e_

ll; I

m l

Duheher Company WwAu R. ALCcwx JR

.e Catawi>a Nuclear Generation ikvartwent Viceknident

_l 43M ConcordRoad (8M)33143X) Office '

Wrk,SC2976 (80)8313c6Far DUKEPOWER February'11, 1996 U. S. Nuclear Regulatory Commission ATTN:

Document Control Desk Washington, DC 20555

Subject:

Catawba Nuclear Station, Unit 2.

Docket No. 50-414 Special Report Vibration and Loose Parts Monitoring System On January 2, 1996, Unit 2 Loose Parts Monitoring (LPM) System

' Channel 17 (S/G 2C Manway) was declared inoperable.

No signal was present as evidenced by the background RMS signal being essentially zero.

This indicates a probable dead preamp.

This channel was logged as Item #C2-96-0016 in the Technical Specification Action Item Log (TSAIL).

Work request 96000226 was generated to investigate and repair this channel during an outage of sufficient duration.

Problem Investigation Process (PIP)2-C96-0004 is the tracking document for this failure. Two other' channels are operable and providing coverage against loose parts.

The above information is submitted pursuant Catawba Nuclear Station Selected Licensee Commitment Section 16.7-4 and Technical Specification 6.9.2.,

since this channel could not be restored to operable within 30 days.

Sincerely, W. R. McCollum KEN /SR021196. LPM

xc: S. - D. Ebneter, Regional Administrator 1.60 0 %. E. Martin, ONRR

[

R '

R. a. groudenberger, SRI 9602160004 960211

.\\ h PDR ADOCK 05000414 S

.pon w =xycws.,

l

{...

~

U. S. Naclear Regulatory Commission

-February 11, 1996 Page 2 bxc: ELL

- EC050 NSRB Staff

- EC05N K. E. Nicholson - PIP 2-C96-0004 JR Fox

- CN03SE CN-801.01

' - CN02DC NCMPA-A SREC PMPA NCEMC 1

l l