ML20099L772

From kanterella
Jump to navigation Jump to search
Submits Comments on Preliminary Draft of Proposed Low Power License Transmitted by Tm Novak 84115 Ltr
ML20099L772
Person / Time
Site: Catawba Duke Energy icon.png
Issue date: 11/26/1984
From: Tucker H
DUKE POWER CO.
To: Adensam E, Harold Denton
Office of Nuclear Reactor Regulation
References
NUDOCS 8412030090
Download: ML20099L772 (2)


Text

.

DUKE POWER GOMPANY P.O. HOx 33180 CytAHLOTTE, N.C. 28242 HALH. TUCKER TELEPHONE vue ennessen, (704) 373-4531 November 26, 1984

==.- -

Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Comission Washington, D. C.

20555 Attention: Ms. E. G. Adensam, Chief Licensing Branch No. 4 Re: Catawba Nuclear Station Docket Nos. 50-413 and 50-414

Dear Mr. Denton:

Mr. T. M. Novak's letter of November 15, 1984 transmitted a preliminary draft copy of the proposed low power license for Catawba Unit 1.

The following comments were identified and have been discussed with the project manager.

1.

LC(5) - Suggest rewording as follows:

... dated March 9, 1983 and subsequent revisions 1 through 6,...

2.

LC(10) - Reference should be to Section 13.1.2.3.

Also, the requirement for training the advisors and certifying to the hRC the names of the advisors (last 2 sentences at the bottom of page 6) has beendone and was addressed in my letter dated August 31, 1984.

3.

LC(12)(b) - The Emergency Operations Facility is fully functional as evidenced by the drill performed in February 1984.

4.

LC(14) - References should be -(Section 6.2.5 and Appendix C, SER; Section 6.2.5, SSER #2, SSER #3, SSER #4) 5.

LC(16) - Delete reference to SSER #3.

Revise fourth line as follows:

... analyses presented in the FSAR js the most severe case...

6.

LC(17)(a)(V) - The referenced analysis will be performed for the limiting break not a spectrum of breaks, in accordance with previous discussions with the Staff.

7.

LC(18) - The references should be -(Section 5.'4.4, SER, SSER #2, Section 15.4.4,SSER#3) 8.

LC(20) - This item should be deleted based on my letter of November 21, 1984.

9.

LC(23) - The references should be -(Section 13.3, SER, SSER #1, SSER #2, SSER#3) s I

~

Mr.- Harold R. Denton, Director.

November.26, 1984 Page Two Very truly yours, h

.e

/

Hal' B. Tucker ROS: sib

-Mr. James P._0'Reilly', Regional Administrator cc:

U. S. Nuclear Regulatory Commission Region II 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia. 30323 NRC Resident Inspector Catawba Nuclear Station Mr. Robert Guild, Esq.

P. O. Box 12097 Charleston, South Carolina 29412 Palmetto Alliance 21351 Devine Street Columbia, South Carolina 29205 1

Mr.-Jesse L. Riley Carolina Environmental Study Group 854 Henley Place Charlotte, North Carolina 28207 2

1 i

L L.

l L

. _