7,.,f b..,_[. C.... ~~ -. ~~ -. N dr.'r~ ~ ~~ 2 '.

= :n---- - M m " '

r

-11

{M

' August 18, 1983 t

t 1

Response 3.(LGS):

The variable and reference legs of the reactor vessel level instru-mentation are as parallel as possible at LGS, that is, the vertical drops within the drywell of both sensing legs are as equal as slope constraints will allow. This design minimizes indicated errors in. level

.due to fluid density changes caused by drywell heatup (such as loss of drywell chillers).

The following chart illustrates the worst case differences in vertical drop:

Reference Leg Variable Leg Range Vertical Drop Vertical Drop Difference Wide 12.422' 12.159' O.263' Narrow

'12.422' 12.155' O.267' Fuel Zone 12.208' 13.917' 1.709' The wide range and narrow range instrument lines are clearly parallel.- 'ahe parallelism of the fuel zone instrument lines may be

. questioned depending on the numerical acceptance criteria used. However, since the difference in elevation drop of the fuel zone instrument lines causes a conservative (i. e., lower than actual) -indication in the control room during conditions of elevated.drywell temperature, it is concluded that the intent of the recommendation which calls for parallel instrument lines is met.

Concern 4:

Reference leg boil-off and flashing.

Response 4 (LGS):

Since the LGS design includes a 12 foot vertical drop of the reactor water level reference leg inside containment, _ high drywell temperature can -lead to boil-off and flashing of. the water in the reference leg during RPV depressurization.

This could cause errors in the' indicated level.

To determine if this error should be further reduced by.repiping'the reference leg, the following were considered:

1)

The scenarios which could lead to a boil-off condition, 2)

The information required by the operator under the.se scenarios, 3)

The guidance provided to the operators in the plant emergency procedures, and 4)

The cost of improvements.

., ? E..

A-

~'

w:

.......... -. - - - - - - - -. ~ - -

r.

.'

  • August 18, 1983 It was determined that-the events leading to substantial boil-off are very improbable and slow moving.

In all cases, the operator will have sufficient time to consult,his operating procedures and take the appropriate actions.

Also, it was determined that even -if considerdale boil-off of the reference leg occurs, indication of level.is still maintained on the wide range instruments, indicated level will change as actual level changes, and indicated level can be used to inform the operator about the adequacy of core cooling. Finally, it was determined that modification of the piping to reduce-the error is prohibitively expensive relative to the potential benefit which could be obtained.

The LGS ' emergency. operating procedures are structured to avoid conditions where boiling and/or flashing of the reference legs would occur and to direct appropriate actions should such conditions develop.

The following discussion of high energy line breaks (previously sent to you as a response to RAI421.3GJ is illustrative of this approach:

High energy line breaks are breaks occurring in a fluid system whose normal plant conditions are either in operation or maintained pressurized under conditions where either or both of the following are mets a.

Maximum cperating temperature exceeds 200*F b.

Maximum operating pressure exceeds 275 psig.

liigh energy line breaks inside containment can be categorized into three sizes:

a) large, b) intermediate, and c) small.

Ea?h break has its own temperature and pressure effects on' the vessel, drywell, and suppression pool.

However, it is the small break that imposes the most severe,long-term temperature conditions on the vessel level instrumenta-

, tion reference legs.

Under a design basis small break accident condition, the maximum temperature in the drywell could approach 255'F.

Given this elevated drywell temperature and the gradual depressurization of the reactor vessel, a potential boilm.ff condition could occur when the reactor vessel pressure falls to the saturation pressure corresponding to the actual drywell temperature (18 psig for a 255'F drywell temperature).

It should be noted that in instruments with cold reference legs, the reference leg temperature can only increase to the drywell ambient temperature.

Thus, under the least favorable conditions, a cold refer-

-ence leg will not boil until the system pressure falls to 55 psia.

For the purpose of this illustration, it is assumed that the reactor and containment are at the maximum normal conditions when a small break occurs that allows blowdown of~ reactor steam to the drywell.

The resulting pressure increase in the drywell leads ~to a high drywell pressure signal that scrams the reactor and initiates the high pressure emergency core. cooling systems and containment isolation.

Drywell temperature would increase and reactor vessel pressure and level will decrease at a slow rate due to the small size of the break.

The automatic depressurization system (ADS) will not initiate until low RPV level and high drywell pressure signals have been received.

l

. I x-

~

.?..

~( -:..;..:..L. -......-. -.

~~

~

. August 18, 1983 The reactor operator is alerted,to the incident by the drywell high pressure and temperature alarms and by the reactor scram.

It is at this point that the operator will start to follow the emergency procedures.

- The operator will be aware of the elevated drywell temperature and

. pressure and is required to monitor and control these parameters as well

.as RPV level and pressure..

During any. accident or transient condition, the operating procedures instruct the operator to control drywell temperature with any available means of drywell cooling (restart tripped coolers, start backup coolers, utilize backup _ cooling water source) and to begin normal RPV depressur-ization (100*F/hr cooldown). _ If available drywell cooling is insufficient to prevent a further increase in temperature, then, before the drywell design temperature _ is reached (340'F), the operator is required to shut down the drywell fans, initiate drywell sprays, rapidly depressurize the vessel, and initiate low pressure makeup systems..The sprays will lower drywell temperature and prevent a reference leg boiling condition from occurring.

Throughout each of these operations, the operator will also monitor RPV pressure and reference leg temperature and compare these parameters against a curve to determino the potential for reference leg boiling.

This comparison is rapidly performed on one of the ERFDS displays.

If the plaht conditions fall '.nto the area.above the. curve where boil-off is possible or if RPV water level cannot bc _ determined, the operator is instructed to depressurize the vessel and initiate low pressure makeup systems. This injection will continue until the' reference leg temperature is reduced and level indication is available'.

' Flooding the vessel ensures that adequate core cooling is maintained throughout the transient.

l If the reactor operator allows conditions to deteriorate,-reference

' leg boiling could occur.

Level indication will be erratic during boiling but will stabilize once boiling stops.

If conditions deteriorate to the point where the total reference leg of the wide range level transmitter boils off inside containment, the operator will still have an active indication of level. -The wide range indicator will indicate approximately +16 inches (on a scale of -150 to +60 ? inches) when the actual' water' level is at the lower instrument tap.

This means tl.at if the reactor operator maintair.s level indication above +16 inches on the wide range indicator, he will have an indication that water is above the lower instrument tap _and hence will know that the fuel is covered. The emergency procedures and operator training will emphasize this fact.-

The operator will be made aware of reference leg flashing long before reaching this point by differing indications on the various. water level instruments and by the ERFDS displays previously described.

e e-


.--.---.....~.+-.,.--.-.vw~~

~h~ >. n#'d,=,.Q =.a.

. u.

~

--..... > -- x ~~1 ^ v ~- % - A - A Y ---- } ~ ^- "

  • ' ~ ~

- - - - - - - = = = ~ - = -

- - ~

" - ' ~

'-~

r

August 18, 1983 s

i t

Although the operator does have. water level indi* cation that is accurate enough ' to+ indicate the adequacy of core - cooling under all

. condition's, further improvement in the accuracy of water level indica-tion may be possible, one metho'd of improving the accuracy would be to reduce the reference leg vertical drop inside the drywell as discussed in SLI-8211.

To implement this modification at ISS.while still main-

~

taining parallel reference and vertical legs would involve. at least 4

- eight new drywell penetrations. - Analysis of the containment will be necessary to.show if this modification is technically feasible from a containment integrity viewpoint.

As noted at the NRC/BWR Owners' Group meeting held on May 19,.1983,. in Bethesda, MD,.such changes would cost-on the order.of $4 million.per unit.

Limerick unique cost estimates have not been developed but are estimated to be similar or slightly

-higher.

In addition to the direct cost, there-will be cost associated with the slippage in the construction schedule caused by such a major modification..

. The cost of making this modification. must be compared. to the potential benefit to be obtained. A methodology to estimate the poten -

tial benefit.(i.e., core melt frequency reduction) associated with water level measurement improvements on a generic -basis was developed and utilized in SLI-8218, " Inadequate Core Cooling in Boiling Water

. Reactors."

SLI-8218 recognizes that the benefit to be derived for a particular plant will be dependent on plant specific features and -

analyses.

In relating this work to LGS, we have found a number of

differences between the generic assessment and the current design of LGS that substantially reduce the contribution to core melt frequency at LGS due to the reactor water level instrument design. The major differences are a)

Improvements to the reactor water level instrumentation at LGS have been made as described above (reference leg parallelism ~

and reference leg thermocouples utilized for ERFDS compensation / display). These features were -not considered in the generic analysis.

b)

There are four electrical divisions of water level instrument-1 ation at LGS for the control of the low pressure emergency core cooling systems.

The generic analysis assumed only two electrical divisions (Table 4-2 of SLI-8218).

The Limerick design is considerably store tolerant of multiple failures.

c)

The LGS drywell cooling system is substantially more reliable than tho generic plant due to redundancy and a backup cooling water source.

The LGS design includes redundant fan / coil units, piping, and chillers and an automatic backup heat sink (reactor enclosure cooling water).

The significance of these differences is discussed in. Sections 4.5.1.1 and 4.5.1.8 and F

' Appendix H of SLI-8218., It is noted that such features would

"... result in a core melt frequency contribution reduction...

of about an order of magnitude."

?

4

~

--a w--

ftf.. (,. :,.,.. ; -

~.... ~.'.....

.., = - = - : f = h : =.h I

~.T ~"

~

~~.

s...

, August 18, 1983 2

d)

The LGS design includes additional features to' mitigate the consequences of an anticipated transient without scram (ATWS) that are not found in the generic plant (Section 4.1.1. of SLI-8218).

e)

The LGS design includes analog transmitters and trip units'in lieu of the mechanical devices assumed to be employed for the generic analysis (Section 4.2 of SLI-8218).

These differences lower the contribution of water level measurement system failures to core melt frequency to a value which is significantly lower.than that shown in the SLI-8218 generic analysis.

Hence, it is concluded that it would not be cost / beneficial to further modify the reactor water level instrumentation at LCS.

We believe that the design of the LGS drywell cooling system and the improve.nents we have made to the LGS water level measuring system are responsive to the findings and conclusions of SLI-8211 and 8218.

The reliability of the measurement system itself has been improved and the operator's ability to recognize potential problems and failures has been substanti.21; f err:.*:d.

Thc improved system will provide the reactor operators with accurate, reliable, water level indication.

It is recognized that an error in indicated level due to reference leg boiling and flashing could result under certain, low probability events.

However, the emergency procedures have been written and equipment has been provided to facilitate the operator's recognition of this event and to assure that appropriate steps to mitigate the effects of such acci-dents are taken.

Concern 5:

Logic configurations may lead to situations and transients that have not been previously considered.

Response 5 (LGS):

The LGS logic design is made up of four (4) divisions.

Of the scenarios investigated in SLI-8211, section 5.2.2, pages 5-44 through 5-48 and 5-51, none presented any challenge to fuel design limits or danger of core uncovery.

This concern is not applicable to LGS and plants of similar logic design.

9 m

- - - - - - - - - - - - - - - - - - -. - - - - - - - - - - - - - - - - - - - - - - - - - = - - - - - - - -

~ ~ ' :-

= -- M -~~ ;- - = '

1-

~

' ~

~ ~ ~

~ ' ~ ~

R;,; _:;;i-[ -- : '

~~~~-

4. '.. August 18, 1983 t

Concern 6:

Mechanical Instrumentation Failures Response 6 (ISS):

The. LGS design calls for electronic transmitters and solid state trip units. Therefore, this concern is not applicable to LGS.

The above discussion shows that the design of the LGS reactor water instrumentation has been improved as recommended in SLI-8211 where such improvement has proven to be cost beneficial This will provide the-

-reactor operators with accurate, reliable, water level indication.

As shown in SLI-8218, this improved instrumentation will enable the opera-tor to verify the adequacy of core cooling.

O 9

6 9

9 4

w n s.

e-s

(

4.4.7 Irstrumentation for Detection of Inadequate Core Cooling (II.F.2)

In response to the staff's request, Philadelphia Electric Company has submitted a report with their transmittal letter of August 23, 1983. This report is

^

their plant specific evaluation report addressing the applicant's position with respect to the BWROG report (SLI-8211, July 1982), " Review of the BWR Reactor Water Level Measurement Systems', and to SLI-8218 (November 1982),

" Inadequate Core Cooling Detection in Boiling Water Reactors."

Page 4-29 of NURG-0991 lists three water level instrumentation concerns, iden-tified in SLI-8211, which must be addressed for Limerick.

In a letter from John S. Kemper (PECo) to A. Schwencer (NRC) dated August 23, 1983, PEco responded to these three concerns. We find the responses to be acceptable. The concerns and evaluation of the responses are given below.

Concern 1 The applicant should consider the BWROG recommendations for upgrading the water level instrumentation to reduce the errors caused by high drywell temperature.

Evaluation For conditions in which there is no reference to leg boil-off or flashing the effect of high drywell temperature is negligible because the vertical drops in the drywell for the variable and reference legs are almost identical.

Substan-tial errors can results from flashing at low pressure because the vertical.

(

drops in the drywell are approximately 12 feet. However, even for worst case conditions, the level instrumentation will sense increases or decreases in level when the indicated level is within the normal operating range. This is 4

adequate to detect decreases in level to assure that the core remains covered with water. Therefore, there is no need to upgrade the instrumentation to reduce errors caused by high drywell temperature.

Concern 2 The applicant should evaluate the water level systems for Limerick to deter-mine if operator action is needed to mitigate the consequences of a break in a reference leg and a single failure in a protection channel associated with an intact reference leg.

If operator action is needed to mitigate the consequences of the cited event, the applicant should consider changing the protection system logic (for reactor trip and/or ESF system (s) actuation on reactor vessel low

(

water level) so that this is accomplished automatically.

Evaluation The Limerick logic design has four divisions and is comparable to plant B in SLI-8211.

In the SLI-8211 review of plant B, there were no cases identified which failed to provide automatic reactor trip and ECCS actuation. Therefore, no changes are required for the Limerick protection system logic.

k Limerick SSER 2 4-2

  • n 2, ' <

Concern 3 The applicant should identify the type of water level indication equipment used for Limerick.

If the mechanical level indication equipment is used, the appli-cant should develop a plan for replacing it with analog level transmitters and trip units to reduce the vulnerability to failures or malfunctions.

Evaluation Limerick uses electronic transmitters and solid state trip units.

Therefore, this concern is not applicable to Limerick.

We have reviewed the concerns identified in SLI-8211 and we find that no changes to the Limerick water level instrumentation ar'e required.

The staff has completed its review of the applicant's responses concerning this issue and has found that the Limerick RWLMS fully conforms with the water level instrumentation modifications recommended in SLI-8211 and no further modifica-tions are required.

The staff has also completed its review of SLI-8218 and has accepted its recommendation that if the reactor water level instrumentation is fully upgraded according to SLI-8211 recommendations that no additional instrumentation is required for the detection of inadequate _ core cooling.

Since the Limerick RWLMS fully conforms with the recommendations of SLI-8211, no addi-tional instrumentation for detection of inadequate core cooling is required.

i

-n

. v -

-. v r-s - -

.nw I

i i l

Limerick SSER 2 4-3

.1