ML20097D300

From kanterella
Jump to navigation Jump to search
Provides Supplemental Response to Violation 90-48-01 in Insp Rept 50-325/90-48 on 911021-25.Util Continues to Maintain That ASME Code Does Not Require Recording of Acceptable Relevant Indications
ML20097D300
Person / Time
Site: Brunswick 
Issue date: 06/05/1992
From: Spencer J
CAROLINA POWER & LIGHT CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NUDOCS 9206100054
Download: ML20097D300 (2)


Text

$E,1 EAER%D2lmM:MlMWn'New Carolina Power & Ught Company BM a r a nw m ds m e m

  • m m a:s Brunt"ick Nuclear Project
0. Box 10429 Southport, N.C.

28461-0429 JUN bd FILE:

B09-135100 U.S. Nuclear Regulatory Commission ATTN:

Document Control Desk Washington, D. C. 20555 BRUNSWICK STEAM EIICTRIC PIANT UNITS 1 DOCKET NO. 50 325 LICENSE NO. DPR-71 SUPPLEMENTAL RESPONSE TO VIOLATION 90-48-01 AND IER 91-32 Centlemen:

During the week of October 21-25, 1991, inspection 91-32 of the Brunswick Steam Electric plant was conducted. In the ensuing inspection report, a supplemental response was requested regarding a response to a Notice of Violation 50-325/90-48-01, " Recording of Radiographic Indications".

SL 4 Violation 50-325/90-48-01, " Recording of Radiographic Indications" states that paragraph T-292 of the ASME Code was violated by not recording relevant but acceptable indications.

CP&L continues to maintain that the ASME Code does not require the recording of acceptable relevart non-linear indications on a radiographic report.

ASME Code interpretatian V77-06 (Attachment 1) indicates that the recorda of radiographs, showing only acceptable flaws, indications, discontinuities, etc.,

need only list the radiograph as being acceptable and that the ASME Code does not require that the individual flaws be documented.

The above cited ASME Code interpretation was modified by an ASME Section III Interpretation III-1-78-07 (May 13, 1982) which indicated that for Section III work, accessible " linear" indications that require evaluation to determine acceptability shall be recorded and disposed on the report form.

The indications cited by the NRC inspectors are three rounded indications eaca less than 3/32" maximum dimensions. - These indications, although greater than 1/32" (the minimum size of a relevant rounded indication for this pipe wall thickness) are not of a reportable size, and therefore, are not required to be recorded un the Radiographlc inspection Report.

9206100054 920605 PDR ADOCK 05000325 G

PDR C60/

W

s Very truly yours, q

a v

J J.

Spencer, General Manager Brunswick Nuclear. Project RK/

Enclosure cc:

Mr. S. D. Ebneter Mr. R. H. Lo BSEP NRC Resident Office

-<9.-