l OPERATING DATA REPORT-DOCKET NO 50-255 DATE-11-08-84 COMPLETED BY AFDienes

. TELEPHONE (616)764-8913 OPERATING STATUS-Notes 1.

Unit Name: Palisades 2.

-Reporting Period:

841001-841031-3.

Licensed Thermal Power (MWt):

2530

'4 Nameplate Rating (Gross MWe):

811.7 5.'

Design Electrical Rating (Net MWe):

805 6.

Maximum Dependable capacity (Gross MWe): *675 7.

Maximum. Dependable Capacity (Net'MWe):

  • 635 8.

If Changes Occur in Capacity Ratings (Items Number 3 through.7) since last report, give reasons:

a 9.

Power Level to Which Restricted, if any (Net MWe):

10. Reasons for Restrictions, if any:

This Month Yr-to-Date Cumulative

11. Hours In Reporting Period 745 7,320 112,815 12.

Number of flours Reactor Was Critical 0

567.9 59.827.1

13. Reactor Reserve Shutdown Hours 14 Houra Generator On-Line 0

368.4 56,646.4

15. Unit Reserve Shutdown Hours
16. Gross Thermal Energy Generated (MWH) 0 399,312 115,759,536
17. Cross Electrical Energy Generated (MWH) 0 118,080 35,868,520
18. Net Electrical Energy Generated (MWH) 0 101,747 33,729,761
19. Unit Service Factor 0

5.0 50.2

20. Unit Availability Factor 0

5.0 50.2 21.

Unit capacity Factor (Uning MDC Net) 0 2.2 47.1

22. Unit Capacity Factor (Using DER Net) 0 1.7 37.1

~

23. Unit Forced Outage Rate 100 83.6 33.5 24.

Shutdowns Scheduled Over Next Six Months (Type, Date and Duration of Each):

25.

If Shut Down at End of Report Period, Estimated Date of Start Up:

November 13, 1984

26. - Units in Test Status (Prior to Commercial Operation):

Forecast Achieved INITIAL CRITICALITY INITIAL ELECTRICITY COMMERCIAL OPERATION

  • Based on cor. denser backpressure OC1083-0100B-TC03 8411260122 841031 h

DR ADOCK 05000255 t/

PER

.,6 e

f:

AVERACE DAILY UNIT POWER LEVEL DOCKET NO 50-255 UNIT -

Palisades DATE 11-08-84 COMPLETED BY AFDienes

. TELEPHONE (616)764-8913 s

MONTH.

October 1984 DAY AVERAGEDAILYPOWERLEVE$

DAY AVERAGE DAILY POWER LEVEL (MWe-Net).

' (Mk*e-Net) i 1

0 17 0

2 v

18 0

3 0

19 0

4 0

20 0

5 0

21 0

6 0

22 0

7 0

23 0

8 0

24 0

. '9 0

25 0

10 0

26 0

11 0

27 0

12 0

28 0

'13 0

29 0

14 0

30 0

15 0

31.

0 16 0

INSTRUCTIONS:

On this format, list the average daily unit power invel in MWe-Net for each day in the reporting month. Compute to the nearest whole megawatt.

OC1083-0100C-TC03

~ ~..

c.-...

-,,e

o e

DOCKET NO.

50-255 UNIT SHLTOWNS AND POLER REDUCTIONS UNIT NAME Palisades DATE 11-08-84 CCEPLETED BY CHCoralski REPORT !DNTH OCIDBER 1984 TELFFHONE (616)-764-8913 1

2 No.

Date Type Duration Reason Method of Licensee Systy Compogent Cause & Corrective (Ecurs)

Shuting Event Code Code Action to 3

Down Reactor Report #

Prevent Recurrence 6

840916 F

745 A

1 84-21 AB P

Seals failed on primary coolant pump, P-50C.

1.

2.

3.

4.

5.

F: Forced Reason:

Method:

Exhibit G - Instructions Exhibit I - Same Source S: Scheduled A-Equipment Failure (Explain) 1-Manual for Preparation of Data B-Maintenance or Test 2-Manual Scram Entry Sheets for Licensee C-Refueling 3-Automatic Scram Event Report (LER) File D-Regulatory Restriction 4-Other (Explain)

(NURFG-0161)

E-Operatcr Training & License Examination F-Administrative C-Operational Error (Explain)

(9/77)

H-Other (Explain)

OC1083-0100D-TC03

~

&; ;a _ "
2

-y 9.

St!MMARY OF OPERATING EXPERIENCE FOR OCTOBER 1984

.The Plant remained shutdown the entire month of October due to repairs on primary coolant. pump P-50C..

l OC1083-0100E-TC03

4-Consume!3 power Campany Palesades Nuclear Ptent 2778o Blue Star Memonal Nghway. Covert. MI 49043 November 8, 1984 US Nuclear Regulatory Conunission Mail and Records Section Washington, DC 20555 LICENSE REPORT OF MONTHLY OPERATING DATA DPR-20, DOCKET NO 50-255 Enclosed is a copy of the Monthly Operating Data and a Summary of, Operating Experience for the Palisades Nuclear Plant for the month of October 1984.

g Dewey VanDenBerg Reactor Engineer CC: GilGoralski, Palisades JGKeppler, USNRC JRSchepers, P24-314 DJVandeWalle, P24-614B DWRogers, Palisades Resident Inspector, Palisades DLila cke tt, Pll-228B LABrown, P21-317 GWDruckmann, Div of Radiological llealth Services, Lansing, Michigan SMicrzwa, Michigan Dept of Labor RCallen, Michigan Public Service Commission KMFarr, Palisades Records Center, INPO, Atlanta, GA RWTaylor, CE, Palisades JBToskey, P25-101 EWRaciborski, P26-204 DRGanser, P26-205 Document Control, 950*22*35*10/L 011G84*016 l

l OC1083-0100A-TC03 I

l