A 4

s s

e a

A L

NUCLEAR OPERATING CORPORATION fc: rest T. Rhodes Vice President Ingirienng & Techrucas Seroces May 20, 1992 ET 92-0107 U. S. Nuclear Regulatory Commission ATTN 2 Document Control Desk Mail Station P1-137 Washington, D.

C.

20555

Reference:

1) Letter ET 91-0073, dated June 11, 1991, from i

F. T. Rhodes, WCNOC to the NRC 4

2) Letter ET 91-0168, dated August 30, 1991 from F. T. Rhodes, WCNOC, to N2C
3) Amendment No. 50, dated November A,

1991, fccm W. D. Reckley, NRC to B. D. Withers, WCNOC

Subject:

Docket No. 50-482: Additional Information Concerning the Resistance Temperature Detector Bypass System Removal Gentlemen:

The purpose of this letter is to provide information for the Wolf Creek Generating Station (WCGS) concerning the replacement of the Resistance Temperature Detector (RTD) bypass system.

Amendment No.

50 (Reference 3),

[

to the VCGS Facility Operating License No.

NPF-42 approsed technical specification changes to allow the replacement of the existing RTD bypass system with an RTD thermowell system.

Reference 1 submitted the original amendment application.

Reference 2 provided revised technical specification pages and committed to provide a comparison of post-modification data ageinst the most recent pre-modification data to assess the effects on T at WCGS. The Attachment provides Reactor Coolant System temperature Oeadings acquired at the beginning of Cycle 5 and Cycle 6.

9205270103 c[OS2O

?o Box dit Burkngton. Ks e<>a39 : Phone (316) 364 8831

[

DR ADOCK 0500 2

/f[

y gg %, tun <tv Employer M F HC VET

ET 92-0107 Page 2 If you have any questions concerning this matter, please contact me or Mr.

5.

G. Wideman of my staff.

Very truly yours, Forrest T. Rhodes Vice President Ergineering & Technical Services FTR/aem At taclunent cc:

A. T. Howell (NRC), w/a R. D. Martin (NRC), v/a G. A.

Pick (NRC), w/a W.

D. Reckley (NRC). w/a I.

g

..m

..-.m.__-_.

-*^

-Attachment to ET 92-0107 COMPARISON OF RCS TEMPERATURE INDICATIONS BEFORE AND AFTER RTD BYPASS SYSTEM REMOVAL Pre-Modification.(Collected 5/24/90, 99.92 power, degrees F)

- Loop 1 Loop 2 Loop 3 Loop 4 T-Hot _.

615.4 616,1 616.7 615.5 T-Cold 559.7 359.4 559.9 558.5 Average T-Hot

- 615.9 average T-Cold 559.5 Post-Modification (Collected 4/3/92, 99.9% power, degrees F)

Loop 1 Loop 2 Loop 3 Loop 4

-T-Hot 617,1 615.8-616.9 615.3

.T-Cold 559.2 559.5 560.1 558.7 Average T-Hot 616.3 Average T-Cold 559.4 l

l i.

.