di DUKE PowEn GOMI%NY 1*.O. DOX 03180 CIIAHLOTTE. N.C. 28242 IIAL H. TUCKEH

)

TELErnoxe Jh q O 'm (yo4) 373 453:

== rer.m==,

SepteN er 2b,' g 4 mm.--m Mr. James P. O'Reilly, Regional Administrator U. S. Nuclear Regulatory Commission Region 11 101 Marietta Street, NW, Suite 2900 atlanta, Georgia 30323 Re: Ril:WPA "

50-413/83-51-02

Dear Mr. O'Reilly:

Please find attached a description of the Quitkpipe computer program used in the structural analysis for small bore piping systems. This description will be included, as shown, in Revision 12 to the FSAR.

This should satisfactorily resolve Inspector concerns in regard to Inspector Follow-Up ltem 413/83-51-02, Piping Analysis Modeling.

Very truly yours,

/h Hal B. Tucker LTP/mjf Attachment cc: NRC Resident Inspector Mr. Jesse L. Riley Catawba Nuclear Station Carolina Environmental Study Group 854 Henley Place

!!r. Robert Guild, Esq.

Charlotte, North Carolina 28207 Attorney-at-Law P. O. Box 12097 Harold R. Denton Charleston, South Carolina 29412 Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Palmetto Alliance Washington, D. C. 20555 2135 Devine Street Columbia, South Carolina 29205 8411200567 840922 OFFICIAL COPY PDR ADOCK 05000413

~ [ cQ W f

l lb l

s

y;

,r e

.~%

y.

Tab'le39.1-6'(Page(28)~

Computer Programs Used in Analysis Application:

Quickpipe A.

Author:

Impe11 Corporation (formally EDS Nuclear, Inc.)

Southeast Region Office 333 Technology Park / Atlanta Norcross, Georgia 30092 Source:

Impe11 Corporation Version:

3A dated June 25, 1984 Facility:

Impe11 Corporation B.

D,pcription:

Quickpipe is a computer program for the structural asalysis and code compliance evaluation of small bore piping systems.

It is used for qualification of ASME Section III, Class 2 and 3 piping as well as some seismic qualification of ANSI B31.1 piping.

Quickpipe can perform the analysis by means of either a stress-controlled or frequency-controlled basis for gravity, thermal and/or seisr.ic loading cases.

The program also features suitable algorithms to optimize excessive support locations spotted in the analysis if desired.

Quickpipe is an extension of Impe11 Corporation's Superpipe program developed primarily as an alternative to the hand calculation methods required by the Alternate Analysis procedures described in Section 3.7.3.8.3.

Extent and Limitation of its application:

Quickpipe is limited to analysis of 4" and under nominal piping systems.

C.

Verification:

The program has been bench-marked against the Impell program Superpipe.

Rev. 12 New Page