e.

U-0731 0210.6-L L30-84 (09-10 )-L llLINO/S POWER COMPANY IP CLINTON POWER STATION. P.o. BOX 678. CLINTON. ILUNOIS 61727 Septenber 10, 1984 Docket No. 50-461 Director of Nuclear Reactor Regulation Attention:

Mr. A.'Schwencer, Chief Licensing Branch No. 2 Division of Licensing U. S. Nuclear Regulatory Commission Washington, D. C.

20555

Subject:

Clinton Power Station Unit 1 Incor; oration of Licensing Review Group (LRG)-II Position Papers into the Operating License Application SER Confirmatory Issue #69

Dear Mr. Schwencer:

In a letter from D. L. Holtzscher, Chairman of LRG-II, to J. J.

Stefano, Nuclear Regulatory Commission (NRC), dated June 29, 1984, three generic position papers were transmitted to the NRC. The purpose of this letter is to incorporate these same position papers into the operating license application for Clinton Power Station. The position papers are:

7-CPB, Revision 1, Rod Withdrawal Transient Analysis 4-CSB, Containment Purge Operational Data Gathering and Evaluation Program 5-CSB, Containment Access Management Program In addition, enclosed is an attachment entitled " Interim Guidelines for Containment Purge Operation Clinton Power Station - Unit 1".

The information in this attachment and the LRG-II generic position papers 4-CSB and 5-CSB constitute Illinois Power's response to Confirmatory Issue #69.

P]aase contact us if you have any' questions on the information provided.

Sincerely yours, Daniel I. Herborn Director - Nuclear Licensing 8409170353 840910 and Configuration PDR ADOCK 05000461 Nuclear Station Engineering E

PDR TLR/DIH/Im Attachment B. L. Siegel, NRC Clinton Licensing Project Manager NRC Resident Office V

\\

Regional Administrator, Region III, USNRC g

Illinois Department of Nuclear Safety w