ML20097D335

From kanterella
Jump to navigation Jump to search
Proposed Tech Specs 3/4.6.1.1 & 3/4.6.1.3 to Incorporate Option B 10CFR50,App J
ML20097D335
Person / Time
Site: Wolf Creek Wolf Creek Nuclear Operating Corporation icon.png
Issue date: 02/08/1996
From:
WOLF CREEK NUCLEAR OPERATING CORP.
To:
Shared Package
ML20097D331 List:
References
NUDOCS 9602120308
Download: ML20097D335 (2)


Text

<

Attschment to WO 96-0020 Piga' 1 df 2 l

l ATTACHMENT I REVISED TECHNICAL SPECIFICATION CHANGE 9602120308 960208 PDR ADOCK 05000482 P

PDR

Attachment to WO 96-0020 Pcfgd 2 6f 2 DEFINITIONS CONTAINMENT INTEGRITY 1.7 CONTAINMENT INTEGRITY shall exist when:

a. All penetrations required to be closed during accident conditions are either:
1) Capable of being closed by an OPERABLE containment automatic isolation valve system, or
2) Closed by manual valves, blind flanges, or deactivated automatic valves secured in their closed positions, except as provided in Tabic 3.6-1 of Specification 3.6.3.
b. All equipment hatches are closed and sealed,
c. Each air lock is in compliance with the requirements of Specification 3.6.1.3,
d. The sealing mechanism associated with each penetration (e.g., welds, bellows, or O-rings) is OPERABLE, and b*d 4.6.1_.k
e. The containment leaka rates determined by Specification are withir@imits.

the 92:r: cf Spe P-"en 1'4.S.1%)

CONTROL 1 FD LEAKAGE 1.8 CONTROLLED LEAKAGE shall be that seal water flow from the reactor coolant pump seals.

CORE ALTERATION 1.9 CORE ALTERATION shall be the movement or manipulation of any component within the reactor vessel with the vessel head removed and fuel in the vessel.

Suspension of CORE ALTERATION shall not preclude completion of movement of a component to a safe conservative position.

CORE OPERATING LIMITS REPORT 1.10 The CORE OPERATING LIMITS REPORT (COLR)is the unit-specific document that provides core operating limits for the current operating reload cycle.

These cycle-specific core ope ating limits shall be determined for each reload cycle in accordance with Specification 6.9.1.9. Plant operation within these operating limits is addressed in individual Specifications.

WOLF CREEK - UNIT 1 1-2 Amendment No. 64,89