ML20098D507
| ML20098D507 | |
| Person / Time | |
|---|---|
| Site: | Oyster Creek |
| Issue date: | 07/31/1984 |
| From: | Belmore C, Hillman R BATTELLE NEW ENGLAND MARINE RESEARCH LABORATORY |
| To: | |
| Shared Package | |
| ML20098D492 | List: |
| References | |
| 15245, NUDOCS 8409270630 | |
| Download: ML20098D507 (26) | |
Text
_ _ _ _ _ _ _ _
PROGRESS REPORT FOR THE THIRTY-SEVENTH QUARTER On i
STUDY OF WOODBORER POPULATIONS IN RELATION TO THE OYSTER CREEK NUCLEAR GENERATING STATION To GPU NUCLEAR CORPORATION August 31,1984 by R.E. Hillman and CJ. Belmore REPORT NO.15245 May 1,1984 to July 31,1984 BATTELLE New England Marine Research Laboratory Duxbury, Massachusetts 02332 Battelle is not eagaged in research for advertising, sales promotion, or publicity purposes, and this report may not be reproduced in full or in part for such Purposes.
8409270630 840913 PDR ADOCK 05000219 R
TABLE OF CONTENTS Page EX EC UTIVE SUM M ARY.........................................................................
i IN TR OD UCTION..............................................................................................
1 PROCEDURES AND 'NTERIM D ATA..................................................................
2 E xposure Pane ls.........................................................................................
2 W ate r Quali t y.........................................................................................
2 Teredinid Gonadal Development Studies....................................................
2 LIST OF TABLES Table 1.
Geographic Locations of Exposure Panel Arrays 'In Barnegat Bay, New 3ersey..............................................................................
4 Table 2.
Incidence of Teredinidae in Panels Removed May 14-15, 1984.............
8 Table 3.
Incidence of Teredinidae in Panels Removed June 1 1-12, 198 4.............
9 Table 4.
Incidence of Teredinidae in Panels Removed July 9-10, 1984...............
10 Table 5.
Incidence of Limnoria in Panels Removed May, June, and July,1984....
11 Table 6.
Water Quality at Exposure Panel Stations, May 14-15, 198 4................
12 Table 7.
Water Quality at Exposure Panel Stations, June 1 1-12, 19 84................ 13 Table 8.
Water Quality at Exposure Panel Stations, July 9-10, 198 4..................
14 Table 9.
Condition of Gonads of Teredinid Borers Removed from Exposure Panels in Barnegat Bay from April through June,1984........................
15 LIST OF FIGURES Figure 1.
Outline of Bamegat Bay Showing Geographic Locations of E xpos ur e Pane ls...............................................................................
3
i EXECUTIVE
SUMMARY
l This progress report presents data from field and laboratory work during the period May 1 to July 31, 1984. Also included are the results of observations on gonad development in samples collected in April, May, and June,1984.
All field work during this quarter was carried out by GPU Nuclear personnel.
Temperature, salinity, dissolved oxygen and pH were measured and recorded at each of the 20 stations during the three periods of exposure panel exchange.
Teredinidae were found in the six-month exposure panel removed in May,1984 from the Coast Guard Station. Prior to 1983, no shipworms had ever been found in exposure panels removed in May or June from sites in Barnegat Bay.
For the most part, gonad development was in the early active stage through April and May, and into the late active phase in June. A notable exception was at Station 17, where many of the Teredo navalis specimens recovered in April were ripe to partially spawned. This was also true of June's sample. Otherwise, development patterns were normal for this time of year.
l 1
PROGRESS REPORT FOR THE THIRTY-SEVENTH QUARTER on STUDY OF WOODBORER POPULATIONS IN RELATION TO THE OYSTER CREEK NUCLEAR GENERATING STATION to GPU NUCLEAR CORPORATION August 31,1984 by Robert E. Hillman and CJ. Belmore I
REPORT NO.15245 May 1,1984 to July 31,1984 from BATTELLE New England Marine Research 1.aboratory Duxbury, Massachusetts 02332 INTRODUCTION Britelle's New England Marine Research Laboratory is conducting an investigation en determine whether the Oyster Creek Nuclear Generating Station is affec:ing the i uldent marine borer population in Oyster Creek to the extent that that population is co stributing significantly to marine borer-caused damage in Barnegat Bay.
A description of the program and procedures used may be found in the eighth annual report titled, " Study of Woodborer Populations in Relation to the Oyster Creek Generatind Station", dated May 15,1984.
- - - - - ~ - - - ' - - - ' - - - - - - - - ' -
2 This report presents data for the thirty-seventh quarterly period from May 1 to July 31,1984.
PROCEDURES AND INTERIM DATA l
E==re panels The long-term and short-term exposure panels were retrieved and replaced with new untreated pre-soaked (for two weeks) panels at the 20 exposure sites in Barnegat Bay and adjacent waters (Figure 1) during the periods of May 14-15, June 18-12, and July 9-10, 1984. Long-term and short-term panels at all stations were retrieved and replaced by personnel from GPU's Oyster Creek Nuclear Generating Station.
Table 1 describes the geographical locations of the exposure sites. Data from the laboratory examination of the panels are presented in Tables 2 through 5.
Dater Quality Salinity, water temperature, dissolved oxygen and pH were taken at each site by the GPU Nuclear field team. Results for May, June, and July,1984 are presented in Tables 6 through 8.
Teredinid Gonadal Development Studies Table 9 shows the gonad condition of teredinid borers collected in April, May, and June,1984. Included are results from panels exposed for periods ranging from 6 to 12 months.
NLET SmELLE 4%At poeN INfmACOASTAL #
WATERWAY CANAL MANTOLQe.NG Is K
ECASEK 4
i to r
SLOOP CREEN ATLANTIC OCEAN HOLLY PARK GO S70075 CREEK 108 to DOE S$
STER OYSTER CREEM 8
~
Nu EAR GENERAflNG I sARNEGAf WAAETQWN SARNEGAT SEACH CONNLIN g PANEL AmeAv iSLANO t
3 humedammmame=d MILES
,g 7 INLET NEWJERSEY t
l FIGURE 1.
OUTLINE OF BARNEGAT BAY SHOWING GEOGRAPHIC LOCATIONS OF EXPO 5URE PANEL 5
TABLE 1.
GEOGRAPHICAL LOCATIONS OF BATTELLE NEW ENGLAND MARINE RESEARCH LABORATORY'S EXPOSURE PANEL ARRAYS IN BARNEGAT BAY, NEW JERSEY Structure to be used for Nearest Previous Approximate Latitude Site No.
Site Suspension of Rack Data Stations and Longitude 1.
Barnegat Coast Guard Finger Pier WC1 Lat. 390 45.8'N Station, Barnegat Inlet Bulkhead WFCL 1948-1967 Long. 740 06.5'W 2.
Ashton Marina Bulkhead WC 13,14 Lat. 390 40'N 1450 Bay Ave.
Long. 74013'W Manahawkin 3.
Iggie's Marina Bulkhead WC 16,17,18,19 Lat. 390 45'N East Bay Ave.
Long. 740 12.5'W Barnegat (Conklin Island) 4.
Liberty Harbor Marina Bulkhead WC 21 Lat. 390 47'N Washington Ave.
R. Turner Long.740 ll'W Waretown Rutgers U.
l 4-A *.
Holiday Harbor Marina Bulkhead WC 21 Lat. 390 48'N l
Lighthouse Drive R. Turner Long. 740 1l'N Waretown Rutgers U.
5.
Mouth of Oyster Creek, Dock WC 29,30 Lat. 390 48.5'N Lot 4, Compass Road Rutgers U.
Long. 740 10.3'W Offshore End 6.
Oyster Creek 1 Dock Lat. 390 48.5'N Lagoon, Inshore End Long. 740 10.35'W 37 Capstan Road
i TABLE 1. (Continued) ructure to be used for Nearest Previous Approximate Latitude Site No.
Site Suspemion of Rack Data Stations and Longitude 7.
Private Dock End of Dock WC 27,28 Lat. 390 48.5'N Dock Ave.
R. Turner Long. 740 ll.I'W Oyster Creek Rutgers U.
Sands Pt. Harbor Waretown 3*.
Oyster Creek Bulkhead 1500 ft.
WC 26 Lat. 390 48.7'N Discharge Canal east of the R.R.
Long. 740 12'W bridge 9*.
Forked River Metal pier WC 31 Lat. 390 49.2'N South Branch Long. 740 12.2'W Intake Canal 10.
Teds Marina Pier WC 33,34 Lat. 390 50.I'N Bay Ave.
Long. 740 ll.6'W Forked River 10A *.
Private Dock Under Dock Lat. 390 49'N 1217 Aquarius Ct.
Long. 740 10'W Forked River 10B*.
Private Dock Under Dock Lat. 390 49.4'N 1307 Beach Blvd.
Long. 740 10.I'W Forked River 11.
Forked River Bulkhead WC35 Lat. 390 49.7'N l
(near mouth)
Rutgers U.
Long. 74010'W 1413 River View Drive l
l l
TABLE 1. (Continued)
Structure to be used for Nearest Previous Approximate Latitude Site No.
Site Suspension of Rack Data Stations and Longitude 12.
Stouts Creek Bulkhead WC 38,40,41 Lat. 390 50.5'N 1273 Capstan Drive R. Turner Long. 740 08.8'W Wurtz Rutgers U.
13.
Rocknak's Yacht Basin End of Pier WC 46 Lat. 390 52'N Barramore Ave.
Long. 740 09'W Lanoka Harbor Cedar Creek 14.
Dicks Landing Pier WC 49 Lat. 390 54'W Island Drive R. Turner Long. 740 08.I'W Bayville (Holly Park)
Nelson 15.
Winter Yacht Basin Inc.
Pier WC57 Lat. 400 02.5'N Rt.328 Long. 740 04.9'W Mantoloking Bridge 16*.
Berkely Yacht Basin Pier WC 60,61 Lat. 390 55.9'N i
- 3. Street Long. 740 04.9'W Seaside 16A*.
Municipal Dock Pier WC 60,61 Lat. 390 56.6'N Seaside Heights Long. 740 04.9'W 16B*.
Bayside Boats Pier WC 60,61 Lat. 390 56.6'N State Highway 35 and Long. 740 04.9'W Bay Boulevard Seaside Heights, N3
TABLE 1. (Continued)
Structure to be used for Nearest Previous Approximate Latitude Site No.
Site Suspension of Rack Data Stations and Longitude 17.
island Beach Pier WC 68 Lat. 390 47.I'N State Park Long. 740 05.9'W (Sedge Island)
All exposure panel racks suspended in a minimum water depth at mean low water of at least three feet. Racks hung with nylon line from existing structures so the bottom panels are close to, but not touching the bottom. Racks at Forked River railroad bridge and Oyster Creek railroad bridge suspendu! with wire rope.
WC = Woodward-Clyde WFCL = William F. Clapp Laboratories Site 4-A instal!ed April,1977.
Sites 10A,10B installed April,1978.
Site 16 discontinued November,1981.
l Site 16A installed December,1981 - discontinued June,1982.
l Site 16B installed June,1982.
l l
l l
I a
8 l
TABLE 2. INCIDENCE OF TEREDINIDAE IN PANELS REMOVED MAY 14-15, 1984 No. of Percent Size Range Station Panel Specimens Filled in mm.
Species Identification 1
P 170
<1
<1 170 Teredinidae*
C 0
Stations 2 No Teredinidae present.
P = Long-term panel submerged November 7-8, 1983.
C = Short-term panel submerged April 16-17, 1984.
= Not speciated due to size.
l
9 l
l TABLE 3. INCIDENCE OF TEREDINIDAE IN PANELS REMOVED JUNE 11-12, 1984 No.of Percent Size Range Station Panet Specimens Filled in mm.
Species Identification Stations 1 No Teredinidae present.
i
__ _ - _ - - - - " - - - - - ~ - - "
10 i
i i
TABLE 4. INCIDENCE OF TEREDINIDAE IN PANELS REMOVED JULY 9-10,198 No.of Percent Size Range Station Panel Specimens Filled in mm.
Species Identification 1
P O
C 2
<1 1-2 2 Teredinidae*
7 P
1
<1 3
1 Bankia spp.
C 0
8 P
O C
1
<1
<1 1 Teredinidae*
11 P
9
<1 1-3 2 Bankla spp.,7 Teredinidae*
C 7
<1 1-3 1 Bankla spp.,6 Teredinidae*
12 P
1
<1
<1 1 Teredinidae*
C 0
Stations 2-6,9-10B,13 No Teredinidae present.
P = Long-term panel submerged January 9-10, 1984.
C = Short-term panel submerged June 11-12, 1984.
- = Not speclated due to size.
11 l
TABLE 5. INCIDENCE OF LIMNORIA IN PANELS REMOVED MAY, JUNE, AND JULY,1984.
May June
- July *
- No. of No.of No. of No. of No. of No. of Station Panel Tunnels Specimens Tunnels Specimens Tunnels Specimens 1
P 0
0 14 21 C
0 0
0 2
P 2
0 93 153 310 480 C
7 2
34 57 36 49 3
P O
4 6
16 11 C
0 2
3 0
4 P
0 0
3 2
C 0
1 0
0 4A P
2 2
230 315 690 1000 C
0 14 4
56 80 Stations 5 No Limnoria present.
P = Long-term panel, submerged 6 months.
C = Short-term panel, submerged 1 month.
- = Gravid females present.
- = Gravid females and juveniles present.
1 1
l
12 TABLE 6. WATER QUALITY AT EXPOSURE PANEL STATICHS MAY,1984 Depth in Salinity Temperature O2 Station Date Time Feet o/oo (OC)
(mg/1) pH I
5/14/84 0939 5.5 28.8 11.8 8.0 7.6 2
5/14/84 1025 5.5 20.0 17.0 7.6 8.1 3
5/14/84 1110 2.0 18.0 17.1 7.8 8.1 4
5/14/84 1138 3.0 20.0 17.0 7.4 8.0 4A 5/14/84 1200 2.0 19.9 17.2 6.6 7.5 5
5/14/84 1230 1.5 7.2 16.2 9.4 7.4 6
5/14/84 1252 2.0 9.3 16.9 9.4 7.8 7
5/14/84 1313 3.5 15.1 17.1 8.9 7.9 8
5/14/84 1337 2.0 15.1 16.7 9.0 7.9 9
5/14/84 1444 5.5 16.7 16.2 7.6 7.0 10 5/15/84 1343 4.0 16.1 15.3 7.2 7.4 10A 5/14/84 1518 1.5 16.9 17.0 9.8 8.0 103 5/14/84 1530 3.0 17.1 17.1 9.6 8.1 11 3/14/84 1548 1.5 12.8 16.2 9.4 7.8 12 5/15/84 1308 2.5 14.9 16.0 9.3 8.2 13 5/15/84 1240 3.0 13.9 16.0 8.5 7.7 14 5/15/84 1208 2.0 12.2 15.8 8.8 7.7 15 5/15/84 0900 3.0 13.9 14.0 8.7 7.5 16B 5/15/84 0930 4.0 9.5 15.0 8.1 7.3 17 5/15/84 1012 1.0 24.0 13.8 7.9 7.9
13 TABLE 7. WATER QUALITY AT EXPOSURE FANEL STATIONS I
JUNE,1984 1
I Depth in Salinity Temperature 02 Station Date Time Feet o/oo (OC)
(mg/1) PHI 1
6/11/84 0910 5.0 28.8 19.6 6.2 6.2
- 2 6/11/84 0950 5.5 21.6 27.9 5.3 6.0
- 3 6/11/84 1020 1.5 20.9 27.5 5.8 6.1
- 4 6/11/84 1045 3.5 20.7 28.0 4.0
- 6. l
- 4A 6/11/84 1100 2.0 20.7 28.0 5.4 6.4
- 5 6/11/84 1120 1.2 13.0 27.3 6.8 6.3
- 6 6/11/84 1133 2.0 13.8 28.0 6.6 6.3
- 7 6/11/84 1148 3.0 16.7 26.5 5.6 6.0
- 8 6/11/84 1210 2.0 16.8 27.0 5.6
- 6. l
- 9 6/11/84 1340 5.0 16.3 25.2 4.1 6.6 10 6/11/84 1511 4.0 13.7 27.2 4.7 6.7 10A 6/11/84 1408 1.2 17.0 29.8 6.8 7.6 10B 6/11/84 1424 3.0 16.6 29.9 7.0 7.6 11 6/11/84 1440 2.0 11.9 30.3 7.0 7.3 12 6/11/84 1533 3.0 16.6 29.5 6.6 7.5 13 6/11/84 1600 2.5 12.7 28.9 5.4 6.9 14 6/12/84 1240 3.5 11.8 27.3 6.4 7.2 15 6/12/84 0925 3.0 14.8 26.9 6.4 7.3 16B 6/12/84 1000 4.0 11.0 27.0 6.3 7.2 17 6/12/84 1122 1.0 22.8 26.5 5.4 7.0 i
I roblems were experienced with the operation of pH meters on both days. Values identified P
with an asterisk are unusually low and probably represent erroneous readings.
14 TABLE 8. WATER QUALITY AT EXPOSURE PANEL STATIONS JULY,1984 Depth in Salinity Temperature O
Station Date Time Feet o/co (OC)
(mg 1) pH 1
7/9/84 0906 5.0 27.0 19.0 6.9 7.8 2
7/9/84 0942 5.0 26.8 22.5 6.2 7.6 3
7/9/84 1015 1.5 19.0 22.9 6.1 7.5 4
7/9/84 1037 3.5 20.0 23.5 6.0 7.2 4A 7/9/84 1059 2.0 20.3 24.5 5.6 7.3 5
7/9/84 1117 1.0 8.4 22.0 7.2 6.9 6
7/9/84 1133 2.0 7.6 21.5 7.4 6.7 7
7/9/84 1149 3.5 14.0 24.2 6.0 7.0 8
7/9/84 1210 2.0 13.8 24.8 5.6 7.0 9
7/9/84 1232 5.5 16.0 24.2 5.4 7.1 10 7/9/84 1434 4.0 14.0 24.5 5.2 7.1 10A 7/9/84 1339 1.0 16.5 25.5 8.2 8.0 10B 7/9/84 1358 3.0 16.8 25.2 7.6 7.8 11 7/9/84 1410 1.0 13.8 24.2 8.3 7.8 12 7/9/84 1548 3.0 15.0 25.3 9.6 8.3 13 7/9/84 1458 2.5 11.8 24.2 7.2 7.1 14 7/9/84 1521 3.0 13.6 24.5 8.4 7.9 15 7/10/84 0858 4.0 10.7 23.3 7.3 7.0 16B 7/10/84 0930 4.0 11.2 23.5 7.0 7.2 17 7/10/84 1013 1.0 23.0 23.1 3.4 7.3
TABLE 9. CONDITION OF GONADS OF TEREDINID BORERS REMOVED FROM EXPOSURE PANELS IN BARNEGAT BAY FROM APRIL THROUGH JUNE,1984 EA=Early active; LA= Late active; R= Ripe; PS= Partially spawned; S= Spent; M= Male; F= Female; H= Hermaphrodite 1
Month No. Months Gonad Specimen No.
Station Removed EW Species Sex Condition Comments l
l 1373 a 7
Apr 84 12 Bankia gouldi M
S Special panel b
Bankia gouldi M
S c
Bankia gouldi No discernable gonad 1374 a 12 Apr 84 12 Bankia gouldi Special panel; no b
Bankia gouldi M
S U
c Bankia gouldi No discernable gonad 1375 a 17 Apr 84 12 Teredo navalis F
PS Special panel; cytolysis of gonad b
Teredo navalis M
EA Necrotic c
Teredo navalis No discernable gonad; necrotic d
Teredo navalis M
PS e
Teredo navalis M
LA f
Teredo navalis M
PS Necrotic g
Teredo navalis H
S Necrotic h
Teredo navalis F
PS
' i Teredo navalis F
R Cytolysis j
Teredo navalis F
PS Cytolysis k
Teredo navalis H
S 1
TABLE 9.
(Continued)
Month No. Months Gonad Specimen No.
Station Removed Exposed Species Sex Condition Comments 1376 a 11 Apr 84 12 Bankia gouldi M
EA Special panel b
Bankia gouldi M
EA c
Bankia gouldi M
EA d
Bankia gouldi No discernable gonad e
Bankia gouldi M
EA l
f Bankia gouldi M
EA g
Bankia gouldi M
EA h
Bankia gouldi M
EA i
Bankia gouldi F
EA l
j Bankia gouldi M
EA k
Bankia gouldi No discernable gonad 1
Bankia gouldi M
EA Cytolysis m
Bankia gouldi M
EA Cytolysis 1377 a 15 May 84 12 Bankia gouldi Special panel; no discernable gonad b
Bankia gouldi No discernable gonad c
Bankia gouldi M
LA 1378 a 15 May 84 12 Teredo navalis M
LA Special panel b
Teredo navalis F
R 1379 16B May 34 12 Bankia gouldi M
EA Special panel 1380 14 May 84 12 Teredo navalis F
R Special panel
TABLE 9. (Continued)
Month No. Months Gonad Specimen No.
Station Removed EW Species Sex Condition Comments 1381 a 8
May 84 12 Bankia gouldi M
LA Special panel b
Bankia gouldi M
LA c
Bankia gouldi No discernable gonad d
Bankia gouldi F
S 1382 a 14 May 84 12 Bankia gouldi M
LA Special panel b
Bankia gouldi M
EA c
Bankia gouldi F
EA l
d Bankia Louldi No discernable gonad l
e Bankia goulot M
S f
Bankia gouldi M
EA g
l g
Bankia gouldi M
EA w
l h
Bankia gouldi M
LA i
Bankia gouldi F
EA j
Bankia Louldi M
EA k
Bankia goulat M
EA I
Bankia Louldi M
LA m
Bankia gouldt M
LA n
Bankia gouldi M
LA o
Bankia gouldi M
LA 1383 a 7
May 84 12 Bankia gouldi Special panel; no l
discernable gonad I
b Bankia gouldi No discernable gonad c
Bankia Louldi No discernable gonad d
Bankia gouldi M
LA
l l
l TABLE 9. (Continued)
Month No. Months Gonad Specimen No.
Station Removed Exposed Species Sex Condition Comments 1384 a 10B May 84 12 Bankia gouldi Special panel; no discernable gonad b
Bankia gouldi M
LA 1385 a 11 May 84 12 Bankia gouldi H
LA Special panel l
b Bankia pouldi M
EA l
1386 a 12 May 84 12 Bankia gouldi M
LA Special panel b
Bankia gouldi No discernable gonad c
Bankia gouldi M
EA l
d Bankia gouldi M
LA 5
1387 a 11 May 84 12 Bankia gouldi H
EA Special panel b
Bankia gouldi M
LA c
Bankia gouldi M
LA d
Bankia gouldi M
PS e
Bankia gouldi M
LA f
Bankia gouldi M
LA g
Bankia gouldi M
EA h
Bankia gouldi M
LA i
Bankia gouldi M
EA j
Bankia gouldi M
EA k
Bankia gouldi M
LA 1
Bankia gouldi M
LA 1388 a 7
May 84 12 Bankia gouldi M
LA Special panel b
Bankia gouldi M
EA c
Bankia gouldi M
LA d
Bankia gouldi No discernable gonad i
f,
TABLE 9. (Continued)
Month No. Months Gonad Spec.imen No.
Station Removed Exposed Species Sex Condition Comments l
l 1389 a 17 May 84 12 Teredo navalis F
LA Special panel b
Teredo navalis M
EA l
1390 a 17 May 84 12 Bankia gocif Special panel; no discernable gonad b
Bankia gotfdi M
EA 1391 12 May 84 12 Bankia gouldi M
EA Special panel 1392 a 14 May 84 11 Bankia gouldi F
EA Special panel r
b Bankia gouldi M
LA c
Bankia Louldi H
LA d
Bankia gouldi M
LA e
Bankia gouldi M
LA f
Bankia gouldi M
EA g
Bankia gouldi M
LA h
Bankia gouldi M
EA i
Bankia gouldi M
LA-j Bankia gouldi M
LA 1393 a 11 May 84 11 Bankia gouldi M
LA Special panel b
Bankia Louldi M
EA i
c Bankia gouldi M
LA I
d Bankia gouidi No discernable gonad I
e Bankia goi:M M
EA f
Bankia gouldi H
EA g
Bankia gouldi M
LA h
Bankia gouldi M
EA i
j
_Bankia gouldi H
LA bankia gouldi M
l TABLE 9. (Continued)
Month No. Months Gonad Specimen No.
Station Removed Exposed Species Sex Condition Comments 1394 a 17 May 84 12 Teredo navalis M
PS Special panel b
Teredo navalis F
R c
Teredo navalis F
R d
Teredo navalis M
LA e
Teredo navalis M
PS f
Teredo navalis H
PS g
Teredo navalis M
PS h
Teredo navalis F
R i
Teredo navalis M
PS j
Teredo navalis H
PS O
1395 17 May 84 12 Bankia gouldi M
EA Special panel l
1396 a 8
Jun 84 12 Bankia gouldi M
R Special panel b
Bankia gouldi H
R l
c Bankia gouldi M
R l
1397 a 11 Jun 84 12 Bankia gouldi M
LA Special panel b
Bankia gouldi F
PS 1398 a 7
Jun 84 12 Bankia gouldi M
LA Special panel i
b Bankia gouldi No discernable gonad c
Bankla gouldt M
LA d
Bankia gouldi F
PS
TABLE 9. (Continued)
Month No. Months Gonad Specimen No.
Station Removed Exposed Species Sex Condition Comments 1399 11 Jun 84 12 Teredo navalis F
LA Special panel 1400 a 15 Jun 84 12 Bankia gouldi M
PS Special panel b
Bankia gouldi F
PS 1401 13 Jun 84 12 Bankia gouldi M
PS Special panel 1402 12 Jun 84 12 Bankia gouldi F
PS Special panel 1403 a 12 Jun 84 12 Bankia gouldi Special panel; no discernable gonad b
Bankia gouldi No discernable gonad U
c Bankia gouldi No discernable gonad 1
1404 2
Jun 84 12 Teredo navalis F
PS Special panel 1405 17 Jun 84 12 Teredo navalis F
R Special panel; necrotic 1406 a 17 Jun 84 12 Teredo navalis M
PS Special panel b
Teredo navalis F
PS c
Teredo navalis H
PS d
Teredo navalis M
PS Necrotic e
Teredo navalis M
PS f
Teredo navalis H
PS g
Teredo navalis M
PS h
Teredo navalis F
PS
TABLE 9. (Continued)
Month No. Months Gonad Specimen No..
Station Removed Exposed Species Sex Condition Comments 1406 (Continued) i Teredo navalis M
PS j
Teredo navalis F
R k
Teredo navalis F
PS 1
Teredo navalis F
LA m
Teredo navalis F
R n
Teredo navalis M
PS o
Teredo navalis M
PS p
Teredo navalis M
PS q
Teredo navalis F
PS r
Teredo navalis M
PS U
s Teredo navalis H
PS t
Teredo navalis F
R u
Teredo navalis M
PS v
Teredo navalis M
PS 1407 16B June 84 12 Bankia gouldi M
LA Special panel 1408 a 7
Jun 84 12 Bankia gouldi M
R Special panel b
Bankia gouldi M
PS c
Bankia Louldi No discernable gonad d
Bankia goulot M
PS
a%f Battelle New England i
Marine Research Laboratory l
397 Washington Street Duxbury, Massachusetts 02332 l
Telephone (617) 934-5682 l
_ _ _ _ _ _ _