ML20100Q009

From kanterella
Jump to navigation Jump to search
Tabulation of Number of Personnel & Person-Rem by Work & Job Function for 1995
ML20100Q009
Person / Time
Site: Catawba  
Issue date: 12/31/1995
From: Mccollum W
DUKE POWER CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NUDOCS 9603110451
Download: ML20100Q009 (2)


Text

3 e

. II -

l

, Duke 1%rerCompany WwwR. AlcCoutu, JR Catauba Nudear Generation Department Vice hesident 48M ConcordRoad (803)33142M 0ffice l

' York, SC73745 (803)S313426 Fax DUKEPOWER.

' February 29, 1996 U. S. Nuclear Regulatory Commission ggATTN: Document Control Desk

> Washington, DC.20555

Subject:

Catawba Nuclear Station Docket Nos. 50-413 and 50-414 1995 Annual Report In 'accordance with Catawba Nuclear Station Technical Specification (TS) 6.9.1.5(a), find atta'ched the 1995 Catawba Nuclear Station Personnel Monitoring Report.

This attachment provides a tabulation of the number of

station, utility, and other personnel, including contractors receiving exposure greater that 100 mRom/ year, followed by the total dose for each respective worker classification and job function during the 1995 calendar year.

Pursuant TS 6.9.1.5(b) the results of specific activity analysis in which the reactor coolant exceeds the limits as defined in TS 3.4.8 shall be included in the Annual Report.

Catawba did not exceed the specific activity limit during the 1995 calendar year.

Very truly yours,

[.

W. R. McCollum KEN /ANNUALRP.95 Attachment xc: S. D. Ebneter, Regional Administrator R. E. Martin, ONRR R. J. Freudenberger, SRI 9603110451 951231 W

Me c O

\\k PDR ADOCK 05000413 PDR naaww e a

e

.t I

DUKE PtBER CtNANY - CATA9SA MJCLEAR STATIM TABULATION OF MASER W PER$tBGEL ADS PERSW-REM LY MNK AND JtB FUNCTI N FOR 1995 i

1

[

DATE: 02/06/96 e

i MASER OF PERSCM4ELt >100 MREM)

TtfrAL PERSW-REMt >100 MREM) 4

$gNc-t NORK AND Jte F1MCTI M STATIt24 UTILITY CONTRACT NORKERS STATIN UTILITY C MTRACT NORKERS 8 *5 i

EMPLOYEES EMPLOYEES AND OTHERS EMPLOYEES EMPLOYEES AND OTHERS n

g.

E 2."

l

    • IN-SERVICE INSPECTItN
> n m ENGINEERING 1

1 3

0.000 0.001 0.584 D

M M i

HEALTH PHYSICS 10 0

49 0.234 0.000 7.131 87%

$ i. w w MAINTENANCE 115 408 77 8.768 107.569 11.068 Waee I

OPERATING 14 0

1 1.467 0.000 0.005 SUPERVISItN 1

2 0

0.034 0.269 0.000

-=m n t

gu,5 r

    • REACTOR OPERS. 8 SURVEILLANCE ENGINEERING 9

2 6

0.041 0.064, 0.000 k S. $ 00 HEALTH PHYSICS 29 1

89 3.194 0.038 9.861 n

c M UNTENANCE 171 591 110 5.099 11.705 1.195 V'

H o

a SPERATING 93 0

34 26.031 0.000 3.841 SUPERVISItDI 4

3 2

0.274 0.018 0.006 1' E

% 4

- RErUELING ENGDEERING 1

0 0

0.015 0.000 0.000 HEALTH PNYSICS S

0 37 0.522 0.000 2.271 MAINTENANCE 108 326 50 3.497 24.809 3.220 SPERATIPC 62 0

30 0.197 0.000 3.846 M

SUPERVISItDI 1

3 0

0.021 0.026 0.000 g

    • RttrTINE MAINTENANCE ENGINEERING 7

1 1

0.284 0.078 0.001 HEALTH PHYSICS 28 1

80 2.%3 0.033 7.192 MAINTENANCE 170 532 72 38.763 87.255 11.967 OPERATING 53 0

35 0.856 0.000 6.172 SUPERVISItSt 3

2 1

0.404 0.107 0.058 l

weSPECIAL MAINTENANCE ENGINEERING 8

1 2

1.216 0.003 0.315 HEALTH PHYSICS 18 1

73 0.356 0.187 1.566 MAINTENAfCE 124 472 64 5.954 37.747 4.772 OPERATING 75 0

25 0.417 0.000 2.354 r

SUPERVISItDI 2

2 1

0.094 0.003 0.080

  • mHASTE PRtEESSING ENGINEERING 0

0 0

0.000 0.000 0.000 t

HEALTH PHYSICS 14 0

22 1.133 0.000 3.916 MAINTENADCE 12 28 2

0.019 0.031 0.000 UPERATDS 6

0 31 0.303 0.000 0.395 SUPERVISIt24 0

0 1

0.000 0.000 0.002 b

    • TUTAL ENGIPEE!DS 9

2 6

1.556 0.146 0.900 HEALTH PHYSICS 29 1

89 8.382 0.238 31.957 MAINTENANCE 173 596 113 62.100 269.116 32.222 OPERATING 93 0

35 29.271 0.000 16.613 SUPERVISIt24 4

3 2

0.827 0.423 0.146 GRAND TUTAL 308 602 245 102.136 269.923 81.838 NOTE: STATION 'IUTAL DOSE EDR 1995 NAS 462 RDI (TLD)

-