PRAIRIE ISLAND UNITS 1 AND 2 ROD SWAP METHODOLOGY NSPNAD-8408 July 1984 l

r l

i 1

Prepared By Y & :_ W b M ate / S V

Reviewed By [3 8 M

w 4 Date F"//G[?Y Approved By Date f/

iv

-v j

8409100183 840823 PDR ADOCK 05000 l

P Page 1 of 23 i

i

~-

LEGAL NOTICE This report was prepared by or on behalf of Northern States Power Company (NSP).

Neither NSP, nor any person acting on behalf of NSP:

a.

Makes any warranty or representation, express or implied, with respect to the accuracy, completeness, usefulness, or use of any information, apparatus, method or process disclosed or contained.

in this report, or that the use of any

'such information, apparatus, method, or process may not infringe privately owned rights; or b.

Assumes any liabilities with respect to the use of, or for damages resulting

.from the use of, any information, apparatus, method, or process disclosed in the report.

Page 2 of 23

ABSTRACT This document is a Topical Report describing the Nort.1ern States Power Company (NSP) methodology for determining control rod reactivity worth with the Rod Swap technique.

The methodology employed is explained and data obtained from Prairie Island Unit 1 Cycle 9 and Unit 2 Cycle 8 are presented to validate the methodology.

This methodology is applicable for both Prairie Island Unit I and Unit 2.

l r

I i

l l.

l l^

l Page 3 of 23 1

TABLE OF CONTENTS Pan a

1.0 INTRODUCTION

6 2.0 CALCULATIONAL THEORY AND METHODS 8

2.1 -Rod Swap Methodology 8

l 2.2 Calculational-Theory 9

3.0 MEASUREMENT DATA ANALYSIS 12 3.1 dank Worth Determination 12 3.2 ' Acceptance Criteria 16 4.0 TEST RESULTS AND COMPARISONS 18

5.0 CONCLUSION

S 21

6.0 REFERENCES

22 l

l i

(

l Page 4 of 23

LIST OF TABLES Page 3.1 Measured Critical Position Adjustments 15 4.1 Prairie Island 2 Cycle 8 Rod Swap vs. Dilution /Boration 19 4.2 Prairie Island 1 Cycle 9 Rod Swap vs. Oilution/Boration 20 l

Pagd 5 of 23 i

,,... ~

1.0. INTRODUCTION This report addresses.the replacement of the boration/ dilution method for control rod reactivity worth determination with the Rod Swap. method.

This determination is used to validate the calculational results and verify the shutdown margin.

The boration/ dilution technique involves changing the boron concentration in

'the coolant while simultaneously changing the control rod position to keep the core nominally critical.

In dilution, as primary grade water is put into the reactor coolant system to dilute the boron concentration, a control rod bank is inserted into the core. The rate of this reactivity exchange is limited by the operational considerations during testing.

Typical measurement times of between eight and ten hours have been the norm.

The rod swap technique is an alternative method used to verify the control rod worth predictions of the calculational models.

In rod swap, the control rod bank with the highest worth is measured by the dilution technique, and then each of the other rod banks is swapped in turn as the highest worth bank is withdrawn to keep the system critical.

The advantages of this technique are threefold:

1)

The reactivity worth measurements are performed on the two shutdown banks as well as the control banks.

In the dilution method only the control banks are measured.

2)

The time associated with the reactivity worth measurements is reduced by six to eight hours.

i 3)

The rod swap technique significantly reduces the water inventory required for dilution.

Page 6 of 23

The rod swap technique was employed side-by-side with the dilution reactivity measurements during the startup physics testing for Prairie Island Unit 2, Cycle 8 and Prairie Island Unit 1, Cycle 9.

This report outlines the proposed rod swap methodology and presents a comparison with the side-by-side dilution measurements taken. The applicability of this report encompasses the use of rod swap for both units of the Prairie Island power station.

l 1

I

)

Page 7 of 23

2.0' CALCULATIONAL THEORY AND METHODS 2.1 Rod Swap Methodology.

The rod swap tests are designed to measure the reactivity worth of each control rod bank and, by comparison to calculated values, valiadte the models used for the predictions. This will verify the shutdown margin as calculated by these models.

The rod swap procedure involves using the dilution technique to measure the reactivity worth of the most reactive control rod bank, referred to as the reference bank. At the completion of the dilution, a boron endpoint and isothermal temperature coefficient are measured. The isothermal temperature coefficient is measured for later use in correcting reactivity worth for temperature drift during the test. At this point test data is collected which describes the reactor condition.

This statepoint is referred to as the reference bank statepoint. The test data collected is:

1) reference and test bank positions 2) reactivity computer reading in pcm 3) moderator temperature Boron concentration measurements are taken continuously during the test for later use in correcting reactivity worth for boron drift which may have occurred during the test.

The swap technique proceeds as follows: With the reactor maintained at or near critical, the reference bank is withdrawn while one of the other rod banks, referred to as the test bank, is inserted (':wapped in').

The test bank is fully inserted and the reference bank is adjusted until the core is critical.

This core condition is referred to as the test bank statepoint.

page 8 of 23

The h'eight of the reference bank is the measured critical position (h") of the reference. bank for this test bank. With the reference bank at h", the reactivity computer reading in pca, and the moderator temperature are recorded.

The reference bank is then alternately withdrawn and inserted a few steps to determine the differential reactivity worth per unit of inst 4 tion about h".

The differential reactivity worth. is measured for later use in correcting for changes in test' conditions.

This rod swap process is repeated for each of the other test banks.. When all control. banks'have been measured, all rod banks will be returned to the position they were.in after the reference bank dilution.

The reference bank test data:

1) reference and test bank positions, 2) reactivity computer reading in pcm, and 3) moderator temperature, is recorded again to ensure that the system has remained stable.

The major parameter of interest is in the inferred worth of the test bank in the presence of the reference bank at rod position h".

The reference bank positions, reactivity computer readings, moderator temperatures, and boron concentrations recorded during the test are used to adjust the inferred worth for changes in test conditions.

These adjustments are discussed in detail in section 3.1.

2.2 Calculational Theory

,v l

The design data required for rod swap.is generated by the NSP DP5 nodal L

model and methodology as shown in Reference.l. The DP5 model predicts

.all information needed for the rod swap test including:

1)

The integral worth of each rod bank inserted alone along with the identity of the most reactive, or reference, bank.

2)

The critical boron concentration with the reference bank fully I

inserted in the core.

Page 9 of 23

3)

'The integral and differential worth of the reference bank inserted alone.

4)

The integral and differential worth of the reference bank with each test bank fully inserted.

The determination of the predicted critical position and test bank worth in P

the presence of the reference bank at h is performed as follows.

a)

Determine the most reactive rod bank using the individual integral worths of each bank calculated as in item one above.

b)

Determine the predicted critical position using the reactivity balance equation below:

RP=TP + ARPT where l

RP = the total predicted integral worth of the reference bank inserted alone.

i TP = the total predicted integral worth of the test bank' inserted alone.

ARPT = the integral worth of the reference bank inserted from the fully withdrawn position to hp in the presence of the fully inserted test bank.

l The RP and TP are found from the individual integral worths from item one above.

The ARP is solved for in the above reactivity T

[

balance:

ARPT=TP-RP Page 10 of 23 i:

hP is determined by finding the rod position corresponding to ARPT on the reference bank integral worth curve in the presence l

of the test bank from item four above.

c)

Determine the predicted test bank worth in the presence of the reference bank at the predicted critical position using the reactivity balance equation below:

RP=TPAR + AN where RP = the total predicted integral worth of the reference bank inserted alone TPAR = the total integral worth of the test bank in the presence of the reference bank at hP ARP = the integral worth of the reference bank inserted.

alone from the fully withdrawn position to hP P

P Both R and AR are found from the predicted integral worth curve for the reference bank inserted alone from item three above.

P T

is solved for in the reactivity balance above.

g TPAR = RP - ARp TPAR is used for comparison to the inferred measured worth.

TPAR does not represent the dilution worth of the test bank, however it is merely a parameter used to evaluate the uncertainty of the core physics model for calculation of rod worths and validate the assumtions used in the calculation of shutdown margin.

Page 11 of 23

3.0 MEASUREMENT DATA ANALYSIS 3.1 Bank Worth Determination As previously outlined, stat'epoint data collected during rod swap is used M

to adju'st the measured critical position (h ) to take into account any differences between the reference bank statepoint and the test bank statepoints.

In addition, another adjustment is made to compensate for any differences between the reference-bank-in all-other-banks-out condition and the actual control rod bank. configuration when the reference bank.

statepoint data is collected.

The corrections made are as follows:

1)

Adjustments for moderator temperature variations between critical statepoints.

2).

Adjustments for variations in the baron concentration between critical statapoints.

1 l

3)

Adjustments for deviations from criticality between critical

(

statepoints.

l.

L-4)

Adjustments for deviations in control rod position from the reference-bank-in all-other-banks-out condition at the reference bank statepoint.

L L

l Page 12 of 23

These corrections make certain that statepoint data for each rod configuration is based upon the same core reactivity and boron concentration.

For the first adjustment, a reference-bank-in ITC is measured and the temperature, recorded for this statapoint as well as for each test bank statepoint.

The second correction requires that

. periodic boron measurements be taken throughout the test so that any

-variations in baron concentration can be taken into account.

The accuracy

- of these measurements does not allow comparison of specific baron measurements.

The third correction requires that the reactivity computer reading in pcm be recorded at the reference bank statepoint and each of the test bank statepoints. The fourth correction requires that the difference in reactivity between the actual control rod bank positions at the reference bank statapoint and the reference-bank-in all-other-rods-out

condition be measured,' and the actual control rod bank positions be recorded.

- The following equation is used to make these adjustments.

h* = hN - [ ( [AT * *T] + [ACB

  • CB3+APc + Ap ) * (1/Ap/Ah) ]

g where:

. h3 = The measured critical position of the reference bank with the test bank fully inserted, after all adjustments have been made.

hN =~The measured critical position of the reference bank with the test l

bank fully inserted.

j AT = The increase in the measured moderator temperature between the reference bank statepoint and the test bank statepoint.

[

T = The isothermal temperature coefficient measured at the reference bank statepoint.

l

~

Page 13 of 23 L_

ACB = The increase in the measured RCS boron concentration between the reference bank statepoint and the test bank statepoint.

C8 = The boron worth coefficient calculated using DPS and supplied before the test using methodology shown in Reference 1.

ApC = The decrease in reactivity between the reference bank statepoint and the test bank statepoint as measured by the reactivity computer.'

Apg = The' measured reactivity of the~ actual control rod bank positions at the reference bank statepoint minus the reactivity at the reference-bank-in all-other-rods-out condition Ap/Ah = The measured differential reactivity worth of the reference bank in th's region about h per unit of insertion.

These data adjustments were demonstrated with the exception of the moderator temperature correction for which data was not available. This data for both Prairie Island Unit 1 Cycle 9 and Unit 2 Cycle 8 are presented on Taole 3.1.

The measured reactivity worth of the test banks are found in the same manner as the predicted worths using an analogous, reactivity balance equation.

N = T*AR + AN R

where:

RM = The total measured integral worth of the reference banA inserted alone.

T*AR = The total integral worth of the test bank with the reference bank at h*.

AR" = The measured integrai worth of the reference bank inserted alone from the fully withdrawn position to h".

Page 14 of 23

TABLE 3.1

' MEASURED CRITICAL POSITION ADJUSTMENTS Rod Total M

Test h

Boron Reactivity Position Adjustments

  • h*

Cycle Bank (steps)

(pca)

(pcm)

(pcm)

(steps)

(steps)

Prairie' B

144 0

0 0

0 144 Island 2 Cycle 8 C

199 0

6 0

1 200 D

158 0

-2 0

0 158 SA 152 0

2 0

0 152 SB 152 0

-7 0

-1 151 l^

Prairie C

152 0

0 24-3 155-Island 1 l

Cycle 9 8

107 0

-1 24 2

109 l-0 138 0

4 24 4

142 No temperature adjustments were made due to lack of data.

L Page 15 of 23

N Both R and AR* are found-from the measured integral worth curve for the reforence bank inserted alone. Therefore:

M T'AR = R - AR*

t T*AR is found from this reactivity balance and is compared to T Both of P

R.

these quantities are based upon critical control rod bank statepoint comparisons beginning at the same configuration, reference-bank-in all-other-rods-out.

3.2 Acceptance Criteria 1

For the dilution /boration technique, the acceptance critaria is based upon a comparison of the measured and predicted control rod bank worths as expressed by the following equation.

Ap(%) = Ameas ~ ' design

  • 100%

P aeas Two sets of criteria are presently used for the diluiton/boration reactivity worth measurements. The first is a review criteria which is violated if the percent difference between measured and predicted reactivity worths for each of the individual control rod banks is not within 215%.

If not met, it requires j

that the Prairie Island Operations Committee be informed.

The decision to L_

continue is made based upon overall plant startup data and the significance L

of the discrepancy.

Second, an acceptance criteria exists which requires that the percent difference between measured and predicted reactivity worths for the total of banks A-D be within 10%.

If this is not met, an N-1 rod worth measurement

(

must be performed.

l Pagie 16 of 23

i For the rod swap test, the reference control rod bank reactivity worth is measured by the dilution /boration technique.

The standard dilution /boration test review criteria of t15% for individual banks will apply to this test.

For the test banks the review criteria of 15% for the individual control rod banks as measured by dilution /boration will be used.

If this rev:ew criteria is not met the required actions shall remain the same as for the dilution /boration method.

If the acceptance criteria is exceeded, the dilution /boration method of control rod bank reactivity worth measurements shall be performed using the same criteria as presently in place. This allows the presently accepted method to be used if any large discrepancies in the rod swap method are present.

The accuracy of the test method will be continually reviewed and the review and acceptance criteria updated as test data is collected.

t i

4 Page 17 of 23

4.0. TEST RESULTS AND COMPARISONS The Prairie Island Unit 2 Cycle 8 and Unit 1 Cycle 9 rod swap analysis was

~

performed using the methodology presented in this report including design predict' ions and test data inferencing. Tables 4.1 and 4.2 present the measured and predicted control rod reactivity worths for both cycles as well as the associated errors and review criteria.

For both cycles control rod-bank A is the reference bank. 'As can be seen from the information presented on these tables, all of the test results met the review criteria and were within acceptable limits.

Comparisons were performed between the rod swap test results and the side-by-side dilution /boration reactivity worth measurements which were performed for these two cycles. As presented in tables 4.1 and 4.2, the basic similarities in the results with respect to the acceptable limits for both tests are demonstrated.

For Prairie Island Unit 2 Cycle 8, presented on table 4.1, the mean of the percent differences was 0.1% for the dilution /boration technique and was 2.6%

1 for the rod swap technique. The standard deviation was 3.5% for the dilution /boration technique and 2.4% for the rod swap technique.

The percent difference associated with the total reactivity worth of the control rod banks was 1.3% for the dilution /boration technique and 1.3% for the rod swap technique.

With the shutdown banks included the value was 2.3% for rod swap.

For Prairie Island Unit 1 Cycle 9, presented on table 4.2, the mean of the percent differences was 6.5% for the dilution /boration technique and was 8.3% for the rod swap technique. The standard deviation was 3.6% for the dilution /boration technique and 4.0% for the rod swap technique. The percent difference associated i

l with'the total reactivity worth of the control rod banks was 6.0% for the dilution /boration technique ano 7.4% for the rod swap technique.

In. summary, the results of all of the tests were within acceptable Ifmits with the rod swap results comparing very well with the side-by-side dilution /boration results.

Both sets of tests adequately demonstrated the validity of the calculational models. Since the same type of infermation about the reactivity worths of the control rod banks is obtained and the trends in the worths between the rod swap technique and the side-by-side dilution /boration technique are very similar, rod swap is a valid method for determining control rod bank reactivity worths.

Page 18 of 23

w; r

c'{fy '

?d c

y TABLE 4.1 PRAIRIE ISLAND 2 CYCLE 8 R00 SWAP vs. DILUTION /B0 RATION l'

Rod $wapTechnique Control Worth (pcm)-

Review Rod Bank-Measured Predicted

'A(pcm).

. A(%)

Criteria (%)

A r-

'1074 1089

-15

-1.4 t15 E'

' ' 707-677 30 4.2 15 1C 1021 1000 21

-2.1 15

'D.:

798 789 9

l'.1 215

' ' SA 760 721 39 5.1 215

-58.

753 721 32-4.2

  • 15 Total (A-0)

--3600 3555 45 1.3 10 Tctal-(A-SB)

- 5113 4997

.116 2.3 10 4

Mean = 2.6%

o = 2.4%

- t 4

e, Dilution /Boration Technique Control..

Worth.(,)cm)

Review

-Rod Bank Measured Predicted A(pcm)

A(%)

Criteria (%)

[-

l'

-A 1074 1089

-15>

-1.4 t15 t.

-D,'A in

. 539 560

-21

-3.9 t15 f

B, A+D in 1221 1200 21 1.7 15 i:

.C,:A+D+B in 1807 1733 74 4.I 15

Total 464d 4582 59 1.3 210 u

Mean = 0.1%

o = 3.5%

L!E Page 19 of 23

..c,-.

. - + - -

_e,---e m-+--y--

~.--,,,.--.--.re.--v.m.-mw_--.-wew

,-,,--,--.-erwrm-.e, 2

.,...-w,mv-,--=ve-- -we v e y - w e -, - -+vwwr

+

TABLE 4.2 PRAIRIE ISLAND 1 CYCLE 9

, R00 SWAP vs.'0ILUTION/BORATION u

.g#

Rod Swap Technique

. Control Worth (pcm).

Review Rod Bank.

Measured Predicted A(pcm) \\

A(%)

Criteria (%)

A 1339 1295 44 3.3 15 E.

645 565 80 12.4 15

~C-997 927 70 7.0 215 D-904 810 94 10.4 15 Total 3885 3597 288 7.4 10 Mean = 8.3%

o = 4.0%

Dilution /Boration Technique Control Worth (pcm)

Review

-Rod Bank Measured Predicted A(pcm)

A(%)

Criteria (%)

JL 1339 1295 44 3.3 215

'B, A in 1011 895-116 11.5 215 0, A+B in.

768 719 49 6.4 15

-C, A+B+0 in 1795 1711 84 4.7 15 Total' 4913 4620 293 6.0 210 Mean = 6.5%

o = 3.6%

4-Page 20 of 23

q.0 CONCLUSIONS 5

Liib

. Based on the results of the side-by-side demonstration programs it has been

.shown that the. rod swap methodology as' outlined in this report is an acceptable

. method to be'used to demonstrate the validity of the results of the calculational models used to predict control rod bank reactivity worths. This method has the potential to'save time and reduce water usage. The conclusion to use the rod swap methodology is applicable to both Prairie Island units since both have been used for_the demonstration purposes.

These conclusions are limited to the two Prairie' Island units. \\

s.

1 i

e Y b

a o

s

,4 Page 21 of 23

.. c 4

T' o

6.0 REFERENCES

1.

" Qualification of Resctor Physics Methods for Application to PI Units",

NSPNAD-8101P Rev.1, December 1982.

I i

l l

I L

l^

I b

l l.

l

[

Pagd 22 of 23 il

=

l DISTRIBUTION

.C. E. Larson, V.P. Nuclear Generation MS3 1

G. H. Neils, Gen Mgr Hdqtrs Nuc Group MS4 L. R. Eliason, Gen Mgr Nuclear Plants MS3 E. L Watzl, PI Plant Manager PI M. A. Klee, Supt Nuclear Engineering (2)

PI D. M. Musolf, Mgr Nuclear Support Services (30)

MS4-C. A. Bonneau, Supt Core Analysis MS4

T. L. Breene, Engineer II

- MS4

-D. W. Dean, Engineer I MS4

-W.~J. Lax, Engineer II MS4 T. J. Tasto, Engineer Associate MS4 J. M. Garrick, Enginecr Associate MS4 D. A. Rautmann, Supt Safety Analysis MS4 Prairie-Island Safety Audit Committee (10)

MS4 R. L. Grow UAI

~ Nuclear Analysis Department file System (10)

MS4 i

i Page 23 of 23 e

.--we,

,m-#,

,,,e.--,,,-,.-.w,w,.+

ween,...

-,r,,,,,-

m,,,.--,

-,--,,--4.,w-,=

yw.-,,--,-.

m