UNITED STATES -

n 3

1 NUCLEAR RF,GULATORY-COMMISSION o,

[

. WASHINoToN, o.C. 20665 DMKE POWER COMPANY-DOCKET NO. 50-369 McGUIRE NUCLEAR STATION. UNIT 1 AMEN 0 MENT TO FACILITY OPERATING LICENSE Amendment No. 133 License No..NPF-9 1.

The Nuclear Regulatory Commission (the Commission) has found that:

A.

The application for amendment to the McGuire Nuclear Station, Unit-1 (the facility), Facility Operating License No. NPF-9 filed by the Duke Power Company (licensee) dated February 5,1992, complies with the standards and. requirements of the Atomic Energy Act;of 1954, as-amended (the-Act), and the Commission's rules and regulations:as: set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application,1the provisions of the Act, and.the rules and regulations of= the-Commission; C.

There is reasonable assurance (i) that the activities authorized by this amendment can'be conducted without endangering the-health-and safety of the public, and (11) that such activities will be conducted-in compliance with the Commission's regulations set forth-in 10 CFR Chapter I; D.

The issuance of this amendment will not be inimical: to the common defense-and security or to the; health and safety _of-the public; and.

E.

The issuance of'this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

9206170317 920611 PDR ADOCK 05000369 P-PDRo

7

. 2.

Accordingly, the license is hereby amended by page changes to the Technical Specifications as indicated in the attachment to this license amendment, and Paragraph 2.C.(2) of facility Operating License No. NPF-9 is he eby amended to read as rollows:

Technical Specification:

The Technical Specifications contained in Appendix A, as revised i

through Amendment No. 133, are hereby incorporated into this license.

The licensee shall operate the facility in accordance with the Technical Specifications and the Environmental Protection Plan.

3.

This license amendment it effective as of its date of issuance.

FOR THE NUCLEAR REGULATORY COMMISSION

$4c b David B. Matthews, Director Project Directorate 11-3 Division of Reactor Projects-1/l!

Office of Nuclear Reactor Regulation

Attachment:

Technical Specification Changes Date of Issuance:

June 11, 1992

e

/p* ** %g*

i UNITED STATES 3

D i

NUCLEAR REGULATORY COMMISSION of WASHINoTON. D C. ME

.\\

/

DUKE POWER COMPAt{1 (K!GET NO. 52-J29 McGUIRE NUCLEAR STATIE UNIT 2 ILMEkDMENT 10 FAClllTY OPERATING LICEliS1 Amendment No. 115 License No. NPF-17 i

1.

The Nuclear Regulatory Commission (the Commission) has found that:

A.

The application for amendment to the McGuire Nuclear Station, Unit 1 (the racility), facility Operating License No. NPF-17 filed by the Duke Power Company (licensee) dated February 5, 1092, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's rules and regulations as set 4

forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations set forth o 10 CFR Chapter I; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

m_____

. 2.

Accordingly, the license is hereby amended by page changes to_the Technical Specifications as indicated in the attachment to this license amendment, and Paragraph 2.C.(2) lows:of facility Operating License No. NPF-17 is hereby amended to read as fol Technical Soecifications The Technical Specifications contained in Appendix A, as revised through Amendment No. 115, are hereby incorporated into this license.

The licensee shall operate the facility in accordance with the Technical Specifications and the Environmental Protection Plan.

3.

This license amendment is effective as of its date of issuance.

FOR llE NUCLEAR REGULATORY COMMISSION ditd Dav d B. Matthews, Director Project Directorate 11-3 Division of Reactor Projects-1/ll Office of Nuclear Reactor Regulation

Attachment:

Technical Specification Changes Date of Issuance:

June 11,1992

ATTACHMENT TO LICENSE AMENDMENT NO. 133 FACILITY OPERATING LICENSE NO. NPF-9 QQCKET NO. 50-369 AND TO LICENSE @ DMENT NO. 115 FAClllTY OPERATING LICENSE NO. NPF-17 DOCKET NO. 50-370 Replace the following page of the Appendix "A" Technical Specifications with the enclosed page.

The revised page is identified by Amendment number and contains vertical lines indicating the areas of change.

Remove Pang Insert Pace 3/4 7-17 3/4 7-17

4 6

PLANT SYSTEMS I>

SURVEILLANCE REQUIREMENTS (Continued)

(1) Verifying that the cleanup system satisfies the in place penetration and bypass leakage testing acceptance criteria of less than 1% and uses the test procedure guidance of Regulatory Positions C.S.a. C.S.c and C.S.d of Regulatory Guide 1.52, hvision 2. March 1978, and the system flow rate is 45,700 cfm i 10% (both fans operating - (Unit 1) or 40,500 cfm i 10% (both fans operating - Unit 2);

(2) Verifying within 31 days after removal that a laboratory analysis of a representative carbon sample obtained in accordance with Regulatory Position C.6.b of Regulatory Guide 1.52, Revision 2, March 1978, meets an acceptance criteria for methyl iodide penetration of less than 10% at 30'C test temperature, and l

b.

After every 1440 hours0.0167 days <br />0.4 hours <br />0.00238 weeks <br />5.4792e-4 months <br /> of carbon adsorber operation, by verifying,ive car-within-31 days after removal, that a laboratory analysis of a representat bon simple obtained in-accordance with Regulatory Position C.6.b of Regula-tory Guide 1.52. Revision 2, March 1978, meets an acceptance criteria for methyl iodide penettdion of less than 10% at 30'C test temperature, and l

At least once per 18 months, by verifying that the pressure drop across c.

the combined HEPA filters and carbon adsorber banks of less than 6 inches Water Gauge while operating the system at a flow rate of 45,700 cfm i 10%

(both fans operating - Unit 1) or 40,500 cfm i 10% (both fans operating -

Unit 2), and d.

After each cut plete or partial replacement of a HEPA filter bank, by verifying that the HEPA filter bank setisfies the in place penetration and bypass leakage testing criteria of less than 1% in accordance with ANSI N510-1980 for a DOP test aerosol while operating the system at a flow rate of 45,700 cfm i 10% (both fans operating Unit 1); or 40,500 cfm i 10% (both fans operating - Unit 2); and After each complete or partial replacemont of a carbon adsorber bank, by e.

verifying that the carbon adsorber satisfies the in place penetration and bypass leakage testing acceptance criteria of less than 1% in accordance with ANSI N510-1980 for a halogenated hydrocarbon refrigerant test gas while operating the system at a flow rate of 45,700 cfm i 10% (both fans operating - Unit 1). or-40,500 cfm i 10% (both fans operating - Unit 2).

4.7.7.2 Each Unit's Auxiliary Building Filtered Ventilation Exhaust System flowpath shall be demonstrated OPERABLE:

a.

At least once per 31 days, by initiating, from the control room, flow through the HEPA filters and carbon adsorbers and varifying that the system operates for at_least 15 minutes.

b.

At least once per 18 months, or (1) after any structural maintenance on the HEPA filter or carbon adsorber housings, or (2) following McGUIRE - UNITS 1 and 2 3/4 7-17 Amendment No.133 (Unit 1)

Amendment No.115 (Unit 21