. _

~ _ _ _ _ _ _ _

r g.

k.

l 3

(

carolins Power & Light core.pany fJUL 271992 SERIAL: NLS 92194 United States Nuclear Regulatory Commission ATTENTION: Document Control Desk Washington, DC 20555 i

1 BRUNSWlCK STEAM ELECTRIC PLANT, UNIT NO. 2 DOCKET NO. 50 324/ LICENSE NO. DPR 62 NUREG 0619 FEEDWATER NOZZLE AND SPARGER EXAMINATION RESULTS SUBMITTAL OF REPLACEMENT GENERAL ELECTRIC REPORT l

Gentlemen:

By letter dated June 8,1992 (Serlah NLS 22134), Carolina Power & Light Company submitted, pursuant to Nuclear Regulatory Commission NVREG 0619, subsection 4.4.3.1(2), the results of notdestructive examination of the feedwater rozzles and spargers for the Brunswick Steam Electric Plant, Unit 2. The Company has deterriined that the General Electric Company report provided as enclosure 2 o. the June 8,1992 submittal was inadvenently missing section 7.

Therefore, for your convenience, a complete cop, of the General Electric report is provided herein.

Please refer any questions regarding this subml;tal to Mr. W. R. Murray at (919) 546-4661.

Yours very truly, l

D. C, McCarthy Manager Nuclear Licensing Section WRM/wrm (b2r00619.sup)

Encicsure i

cc:

Mr. S. D. Ebneter l

Mr. R. H, Lo Mr. R. L. Prevatte 30004o d

Gy \\

m max - m u m w m axa 4tt r yeneune sueet e o en ini. nagn N cvm J

a 9208030162 920727 3:;T a rm rsa ma s tm a s51&s y m; I

POR ADOCK 05000324 4

P PDR u

. _... _., _ _ _.. _ ~

-