ML20098E112

From kanterella
Jump to navigation Jump to search
Forwards Rev 1 to TDR 580, Isolation Condenser Sys Piping Cracked Welds - Repair & Failure Analysis, Technical Data Rept,Per 840829 Request
ML20098E112
Person / Time
Site: Oyster Creek
Issue date: 09/21/1984
From: Fiedler P
GENERAL PUBLIC UTILITIES CORP.
To:
Office of Nuclear Reactor Regulation
Shared Package
ML20098E114 List:
References
NUDOCS 8409280186
Download: ML20098E112 (1)


Text

-

,'gg' 3

GPU Nuclear Corporation N

Uhg[

Post Office Box 388 Route 9 South Forked River,New Jersey 08731-0388 609 971-4000 Writers Direct Dial Nurnber:

September 21, 1984 Director Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, DC 20555

Dear Sir:

Subject:

Oyster Creek Nuclear Generating Station Docket No. 50-219 Isolation Condenser System Piping Cracked Welds -

Repair and Failure Analysis Pursuant to our meeting with members of your staff on August 29, 1984, revision no.1 to Technici Data Report (TDR) No. 580 is attached for your review. Changes to TOR 580 are described in detail on page la of its text.

The revision includes the additional information you had requested at our meeting.

Please contact Mr. Drew G. Holland of my staff at (609)971-4643 in the event that any comments or questions arise.

ery tr 1 yours, eter B, fledled, M.

,d

[Mic.e President ahff Director

j0ysterCreek PBF/daia Attachment cc
Dr. Thomas E. M'Irley, Administrator Recin I U.S. Nuclear Regulatory Commission 631 Park Avenue King of Prussia, PA 19406 NRC Resident Inspector Oyster Creek Nuclear Generating Station Forked River, NJ 08731 dd 8409280186 840921 gDCADOCK05000 GPU Nuclear Corporation is a subsidiary of the General Public Utilities Corporation